| Plan Review Stops For Permit 07070599 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-09-08 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-09-08 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2008-09-08 13:59:16 | REVISED SHEETS 1 AND 2 OK FOR BUILDING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-09-03 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-09-03 |
Time |
09:56 |
Sent To |
P |
|
| Notes |
| 2008-09-03 09:58:05 | REVISED SHEETS 1 AND 2 OK FOR BUILDING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-08-04 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-08-04 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-07-10 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-07-10 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2008-07-10 14:30:11 | 2004 FBC W/2007 REVISIONS | | | CONVERT GARAGE TO LIVING SPACE | | | | | | DENIED BY BUILDING | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | THE PRODUCT APPROVALS THAT WERE SUBMITTED HAVE NOT BEEN | | | APPROVED IN WRITING BY THE ENGINEER. | | | | | | 3) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | STORM PANELS ARE EXPIRED. SUBMIT CURRENT PRODUCT | | | APPROVALS. DCA RULE 9B-72. IN ORDER TO DETERMINE CODE | | | COMPLIANCE WITH FBC R301.2.1.2, SPECIFY THE MOUNT TYPE, | | | ANCHOR TYPE AND ANCHOR SPACING FOR THE STORM PANELS. | | | SEE ATTACHED STORM PANEL INSTALLATION SCHEDULE. | | | | | | 4)THE PRODUCT APPROVALS SUBMITTED FOR THE WINDOWS ARE | | | NOT ACCEPTABLE. INSTALLATION DRAWINGS AND DESIGN | | | PRESSURES FOR THE WINDOWS ARE REQUIRED. DCA RULE 9B-72 | | | AND FBC R613. ALSO THE PLAN SPECIFIES A SINGLE HUNG | | | WINDOW AND A PRODUCT APPROVAL FOR DOUBLE HUNG WINDOWS | | | WAS SUBMITTED. | | | | | | 5) SPECIFY THE CONNECTORS THAT WILL BE USED TO ATTACH | | | THE 2 X 6 WOOD STUDS TO THE TOP AND BOTTOM PLATES AT | | | THE GARAGE DOOR OPENING INFILL. FBC R 301.1 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-01-29 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-01-28 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2008-01-29 07:16:26 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT ENERGY CALCULATIONS FOR THE ENCLOSED GARAGE | | | AS REQUIRED BY FBC CHAPTER 13. TWO COPIES ARE REQUIRED. | | | THE WRONG FORMS WERE SUBMITTED. THE FORM FOR SOUTH | | | CLIMATE ZONES 7,8 AND 9 IS REQUIRED. THE CITY OF WEST | | | PALM BEACH IS LOCATED IN CLIMATE ZONE 8. THE | | | OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE ENERGY | | | CALCULATION FORMS. SEE FBC SECTION 13-6. | | | | | | 4) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED | | | GRADE. | | | CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND | | | ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT | | | ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY | | | VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM) | | | ELSEWHERE. ALSO SEE SECTION 704 INSPECTION FOR | | | TERMITES. | | | IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE | | | INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS | | | AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING | | | SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS: | | | 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS | | | THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE | | | MASONRY FOUNDATION SIDEWALL. | | | 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE | | | INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH | | | RAMPS ONLY. | | | 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO | | | AND GARAGE SLABS AND ENTRY AREAS. | | | 4.IF THE PATIO HAS BEEN SOIL TREATED FOR TERMITES, | | | THE FINISH ELEVATION MAY MATCH THE BUILDING INTERIOR | | | FINISH FLOOR ELEVATIONS ON MASONRY CONSTRUCTION ONLY. | | | 5.MASONRY VENEERS. | | | A CONCRETE CURB UNDER THE FRAME WALL OR OTHER | | | ACCEPTABLE METHOD COULD BE USED AT THE GARAGE DOOR | | | OPENING OR IT COULD BE ENCLOSED WITH MASONRY. | | | | | | 5) SHOW COMPLIANCE WITH R506.2.3 VAPOR RETARDER. A 6 | | | MIL (0.006 INCH; 152 UM) POLYETHYLENE OR APPROVED VAPOR | | | RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 INCHES (152 | | | MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND | | | THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE | | | COURSE EXISTS. THE CODE DOES NOT REQUIRE THIS IN | | | GARAGES OR UNHEATED ACCESSORY STRUCTURES. HOWEVER, THIS | | | AREA IS BEING CONVERTED TO LIVING SPACE WHICH DOES | | | REQUIRE A VAPOR RETARDER. NOTE: THE EXISTING CONCRETE | | | CAN SEALED WITH AN APPROVED WATER PROOFING. SPECIFY ON | | | THE PLANS. | | | | | | 6) PROVIDE A SECTION OF THE EXTERIOR WALL AT THE | | | IN-FILL FRAMING AT THE GARAGE DOOR OPENING. SHOW THE | | | HEIGHT OF THE FINISH FLOOR ABOVE GRADE, THE CEILING | | | HEIGHT AND FINISH, SPECIFY THE INTERIOR AND EXTERIOR | | | WALL COVERINGS, VAPOR BARRIERS, INSULATION,FRAMING | | | CONNECTORS, FASTENERS, ANCHORS ETC.FBC 106.1.2 | | | | | | 7)SHOW COMPLIANCE WITH R310 FOR EMERGENCY ESCAPE AND | | | RESCUE OPENINGS REQUIRED FOR SLEEPING ROOMS. WINDOWS | | | SPECIFIED ON THE PLAN DO NOT COMPLY WITH THE REQUIRED | | | CLEAR OPENING. R310.1 EMERGENCY ESCAPE AND RESCUE | | | REQUIRED. | | | BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM | | | SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND | | | RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE | | | SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS | | | SHALL BE REQUIRED IN EACH SLEEPING ROOM, BUT SHALL NOT | | | BE REQUIRED IN ADJOINING AREAS OF THE BASEMENT. WHERE | | | EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY | | | SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES | | | (1118 MM) ABOVE THE FLOOR. WHERE A DOOR OPENING HAVING | | | A THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES | | | AS AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS | | | PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEAD | | | ENCLOSURE SHALL COMPLY WITH SECTION 310.3 . THE NET | | | CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL | | | BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY | | | ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY | | | ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT | | | BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED | | | WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2 . | | | THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE | | | PERMITTED TO OPEN INTO A SCREEN ENCLOSURE, OPEN TO THE | | | ATMOSPHERE, WHERE A SCREEN DOOR IS PROVIDED LEADING | | | AWAY FROM THE RESIDENCE. | | | R310.1.1 MINIMUM OPENING AREA. | | | ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A | | | MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET (0.530 M 2 | | | ). | | | EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM | | | NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M 2 ). | | | R310.1.2 MINIMUM OPENING HEIGHT. | | | THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES | | | (610 MM). | | | R310.1.3 MINIMUM OPENING WIDTH. | | | THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES | | | (508 MM). | | | | | | 8) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE | | | EXTERIOR WINDOWS AND STORM PANELS (IF WINDOWS ARE NOT | | | IMPACT RATED). SPECIFYTHE MOUNT TYPE, ANCHOR TYPE AND | | | ANCHOR SPACING FOR THE STORM PANELS. CIRCLE THE | | | APPROPRIATE INFORMATION ON THE PRODUCT APPROVAL | | | DRAWINGS AND TABLES. | | | | | | 9)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. | | | | | | 10)FBC 106.3* CITY AMENDMENTS PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. THIS APPLIES TO THE WINDOW | | | AND STORM PANEL PRODUCT APPROVALS. | | | | | | 11) ON SHEET 1 THERE IS A NOTE BELOW THE FLOOR PLAN | | | THAT STATES ADD 6" BATT INSULATION IN THE CEILING. ALSO | | | ON SHEET 1, THE INTERIOR WALL SECTION SPECIFIES 9" | | | (R30) BATT INSULATION. PLEASE CORRECT. | | | | | | 12) ADDRESS COMMENTS OF OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-08-01 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-08-01 |
Time |
16:57 |
Sent To |
P |
|
| Notes |
| 2007-08-01 18:26:28 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) SUBMIT ENERGY CALCULATIONS FOR THE ENCLOSED GARAGE | | | AS REQUIRED BY FBC CHAPTER 13. | | | | | | 4) PROVIDE EXTERIOR ELEVATIONS OF THE ENCLOSED GARAGE. | | | | | | | | | 5) SPECIFY THE WIND DESIGN DATA ON THE PLANS AS | | | REQUIRED BY FBC 1603.1.4. THE BASIC WINDSPEED, THE | | | IMPORTANCE FACTOR,COMPONENT AND CLADDING PRESSURES, | | | ETC. | | | | | | 6) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE | | | FBC EXISTING BUILDING CODE CHAPTER 3. | | | | | | 7) SPECIFY THE CURRENT CODE EDITION ON THE PLANS. | | | | | | 8) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED | | | GRADE. | | | CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND | | | ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT | | | ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY | | | VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM) | | | ELSEWHERE. | | | | | | 9) SHOW COMPLIANCE WITH R320.1TERMITE PROTECTION SHALL | | | BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL | | | APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES | | | APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE | | | PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT | | | TO NEW CONSTRUCTION (SEE SECTION 202 , REGISTERED | | | TERMITICIDE). UPON COMPLETION OF THE APPLICATION OF THE | | | TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF | | | COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT | | | BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE | | | FOLLOWING STATEMENT: ?THE BUILDING HAS RECEIVED A | | | COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN | | | TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND | | | LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF | | | AGRICULTURE AND CONSUMER SERVICES.? | | | | | | 10) SHOW COMPLIANCE WITH R506.2.3 VAPOR RETARDER. A 6 | | | MIL (0.006 INCH; 152 ?M) POLYETHYLENE OR APPROVED VAPOR | | | RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 INCHES (152 | | | MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND | | | THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE | | | COURSE EXISTS. | | | | | | 11) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED. | | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | | RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE | | | SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE | | | ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE | | | PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 / | | | 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM | | | OPENINGS. | | | | | | 12) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS.THE | | | ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 INCHES | | | BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE LOCATED IN | | | A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. A | | | 30-INCH (762 MM) MINIMUM UNOBSTRUCTED HEADROOM IN THE | | | ATTIC SPACE SHALL BE PROVIDED AT SOME POINT ABOVE THE | | | ACCESS OPENING. SEE SECTION M1305.1.3 FOR ACCESS | | | REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN | | | ATTICS. | | | | | | 13) PROVIDE A SECTION OF THE EXTERIOR WALL AT THE | | | IN-FILL FRAMING AT THE GARAGE DOOR OPENING. SHOW THE | | | HEIGHT OF THE FINISH FLOOR ABOVE GRADE, THE CEILING | | | HEIGHT AND FINISH, SPECIFY THE INTERIOR AND EXTERIOR | | | WALL COVERINGS, VAPOR BARRIERS, INSULATION,FRAMING | | | CONNECTORS, FASTENERS, ANCHORS ETC.FBC 106.1.2 | | | | | | 14)THERE IS A TYPICAL WALL SECTION ON THE PLANS. | | | PLEASE INDICATE IF THIS IS AN INTERIOR LOAD BEARING OR | | | NON LOAD BEARING WALL. SPECIFY THE LENGTH/EMBED DEPTH | | | OF THE RED HEAD ANCHORS. | | | | | | 15) SPECIFY THE WINDOW TYPES (IE SINGLE HUNG, CASEMENT, | | | ETC.) AND SPECIFY THE REQUIRED OPENING PRESSURES. | | | | | | 16)SHOW COMPLIANCE WITH R310 FOR EMERGENCY ESCAPE AND | | | RESCUE OPENINGS REQUIRED FOR SLEEPING ROOMS. | | | | | | 17) SUBMIT PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS | | | AND STORM PANELS (IF WINDOWS ARE NOT IMPACT RATED). | | | SPECIFYTHE MOUNT TYPE, ANCHOR TYPE AND ANCHOR SPACING | | | FOR THE STORM PANELS. | | | | | | 18)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. | | | | | | 19)WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 20) ADDRESS COMMENTS OF OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2008-09-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-05 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-09-05 |
Time |
15:43 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-09-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-09-02 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-09-02 |
Time |
09:14 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-31 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-31 |
Time |
16:22 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-07-08 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-07-08 |
Time |
06:57 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-01-17 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-01-17 |
Time |
08:18 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-07-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-27 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-26 |
Time |
06:52 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-05 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-05 |
Time |
10:59 |
Sent To |
E |
|
| Notes |
| 2008-09-05 10:59:46 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-28 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-28 |
Time |
16:20 |
Sent To |
E |
|
| Notes |
| 2008-08-28 16:21:07 | TO "ELECT" BILL T. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-31 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-31 |
Time |
12:20 |
Sent To |
E |
|
| Notes |
| 2008-07-31 12:21:13 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-01 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-01 |
Time |
12:22 |
Sent To |
Z |
|
| Notes |
| 2008-07-01 12:22:57 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-01-10 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2008-01-10 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2008-01-10 |
Time |
08:29 |
Sent To |
Z |
|
| Notes |
| 2008-01-10 08:29:54 | TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-02 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-20 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2007-07-20 10:33:39 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-08 |
Time |
08:49 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-09-08 |
Time |
08:49 |
Sent To |
P |
|
| Notes |
| 2008-09-08 08:49:55 | REVISION TO MECH. PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2008-09-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-09-04 |
Time |
09:32 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-09-04 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2008-09-04 09:54:23 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO PLANS | | | *** DENIED *** | | | | | | 1) PAGE 1 OF 2 FLOOR PLAN SHOWS AN A/C GRILL IN THE | | | STUDY (SEE YELLOW HIGH LIGHT ON PLAN) PLEASE STATE IF | | | GRILL IS SUPPLY, RETURN, SHOW SIZE. CFM'S. AND PROVIDE | | | THE DUCT (FLEX) INFORMATION, PER 2004 WPB | | | AMEND.106.3.5.4 (10). | | | | | | 2) PLAN SHOWS AN A/C GRILL IN THE BATHROOM, PLEASE SEE | | | NOTE ABOVE. | | | | | | 3) SHOW THE CFM'S AT THE BATHROOM EXHAUST FAN, PER 2004 | | | FBC/R M1506.3. | | | | | | 4) STATE ON PLAN WHERE THE BATHROOM EXHAUST FAN WILL | | | TERMINATE, PER 2004 FBC/R M1506.2. | | | | | | 5) PLAN STATES "EXISTING DOOR TO STUDY A/C RETURN" IF | | | THE DOOR IS TO BE USED AS A RETURN IT MUST BE LOUVERED | | | OR HAVE A TRANSFER GRILL INSTALLED (IF GRILL SHOW SIZE) | | | STATE ON PLAN WHICH IS BEING USED, PER 2004 FBC/R | | | M1602.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-01 |
Time |
08:29 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-08-01 |
Time |
08:29 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-07-08 |
Time |
08:35 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-07-08 |
Time |
08:35 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-01-17 |
Time |
14:44 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-01-17 |
Time |
14:44 |
Sent To |
P |
|
| Notes |
| 2008-01-17 15:00:38 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-600.3.ABC.2. (PLEASE SUBMIT 2 | | | COPY'S). | | | | | | 2) WAS UNABLE TO FIND THE ALEN AMS09 DUCTLESS | | | MINI-SPLIT A/C SYSTEM ON THE ARI DIRECTORY WEB-SITE. | | | PLEASE SUBMIT THE ARI CERTIFICATE, SEE 2004 FBC | | | 13-607.1.ABC.3.1.1. | | | | | | 3) PLEASE ADD AN A/C SCHEDULE WITH THE PERTINENT | | | INFORMATION TO THE MECHANICAL PLAN, SEE 2004 WPB AMEND. | | | 106.3.5.4 (10). | | | | | | 4) PLEASE SUBMIT DETAILED MANUFACTURER'S | | | SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR THE | | | A/C SYSTEM. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-27 |
Time |
09:54 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-27 |
Time |
09:54 |
Sent To |
P |
|
| Notes |
| 2007-07-27 10:00:02 | *** DENIED *** | | | 1) THE ENGINEER WHO SEALED THE PLANS MUST ALSO HAVE | | | THEIR PRINTED NAME AND LICENSE NUMBER IN THE TITLE | | | BLOCK, SEE FAC 61G-15-23.002, PLEASE CORRECT. | | | | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC | | | 13-101.2.2. | | | | | | 3) PLANS NOTE ADD 6" BATT INSULATION IN CEILING, PLEASE | | | ADD WHAT THE R-VALUE WILL BE. | | | | | | 4) PLEASE STATE ON PLANSIF THE EXISTING WATER HEATER | | | IS GAS OR ELECTRIC, AND SHOW HOW IT WILL BE ACCESSED. | | | | | | 5) MECHANICAL PERMIT #07070601 HAS BEEN APPLIED FOR AND | | | APPLICATION STATES EXTEND A/C, PLEASE SUBMIT MECHANICAL | | | PLAN FOR REVIEW, SEE 2004 FBC CITY OF WPB AMEND. | | | 106.3.5.4 #10. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-09-08 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-09-08 |
Time |
09:37 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-09-03 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-09-03 |
Time |
16:17 |
Sent To |
M |
|
| Notes |
| 2008-09-03 16:40:34 | PLUMBING PLAN REVIEW: | | | REVISION DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET 1 SANITARY RISER: PLEASE CORRECT THE FOLLOWING | | | PER THE FBC-2004 PLUMBING CODE SECTIONS. | | | | | | A} THERE IS A 3 INCH HORIZONTAL DRY VENT BEING | | | INDICATED UPSTREAM OF THE WATER CLOSET. HORIZONTAL DRY | | | VENTS ARE NOT ALLOWED. PER SECTION 905.3 VENT | | | CONNECTION TO DRAINAGE SYSTEM. | | | | | | B} LAVATORY NEEDS A VENT AND A WATER-SEAL TRAP. PER | | | SECTION 901.2.1 VENTING REQUIRED AND SECTION 1002.1 | | | FIXTURE TRAP. | | | NOTE: IF A 1-1/4" TRAP IS USED ON THE LAVATORY A | | | CLEANOUT IS REQUIRED AT THE BASE OF ITS STACK (SECTION | | | 708.3.4 BASE OF STACK), HOWEVER IF A 1-1/2" TRAP IS | | | USED PER 708.7 MINIMUM SIZE EXCEPTION (1) A CLEANOUT IS | | | NOT REQUIRED. | | | | | | C} THE 3 INCH HORIZONTAL BRANCH AND STACK IS NOT | | | CLEARLY IDENTIFIED. IS THIS FOR THE WASHING MACHINE? | | | PLEASE CLARIFY THIS AND PROVIDE THE FOLLOWING FOR THE | | | WASHING MACHINE. | | | *SECTION 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. | | | | | | *SECTION 802.4 STANDPIPES.STANDPIPES SHALL BE | | | INDIVIDUALLY TRAPPED. STANDPIPES SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS | | | FOR RODDING. | | | | | | *SECTION 708.7 MINIMUM SIZE. CLEANOUTS SHALL | | | BE THE SAME NOMINAL SIZE AS THE PIPE | | | THEY SERVE UP TO 4 INCHES (102MM). | | | CLEANOUT FOR THE WASHING MACHINE SHALL BE 3 INCH. | | | | | | *SECTION 708.9 ACCESS. ACCESS SHALL BE PROVIDED TO ALL | | | CLEANOUTS. CLEANOUT FOR THE WASHING MACHINE SHALL BE | | | LOCATED AT FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.). | | | | | | D} CLEARLY INDICATE A TWO-WAY CLEANOUT AT THE JUNCTION | | | OF THE BUILDING DRAIN AND BUILDING SEWER. PER SECTION | | | 708.3.5 BUILDING DRAIN AND BUILDING SEWER JUNCTION. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | NOTE: PLEASE REFERENCE THE EXAMPLE SANITARY ISOMETRIC | | | RISER DIAGRAM THAT REFLECTS THE FLOOR PLAN AND IS CODE | | | COMPLIANT TO HELP IN THE REVISON ATTACHED TO THESE | | | PLUMBING COMMENTS. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-08-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-08-01 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-08-01 |
Time |
13:49 |
Sent To |
B |
|
| Notes |
| 2008-08-01 14:25:18 | ****************PROVISO**************** | | | NOTE: A REVISION SHALL BE REQUIRED OF THE SANITARY | | | ISOMETRIC RISER DIAGRAM THAT REFLECTS THE PROPOSED | | | FLOOR PLAN BEFORE FINAL INSPECTION. THE WASHING MACHINE | | | BRANCH DRAIN AND STACK SHALL BE 3 INCH AND THE CLEANOUT | | | FOR THE WASHING MACHINE STACK SHALL BE LOCATED @ 4' | | | A.F.F. FOR ACCESS. PER FBC-2004 PLUMBING SECTIONS 406.3 | | | WASTE CONNECTIONS, SECTION 701.1 SCOPE, AND SECTION | | | 708.9 ACCESS. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-08 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-08 |
Time |
13:09 |
Sent To |
B |
|
| Notes |
| 2008-07-08 13:20:59 | PLUMBING PLAN REVIEW: | | | DENIED 3RD TIME: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | 1. SHEET 1, SANITARY ISOMETRIC RISER DIAGRAM: PLEASE | | | CORRECT THE FOLLOWING PER FBC-2004 PLUMBING SECTIONS. | | | | | | | | | A} SECTION 701.1 SCOPE, 901.1 SCOPE, AND (W.P.B. AS | | | AMENDED) 106.3.5.4 (9) PLUMBING: CLEARLY INDICATE THE | | | SIZES TO ALL WASTE, VENTS AND WATER-SEAL TRAPS. THE | | | ONLY SIZE PIPING BEING INDICATED ON THE PLANS IS 3 INCH | | | BY THE CLEANOUT AND 3" VTR. IS IT THE INTENT TO HAVE | | | ALL WASTE PIPING 3 INCH? | | | | | | B} SECTION 905.3 VENT CONNECTION TO DRAINAGE SYSTEM, | | | NO HORIZONTAL DRY VENTS ARE ALLOWED (DRY VENT BETWEEN | | | SHOWER AND VENT THRU ROOF NOT ALLOWED). | | | | | | C} SECTION 901.2.1 VENTING REQUIRED, THE WASHING | | | MACHINE AND LAVATORY REQUIRE A VENT. | | | | | | D} SECTION 1002.3 PROHIBITED TRAPS, THE LAVATORY IS | | | INDICATING A "S" TRAP WHICH IS PROHIBITED. | | | | | | E} SECTION 701.1 SCOPE, PLANS DO NOT CLEARLY INDICATE | | | THAT THE PROPOSED BATHROOM SANITARY SYSTEM WILL TIE | | | INTO THE EXISTING. | | | | | | F} SECTION 708.3.5 BUILDING DRAIN AND BUILDING SEWER | | | JUNCTION, CLEARLY INDICATE THE CLEANOUT AT THE JUNCTION | | | OF THE BUILDING DRAIN AND BUILDING SEWER AS BEING A | | | TWO-WAY CLEANOUT. | | | | | | G} SECTION 405.3.1 WATER CLOSETS, URINALS, LAVATORIES, | | | AND BIDETS. A WATER CLOSET, URINAL, LAVATORY OR BIDET | | | SHALL NOT BE SET CLOSER THAN 15 INCHES (381 MM) FROM | | | ITS CENTER TO ANY SIDE WALL, PARTITION, VANITY OR OTHER | | | OBSTRUCTION, OR CLOSER THAN 30 INCHES (762 MM) | | | CENTER-TO-CENTER BETWEEN WATER CLOSETS, URINALS OR | | | ADJACENT FIXTURES. THERE SHALL BE AT LEAST A 21-INCH | | | (533 MM) CLEARANCE IN FRONT OF THE WATER CLOSET, URINAL | | | OR BIDET TO ANY WALL, FIXTURE OR DOOR. WATER CLOSET | | | COMPARTMENTS SHALL NOT BE LESS THAN 30 INCHES (762 MM) | | | WIDE OR 60 INCHES (1524 MM) DEEP. THERE SHALL BE AT | | | LEAST A 21-INCH (533 MM) CLEARANCE IN FRONT OF A | | | LAVATORY TO ANY WALL, FIXTURE OR DOOR (SEE FIGURE | | | 405.3.1 ). | | | NOTE: THE LAVATORY IS NOT COMPLIANT. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-01-25 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-01-25 |
Time |
09:04 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-02 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-02 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2007-08-02 11:14:37 | DENIED; | | | 1. SANITARY RISER DIAGRAM; | | | A) AUTOMATIC CLOTHES WASHER SHALL DISCHARGE | | | DOWN STREAM OF THE BATHROOM GROUP. SEE FBC-2004 | | | PLUMBING SECTION 909.1. | | | B) SHOW TRAPS ON LAVATORY AND SHOWER. | | | C) HORIZONTAL DRY VENTS ARE NOT PERMITTED. | | | SEC905.3 | | | 2. THERE MUST BE 21" IN FRONT OF THE LAVATORY. SEE | | | SECTION 405.3.1. | | | 3. THE LINE BETWEEN THE TOILET AND THE WATER HEATER, IS | | | THAT A WALL? IF SO ACCESS IS REQUIRED TO HEATER IF NOT | | | IF ELECTRICMUST BE A GFI , IF GAS IT IS NOT PERMITED | | | IN BATHROOM. PLEASE CLARIFY. | | | 4. SHOWER REQUIRES A CURB ON OPEN SIDES, NOT SHOWN. IF | | | INCLOSED SHOW DOOR. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-07-07 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-07-07 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-07-07 |
Time |
09:51 |
Sent To |
E |
|
| Notes |
| 2008-07-07 09:51:55 | ***APPROVED - RESUB #2 - RESTAMPED PLANS*** | | | | | | PROVISOS: | | | 1)STRUCTURE MUST MAINTAIN INTERIOR ACCESS. | | | 2)NO SEPARATE DWELLING UNIT PERMITTED. | | | | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2008-01-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-14 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-14 |
Time |
11:27 |
Sent To |
E |
|
| Notes |
| 2008-01-14 11:28:27 | ***APPROVED - RESUB #1*** | | | | | | | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-20 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-20 |
Time |
17:52 |
Sent To |
E |
|
| Notes |
| 2007-07-20 17:55:48 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE A SITE PLAN SHOWING REMAINDER OF | | | RESIDENCE. | | | | | | 2)INTERIOR ACCESS MUST BE PROVIDED TO ALL AREAS | | | WITHIN A DWELLING UNIT. | | | | | | 3)NO SEPARATE DWELLING UNIT PERMITTED IN SF7 ZONING | | | DISTRICT. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|