Plan Review Details - Permit 07070599
Plan Review Stops For Permit 07070599
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-09-08 Cont ID  
Sent By rmcdouga Date 2008-09-08 Time 13:59 Rev Time 0.00
Received By rmcdouga Date 2008-09-08 Time 13:59 Sent To  
Notes
2008-09-08 13:59:16REVISED SHEETS 1 AND 2 OK FOR BUILDING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-09-03 Cont ID  
Sent By rmcdouga Date 2008-09-03 Time 09:56 Rev Time 0.00
Received By rmcdouga Date 2008-09-03 Time 09:56 Sent To P
Notes
2008-09-03 09:58:05REVISED SHEETS 1 AND 2 OK FOR BUILDING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-08-04 Cont ID  
Sent By rmcdouga Date 2008-08-04 Time 08:22 Rev Time 0.00
Received By rmcdouga Date 2008-08-04 Time 08:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2008-07-10 Cont ID  
Sent By rmcdouga Date 2008-07-10 Time 14:30 Rev Time 0.00
Received By rmcdouga Date 2008-07-10 Time 14:30 Sent To  
Notes
2008-07-10 14:30:112004 FBC W/2007 REVISIONS
 CONVERT GARAGE TO LIVING SPACE
  
 DENIED BY BUILDING
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2)FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 THE PRODUCT APPROVALS THAT WERE SUBMITTED HAVE NOT BEEN
 APPROVED IN WRITING BY THE ENGINEER.
  
 3) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 STORM PANELS ARE EXPIRED. SUBMIT CURRENT PRODUCT
 APPROVALS. DCA RULE 9B-72. IN ORDER TO DETERMINE CODE
 COMPLIANCE WITH FBC R301.2.1.2, SPECIFY THE MOUNT TYPE,
 ANCHOR TYPE AND ANCHOR SPACING FOR THE STORM PANELS.
 SEE ATTACHED STORM PANEL INSTALLATION SCHEDULE.
  
 4)THE PRODUCT APPROVALS SUBMITTED FOR THE WINDOWS ARE
 NOT ACCEPTABLE. INSTALLATION DRAWINGS AND DESIGN
 PRESSURES FOR THE WINDOWS ARE REQUIRED. DCA RULE 9B-72
 AND FBC R613. ALSO THE PLAN SPECIFIES A SINGLE HUNG
 WINDOW AND A PRODUCT APPROVAL FOR DOUBLE HUNG WINDOWS
 WAS SUBMITTED.
  
 5) SPECIFY THE CONNECTORS THAT WILL BE USED TO ATTACH
 THE 2 X 6 WOOD STUDS TO THE TOP AND BOTTOM PLATES AT
 THE GARAGE DOOR OPENING INFILL. FBC R 301.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-01-29 Cont ID  
Sent By rmcdouga Date 2008-01-29 Time 07:16 Rev Time 0.00
Received By rmcdouga Date 2008-01-28 Time 16:11 Sent To  
Notes
2008-01-29 07:16:26DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SUBMIT ENERGY CALCULATIONS FOR THE ENCLOSED GARAGE
 AS REQUIRED BY FBC CHAPTER 13. TWO COPIES ARE REQUIRED.
 THE WRONG FORMS WERE SUBMITTED. THE FORM FOR SOUTH
 CLIMATE ZONES 7,8 AND 9 IS REQUIRED. THE CITY OF WEST
 PALM BEACH IS LOCATED IN CLIMATE ZONE 8. THE
 OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE ENERGY
 CALCULATION FORMS. SEE FBC SECTION 13-6.
  
 4) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED
 GRADE.
 CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND
 ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT
 ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY
 VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM)
 ELSEWHERE. ALSO SEE SECTION 704 INSPECTION FOR
 TERMITES.
 IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE
 INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS
 AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING
 SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS:
 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS
 THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE
 MASONRY FOUNDATION SIDEWALL.
 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE
 INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH
 RAMPS ONLY.
 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO
 AND GARAGE SLABS AND ENTRY AREAS.
 4.IF THE PATIO HAS BEEN SOIL TREATED FOR TERMITES,
 THE FINISH ELEVATION MAY MATCH THE BUILDING INTERIOR
 FINISH FLOOR ELEVATIONS ON MASONRY CONSTRUCTION ONLY.
 5.MASONRY VENEERS.
 A CONCRETE CURB UNDER THE FRAME WALL OR OTHER
 ACCEPTABLE METHOD COULD BE USED AT THE GARAGE DOOR
 OPENING OR IT COULD BE ENCLOSED WITH MASONRY.
  
 5) SHOW COMPLIANCE WITH R506.2.3 VAPOR RETARDER. A 6
 MIL (0.006 INCH; 152 UM) POLYETHYLENE OR APPROVED VAPOR
 RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 INCHES (152
 MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND
 THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE
 COURSE EXISTS. THE CODE DOES NOT REQUIRE THIS IN
 GARAGES OR UNHEATED ACCESSORY STRUCTURES. HOWEVER, THIS
 AREA IS BEING CONVERTED TO LIVING SPACE WHICH DOES
 REQUIRE A VAPOR RETARDER. NOTE: THE EXISTING CONCRETE
 CAN SEALED WITH AN APPROVED WATER PROOFING. SPECIFY ON
 THE PLANS.
  
 6) PROVIDE A SECTION OF THE EXTERIOR WALL AT THE
 IN-FILL FRAMING AT THE GARAGE DOOR OPENING. SHOW THE
 HEIGHT OF THE FINISH FLOOR ABOVE GRADE, THE CEILING
 HEIGHT AND FINISH, SPECIFY THE INTERIOR AND EXTERIOR
 WALL COVERINGS, VAPOR BARRIERS, INSULATION,FRAMING
 CONNECTORS, FASTENERS, ANCHORS ETC.FBC 106.1.2
  
 7)SHOW COMPLIANCE WITH R310 FOR EMERGENCY ESCAPE AND
 RESCUE OPENINGS REQUIRED FOR SLEEPING ROOMS. WINDOWS
 SPECIFIED ON THE PLAN DO NOT COMPLY WITH THE REQUIRED
 CLEAR OPENING. R310.1 EMERGENCY ESCAPE AND RESCUE
 REQUIRED.
 BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM
 SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND
 RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE
 SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS
 SHALL BE REQUIRED IN EACH SLEEPING ROOM, BUT SHALL NOT
 BE REQUIRED IN ADJOINING AREAS OF THE BASEMENT. WHERE
 EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY
 SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES
 (1118 MM) ABOVE THE FLOOR. WHERE A DOOR OPENING HAVING
 A THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES
 AS AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS
 PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEAD
 ENCLOSURE SHALL COMPLY WITH SECTION 310.3 . THE NET
 CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL
 BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY
 ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY
 ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT
 BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED
 WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2 .
 THE EMERGENCY ESCAPE AND RESCUE OPENING SHALL BE
 PERMITTED TO OPEN INTO A SCREEN ENCLOSURE, OPEN TO THE
 ATMOSPHERE, WHERE A SCREEN DOOR IS PROVIDED LEADING
 AWAY FROM THE RESIDENCE.
 R310.1.1 MINIMUM OPENING AREA.
 ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A
 MINIMUM NET CLEAR OPENING OF 5.7 SQUARE FEET (0.530 M 2
 ).
 EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM
 NET CLEAR OPENING OF 5 SQUARE FEET (0.465 M 2 ).
 R310.1.2 MINIMUM OPENING HEIGHT.
 THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES
 (610 MM).
 R310.1.3 MINIMUM OPENING WIDTH.
 THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES
 (508 MM).
  
 8) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE
 EXTERIOR WINDOWS AND STORM PANELS (IF WINDOWS ARE NOT
 IMPACT RATED). SPECIFYTHE MOUNT TYPE, ANCHOR TYPE AND
 ANCHOR SPACING FOR THE STORM PANELS. CIRCLE THE
 APPROPRIATE INFORMATION ON THE PRODUCT APPROVAL
 DRAWINGS AND TABLES.
  
 9)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE.
  
 10)FBC 106.3* CITY AMENDMENTS PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. THIS APPLIES TO THE WINDOW
 AND STORM PANEL PRODUCT APPROVALS.
  
 11) ON SHEET 1 THERE IS A NOTE BELOW THE FLOOR PLAN
 THAT STATES ADD 6" BATT INSULATION IN THE CEILING. ALSO
 ON SHEET 1, THE INTERIOR WALL SECTION SPECIFIES 9"
 (R30) BATT INSULATION. PLEASE CORRECT.
  
 12) ADDRESS COMMENTS OF OTHER TRADES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-01 Cont ID  
Sent By rmcdouga Date 2007-08-01 Time 18:26 Rev Time 0.00
Received By rmcdouga Date 2007-08-01 Time 16:57 Sent To P
Notes
2007-08-01 18:26:28DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SUBMIT ENERGY CALCULATIONS FOR THE ENCLOSED GARAGE
 AS REQUIRED BY FBC CHAPTER 13.
  
 4) PROVIDE EXTERIOR ELEVATIONS OF THE ENCLOSED GARAGE.
  
  
 5) SPECIFY THE WIND DESIGN DATA ON THE PLANS AS
 REQUIRED BY FBC 1603.1.4. THE BASIC WINDSPEED, THE
 IMPORTANCE FACTOR,COMPONENT AND CLADDING PRESSURES,
 ETC.
  
 6) SPECIFY THE LEVEL OF ALTERATION ON THE PLANS. SEE
 FBC EXISTING BUILDING CODE CHAPTER 3.
  
 7) SPECIFY THE CURRENT CODE EDITION ON THE PLANS.
  
 8) SHOW COMPLIANCE WITH R404.1.6 HEIGHT ABOVE FINISHED
 GRADE.
 CONCRETE AND MASONRY FOUNDATION WALLS SHALL EXTEND
 ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION AT
 ALL POINTS A MINIMUM OF 4 INCHES (102 MM) WHERE MASONRY
 VENEER IS USED AND A MINIMUM OF 6 INCHES (152 MM)
 ELSEWHERE.
  
 9) SHOW COMPLIANCE WITH R320.1TERMITE PROTECTION SHALL
 BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL
 APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES
 APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE
 PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT
 TO NEW CONSTRUCTION (SEE SECTION 202 , REGISTERED
 TERMITICIDE). UPON COMPLETION OF THE APPLICATION OF THE
 TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF
 COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT
 BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE
 FOLLOWING STATEMENT: ?THE BUILDING HAS RECEIVED A
 COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
 TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND
 LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF
 AGRICULTURE AND CONSUMER SERVICES.?
  
 10) SHOW COMPLIANCE WITH R506.2.3 VAPOR RETARDER. A 6
 MIL (0.006 INCH; 152 ?M) POLYETHYLENE OR APPROVED VAPOR
 RETARDER WITH JOINTS LAPPED NOT LESS THAN 6 INCHES (152
 MM) SHALL BE PLACED BETWEEN THE CONCRETE FLOOR SLAB AND
 THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE
 COURSE EXISTS.
  
 11) SHOW COMPLIANCE WITH R806.1 VENTILATION REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE
 SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE
 ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE
 PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 /
 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM
 OPENINGS.
  
 12) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS.THE
 ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 INCHES
 BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE LOCATED IN
 A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. A
 30-INCH (762 MM) MINIMUM UNOBSTRUCTED HEADROOM IN THE
 ATTIC SPACE SHALL BE PROVIDED AT SOME POINT ABOVE THE
 ACCESS OPENING. SEE SECTION M1305.1.3 FOR ACCESS
 REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN
 ATTICS.
  
 13) PROVIDE A SECTION OF THE EXTERIOR WALL AT THE
 IN-FILL FRAMING AT THE GARAGE DOOR OPENING. SHOW THE
 HEIGHT OF THE FINISH FLOOR ABOVE GRADE, THE CEILING
 HEIGHT AND FINISH, SPECIFY THE INTERIOR AND EXTERIOR
 WALL COVERINGS, VAPOR BARRIERS, INSULATION,FRAMING
 CONNECTORS, FASTENERS, ANCHORS ETC.FBC 106.1.2
  
 14)THERE IS A TYPICAL WALL SECTION ON THE PLANS.
 PLEASE INDICATE IF THIS IS AN INTERIOR LOAD BEARING OR
 NON LOAD BEARING WALL. SPECIFY THE LENGTH/EMBED DEPTH
 OF THE RED HEAD ANCHORS.
  
 15) SPECIFY THE WINDOW TYPES (IE SINGLE HUNG, CASEMENT,
 ETC.) AND SPECIFY THE REQUIRED OPENING PRESSURES.
  
 16)SHOW COMPLIANCE WITH R310 FOR EMERGENCY ESCAPE AND
 RESCUE OPENINGS REQUIRED FOR SLEEPING ROOMS.
  
 17) SUBMIT PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS
 AND STORM PANELS (IF WINDOWS ARE NOT IMPACT RATED).
 SPECIFYTHE MOUNT TYPE, ANCHOR TYPE AND ANCHOR SPACING
 FOR THE STORM PANELS.
  
 18)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE.
  
 19)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 20) ADDRESS COMMENTS OF OTHER TRADES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2008-09-05 Cont ID  
Sent By btrobaug Date 2008-09-05 Time 15:53 Rev Time 0.00
Received By btrobaug Date 2008-09-05 Time 15:43 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2008-09-02 Cont ID  
Sent By btrobaug Date 2008-09-02 Time 09:35 Rev Time 0.00
Received By btrobaug Date 2008-09-02 Time 09:14 Sent To B
Notes
2008-09-02 09:35:08 
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-07-31 Cont ID  
Sent By btrobaug Date 2008-07-31 Time 16:26 Rev Time 0.00
Received By btrobaug Date 2008-07-31 Time 16:22 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-07-08 Cont ID  
Sent By btrobaug Date 2008-07-08 Time 07:41 Rev Time 0.00
Received By btrobaug Date 2008-07-08 Time 06:57 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-01-17 Cont ID  
Sent By btrobaug Date 2008-01-17 Time 08:30 Rev Time 0.00
Received By btrobaug Date 2008-01-17 Time 08:18 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-27 Cont ID  
Sent By btrobaug Date 2007-07-27 Time 09:22 Rev Time 0.00
Received By btrobaug Date 2007-07-26 Time 06:52 Sent To M
Notes
2007-07-26 07:33:12 
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-09-05 Cont ID  
Sent By adarroug Date 2008-09-05 Time 10:59 Rev Time 0.00
Received By adarroug Date 2008-09-05 Time 10:59 Sent To E
Notes
2008-09-05 10:59:46TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-08-28 Cont ID  
Sent By tgordon Date 2008-08-28 Time 16:20 Rev Time 0.00
Received By tgordon Date 2008-08-28 Time 16:20 Sent To E
Notes
2008-08-28 16:21:07TO "ELECT" BILL T.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-07-31 Cont ID  
Sent By adarroug Date 2008-07-31 Time 12:20 Rev Time 0.00
Received By adarroug Date 2008-07-31 Time 12:20 Sent To E
Notes
2008-07-31 12:21:13TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-01 Cont ID  
Sent By adarroug Date 2008-07-01 Time 12:22 Rev Time 0.00
Received By adarroug Date 2008-07-01 Time 12:22 Sent To Z
Notes
2008-07-01 12:22:57TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-01-10 Cont ID  
Sent By spalmer Date 2008-01-10 Time 08:29 Rev Time 0.00
Received By spalmer Date 2008-01-10 Time 08:29 Sent To Z
Notes
2008-01-10 08:29:54TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-02 Cont ID  
Sent By jleech Date 2007-08-02 Time 11:23 Rev Time 0.00
Received By jleech Date 2007-07-20 Time 10:32 Sent To  
Notes
2007-07-20 10:33:39TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2008-09-08 Cont ID  
Sent By tgordon Date 2008-09-08 Time 08:49 Rev Time 0.30
Received By tgordon Date 2008-09-08 Time 08:49 Sent To P
Notes
2008-09-08 08:49:55REVISION TO MECH. PLAN.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2008-09-04 Cont ID  
Sent By tgordon Date 2008-09-04 Time 09:32 Rev Time 0.45
Received By tgordon Date 2008-09-04 Time 09:32 Sent To  
Notes
2008-09-04 09:54:23PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 REVISION TO PLANS
 *** DENIED ***
  
 1) PAGE 1 OF 2 FLOOR PLAN SHOWS AN A/C GRILL IN THE
 STUDY (SEE YELLOW HIGH LIGHT ON PLAN) PLEASE STATE IF
 GRILL IS SUPPLY, RETURN, SHOW SIZE. CFM'S. AND PROVIDE
 THE DUCT (FLEX) INFORMATION, PER 2004 WPB
 AMEND.106.3.5.4 (10).
  
 2) PLAN SHOWS AN A/C GRILL IN THE BATHROOM, PLEASE SEE
 NOTE ABOVE.
  
 3) SHOW THE CFM'S AT THE BATHROOM EXHAUST FAN, PER 2004
 FBC/R M1506.3.
  
 4) STATE ON PLAN WHERE THE BATHROOM EXHAUST FAN WILL
 TERMINATE, PER 2004 FBC/R M1506.2.
  
 5) PLAN STATES "EXISTING DOOR TO STUDY A/C RETURN" IF
 THE DOOR IS TO BE USED AS A RETURN IT MUST BE LOUVERED
 OR HAVE A TRANSFER GRILL INSTALLED (IF GRILL SHOW SIZE)
 STATE ON PLAN WHICH IS BEING USED, PER 2004 FBC/R
 M1602.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2008-08-01 Cont ID  
Sent By tgordon Date 2008-08-01 Time 08:29 Rev Time 0.30
Received By tgordon Date 2008-08-01 Time 08:29 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-07-08 Cont ID  
Sent By tgordon Date 2008-07-08 Time 08:35 Rev Time 0.30
Received By tgordon Date 2008-07-08 Time 08:35 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2008-01-17 Cont ID  
Sent By tgordon Date 2008-01-17 Time 14:44 Rev Time 0.45
Received By tgordon Date 2008-01-17 Time 14:44 Sent To P
Notes
2008-01-17 15:00:38PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2. (PLEASE SUBMIT 2
 COPY'S).
  
 2) WAS UNABLE TO FIND THE ALEN AMS09 DUCTLESS
 MINI-SPLIT A/C SYSTEM ON THE ARI DIRECTORY WEB-SITE.
 PLEASE SUBMIT THE ARI CERTIFICATE, SEE 2004 FBC
 13-607.1.ABC.3.1.1.
  
 3) PLEASE ADD AN A/C SCHEDULE WITH THE PERTINENT
 INFORMATION TO THE MECHANICAL PLAN, SEE 2004 WPB AMEND.
 106.3.5.4 (10).
  
 4) PLEASE SUBMIT DETAILED MANUFACTURER'S
 SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR THE
 A/C SYSTEM.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-07-27 Cont ID  
Sent By tgordon Date 2007-07-27 Time 09:54 Rev Time 0.25
Received By tgordon Date 2007-07-27 Time 09:54 Sent To P
Notes
2007-07-27 10:00:02*** DENIED ***
 1) THE ENGINEER WHO SEALED THE PLANS MUST ALSO HAVE
 THEIR PRINTED NAME AND LICENSE NUMBER IN THE TITLE
 BLOCK, SEE FAC 61G-15-23.002, PLEASE CORRECT.
  
 2) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC
 13-101.2.2.
  
 3) PLANS NOTE ADD 6" BATT INSULATION IN CEILING, PLEASE
 ADD WHAT THE R-VALUE WILL BE.
  
 4) PLEASE STATE ON PLANSIF THE EXISTING WATER HEATER
 IS GAS OR ELECTRIC, AND SHOW HOW IT WILL BE ACCESSED.
  
 5) MECHANICAL PERMIT #07070601 HAS BEEN APPLIED FOR AND
 APPLICATION STATES EXTEND A/C, PLEASE SUBMIT MECHANICAL
 PLAN FOR REVIEW, SEE 2004 FBC CITY OF WPB AMEND.
 106.3.5.4 #10.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 6 Status P Date 2008-09-08 Cont ID  
Sent By mperson Date 2008-09-08 Time 09:37 Rev Time 0.00
Received By mperson Date 2008-09-08 Time 09:37 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 5 Status F Date 2008-09-03 Cont ID  
Sent By mperson Date 2008-09-03 Time 16:17 Rev Time 0.00
Received By mperson Date 2008-09-03 Time 16:17 Sent To M
Notes
2008-09-03 16:40:34PLUMBING PLAN REVIEW:
 REVISION DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET 1 SANITARY RISER: PLEASE CORRECT THE FOLLOWING
 PER THE FBC-2004 PLUMBING CODE SECTIONS.
  
 A} THERE IS A 3 INCH HORIZONTAL DRY VENT BEING
 INDICATED UPSTREAM OF THE WATER CLOSET. HORIZONTAL DRY
 VENTS ARE NOT ALLOWED. PER SECTION 905.3 VENT
 CONNECTION TO DRAINAGE SYSTEM.
  
 B} LAVATORY NEEDS A VENT AND A WATER-SEAL TRAP. PER
 SECTION 901.2.1 VENTING REQUIRED AND SECTION 1002.1
 FIXTURE TRAP.
 NOTE: IF A 1-1/4" TRAP IS USED ON THE LAVATORY A
 CLEANOUT IS REQUIRED AT THE BASE OF ITS STACK (SECTION
 708.3.4 BASE OF STACK), HOWEVER IF A 1-1/2" TRAP IS
 USED PER 708.7 MINIMUM SIZE EXCEPTION (1) A CLEANOUT IS
 NOT REQUIRED.
  
 C} THE 3 INCH HORIZONTAL BRANCH AND STACK IS NOT
 CLEARLY IDENTIFIED. IS THIS FOR THE WASHING MACHINE?
 PLEASE CLARIFY THIS AND PROVIDE THE FOLLOWING FOR THE
 WASHING MACHINE.
 *SECTION 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
  
 *SECTION 802.4 STANDPIPES.STANDPIPES SHALL BE
 INDIVIDUALLY TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING.
  
 *SECTION 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM).
 CLEANOUT FOR THE WASHING MACHINE SHALL BE 3 INCH.
  
 *SECTION 708.9 ACCESS. ACCESS SHALL BE PROVIDED TO ALL
 CLEANOUTS. CLEANOUT FOR THE WASHING MACHINE SHALL BE
 LOCATED AT FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.).
  
 D} CLEARLY INDICATE A TWO-WAY CLEANOUT AT THE JUNCTION
 OF THE BUILDING DRAIN AND BUILDING SEWER. PER SECTION
 708.3.5 BUILDING DRAIN AND BUILDING SEWER JUNCTION.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 NOTE: PLEASE REFERENCE THE EXAMPLE SANITARY ISOMETRIC
 RISER DIAGRAM THAT REFLECTS THE FLOOR PLAN AND IS CODE
 COMPLIANT TO HELP IN THE REVISON ATTACHED TO THESE
 PLUMBING COMMENTS.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-08-01 Cont ID  
Sent By mperson Date 2008-08-01 Time 13:49 Rev Time 0.00
Received By mperson Date 2008-08-01 Time 13:49 Sent To B
Notes
2008-08-01 14:25:18****************PROVISO****************
 NOTE: A REVISION SHALL BE REQUIRED OF THE SANITARY
 ISOMETRIC RISER DIAGRAM THAT REFLECTS THE PROPOSED
 FLOOR PLAN BEFORE FINAL INSPECTION. THE WASHING MACHINE
 BRANCH DRAIN AND STACK SHALL BE 3 INCH AND THE CLEANOUT
 FOR THE WASHING MACHINE STACK SHALL BE LOCATED @ 4'
 A.F.F. FOR ACCESS. PER FBC-2004 PLUMBING SECTIONS 406.3
 WASTE CONNECTIONS, SECTION 701.1 SCOPE, AND SECTION
 708.9 ACCESS.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL: [email protected]

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-07-08 Cont ID  
Sent By mperson Date 2008-07-08 Time 13:09 Rev Time 0.00
Received By mperson Date 2008-07-08 Time 13:09 Sent To B
Notes
2008-07-08 13:20:59PLUMBING PLAN REVIEW:
 DENIED 3RD TIME:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 1. SHEET 1, SANITARY ISOMETRIC RISER DIAGRAM: PLEASE
 CORRECT THE FOLLOWING PER FBC-2004 PLUMBING SECTIONS.
  
  
 A} SECTION 701.1 SCOPE, 901.1 SCOPE, AND (W.P.B. AS
 AMENDED) 106.3.5.4 (9) PLUMBING: CLEARLY INDICATE THE
 SIZES TO ALL WASTE, VENTS AND WATER-SEAL TRAPS. THE
 ONLY SIZE PIPING BEING INDICATED ON THE PLANS IS 3 INCH
 BY THE CLEANOUT AND 3" VTR. IS IT THE INTENT TO HAVE
 ALL WASTE PIPING 3 INCH?
  
 B} SECTION 905.3 VENT CONNECTION TO DRAINAGE SYSTEM,
 NO HORIZONTAL DRY VENTS ARE ALLOWED (DRY VENT BETWEEN
 SHOWER AND VENT THRU ROOF NOT ALLOWED).
  
 C} SECTION 901.2.1 VENTING REQUIRED, THE WASHING
 MACHINE AND LAVATORY REQUIRE A VENT.
  
 D} SECTION 1002.3 PROHIBITED TRAPS, THE LAVATORY IS
 INDICATING A "S" TRAP WHICH IS PROHIBITED.
  
 E} SECTION 701.1 SCOPE, PLANS DO NOT CLEARLY INDICATE
 THAT THE PROPOSED BATHROOM SANITARY SYSTEM WILL TIE
 INTO THE EXISTING.
  
 F} SECTION 708.3.5 BUILDING DRAIN AND BUILDING SEWER
 JUNCTION, CLEARLY INDICATE THE CLEANOUT AT THE JUNCTION
 OF THE BUILDING DRAIN AND BUILDING SEWER AS BEING A
 TWO-WAY CLEANOUT.
  
 G} SECTION 405.3.1 WATER CLOSETS, URINALS, LAVATORIES,
 AND BIDETS. A WATER CLOSET, URINAL, LAVATORY OR BIDET
 SHALL NOT BE SET CLOSER THAN 15 INCHES (381 MM) FROM
 ITS CENTER TO ANY SIDE WALL, PARTITION, VANITY OR OTHER
 OBSTRUCTION, OR CLOSER THAN 30 INCHES (762 MM)
 CENTER-TO-CENTER BETWEEN WATER CLOSETS, URINALS OR
 ADJACENT FIXTURES. THERE SHALL BE AT LEAST A 21-INCH
 (533 MM) CLEARANCE IN FRONT OF THE WATER CLOSET, URINAL
 OR BIDET TO ANY WALL, FIXTURE OR DOOR. WATER CLOSET
 COMPARTMENTS SHALL NOT BE LESS THAN 30 INCHES (762 MM)
 WIDE OR 60 INCHES (1524 MM) DEEP. THERE SHALL BE AT
 LEAST A 21-INCH (533 MM) CLEARANCE IN FRONT OF A
 LAVATORY TO ANY WALL, FIXTURE OR DOOR (SEE FIGURE
 405.3.1 ).
 NOTE: THE LAVATORY IS NOT COMPLIANT.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-01-25 Cont ID  
Sent By jleech Date 2008-01-25 Time 09:04 Rev Time 0.00
Received By jleech Date 2008-01-25 Time 09:04 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-02 Cont ID  
Sent By jleech Date 2007-08-02 Time 10:49 Rev Time 0.00
Received By jleech Date 2007-08-02 Time 10:30 Sent To  
Notes
2007-08-02 11:14:37DENIED;
 1. SANITARY RISER DIAGRAM;
 A) AUTOMATIC CLOTHES WASHER SHALL DISCHARGE
 DOWN STREAM OF THE BATHROOM GROUP. SEE FBC-2004
 PLUMBING SECTION 909.1.
 B) SHOW TRAPS ON LAVATORY AND SHOWER.
 C) HORIZONTAL DRY VENTS ARE NOT PERMITTED.
 SEC905.3
 2. THERE MUST BE 21" IN FRONT OF THE LAVATORY. SEE
 SECTION 405.3.1.
 3. THE LINE BETWEEN THE TOILET AND THE WATER HEATER, IS
 THAT A WALL? IF SO ACCESS IS REQUIRED TO HEATER IF NOT
 IF ELECTRICMUST BE A GFI , IF GAS IT IS NOT PERMITED
 IN BATHROOM. PLEASE CLARIFY.
 4. SHOWER REQUIRES A CURB ON OPEN SIDES, NOT SHOWN. IF
 INCLOSED SHOW DOOR.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status P Date 2008-07-07 Cont ID  
Sent By choops Date 2008-07-07 Time 09:51 Rev Time 0.00
Received By choops Date 2008-07-07 Time 09:51 Sent To E
Notes
2008-07-07 09:51:55***APPROVED - RESUB #2 - RESTAMPED PLANS***
  
 PROVISOS:
 1)STRUCTURE MUST MAINTAIN INTERIOR ACCESS.
 2)NO SEPARATE DWELLING UNIT PERMITTED.
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 2 Status P Date 2008-01-14 Cont ID  
Sent By choops Date 2008-01-14 Time 11:27 Rev Time 0.00
Received By choops Date 2008-01-14 Time 11:27 Sent To E
Notes
2008-01-14 11:28:27***APPROVED - RESUB #1***
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-20 Cont ID  
Sent By choops Date 2007-07-20 Time 17:52 Rev Time 0.00
Received By choops Date 2007-07-20 Time 17:52 Sent To E
Notes
2007-07-20 17:55:48***FAILED***
  
  
 1)PLEASE PROVIDE A SITE PLAN SHOWING REMAINDER OF
 RESIDENCE.
  
 2)INTERIOR ACCESS MUST BE PROVIDED TO ALL AREAS
 WITHIN A DWELLING UNIT.
  
 3)NO SEPARATE DWELLING UNIT PERMITTED IN SF7 ZONING
 DISTRICT.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720