Plan Review Details - Permit 07070532
Plan Review Stops For Permit 07070532
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-09-06 Cont ID  
Sent By mjacobs Date 2007-09-06 Time 12:21 Rev Time 0.00
Received By mjacobs Date 2007-09-06 Time 11:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-08 Cont ID  
Sent By mjacobs Date 2007-08-08 Time 18:29 Rev Time 0.00
Received By mjacobs Date 2007-08-08 Time 16:25 Sent To PC
Notes
2007-08-08 18:29:29BUILDING PLAN REVIEW
 PERMIT: 07070532
 ADD: 1801 S. FLAGLER DR #1409
 CONT: FINE DETAILS INC.
 TEL: (561)###-####
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)FBC 2406.3 (5)SAFETY GLAZING SHALL BE INSTALLED
 IN THE SHOWER AREA. PROVDE PRODUCT APPROVALS FOR THE
 GLASS BLOCK. SHOW IN DETAIL HOW THE GLASS BLOCK WALL
 WILL BE HELD IN PLACE AND WHAT MATERIALS WILL BE USED
 TO RESTRAIN THE WALL FROM OVER-TURNING.
  
 3)SHOW ON THE DRAWINGS THE DOOR FOR THE SHOWER, OR
 STATE IF ANOTHER OPTION WILL BE USED. IF THE SHOWER
 DOOR IS GLASS, IT SHALL BE SAFETY GLAZING ALSO.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-09-06 Cont ID  
Sent By btrobaug Date 2007-09-06 Time 07:50 Rev Time 0.00
Received By btrobaug Date 2007-09-06 Time 07:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-07-30 Cont ID  
Sent By btrobaug Date 2007-07-30 Time 10:50 Rev Time 0.00
Received By btrobaug Date 2007-07-30 Time 08:11 Sent To  
Notes
2007-07-30 10:50:31 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW.
  
 1} THE DESCRIPTION OF WORK ON THE APPLICATION INDICATES
 "UPGRADING" THE ELECTRICAL PANEL. IT IS NOT CLEAR IF
 THE INTENT IS TO INSTALL A LARGER AMPERAGE PANEL.
 INDICATE THE AMPERAGE ON THE PANELON THE PLAN. NOTE:
 IF INCREASING AMPERAGE, INDICATE THE FEEDER SIZE AND
 TYPE.
  
 2} PER 210.11(C)(1), THERE MUST BE 2 SMALLAPPLIANCE
 CIRCUITS IN THE KITCHEN. THERE ARE TWO IN THE PANEL
 (5,7), BUT ONLY #5 APPEARS ON THE FLOOR PLAN CIRCUIT
 DESIGNATION. ALSO SEE 210.52(B)(1) REGARDING THE NOOK.
  
  
 3} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE
 ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. PLEASE
 LOCATE THE ALARMS ON THE DRAWING FLOOR PLAN FOR CLARITY
 IN THE FIELD, OR NOTE SECTION 313 ON THE PLAN.
  
 4} PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE
 BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE
 CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE NOTE ON
 PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-09-10 Cont ID  
Sent By mawillia Date 2007-09-10 Time 13:56 Rev Time 0.00
Received By mawillia Date 2007-09-10 Time 13:40 Sent To  
Notes
2007-09-10 13:56:35*****APPROVED*****
  
  
 ALL PREVIOUS PLAN REVIEW COMMENTS HAVE BEEN ADDRESSED;
 PLAN SHEET STAMPED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-08-07 Cont ID  
Sent By mawillia Date 2007-08-07 Time 16:53 Rev Time 0.00
Received By mawillia Date 2007-08-07 Time 16:28 Sent To  
Notes
2007-08-07 16:53:14*****DENIED*****
  
  
 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.THE REMOVAL AND/OR THE REPLACEMENT OF BUILDING
 MATERIALS & SUPPLIES SHALL NOT INTERFERE OR HINDER
 ACCESS TO OR EGRESS FROM THE 14TH FLOOR CORRIDOR OR ANY
 OTHER FLOOR IN THE BUILDING.
  
 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 5.IT IS STATED IN THE DEMOLITION PLAN THAT ALL WALL
 AND FLOOR FINISH ARE BE REMOVED IN THE BATHROOM.
 SPECIFY THE REPLACED INTERIOR FINISH MATERIAL FOR THE
 BATHROOM WALL IN TERMS OF CLASS A, CLASS B, OR CLASS
 C.
  
 6.IF THE SCOPE OF WORK HAS CAUSE FOR THE FIRE
 SPRINKLERS TO BE ALTERED OR REMODELED, A SEPARATE
 PERMIT AND PLAN WILL BE REQUIRED.
  
 7.PLEASE SHOW/DISPLAY THE UNIT SPACE'S SMOKE
 DETECTION DEVICES AS EITHER SMOKE DETECTORS OR SMOKE
 ALARMS.PLEASE BE ADVISED THAT SMOKE DETECTORS (SD)
 ARE TIED INTO THE BUILDING'S FIRE ALARM SYSTEM WHEREAS
 SMOKE ALARMS (SA) ALERT THE OCCUPANT(S) OF THE UNIT
 SPACE ONLY.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLANS EACH ITEM WAS
 ADDRESSED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-23 Time 08:53 Rev Time 0.00
Received By adarroug Date 2007-08-23 Time 08:53 Sent To  
Notes
2007-08-31 10:43:45TO "BOB"#10
2007-08-23 08:53:53WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-23 Cont ID  
Sent By adarroug Date 2007-08-08 Time 08:52 Rev Time 0.00
Received By adarroug Date 2007-07-17 Time 08:52 Sent To  
Notes
2007-07-26 14:24:03TO "BOB"#18
2007-07-19 13:43:54WAITING FOR "BOB"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-09-10 Cont ID  
Sent By jleech Date 2007-09-10 Time 15:19 Rev Time  
Received By jleech Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-09-10 Cont ID  
Sent By jleech Date 2007-09-10 Time 15:19 Rev Time 0.00
Received By jleech Date 2007-09-10 Time 15:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-08-08 Cont ID  
Sent By jleech Date 2007-08-08 Time 14:25 Rev Time 0.00
Received By jleech Date 2007-08-08 Time 13:55 Sent To  
Notes
2007-08-08 14:28:51PROVISO;
  
 NO DEAD ENDS PERMITED ON SANITARY PIPES. SEE SECTION
 704.5. PLUMBING DEMO INSPECTION REQUIRED.

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-02 Cont ID  
Sent By choops Date 2007-08-02 Time 08:38 Rev Time 0.00
Received By choops Date 2007-08-02 Time 08:38 Sent To  
Notes
2007-08-02 08:39:01*VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.