| Plan Review Stops For Permit 07070532 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-06 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-09-06 |
Time |
11:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-08 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-08 |
Time |
16:25 |
Sent To |
PC |
|
| Notes |
| 2007-08-08 18:29:29 | BUILDING PLAN REVIEW | | | PERMIT: 07070532 | | | ADD: 1801 S. FLAGLER DR #1409 | | | CONT: FINE DETAILS INC. | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)FBC 2406.3 (5)SAFETY GLAZING SHALL BE INSTALLED | | | IN THE SHOWER AREA. PROVDE PRODUCT APPROVALS FOR THE | | | GLASS BLOCK. SHOW IN DETAIL HOW THE GLASS BLOCK WALL | | | WILL BE HELD IN PLACE AND WHAT MATERIALS WILL BE USED | | | TO RESTRAIN THE WALL FROM OVER-TURNING. | | | | | | 3)SHOW ON THE DRAWINGS THE DOOR FOR THE SHOWER, OR | | | STATE IF ANOTHER OPTION WILL BE USED. IF THE SHOWER | | | DOOR IS GLASS, IT SHALL BE SAFETY GLAZING ALSO. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-06 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-06 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-30 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-30 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2007-07-30 10:50:31 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE DESCRIPTION OF WORK ON THE APPLICATION INDICATES | | | "UPGRADING" THE ELECTRICAL PANEL. IT IS NOT CLEAR IF | | | THE INTENT IS TO INSTALL A LARGER AMPERAGE PANEL. | | | INDICATE THE AMPERAGE ON THE PANELON THE PLAN. NOTE: | | | IF INCREASING AMPERAGE, INDICATE THE FEEDER SIZE AND | | | TYPE. | | | | | | 2} PER 210.11(C)(1), THERE MUST BE 2 SMALLAPPLIANCE | | | CIRCUITS IN THE KITCHEN. THERE ARE TWO IN THE PANEL | | | (5,7), BUT ONLY #5 APPEARS ON THE FLOOR PLAN CIRCUIT | | | DESIGNATION. ALSO SEE 210.52(B)(1) REGARDING THE NOOK. | | | | | | | | | 3} R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS. | | | WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS | | | REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING | | | ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE | | | INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE | | | ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE | | | ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. PLEASE | | | LOCATE THE ALARMS ON THE DRAWING FLOOR PLAN FOR CLARITY | | | IN THE FIELD, OR NOTE SECTION 313 ON THE PLAN. | | | | | | 4} PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE | | | BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE | | | CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE NOTE ON | | | PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-10 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-10 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2007-09-10 13:56:35 | *****APPROVED***** | | | | | | | | | ALL PREVIOUS PLAN REVIEW COMMENTS HAVE BEEN ADDRESSED; | | | PLAN SHEET STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-07 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-07 |
Time |
16:28 |
Sent To |
|
|
| Notes |
| 2007-08-07 16:53:14 | *****DENIED***** | | | | | | | | | 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.THE REMOVAL AND/OR THE REPLACEMENT OF BUILDING | | | MATERIALS & SUPPLIES SHALL NOT INTERFERE OR HINDER | | | ACCESS TO OR EGRESS FROM THE 14TH FLOOR CORRIDOR OR ANY | | | OTHER FLOOR IN THE BUILDING. | | | | | | 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 5.IT IS STATED IN THE DEMOLITION PLAN THAT ALL WALL | | | AND FLOOR FINISH ARE BE REMOVED IN THE BATHROOM. | | | SPECIFY THE REPLACED INTERIOR FINISH MATERIAL FOR THE | | | BATHROOM WALL IN TERMS OF CLASS A, CLASS B, OR CLASS | | | C. | | | | | | 6.IF THE SCOPE OF WORK HAS CAUSE FOR THE FIRE | | | SPRINKLERS TO BE ALTERED OR REMODELED, A SEPARATE | | | PERMIT AND PLAN WILL BE REQUIRED. | | | | | | 7.PLEASE SHOW/DISPLAY THE UNIT SPACE'S SMOKE | | | DETECTION DEVICES AS EITHER SMOKE DETECTORS OR SMOKE | | | ALARMS.PLEASE BE ADVISED THAT SMOKE DETECTORS (SD) | | | ARE TIED INTO THE BUILDING'S FIRE ALARM SYSTEM WHEREAS | | | SMOKE ALARMS (SA) ALERT THE OCCUPANT(S) OF THE UNIT | | | SPACE ONLY. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLANS EACH ITEM WAS | | | ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-23 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-23 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2007-08-31 10:43:45 | TO "BOB"#10 | | 2007-08-23 08:53:53 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-08 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-17 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2007-07-26 14:24:03 | TO "BOB"#18 | | 2007-07-19 13:43:54 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-09-10 |
Time |
15:19 |
Rev Time |
|
| Received By |
jleech |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-09-10 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-09-10 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-08 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-08 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2007-08-08 14:28:51 | PROVISO; | | | | | | NO DEAD ENDS PERMITED ON SANITARY PIPES. SEE SECTION | | | 704.5. PLUMBING DEMO INSPECTION REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-02 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-02 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2007-08-02 08:39:01 | *VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|