| Plan Review Stops For Permit 07070447 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-03-05 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-03-05 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2008-03-05 10:10:41 | SHEETS A-4 AND A-5 OF PLANS WERE REVISED. | | | | | | BUILDING PROVISO | | | | | | SUBMIT THE LETTER WITH CALCULATIONS FOR THE NEW 2X12 | | | BEAM AS NOTED ON SHEET A-5 OF THE REVISED PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2008-02-06 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2008-02-06 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2008-02-06 14:23:57 | 2004 FBC W/2007 REVISIONS | | | | | | THE REVISION TO ADD 2 X 6 BEARING WALL AND NEW BEAM IS | | | DENIED | | | | | | 1) ON SHEET A-4 THE NEW 2 X 6 BEARING WALL IS SPECIFIED | | | AS AN EXISTING WALL ACCORDING TO THE WALL LEGEND. | | | PLEASE REVISE. 2004 FBC 106.1.3* CITY AMENDMENTS. | | | | | | 2) ON SHEET A-2 THE 2 X 6 BEARING WALL IS SPECIFIED AS | | | A 4" WALL. IT WILL NEED TO BE REVISED. 2004 FBC | | | 106.1.3* CITY AMENDMENTS | | | | | | 3) ON SHEET A-5 THE NEW ROOF GIRDER BEAM IS SPECIFIED | | | AS 3 - 2 X 10S AND IN THE CONNECTOR SCHEDULE A SIMPSON | | | LGUM 210-2, WHICH IS FOR A TWO MEMBER GIRDER IS | | | SPECIFIED. PLEASE CORRECT. 2004 FBC 106.1.1* CITY | | | AMENDMENTS. | | | | | | 4) SUBMIT SIGNED AND SEALED CALCULATIONS FROM THE | | | ENGINEER SHOWING THAT THE 3 -2 X 10 GIRDER SPANNING | | | MORE THAN 15 FEET IS ADEQUATE TO RESIST THE ROOF LIVE | | | AND DEAD LOADS WITH THE CEILING ATTACHED. 2004 FBC | | | 106.1.2* CITY AMENDMENTS. | | | | | | 5) SPECIFY THE CONNECTORS THAT WILL BE USED TO ATTACH | | | THE NEW TRUSSES AND RAFTERS TO THE 2 X 6 BEARING WALL. | | | 2004 FBC 106.1.3* CITY AMENDMENTS. | | | | | | 6)PROVIDE A DETAIL OF THE 2 X 6 BEARING WALL | | | SPECIFYING THE CONNECTORS, ANCHOR BOLTS, ETC. THAT WILL | | | BE USED TO PROVIDE A CONTINUOUS LOAD PATH. FBC R601.2 | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-11-01 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-11-01 |
Time |
11:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-26 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-11-01 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2007-10-26 11:38:33 | DENIED BY BUILDING | | | | | | 1) SUBMIT PRODUCT APPROVAL FOR THE WINDOW MULLIONS THAT | | | HAS BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SEE FBC 106.3.3 CITY AMENDMENTS. | | | | | | 2) ADDRESS MECHANICAL REVIEW COMMENTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-17 |
Time |
17:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-10-17 |
Time |
17:41 |
Sent To |
|
|
| Notes |
| 2007-10-17 17:41:04 | 2004 FBC W/2007 REVISIONS | | | ADDITION | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED | | | BY THE PREPARER. SEE FBC 13-103.1.1. | | | | | | 4) SUBMIT PRODUCT APPROVALS FOR THE STRUCTURAL WINDOW | | | MULLIONS. | | | | | | 5) THE SOIL REPORT INDICATES THAT THE SOIL IS NOT | | | ADEQUATE TO SUPPORT THE ADDITION. PLEASE INDICATE ON | | | THE PLANS HOW THE INADEQUATE SOIL WILL BE CORRECTED. | | | SPECIFY WHICH ONE OF THE RECOMMENDED METHODS WILL BE | | | USED AND PROVIDE PLANS. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-07-31 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-07-31 |
Time |
11:17 |
Sent To |
P |
|
| Notes |
| 2007-07-31 14:19:01 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT | | | MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) SHOW COMPLIANCE WITH R322.2.2, WHICH REQUIRES AT | | | LEAST ONE BATHROOM WITH A DOOR THAT HAS A 29" CLEAR | | | OPENING. THE DOOR TO THE WATER CLOSET IN THE NEW MASTER | | | BATHROOM DOES NOT COMPLY. | | | | | | 4) ON SHEET A1 THE DESIGN DATA SPECIFIES THE INTERNAL | | | PRESSURE COEFFICIENT AS N/A. SEE THE WIND DESIGN DATA | | | ON SHEET A5. PLEASE CORRECT. | | | | | | 5) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS . | | | IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF | | | CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED | | | TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) | | | AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR | | | GREATER. THE ROUGH-FRAMED OPENING SHALL NOT BE LESS | | | THAN 22 INCHES BY 30 INCHES (559 MM BY 762 MM) AND | | | SHALL BE LOCATED IN A HALLWAY OR OTHER READILY | | | ACCESSIBLE LOCATION. A 30-INCH (762 MM) MINIMUM | | | UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE | | | PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE | | | SECTION M1305.1.3 FOR ACCESS REQUIREMENTS WHERE | | | MECHANICAL EQUIPMENT IS LOCATED IN ATTICS. | | | | | | 6) SUBMIT ENERGY CALCULATIONS FOR THE ADDITION AS | | | REQUIRED BY FBC CHAPTER 13. | | | | | | 7) SOME OF THE NOTES AND PARTS OF THE FOOTING SCHEDULE | | | ON SHEET A4 ARE ILLEGIBLE. | | | | | | 8) DETAIL 5 ON A4 SPECIFIES A MINIMUM FOOTING THICKNESS | | | OF 16" AND THE FOOTING SCHEDULE SPECIFIES AN 18" THICK | | | FOOTING. PLEASE CORRECT. | | | | | | 9) PLEASE UPDATE THE MASONRY NOTES ON A4 TO TMS 402-02 | | | AND TMS 602-02, WHICH ARE THE EDITIONS REFERENCED BY | | | THE 2004 FBC RESIDENTIAL IN CHAPTER 43. | | | | | | 10) REVISE THE ROOF NOTES IN DETAILS 1, 2 AND 3 0N A5 | | | TO SPECIFY 8D RING SHANK NAILS FOR FASTENING THE ROOF | | | SHEATHING. | | | | | | 11) THE UPLIFT PRESSURES FOR ROOF ZONES 1, 2 AND 3 | | | SPECIFIED ON A5 FOR A 100 SQFT EFFECTIVE WIND AREA ARE | | | INCORRECT. SEE TABLE R301.2(2). THE UPLIFT PRESSURES | | | FOR ROOFING SHOULD USE THE 10 SQFT EFFECTIVE WIND | | | PRESSURES FROM THE TABLE. THE ROOF SLOPE SHOULD BE | | | SPECIFIED BECAUSE IT IS REQUIRED TO DETERMINE THE | | | PRESSURES. | | | | | | 12) THE WALL COMPONENT AND CLADDING PRESSURE FOR ZONE 4 | | | ON A5 OF 38.2 SHOULD BE EXPRESSED AS A NEGATIVE INSTEAD | | | OF POSITIVE. PLEASE CORRECT. | | | | | | 13) SPECIFY THE LENGTH/EMBED DEPTH OF THE TAPCONS | | | SPECIFIED IN DETAIL 4 ON S5. ALSO SPECIFY THAT THE | | | MANUFACTURER OF THESE CONNECTORS IS "USP". | | | | | | 14)PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. | | | | | | 15)WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 16) SUBMIT PRODUCT APPROVALS FOR THE GLASS BLOCK AND | | | WINDOW MULLIONS. | | | | | | 17) THE WINDOW AND DOOR PRESSURES SPECIFIED ON THE | | | ELEVATIONS ON SHEET A3 ARE HIGHER THAN THE MAXIMUM | | | PRESSURES SPECIFIED ON SHEET A5. PLEASE CORRECT. | | | | | | 18)FBC* 1804.2.2AREA OF QUESTIONABLE | | | SOIL.SUBMIT A GEOTECHNICAL REPORT | | | TO VERIFY THE SAFE BEARING CAPACITY OF | | | THE SOIL. | | | | | | 19) SPECIFY THE REQUIRED SOIL BEARING CAPACITY FOR THE | | | STRUCTURE ON THE PLANS. | | | | | | 20) THE VALUE OF THE PROJECT HAS BEEN INCREASED BASED | | | ON ICC VALUATION DATA AND RADON FEES HAVE BEEN ADDED. | | | FEES OF $ 56.26 ARE DUE. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-18 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-18 |
Time |
15:34 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-19 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-19 |
Time |
06:40 |
Sent To |
M |
|
| Notes |
| 2007-07-19 07:56:22 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | | | 2} PROVIDE A PANEL SCHEDULE PER 408.4. INCLUDE OCP AND | | | CONDUCTOR SIZES. | | | | | | 3} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III, | | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. | | | SMALL APPLIANCE CIRCUITS @ 1500 VA EACH, 2 MINIMUM, | | | 220.52(A). | | | | | | 4} } PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 5} THE RISER DIAGRAM IS NOT CLEAR. INDICATE IF THERE IS | | | A METER/ MAIN OR A DISCONNECT DRAWN AS "2P "A". IF A | | | DISCONNECT IS LOCATED AT THE METER, AN EQUIPMENT GROUND | | | PER 250.122 MUST BE RAN WITH THE PANEL FEEDER. | | | | | | 6} SEE 250.52(A)(3) FOR FOOTER STEEL, INCLUDE AS PART | | | OF THE REQUIRED GEC SYSTEM WHEN RELOCATING THE SERVICE | | | AND PUTTING AN ADDITION ON, AS THE FOOTER STEEL IS | | | "AVAILABLE". | | | | | | 7} R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED | | | IN NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT. LOCATE ON | | | PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-06 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-06 |
Time |
10:46 |
Sent To |
B |
|
| Notes |
| 2008-02-06 10:47:13 | TO "RMCDOUGAL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-30 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-30 |
Time |
17:03 |
Sent To |
B |
|
| Notes |
| 2007-10-30 17:03:48 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-18 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-18 |
Time |
15:57 |
Sent To |
M |
|
| Notes |
| 2007-10-18 15:58:06 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-13 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-13 |
Time |
09:00 |
Sent To |
Z |
|
| Notes |
| 2007-09-13 09:01:17 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-02 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-17 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2007-07-17 14:03:30 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-19 |
Time |
13:51 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2008-03-19 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2008-03-19 13:52:46 | REVISION TO MECH. PLAN M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-10-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-31 |
Time |
09:47 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-10-31 |
Time |
09:47 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-25 |
Time |
08:04 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-10-25 |
Time |
08:04 |
Sent To |
B |
|
| Notes |
| 2007-10-25 08:14:48 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | | | | 1) AS NOTED IN LAST REVIEW 9-19-07 NOTE #2. ENERGY | | | CALCULATIONS LINE 15 IS TAKING CEILING FAN CREDIT, SEE | | | FBC 13-607.2.A.3.1 CEILING FAN CREDIT MAY BE TAKEN IF | | | ONE OR MORE CEILING FANS ARE INSTALLED IN EACH OF THE | | | BEDROOMS AND A MINIMUM OF ONE CEILING FAN IS INSTALLED | | | IN ALL PRIMARY LIVING AREAS (LIVING ROOMS, FAMILY | | | ROOMS, OR GREAT ROOMS). PLEASE SHOW ON ELECTRICAL PLAN | | | EXISTING CEILING FANS IN ALL REQUIRED ROOMS IF THEY | | | EXIST OR REMOVE CREDIT FROM ENERGY CAL'S. | | | | | | 2) AS NOTED IN LAST REVIEW 9-19-07 NOTE #3. I COULD NOT | | | VERIFY THE A/C EQUIPMENT LISTED ON MECHANICAL PLAN WITH | | | THE ARI DIRECTORY WEB-SITE, PLEASE SUBMIT ARI LISTING, | | | SEE FBC 13-607.1.ABC.3.1.1. | | | | | | 3) THE DUCT DESIGN MUST BE PART OF THE PLAN AND CAN NOT | | | BE ADDED BY HAND TO SOME OTHER PLAN, PLEASE SUBMIT A | | | PROPER MECHANICAL PLAN (NO PENCIL, PEN, WHITE-OUT, AND | | | NO HAND CHANGES), SEE W.P.B. AMEND. 106.1.3.. | | | | | | 4) SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING FOUR | | | TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-19 |
Time |
14:24 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-09-19 |
Time |
14:24 |
Sent To |
P |
|
| Notes |
| 2007-09-19 15:01:48 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY THE | | | PREPARER, SEE FBC 13-103.1.1. | | | | | | 2) ENERGY CALCULATIONS LINE 15 IS TAKING CEILING FAN | | | CREDIT, SEE FBC 13-607.2.A.3.1 CEILING FAN CREDIT MAY | | | BE TAKEN IF ONE OR MORE CEILING FANS ARE INSTALLED IN | | | EACH OF THE BEDROOMS AND A MINIMUM OF ONE CEILING FAN | | | IS INSTALLED IN ALL PRIMARY LIVING AREAS (LIVING ROOMS, | | | FAMILY ROOMS, OR GREAT ROOMS). PLEASE SHOW ON | | | ELECTRICAL PLAN EXISTING CEILING FANS IN ALL REQUIRED | | | ROOMS IF THEY EXIST OR REMOVE CREDIT FROM ENERGY | | | CAL'S. | | | | | | 3) I COULD NOT VERIFY THE A/C EQUIPMENT LISTED ON | | | MECHANICAL PLAN WITH THE ARI DIRECTORY WEB-SITE TO | | | CHECK SEER AND THAT IT IS A HEAT PUMP, PLEASE SUBMIT | | | ARI LISTING AND DETAILED MANUFACTURER'S SPECIFICATION'S | | | AND INSTALLATION INSTRUCTIONS FOR A/C SYSTEM. | | | | | | 4) THE MECHANICAL PLAN SUBMITTED HAS TO MUCH FLOOR PLAN | | | DETAIL ON IT AND IS DIFFICULT TO READ. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY. PER 2004 FBC | | | 106.1.1. | | | | | | 5) THE DUCT DESIGN MUST BE PART OF THE PLAN AND CAN NOT | | | BE ADDED BY HAND TO SOME OTHER PLAN, PLEASE SUBMIT A | | | PROPER MECHANICAL PLAN. | | | | | | 6) AN EXHAUST FAN IS REQUIRED IN THE MASTER BATHROOM | | | TUB AND SHOWER AREA, SEE RES.R303.3. | | | | | | 7) THE EXISTING BATHROOM REQUIRES A EXHAUST FAN , SEE | | | RES. R303.3. | | | | | | 8) PROVIDE FOR RETURN AIR TO THE EXISTING PART OF THE | | | HOUSE IF THE FAMILY ROOM DOORS WERE CLOSED, SEE RES. | | | M1602.4. | | | | | | 9) MECHANICAL PLAN WILL NEED TO BE SIGNED AND SEALED BY | | | THE ENGINEER AS HIS INFORMATION IS IN THE TITLE BLOCK, | | | IF HIS INFORMATION WAS NOT IN THE TITLE BLOCK THEN IT | | | WOULD NEED THE PREPARERS INFORMATION AND SIGNATURE, SEE | | | WPB 106.1.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] | | | . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-19 |
Time |
09:44 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-07-19 |
Time |
09:44 |
Sent To |
P |
|
| Notes |
| 2007-07-19 09:52:37 | *** DENIED *** | | | 1) MECHANICAL PERMIT 07070449 APPLIED FOR BUT NO | | | MECHANICAL PLANS SUBMITTED FOR REVIEW. | | | | | | 2) PLEASE SUBMIT MECHANICAL PLANS FOR REVIEW (BUILDING | | | PLANS SHOW A NEW A/C SYSTEM TO BE INSTALLED). | | | | | | 3) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC | | | 13-101.2.2. | | | | | | 4) PLEASE SUBMIT COOLING LOAD CALCULATIONS, SEE 2004 | | | FBC 13-607.1.ABC.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-12 |
Time |
07:35 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-12 |
Time |
07:35 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-02 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-02 |
Time |
09:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-18 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-18 |
Time |
08:38 |
Sent To |
E |
|
| Notes |
| 2007-09-18 08:41:38 | ***APPROVED - RESUB #1*** | | | | | | PROVISO:AS THE VALUE OF THE PROPOSED WORK EXCEEDS 50% | | | OF THE VALUE OF THE HOME, THE SITES LANDSCAPING SHALL | | | BE BROUGHT TO CURRENT REGULATIONS, IF NOT ALREADY. | | | PURSUANT TO SECTION 94-442(B)(2)(A):FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-18 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-18 |
Time |
13:14 |
Sent To |
E |
|
| Notes |
| 2007-07-18 13:17:21 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE 2 COPIES OF A CURRENT SURVEY | | | SHOWING SCOPE OF WORK WITH DIMENSIONS AND SETBACK | | | DIMENSIONS TO SIDE AND REAR PROPERTY LINES FROM | | | PROPOSED ADDITION. | | | | | | 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO THE PROPERTY LINES ON THE SURVEYS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|