Plan Review Details - Permit 07070438
Plan Review Stops For Permit 07070438
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2008-01-25 Cont ID  
Sent By rmcdouga Date 2008-01-25 Time 11:30 Rev Time 0.00
Received By rmcdouga Date 2008-01-25 Time 07:12 Sent To E
Notes
2008-01-25 11:04:022004 FBC W/2007 REVISIONS
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE
 SIGNED BY THE OWNER/AGENT. SEE FBC CHAPTER 13-6.
  
 4)THE ENERGY CALCULATIONS SPECIFY THE CEILING
 INSULATION AS R-30. THE SINGLE ASSEMBLY 2 X 6 FLAT ROOF
 ABOVE HIS CLOSET DOES NOT HAVE ENOUGH SPACE FOR R-30
 INSULATION. PLEASE REVISE THE ENERGY CALCS. SEE FBC
 CHAPTER 13-6.
  
 5) THE ROOF ZONES COMPONENT AND CLADDING FIGURE ON
 SHEET 2 IS INCORRECT. THE CORNERS OF THE HIP ROOF IS
 ZONE 3. SEE FIGURE R301.2(8).
  
 6) SUBMIT PRODUCT APPROVALS FOR THE ROOFING MATERIAL
 FOR THE FLAT ROOF. FAC RULE 9B-72
  
 7) SUBMIT 2 COPIES OF THE PRODUCT APPROVALS. FBC 106.1*
 CITY AMENDMENTS
  
 8) SPECIFY WHAT METHOD OF ATTACHMENT WILL BE USED TO
 INSTALL THE ROOF TILES. CIRCLE THE ATTACHMENT METHOD
 THAT WILL BE USED FROM THE ONES LISTED IN THE PRODUCT
 APPROVAL. SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES
 AND FASTENING OPTION THAT WILL BE USED TO INSTALL THE
 ROOFING MATERIAL FOR THE FLAT ROOF SECTION. IF ENHANCED
 FASTENING IS REQUIRED IN ORDER TO INCREASE THE DESIGN
 PRESSURES FOR THE PERIMETER AND CORNER AREAS, THEN
 SUBMIT RAS 117 CALCULATIONS (IF THIS IS ALLOWED BY
 LIMITATION #7 OF THE NOA). FBC 106.1.2* CITY
 AMENDMENTS.
  
 9)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. THE ENGINEER IS REQUIRED
 TO REVIEW AND APPROVE IN WRITING BOTH COPIES OF THE
 PRODUCT APPROVALS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2008-01-25 Cont ID  
Sent By rmcdouga Date 2007-08-01 Time 07:25 Rev Time 0.00
Received By rmcdouga Date 2007-07-31 Time 17:28 Sent To P
Notes
2007-08-01 07:25:28DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) SUBMIT ENERGY CALCULATIONS FOR THE NEW ADDITION AS
 REQUIRED BY FBC CHAPTER 13.
  
 4) SHOW COMPLIANCE WITH R 322.1.1, WHICH REQUIRES AT
 LEAST ONE BATHROOM WITH A DOOR THAT HAS A 29" CLEAR
 OPENING, MEASURED FROM THE FACE OF THE DOOR TO THE
 OPPOSITE STOP WITH DOOR OPEN 90 DEGREES.
  
 5) THE ROOF ZONES COMPONENT AND CLADDING FIGURE ON
 SHEET 2 IS INCORRECT. SEE FIGURE R301.2(8).
  
 6) SPECIFY THE OVERHANG FOR THE FLAT ROOF AT HIS
 CLOSET. SHOW COMPLIANCE WITH R320.7 PROTECTION AGAINST
 DECAY AND TERMITES.
 CONDENSATE LINES AND ROOF DOWNSPOUTS SHALL DISCHARGE AT
 LEAST 1 FOOT (305 MM) AWAY FROM THE STRUCTURE SIDEWALL,
 WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS OR
 SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON
 ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 MM)
 HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON
 A ROOF ABOVE ANOTHER ROOF.
  
 7) PROVIDE A WALL SECTION FOR THE SINGLE ASSEMBLY FLAT
 ROOF AT HIS CLOSET. SPECIFY THE ATTIC VENTING AND
 INSULATION. SEE R806.
  
 8) SPECIFY THE STEEL REINFORCING FOR THE 16" X 16"
 FOOTING AT THE INTERIOR LOAD BEARING WALL.
  
 9) SPECIFY THE TRUSS AND RAFTER CONNECTORS AT THE
 INTERIOR BEARING WALL.
  
 10) INDICATE HOW ATTIC VENTILATION AS REQUIRED BY R806
 WILL BE PROVIDED AT THE PORCH AREA. SEE PORCH SECTION 2
 ON 3.
  
 11) THE PORCH SECTIONS ON SHEET 3 HAVE AN OPTION OF
 USING 5/8" T&G PLYWOOD WITH GROOVES 6" OC. THE PLYWOOD
 USED FOR ROOF SHEATHING IS REQUIRED TO COMPLY WITH
 R803.2.1 AND TABLE R503.2.1.1(1) FOR SPANS AND LOADS.
  
 12) SUBMIT PRODUCT APPROVALS FOR WINDOWS, DOORS, STORM
 PANELS, ROOFING MATERIAL FOR THE FLAT AND SLOPED
 ROOFS.
  
 13) SPECIFY WHAT METHOD OF ATTACHMENT WILL BE USED TO
 INSTALL THE ROOF TILES. CIRCLE THE ATTACHMENT METHOD
 THAT WILL BE USED FROM THE ONES LISTED IN THE PRODUCT
 APPROVAL. SPECIFY WHICH ONE OF THE APPROVED ASSEMBLIES
 AND FASTENING OPTION THAT WILL BE USED TO INSTALL THE
 ROOFING MATERIAL FOR THE FLAT ROOF SECTION. IF ENHANCED
 FASTENING IS REQUIRED IN ORDER TO INCREASE THE DESIGN
 PRESSURES FOR THE PERIMETER AND CORNER AREAS, THEN
 SUBMIT RAS 117 CALCULATIONS (IF THIS IS ALLOWED BY
 LIMITATION #7 OF THE NOA).
  
 14) IN ADDITION TO THE STORM PANEL PRODUCT APPROVAL (IF
 NOT USING IMPACT RATED GLASS), SUBMIT A KEY PLAN AND
 INSTALLATION SCHEDULE. SPECIFY THE MOUNT TYPE, ANCHOR
 TYPE AND SPACING, EDGE DISTANCE, ETC. THAT WILL BE USED
 TO INSTALL THE STORM PANELS.
  
 15)PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE.
  
 16)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 17) THE WALL SECTION ON SHEET 2 SPECIFIES SHINGLES AND
 THE PORCH SECTION ON SHEET 3 SPECIFIES TILES PLEASE
 CORRECT.
  
 18) THE VALUE OF THE WORK HAS BEEN INCREASED TO $
 73,769.00 BASED ON ICC VALUATION DATA. ADDITIONAL
 PERMIT FEES AND RADON FEES ARE DUE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2008-01-25 Cont ID  
Sent By btrobaug Date 2008-01-25 Time 14:48 Rev Time 0.00
Received By btrobaug Date 2008-01-25 Time 14:43 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-18 Cont ID  
Sent By btrobaug Date 2007-07-18 Time 13:37 Rev Time 0.00
Received By btrobaug Date 2007-07-18 Time 13:10 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-01-10 Cont ID  
Sent By mmiller Date 2008-01-10 Time 15:19 Rev Time 0.00
Received By mmiller Date 2008-01-10 Time 15:19 Sent To Z
Notes
2008-01-10 15:19:31SENT TO CHRIS HOOP'S DESK MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-02 Cont ID  
Sent By jleech Date 2007-08-02 Time 10:16 Rev Time 0.00
Received By jleech Date 2007-07-17 Time 08:36 Sent To  
Notes
2007-07-17 08:43:04TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-01-14 Cont ID  
Sent By tgordon Date 2008-01-14 Time 10:47 Rev Time 0.30
Received By tgordon Date 2008-01-14 Time 10:47 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-07-18 Cont ID  
Sent By tgordon Date 2007-07-18 Time 15:41 Rev Time 0.20
Received By tgordon Date 2007-07-18 Time 15:40 Sent To P
Notes
2007-07-18 15:47:47*** DENIED ***
 1) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC
 13-101.2.2.
  
 2) PLEASE SUBMITCOOLING LOAD CALCULATIONS, SEE 2004
 FBC 13-607.1.ABC.1.
  
 3) PLEASE SUBMIT MECHANICAL PLANS (A/C) FOR REVIEW,AS
 BUILDING PLANS SHOW A NEW A/C SYSTEM FOR THE ADDITION,
 SEE 2004 FBC, CITY WPB AMEND. 106.3.5.4 (10).
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-01-16 Cont ID  
Sent By rmcdouga Date 2008-01-25 Time 11:04 Rev Time 0.00
Received By jleech Date 2008-01-16 Time 08:30 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-08-02 Cont ID  
Sent By jleech Date 2007-08-02 Time 10:16 Rev Time 0.00
Received By jleech Date 2007-08-02 Time 10:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2008-01-14 Cont ID  
Sent By choops Date 2008-01-14 Time 10:17 Rev Time 0.00
Received By choops Date 2008-01-14 Time 10:17 Sent To M
Notes
2008-01-14 10:19:12***FAILED - RESUB #1***
  
  
 REPEAT COMMENT:
  
 1)PLEASE PROVIDE 2 CLEAR COPIES OF A CURRENT SURVEY
 (I MADE COPIES FOR YOU, PLEASE USE THESE TO INDICATE
 THE IMPROVEMENTS)WITH THE SCOPE OF WORK CLEARLY
 INDICATED ON THEM, WITH DIMENSIONS AND SETBACK
 DIMENSIONS TO ALL PROPERTY LINES.INCLUDE SETBACK
 DIMENSIONS FROM PORCH TO PROPERTY LINES.SETBACK
 DIMENSIONS PROVIDED ARE NOT LEGIBLE.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS,
 ZONING TECHNICIAN (561)805-6720
  
  
  
  
 SENT TO "M" - TG

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-18 Cont ID  
Sent By choops Date 2007-07-18 Time 15:10 Rev Time 0.00
Received By choops Date 2007-07-18 Time 15:10 Sent To M
Notes
2007-07-18 15:18:27***FAILED***
  
  
 1)PLEASE PROVIDE 2 CLEAR COPIES OF A CURRENT SURVEY
 (I MADE COPIES FOR YOU)WITH THE SCOPE OF WORK CLEARLY
 INDICATED ON THEM, WITH DIMENSIONS AND SETBACK
 DIMENSIONS TO THE PROPERTY LINES.INCLUDE SETBACK
 DIMENSIONS FROM PORCH TO PROPERTY LINES.
  
 2)PROVIDE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO PROPERTY LINES.
  
 3)ALL OVERHANG DIMENSIONS TO BE SHOWN FROM THE WALL
 TO THE OUTERMOST POINT OF ROOF'S EDGE.
  
 4)PROVIDE ELEVATION DIMENSIONS FROM GRADE.
  
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720