Plan Review Details - Permit 07070352
| Plan Review Stops For Permit 07070352 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-02-26 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-02-26 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-07-14 |
Time |
09:11 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-07-14 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2008-07-14 09:12:36 | REVISION# 3ID-2A |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-21 |
Time |
14:28 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2008-04-21 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-28 |
Time |
15:44 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-12-28 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-29 |
Time |
08:01 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2007-11-29 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2007-11-29 08:13:06 | GOODRICH LLC CITY PL. TOWER SUITE # 1000 | | | BUILDING PLAN REVIEW | | | PERMIT: 07070352 | | | ADD: 525 OKEECHOBEE BLVD # 1000 | | | CONT: DAVIS GENERAL CONTRACTING CORP | | | TEL: (561) 820-1400 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) NOTE OF REFRENECE ONLY, BASED ON THE DETERMINATION | | | OF THE BUILDING OFFICIAL, APPLICATION FOR TENANT | | | IMPROVEMENT PRIOR TO C.O. WILL REQUIRE SHOP DRAWING | | | REVIEW BY THE BASE BUILDING DESIGN TEAM, THE DESIGNER | | | OF RECORD. PLEASE HAVE THE BASE BUILDING DESIGNERS OF | | | RECORD REVIEW YOUR PLANS AND IF FOUND SUFFICIENT AFFIX | | | THEIR SHOP DRAWING STAMP ON YOUR DOCUMENTS. | | | NOTE ALSO THAT A TENANT CAN NOT ACHIEVE A CERTIFICATE | | | OF OCCUPANCY BEFORE THE SHELL BUILDING HAS RECEIVED | | | THEIR CERTIFICATE OF COMPLETION. FBC 106.1.2* | | | ADMINISTRATIVE CODE. | | | | | | 3)NOTE OF REFRENECE ONLY, PLEASE NOTE AT THIS TIME | | | THIS BUILDING HAS NOT RECEIVED A CERTIFICATE OF | | | COMPLETION, AND THE ENERGY CALCULATIONS ARE BASED ON A | | | SHELL BUILDING AND ARE BASED ON 13-101.1.6. UNLESS THE | | | BUILDING IS COMPLETED AS PER ALL ASSUMPTIONS MADE IN | | | THE ORIGINAL CODE COMPLIANCE SUBMITTAL, REVISED CODE | | | SUBMITTALS USING METHOD A, B OR C SHALL BE SUBMITTED | | | WHEN THE COMPLETION OF THE BUILDING (OR PART) OF A | | | BUILDING IS PERMITTED. | | | | | | 4-6A) COMPLIED. | | | | | | 6B) 2ND REQUEST,SHEET ID-1A ALSO INDICATES THE TENANT | | | SEPERATION WALLS TO BE EXISTING DEMISSING WALL.THE | | | BASE SHELL BUILDING PLAN DOESN'T INDICATE ANY SUCH WALL | | | IN THE MOST RECENT SET OF REVISIONS SHEET A1.07 | | | REVISION# 15 DATED 6/13/07. SECTION 708.1(5) REQUIRES | | | FIRE PARTITIONS BETWEEN TENANTS. 708.3 FIRE RESISTANCE | | | RATING WILL REQUIRE A 1-HOUR FIRE RATING. | | | FLORIDA STATE STATUTE 481.2131 INTERIOR DESIGNER CAN | | | NOT DESIGN PLANS OR PORTIONS OF THAT EFFECT FIRE-RATED | | | SEPERATIONS BETWEEN INTERIOR SPACES, THE FIRM IS | | | WORKING OUT OF THE SCOPE OF THEIR LOCENSE. SEE | | | ATTACHMENT 481.2131. A FLORIDA LICENSED ARCHITECT WILL | | | NEED TO DESIGN ALL COMPONENTS THAT WILL REQUIRE FIRE | | | RATED WALLS, CEILINGS AS WELL AS THE PENETRATIONS | | | THROUGH SUCH RATED ASSEMBLIES. | | | SHEET 1D-1A NOW INDICATE A RATED CEILING IN THE IT OR | | | SERVER ROOM & THE ELECTRIC ROOM 127 BUT NO ASSEMBLY HAS | | | BEEN CALLED OUT, AGAIN WORKING OUT OF THE SCOPE OF | | | LICENSURE FL SS 481.2131. | | | THIS PERMIT IS A STAND ALONE PERMIT AND THE WORK TO BE | | | COMPLETED UNDER THIS PERMIT, EVEN IF THE DEMISSING | | | WALLS, FIRE RATED WALLS AND CEILINGS OF THE SERVER ROOM | | | AND ELECTRIC ROOM WERE TO BE COMPLETED UNDER THE BASE | | | BUILDING PERMIT, THE THROUGH PENETRATIONS OF THE | | | VARIOUS TRADES WILL NEED DETAILS INDICATING AS TO WHAT | | | SYSTEMS TO BE USED AND OR UL LISTINGS WHICH WOULD AGAIN | | | FALL INTO THE WORK TO BE COMPLETED BY THE TRADES THAT | | | ARE COVERED UNDER THIS PERMIT. 712.4.1. THROUGH | | | PENETRATIONS, HORIZONTAL AND VERTICAL. | | | | | | 6C) PLEASE NOTE ELECTRICAL COMMENT ABOUT TRANSFORMER | | | ABOVE RATED CEILING IN THE ELECTRIC ROOM 127. 106.1.2 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 7) COMPLIED. | | | | | | 8) RECONFIGURATION OF TENANT SPACE, CLOSET 133 IS | | | MISSING THE DOOR IDENTIFICATION MARKER BUT THE DOOR IS | | | MISSING 18" CLEARENCE ON THE LATCH SIDE OF THE DOOR. | | | 11-4.13.6 MANEUVERING CLEARENCES AT DOORS. MINIMUM | | | MANEUVERING CLEARANCES AT DOORS THAT ARE NOT AUTOMATIC | | | OR POWER-ASSISTED SHALL BE AS SHOWN IN FIG. 25. THE | | | FLOOR OR GROUND AREA WITH IN THE REQUIRED CLEARANCES | | | SHALL BE CLEAR & LEVEL. | | | | | | 9-13) COMPLIED. | | | | | | 14) 2ND REQUEST,ON THE INTERIOR ELEVATION SHEETS | | | QUITE A FEW WALLS INDICATE THE USE OF UPHOLSTERED | | | PANELS, SUBMITTED DOCUMENT FOR THE FOAM IS A TEST THAT | | | PASSES CAL 117 NOT THE TEST REQUIRED UNDER SECTION | | | 803.6.1.1 OR 803.1.2. | | | | | | | | | THE TEST REFERED TO IS NOT CAL 117 BUT NFPA 265. WHEN | | | RESEARCHING CAL 117 TEST CRITERIA THIS IS NOT SO CLEAR | | | SINCE INFORMATION FOUND ON THE WEB FOR THIS TEST IS A | | | DRAFT FORM, BUT THE TEST INDICATES THAT TWO PROPOSALS | | | ONE A B5 SECOND FLAME TEST, AND THE SECOND PROPOSAL A | | | 10 SECOND FLAME TEST BUT THE KW OF FIRE OR HEAT APPLIED | | | IS NOT PROVIDED. IN ONE AREA OF THE REPORT IT SUGESTED | | | THAT OF A BURNIUNG CIGARETTE.THE PAS FAIL CRITERIA | | | WAS ALSO A AREA OF QUESTION SINCE THIS IS A DRAFT FORM | | | DOCUMENT. | | | | | | THE TEST LISTED IN SECTIONS 803.6.1.1 AND 603.6.1.2 | | | REFERENCE NFPA 265 AND THE RESULTS IT TAKES TO PASS | | | THIS TEST BY USING METHOD A OR THE MORE RESTRICTIVE | | | METHOD B. IN EITHER CASE THE FABRIC, FOAM AND | | | "ADHESIVE" ARE TO BE TESTED.BELOW IS THE TEST | | | CRITERIA TO BE MET WHICH IS MORE RESTRICTIVE THAN THE | | | CAL 117 SUBMITTED. | | | | | | NFPA 265:9.1 METHOD A 9.2. | | | METHOD B PROTOCOL SPECIFIED IN 1.4.1 SHALL BE USED. | | | 9.2 PROCEDURE. | | | THE TEST PROCEDURE SHALL BE AS FOLLOWS: | | | (1)ESTABLISH AN INITIAL VOLUMETRIC FLOW RATE OF | | | AT LEAST 0.47 M3/S (1000 STANDARD FT3/MIN) THROUGH THE | | | DUCT, AND INCREASE THE VOLUME FLOW RATE TO 3.4 M3/S | | | (7000 STANDARD FT3/MIN) AS REQUIRED TO KEEP THE OXYGEN | | | CONTENT ABOVE 14 PERCENT AND TO CAPTURE ALL EFFLUENTS | | | FROM THE BURN ROOM. | | | (2)TURN ON ALL SAMPLING AND RECORDING DEVICES, | | | AND ESTABLISH STEADY-STATE BASELINE READINGS FOR AT | | | LEAST 2 MINUTES. | | | (3)IGNITE THE GAS BURNER AND PROCEED AS FOLLOWS: | | | | | | (A)START THE TIMER ONCE BURNER IGNITION HAS BEEN | | | OBSERVED, AND INCREASE GAS FLOW RATE TO PROVIDE A | | | BURNER RATE OF HEAT RELEASE EQUAL TO THE REQUIRED HEAT | | | OUTPUT FOR THE INITIAL PERIOD. THIS RATE SHALL BE 40 KW | | | ? 1 KW FOR 5 MINUTES ? 10 SECONDS. | | | (B)CONTINUE THE EXPOSURE AT THAT SAME LEVEL FOR 5 | | | MINUTES. | | | (C)WITHIN 10 SECONDS AFTER THE 5-MINUTE INITIAL | | | EXPOSURE, INCREASE THE GAS FLOW RATE TO PROVIDE A RATE | | | OF HEAT RELEASE BY THE BURNER EQUAL TO THE FINAL HEAT | | | OUTPUT FOR A 10-MINUTE PERIOD. THIS RATE SHALL BE 150 | | | KW ? 5 KW. | | | (D)CONTINUE THE EXPOSURE AT THAT SAME LEVEL FOR | | | 10 MINUTES ? 10 SECONDS. | | | (4)PROVIDE VISUAL DOCUMENTATION IN ACCORDANCE | | | WITH 7.1.4. | | | (5)PROVIDE A VOICE OR WRITTEN RECORD OF THE FIRE, | | | WHICH WILL PROVIDE THE TIMES OF ALL SIGNIFICANT EVENTS, | | | SUCH AS TIMES OF IGNITION, ESCAPE OF FLAMES THROUGH THE | | | DOORWAY, AND FLASHOVER. | | | (6)SHUT OFF THE IGNITION BURNER 15 MINUTES AFTER | | | START OF THE TEST, AND TERMINATE THE TEST AT THAT TIME | | | UNLESS SAFETY CONSIDERATIONS DICTATE AN EARLIER | | | TERMINATION. | | | (7)DOCUMENT DAMAGE AFTER THE TEST, USING WORDS, | | | PICTURES, AND DRAWINGS. | | | | | | | | | METHOD B: | | | 1.4.1 THE SAMPLE SHALL BE TESTED BY USING A CORNER TEST | | | EXPOSURE WITH THE SPECIMENS MOUNTED ON THREE FULLY | | | LINED WALLS OF THE TEST COMPARTMENT (METHOD B). | | | 1.4.1.1 THESE TEST METHODS SHALL USE A GAS BURNER TO | | | PRODUCE A DIFFUSION FLAME TO EXPOSE THE WALLS IN THE | | | CORNER OF A ROOM 2.4 M3.7 M2.4 M (8 FT12 FT8 | | | FT). | | | 1.4.1.2 THE BURNER SHALL PRODUCE A PRESCRIBED RATE OF | | | HEAT OUTPUT OF 40 KW FOR 5 MINUTES FOLLOWED BY 150 KW | | | FOR 10 MINUTES, FOR A TOTAL EXPOSURE PERIOD OF 15 | | | MINUTES. | | | 1.4.1.3 THE CONTRIBUTION OF THE TEXTILE WALL COVERING | | | TO FIRE GROWTH SHALL BE MEASURED BY CONSTANT MONITORING | | | OF THE INCIDENT HEAT FLUX ON THE CENTER OF THE FLOOR, | | | THE TEMPERATURE OF THE GASES IN THE UPPER PART OF THE | | | ROOM, THE RATE OF HEAT RELEASE, THE SMOKE RELEASE, AND | | | THE TIME TO FLASHOVER. | | | 1.4.1.4 THE TEST SHALL BE CONDUCTED WHILE PROVIDING | | | NATURAL VENTILATION TO THE ROOM, THROUGH A SINGLE | | | DOORWAY OF 0.8 M2.0 M (30 IN.80 IN.). | | | 1.4.1.5 THE COMBUSTION PRODUCTS SHALL BE COLLECTED IN A | | | HOOD FEEDING INTO A CHAMBER THAT IS CONNECTED TO AN | | | EXHAUST DUCT IN WHICH MEASUREMENTS OF THE GAS VELOCITY, | | | TEMPERATURE, AND CONCENTRATIONS OF SELECTED GASES ARE | | | MADE. | | | 1.4.2 FLASHOVER SHALL BE CONSIDERED TO HAVE OCCURRED | | | WHEN ANY TWO OF THE FOLLOWING CONDITIONS HAVE BEEN | | | ATTAINED: | | | (1)THE HEAT RELEASE RATE EXCEEDS 1 MW. | | | (2)THE HEAT FLUX AT FLOOR EXCEEDS 20 KW/M2. | | | (3)THE AVERAGE UPPER LAYER TEMPERATURE EXCEEDS | | | 600?C (1112?F). | | | (4)FLAMES EXIT THE DOORWAY. | | | (5)AUTOIGNITION OF PAPER TARGET ON FLOOR OCCURS. | | | | | | | | | TEXTILE WALL COVERINGS. TEXTILE WALL COVERINGS SHALL | | | HAVE A CLASS A FLAME SPREAD INDEX IN ACCORDANCE WITH | | | ASTM E 84 AND BE PROTECTED BY AUTOMATIC SPRINKLERS | | | INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 OR | | | 903.3.1.2 OR THE COVERING SHALL MEET THE CRITERIA OF | | | SECTION 803.6.1.1 OR 803.6.1.2 WHEN TESTED IN THE | | | MANNER INTENDED FOR USE IN ACCORDANCE WITH NFPA 265 | | | USING THE PRODUCT MOUNTING SYSTEM, INCLUDING ADHESIVE. | | | | | | 15) COMPLIED. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-15 |
Time |
20:06 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2007-08-15 |
Time |
20:06 |
Sent To |
|
|
| Notes |
| 2007-08-15 21:18:02 | GOODRICH LLC CITY PL. TOWER SUITE # 1000 | | | BUILDING PLAN REVIEW | | | PERMIT: 07070352 | | | ADD: 525 OKEECHOBEE BLVD # 1000 | | | CONT: DAVIS GENERAL CONTRACTING CORP | | | TEL: (561) 820-1400 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) BASED ON THE DETERMINATION OF THE BUILDING OFFICIAL, | | | APPLICATION FOR TENANT IMPROVEMENT PRIOR TO C.O. WILL | | | REQUIRE SHOP DRAWING REVIEW BY THE BASE BUILDING DESIGN | | | TEAM, THE DESIGNER OF RECORD. PLEASE HAVE THE BASE | | | BUILDING DESIGNERS OF RECORD REVIEW YOUR PLANS AND IF | | | FOUND SUFFICIENT AFFIX THEIR SHOP DRAWING STAMP ON YOUR | | | DOCUMENTS. | | | NOTE ALSO THAT A TENANT CAN NOT ACHIEVE A CERTIFICATE | | | OF OCCUPANCY BEFORE THE SHELL BUILDING HAS RECEIVED | | | THEIR CERTIFICATE OF COMPLETION. FBC 106.1.2* | | | ADMINISTRATIVE CODE. | | | | | | 3)PLEASE NOTE AT THIS TIME THIS BUILDING HAS NOT | | | RECEIVED A CERTIFICATE OF COMPLETION, AND THE ENERGY | | | CALCULATIONS ARE BASED ON A SHELL BUILDING AND ARE | | | BASED ON 13-101.1.6. UNLESS THE BUILDING IS COMPLETED | | | AS PER ALL ASSUMPTIONS MADE IN THE ORIGINAL CODE | | | COMPLIANCE SUBMITTAL, REVISED CODE SUBMITTALS USING | | | METHOD A, B OR C SHALL BE SUBMITTED WHEN THE COMPLETION | | | OF THE BUILDING (OR PART) OF A BUILDING IS PERMITTED. | | | | | | 4)PLEASE CONTACT LILI URSA AT 822-1239 FOR SUITE | | | NUMBER ASSIGNMENT PLEASE PROVIDE THIS INFORMATION IN | | | THE TITLE BLOCK, SEE FLORIDA ADMINISTRATIVE CODES | | | 61G1-15.004 AND 61G15-23.002. | | | | | | 5) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE | | | OF OCCUPANCY, TO BE LISTED IN THE PLAN: | | | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT | | | IS DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, | | | TABLE 601. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED F) | | | WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE | | | BUILDING PERMIT | | | | | | 6A) SHEET ID-1A WALL TYPE "A" IS INDICATED AS AN | | | EXISTING CMU DEMISING WALL, PLEASE COORDINATE WITH THE | | | BASE BUILDING DESIGNER. ADDITIONAL INFORMATION | | | REQUIRED, FBC ADMINISTRATIVE CODE 106.1.2*. THE SHELL | | | BUILDING PLAN SHEET A1.06 & A2.06 BOTH INDICATE THIS | | | WALL TO BE A DRYWALL AND METAL STUD WALL. | | | | | | 6B) SHEET ID-1A ALSO INDICATES THE TENANT SEPERATION | | | WALLS TO BE EXISTING CMU DEMISSING WALL.THE BASE | | | SHELL BUILDING PLAN DOESN'T INDICATE ANY SUCH WALL. | | | 708.1(5) REQUIRES FIRE PARTITIONS BETWEEN TENANTS. | | | 708.3 FIRE RESISTANCE RATING WILL REQUIRE A 1-HOUR FIRE | | | RATING. | | | FLORIDA STATE STATUTE 481.2131 INTERIOR DESIGNER CAN | | | NOT DESIGN PLANS OR PORTIONS OF THAT EFFECT FIRE-RATED | | | SEPERATIONS BETWEEN INTERIOR SPACES, THE FIRM IS | | | WORKING OUT OF THE SCOPE OF THEIR LOCENSE. SEE | | | ATTACHMENT 481.2131. | | | | | | 7) SHEET ID-1A DOOR# 002IS INDICATED TO BE A SINGLE | | | 2'-8" DOOR CUT IN HALF, CLOSETS THAT AREDEEPER THAN | | | 2'-0" WILL REQUIRE A MINIMUM CLEAR WIDE OF 32" WHEN THE | | | DOOR OR DOORS ARE OPEN 90 DEGREES TO THE OPENING. SEE | | | 11-4.13.5 | | | 11-4.13.5 CLEAR WIDTH. | | | DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 | | | INCHES (813 MM) WITH THE DOOR OPEN 90 DEGREES, MEASURED | | | BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE STOP [SEE | | | FIGURE 24 (A), FIGURE 24 (B), FIGURE 24 (C), AND FIGURE | | | 24 (D)]. OPENINGS MORE THAN 24 INCHES (610 MM) IN DEPTH | | | SHALL COMPLY WITH SECTIONS 11-4.2.1 AND 11-4.3.3 [SEE | | | FIGURE 24 (E)]. | | | EXCEPTION: DOORS NOT REQUIRING FULL USER PASSAGE, SUCH | | | AS SHALLOW CLOSETS, MAY HAVE THE CLEAR OPENING REDUCED | | | TO 20"MINIMUM. | | | | | | 8) SHEET ID-1A DOORS 023 AND 024 ARE BOTH CLOSET DOORS | | | THAT OPEN TO A CLOSET DEEPER THAN 24" REQUIRING A CLEAR | | | 32" OPENING. | | | SEE 11-4.13.5 CLEAR WIDTH. | | | | | | 9) DOORS 16-19 ARE INDICATED AS 28" DOORS THAT LEAD TO | | | THE INDIVIDUAL WATER CLOSET STALLS.PLEASE SEE 11-4.13.5 | | | AND 11-4.17.5 | | | DOORS. TOLIET STALL DOORS INCLUDING DOOR HARDWARE, | | | SHALL COMPLY WITH SECTION 11-4.13.. DOORS SHALL BE SELF | | | CLOSING. | | | 11-4.17.3 EXCEPTION: NEW CONSTRUCTION. | | | (1)THE STANDARD ACCESSIBLE RESTROOM STALL SHALL | | | CONTAIN AN ACCESSIBLE LAVATORY WITHIN IT, THE SIZE OF | | | SUCH LAVATORY TO BE NOT LESS THAN 19 INCHES WIDE BY 17 | | | INCHES (483 MM BY 432 MM) DEEP, NOMINAL SIZE, AND WALL | | | MOUNTED. THE LAVATORY SHALL BE MOUNTED SO AS NOT TO | | | OVERLAP THE CLEAR FLOOR SPACE AREAS REQUIRED BY SECTION | | | 11-4.17 [SEE FIGURE 30 (A) AND FIGURE 30 (E)] AND TO | | | COMPLY WITH SECTION 11-4.19 OF THE CODE. SUCH | | | LAVATORIES SHALL BE COUNTED AS PART OF THE REQUIRED | | | FIXTURE COUNT FOR THE BUILDING. | | | (2)THE ACCESSIBLE WATER CLOSET SHALL BE LOCATED IN | | | THE CORNER, DIAGONAL TO THE DOOR. | | | | | | 10) IN BOTH THE WOMEN'S AND MEN'S RESTROOMS THERE ARE | | | NO HANDICAPPED STALLS. 11-4.1.3(11)TOILET FACILITIES. | | | IF TOILET ROOMS ARE PROVIDED, THEN EACH PUBLIC AND | | | COMMON USE TOILET ROOM SHALL COMPLY WITH SECTION | | | 11-4.22 . | | | EXCEPTION: NEW CONSTRUCTION. | | | (1)THE STANDARD ACCESSIBLE RESTROOM STALL SHALL | | | CONTAIN AN ACCESSIBLE LAVATORY WITHIN IT, THE SIZE OF | | | SUCH LAVATORY TO BE NOT LESS THAN 19 INCHES WIDE BY 17 | | | INCHES (483 MM BY 432 MM) DEEP, NOMINAL SIZE, AND WALL | | | MOUNTED. THE LAVATORY SHALL BE MOUNTED SO AS NOT TO | | | OVERLAP THE CLEAR FLOOR SPACE AREAS REQUIRED BY SECTION | | | 11-4.17 [SEE FIGURE 30 (A) AND FIGURE 30 (E)] AND TO | | | COMPLY WITH SECTION 11-4.19 OF THE CODE. SUCH | | | LAVATORIES SHALL BE COUNTED AS PART OF THE REQUIRED | | | FIXTURE COUNT FOR THE BUILDING. | | | (2)THE ACCESSIBLE WATER CLOSET SHALL BE LOCATED IN | | | THE CORNER, DIAGONAL TO THE DOOR. | | | | | | 11) SHEET ID-14 DETAIL A1 BREAK ROOM# 112 SINKS: | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE MOUNTED WITH | | | THE COUNTER NO HIGHER THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" | | | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS. | | | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT | | | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR | | | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE | | | SINK. | | | | | | 12)SHEET ID-14 DETAIL A11 & A15 BOTH ARE OF RESTROOM | | | VANITIES AND LAVATORIES.11-4.19.2 HEIGHT AND | | | CLEARANCES. | | | LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER | | | SURFACE NO HIGHER THAN 34 INCHES (865 MM) ABOVE THE | | | FINISH FLOOR. PROVIDE A CLEARANCE OF AT LEAST 29 INCHES | | | (735 MM) ABOVE THE FINISH FLOOR TO THE BOTTOM OF THE | | | APRON. KNEE AND TOE CLEARANCE SHALL COMPLY WITH FIGURE | | | 31 . | | | | | | 11-4.19.3 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES (760 MM BY | | | 1219 MM) COMPLYING WITH SECTION 11-4.2.4 SHALL BE | | | PROVIDED IN FRONT OF A LAVATORY TO ALLOW FORWARD | | | APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR | | | OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM | | | OF 19 INCHES (485 MM) UNDERNEATH THE LAVATORY (SEE | | | FIGURE 32 ). | | | | | | 11-4.19.4 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE | | | INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST | | | CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES | | | UNDER LAVATORIES. | | | | | | 13)TABLE 803.3 MINIMUM INTERIOR FINISH | | | CLASSIFICATION; PROVIDE INFORMATION BASED ON INTERIOR | | | FINISH REQUIREMENTS BASED ON OCCUPANCY. | | | | | | 14) ON THE INTERIOR ELEVATION SHEETS QUITE A FEW WALLS | | | INDICATE THE USE OF UPHOLSTERED PANELS, PLEASE PROVIDE | | | ADDITIONAL INFORMATION 106.1.2.HOW WILL THE FABRIC BE | | | MOUNTED? 803.6.1 TEXTILE WALL COVERINGS. | | | TEXTILE WALL COVERINGS SHALL HAVE A CLASS A FLAME | | | SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE | | | PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN | | | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 OR THE | | | COVERING SHALL MEET THE CRITERIA OF SECTION 803.6.1.1 | | | OR 803.6.1.2 WHEN TESTED IN THE MANNER INTENDED FOR USE | | | IN ACCORDANCE WITH NFPA 265 USING THE PRODUCT MOUNTING | | | SYSTEM, INCLUDING ADHESIVE. | | | | | | 15) THE MILLWORK LEGEND INDICATES CATALOG NUMBERS FOR | | | TRIM BUT DOESN'T IDENTIFY AS TO WHAT TYPE OF MATERIALS | | | THE TRIM WILL BE MADE OF? 106.1.2* ADDITIONAL | | | INFORMATION REQUIRED.805.5 TRIM . | | | MATERIAL USED AS INTERIOR TRIM SHALL HAVE A MINIMUM | | | CLASS C FLAME SPREAD INDEX AND SMOKE-DEVELOPED INDEX. | | | COMBUSTIBLE TRIM , EXCLUDING HANDRAILS AND GUARDRAILS, | | | SHALL NOT EXCEED 10 PERCENT OF THE AGGREGATE WALL OR | | | CEILING AREA IN WHICH IT IS LOCATED. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-10 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-10 |
Time |
10:56 |
Sent To |
PC |
|
| Notes |
| 2008-09-10 10:56:54 | REV FOR FINAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-28 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-28 |
Time |
11:46 |
Sent To |
PC |
|
| Notes |
| 2008-08-28 11:46:27 | | | | ** DENIEDREVISION ** | | | | | | | | | | | | 1) NOTE: PLEASE COORDINATE ALL CIRCUITING ON PLANS WITH | | | PANEL SCHEDULES AND ALSO WITH THE LIGHTING CONTACTOR | | | PANELS. | | | THIS WAS THE SAME AS IN REVIEW NOTES DATED ON 7/15/08 | | | YET NO CHANGES HAVE BEEN MADE. | | | FOR EXAMPLE: | | | PLEASE SEE LIGHTING AND POWER PLANS WHICH BOTH INDICATE | | | CIRCUITS? 10LA-13 AND 10LA-5 TO BE ON LIGHTING | | | CONTACTORS YET NEITHER LIGHTING CONTACTOR ON SHEET E6.1 | | | CONTAINS THESE. THIS IS NOTING ONLY TWO, THERE ARE | | | OTHERS. | | | 13-415.1.ABC.1.1, .1.2, .1.3. | | | FBC 106.1.1 | | | | | | 2) NOTE: PLEASE SEE KEY NOTES ON SHEET E3.1 WHICH DOES | | | NOT CONTAIN A KEYNOTE #6 AS NOTED ON PLANS. (MISPRINT) | | | FBC 106.1.1 FOR CLARITY AND COORDINATION. | | | | | | 3) NOTE: PLEASE SEE SHEET E3.1 AS THIS INDICATES A | | | *FPL* METER. IT HAS COME TO THIS REVIEWER?S ATTENTION | | | THAT THERE IS NO FPL METER IN FACT IT IS NOT A TENANT | | | CHECK METER EITHER. PLEASE VERIFY WHAT THIS DEVICE IS | | | AND REVISE PLANS ACCORDINGLY. | | | FBC 106.1.1, 106.3.5.1.2 | | | NEC | | | | | | 4) NOTE: PLEASE REVISE ALL LIGHTING PERFORMANCE | | | CALCULATIONS. THERE HAVE BEEN REVISIONS TO LIGHTS AND | | | PLANS YET THE WATTAGE EVEN THOUGH LABELED AS REVISED | | | DOES NOT COORDINATE. | | | ONE EXAMPLE OF THIS IS THE STORAGE ROOM # 128 WHICH | | | INDICATES A TOTAL OF 68WATTS YET THIS IS NOT POSSIBLE | | | BASED ON THE WATTAGE OF EACH FIXTURE ON N | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2008-07-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-15 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-15 |
Time |
08:29 |
Sent To |
PC |
|
| Notes |
| 2008-07-15 08:30:07 | ** DENIEDREVISIONS ** | | | | | | | | | 1) NOTE:THE SHEET E 6.1 SUBMITTED NOW DOES NOT | | | COORDINATE WITH THE PREVIOUS SUBMITTED POWER PLANS AND | | | LIGHTING PLANS FOR CIRCUITING. PLEASE SUBMIT REVISED | | | LIGHTING AND POWER PLANS WITH REVISED CIRCUITING ETC. | | | 408.4, 310.16, 240.4, 220, ETC | | | FBC 106.1.2, 106.1.1 | | | | | | 2) NOTE: THE LIGHTING POWER DENSITIES WERE REVISED | | | HOWEVER NO REVISED LIGHTING PLANS WERE SUBMITTED. | | | PLEASE SUBMIT. FBC 13-415.2, 13-415.2.ABC.1.1, .1.2 | | | FBC 106.5, 106.1.1 | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-15 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-15 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2008-01-15 13:04:58 | FA AND FS SHEETS STILL NEED FIRE REVIEW STAMPS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-22 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-22 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2007-12-22 12:45:02 | ** DENIED3RDREVIEW ** | | | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS TWO REVIEWS | | | WITH RESPECT TO LIGHTING PERFORMANCE CALCULATIONS AND | | | LIGHTING CONTROLS ARE STILL IN NEED OF ADDRESSING. | | | | | | 1) NOTE: PLEASE SEE THE LIGHTING PERFORMANCE | | | CALCULATIONS WHICH ARE BEING SUBMITTED FOR REVIEW ARE | | | NOW COMPLETE HOWEVER COORDINATION OF PLANS, FIXTURES, | | | AND CALCULATIONS ARE NEEDED. IN THE MEETING HELD ON | | | DECEMBER 18TH, 2007 THE PREVIOUS COMMENT WAS GONE OVER | | | TO MAKE SURE ALL LIGHTING WHICH IS SHOWN ON PLANS IS IN | | | THE CALCULATIONS NOW SHOWN AND SUBMITTED ON E6.1. THERE | | | WAS NO COMPLETE REVIEW OF CALCULATIONS THE COMMENT WAS | | | MADE TO PLEASE BE SURE ALL COORDINATION WAS ADDRESSED. | | | FIXTURE LEGEND DOES NOT COMPLETE INFORMATION FOR WALL | | | SCONCES ONLY GIVES THE 40W DESIGNATION WHICH IS OK. ANY | | | CHANGES OF MINIMUM FIXTURES MAY BE DONE BEFORE | | | INSTALLATION. | | | PLEASE SEE BELOW AS THERE ARE SOME EXAMPLES WHICH ARE | | | BEING GIVEN WHICH NOTES SOME OF THE LOCATIONS ON PLANS | | | WHICH ARE STILL IN QUESTION. | | | THESE ARE FOR EXAMPLE: | | | | | | PLEASE SEE MISSING ROOM 133 FROM CALCULATIONS. | | | | | | PLEASE SEE MISSING ROOM 128 FROM CALCULATIONS. | | | | | | PLEASE SEE ROOM 108 AS 6-32W FIXTURES AND 1-J-FIXTURE | | | WHICH IS 200W IS SHOWN ON PLANS. THIS TOTALS 392W | | | HOWEVER THE CALCULATION SHOWS DESIGN AS 328W. | | | | | | PLEASE SEE ROOM 105 AS PLANS SHOWS 5-32W FIXTURES WHICH | | | TOTALS 160W YET CALCULATIONS SHOWS DESIGN AS128W. | | | | | | PLEASE SEE ROOM 101 (LOBBY) WHICH INDICATES 7-32W, 2-35 | | | AND 2-40W (WALL SCONCES) WHICH IS 374W YET CALCULATIONS | | | SHOWS DESIGN AS 310W. | | | | | | PLEASE SEE ROOM 112 AS PLANS SHOW 5-32W, 3-32W (UC LTS) | | | WHICH IS A TOTAL OF 256W, YET THE CALCULATIONS SHOWS | | | DESIGN AS 192W. | | | | | | PLEASE SEE THE CORRIDORS AS THE TOTAL NUMBER OF GENERAL | | | LIGHTING AND DECORATIVE LIGHTING FIXTURES COMES TO A | | | TOTAL OF 1462W, YET BASED ON THE TOTAL OF CORRIDOR | | | DESIGN WATTAGE SHOWN ON TABLE, THE TOTAL IS 1145W. | | | | | | ** PLEASE SEE SOME OTHER ROOMS SUCH AS 107 SHOWS 397W | | | BASED ON PLANS AND FIXTURES SHOWN AND TABLE DESIGN IS | | | 497W? | | | | | | THE ABOVE IS SOME EXAMPLES; PLEASE MAKE SURE ALL | | | LIGHTING ON PLANS CORRELATES WITH THE LIGHTING | | | CALCULATIONS. | | | 13-415.2, 13-415.2.B.1, TABLE 13-415.2.B | | | | | | 2) NOTE: PLEASE SEE AS PREVIOUSLY MENTIONED ON BOTH | | | PREVIOUS REVIEWS, PLEASE COMPLETE AND COORDINATE ALL | | | LIGHTING CIRCUITS FOR LIGHTING CONTACTORS AND CONTROLS | | | PER FBC CHAPTER 13, 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE PREVIOUS NOTES GAVE A COUPLE OF EXAMPLES AND | | | SPECIFICALLY STATED THESE WERE NOT ALL. IN MEETING HELD | | | DECEMBER 18TH, 2007 A COMMENT WAS MADE TO PLEASE BE | | | SURE ALL CIRCUITING FOR LIGHTING ETC WAS COORDINATED ON | | | PLANS, PANELS, CONTROLS ETC. | | | PLEASE SEE BELOW FOR EXAMPLES: | | | | | | ROOM 120, 130 AS BOTH OF THESE ROOMS CONTAINS A | | | CIRCULAR NOTE #1 WHICH STATES TO CONNECT TO THE | | | LIGHTING CLOCK OUTLETS TO THE SAME WALL SCONCE LIGHTING | | | CIRCUIT IN THAT SPECIFIC ROOM. PLEASE SEE THESE ARE | | | NOTED AS CIRCUIT 10LA-13 ON POWER PLANS YET THE | | | LIGHTING PLANS WHICH SHOWS THE LIGHTING CIRCUIT | | | INDICATES 10LA-15. | | | | | | ROOM/LOBBY 101 WHICH INDICATES LIGHTING OUTLETS FOR | | | CIRCUIT 10LB-16, YET THIS CIRCUIT IS NOT ON EITHER | | | LIGHTING CONTACTOR LCA OR LCB. PLEASE SEE THE SWITCH IS | | | STILL ALSO SHOWN AS A STANDARD SINGLE POLE SWITCH FOR | | | THESE LIGHTING OUTLETS. | | | PLEASE SEE PANEL SCHEDULE AS CIRCUIT IS NOTED FOR | | | GENERAL PURPOSE RECEPTACLES | | | | | | ROOM 109 AND 111 WHICH CONTAIN CIRCUITS FOR ACCENT | | | LIGHTING TIED TOGETHER. PLEASE SEE THE ACCENT LIGHTING | | | OUTLETS ON POWER PLANS FOR THESE ROOMS ARE SHOWN AS | | | CIRCUIT 10LA7, HOWEVER LIGHTING PLANS SHOW 10LA- AND | | | 10LA- 11 TIED TOGETHER. | | | PLEASE ALSO SEE EVEN AS THE PLANS CONTAINS NOTES WHICH | | | MENTIONS ALL ACCENT LIGHTING TO CONTACTORS, NEITHER | | | CONTACTOR SCHEDULE LCA OR LCB CONTAIN EITHER10LA-7 OR | | | 10LA-11? | | | PLEASE SEE EVEN AS THESE SWITCHED LIGHTING OUTLETS | | | CONTAIN A NOTE #1 ON ROOM 117 WHICH STATES TO CONNECT | | | TO WALL SCONCE CIRCUIT IN SAME ROOM, THE WALL SCONCES | | | IN THIS SAME ROOM 117 DOES NOT CONTAIN ANY CIRCUIT(S). | | | | | | ROOM/CORRIDOR 123 CONTAINS A SWITCH WITH A NOTE WHICH | | | STATES TO HALLWAY WALL SCONCES, YET THE PLANS DOE NOT | | | SHOW ANY HALLWAY WALL SCONCES? | | | | | | *** AS MENTIONED ON PREVIOUS REVIEWS AND MEETING PLEASE | | | BE SURE ALL ITEMS ON PLANS CORRELATE WITH ALL LIGHTING | | | CONTROLS REQUIRED IN SECTIONS NOTED ABOVE. SOME OF THE | | | EXAMPLES AS NOTED ABOVE MAY NOT BE ALL AND ONLY SOME | | | EXAMPLES WERE GIVEN. | | | | | | | | | 3) NOTE: PLEASE SEE PREVIOUS REVIEW GAVE NOTICE TO FS | | | 553.80(2)(B) WITH RESPECT TO REPEAT COMMENTS FOR | | | MINIMUM CODE COMPLIANCE. | | | PLEASE SEE THAT A FEE OF $7500.00 HAS BEEN ASSESSED AS | | | REQUIRED BY THE FLORIDA STATUTES. PLEASE ALSO SEE AS | | | REQUIRED UNDER THE FLORIDA STATUTES FEE MUST BE PAID | | | BEFORE NEXT RE-SUBMISSION OF PLANS. | | | THIS IS NOT THE RESPONSIBILITY OF THE CONTRACTOR OR | | | OWNER. | | | ** PLEASE KNOW ONE SET OF ELECTRICAL PLANS ARE BEING | | | RETAINED BY THIS OFFICE. | | | | | | *** AS STATED ON PREVIOUS REVIEWS, IF THERE ARE ANY | | | QUESTIONS, COMMENTS OR IF ANY PARTS OF THE NOTES WHICH | | | ARE TYPED ARE NOT CLEAR IN ANY WAY, PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE FOR CLARIFICATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-28 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-28 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2007-11-28 11:33:41 | ** DENIED2ND REVIEW ** | | | | | | ** PLEASE KNOW THERE ARE STILL SOME COMMENTS FROM | | | PREVIOUS REVIEW WHICH ARE IN NEED OF ADDRESSING ALONG | | | WITH NEW COMMENTS DUE TO ITEMS NOW REVISED ON PLANS | | | WHICH WERE NOT ON ORIGINAL PLANS. | | | | | | 1) NOTE: PLEASE SEE THE PERMIT APPLICATION PACKAGE WAS | | | SUBMITTED BACK WITH RESPONSES FROM THE INTERIOR DESIGN | | | TEAM WHICH MENTIONS TO SEE RESPONSES TO THE MEP NOTES | | | FROM OTHER DESIGN PROFESSIONALS; HOWEVER NO RESPONSE | | | LETTERS FROM ANY OTHER TRADE DESIGNERS WERE LOCATED | | | WITH PACKAGE BROUGHT BACK. | | | (PACKAGE CONTAINED: | | | 1) LETTER/RESPONSE FROM STH FOR BASE BUILDING REVIEW. | | | | | | 2) 3-BOOKETS FOR RESPONSES FROM LISA ERDMANN AND | | | ASSOCIATES. | | | | | | 3) ORIGINAL PERMIT APPLICATION WITH NOTES FROM TRADES. | | | | | | ** PLEASE KNOW RESPONSES FROM MEP DESIGNERS ARE NOT | | | REQUIRED HOWEVER DO HELP TO EXPEDITE THE REVIEW PROCESS | | | ON HOW COMMENTS WERE ADDRESSED OR RESPONSE ON | | | COMMENTS. | | | | | | | | | 2) NOTE: PLEASE SEE THAT THE FOLLOWING CODES SHALL BE | | | STATED ON PLANS. PLEASE SEE THIS COMMENT IS FOR THE ID | | | COVER SHEETS AS IT REFLECTS A 2003 NFPA-70. | | | PLEASE KNOW THIS SHOULD BE 2005. | | | IF THIS SHEET DOES NOT NEED TO BE REVISED FOR OTHER | | | TRADES OR FOR OTHER COMMENTS, THERE WILL BE NO NEED TO | | | RE-PRINT SHEET ONLY FOR THIS. IT COULD BE REDLINED. | | | | | | 2) NOTE: PLEASE SEE ELECTRICAL PLANS INDICATES THE | | | TRANSFORMER AS CEILING MOUNTED HOWEVER THE ID PLANS | | | SPECIFICALLY CALL FOR A 1HR RATED CEILING TO BE | | | INSTALLED IN THIS SAME ROOM. | | | THIS WAS GONE OVER IN THE MEETING PREVIOUSLY HELD | | | BEFORE PLANS WERE RESUBMITTED THAT THE CODE | | | SPECIFICALLY 450.13 A AND B DOES NOT PERMIT THIS SIZE | | | OF TRANSFORMER ABOVE CEILING. THE COMMENT IN THE | | | MEETING WAS THAT THERE WOULD BE NO CEILING INSTALLED IN | | | THE ELECTRICAL ROOM 127 AND THE 1HR RATED WALLS WERE | | | GOING TO GO UP TO THE DECK. | | | PLEASE ADJUST. | | | | | | 3) NOTE: PLEASE SEE POSSIBLE COMMENTS FROM MECHANICAL | | | REVIEW FOR RATED CEILING IN SERVER ROOM 104. ** THIS IS | | | ONLY NOTED FOR INFORMATIONAL PURPOSE. | | | | | | 4) NOTE: PLEASE SEE PREVIOUS COMMENTS WITH RESPECT TO | | | COMPLETED SYSTEM FOR LIGHTING CONTROLS PER FBC CHAPTER | | | 13, 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE THERE ARE CIRCUITS ON PLANS WHICH ARE NOTED | | | TO LIGHTING CONTACTOR EITHER LCA OR LCB, HOWEVER | | | NEITHER LIGHTING CONTACTOR CONTAINS THESE CIRCUITS. | | | PLEASE SEE FOR EXAMPLE ONE FROM EACH: 10LA-27 AND | | | 10HA-1 | | | PLEASE ALSO SEE 13-415.1.ABC.1.3 FOR ACCENT/TASK | | | LIGHTING. | | | PLEASE COORDINATE AND ADJUST. | | | | | | 5) NOTE: PLEASE COMPLETE LIGHTING PERFORMANCE | | | CALCULATIONS WHICH CONFORM TO THE FBC. PLEASE SEE THE | | | LIGHTING POWER DENSITIES SUBMITTED ON E6.1REFLECT | | | 13-415.2.B.1 WHICH IS FOR SPACE BY SPACE HOWEVER NO | | | SPACE BY SPACE CALCULATIONS WERE SUBMITTED. THE FIGURE | | | SUBMITTED SHOWS ALL AS *OFFICE* ONLY AT 1.1 SQ FT. | | | PLEASE KNOW THE LIGHTING ON PLANS AND FIXTURES SHOWN ON | | | FIXTURE LEGEND ON E0.1 ARE NOT COMPLETE AT THIS TIME. | | | PLEASE IDENTIFY ALL FIXTURES ON FIXTURE LEGEND. FOR | | | EXAMPLE: FIXTURE *J* ON PLANS, NOT ON FIXTURE LEGEND. | | | FOR EXAMPLE: PLEASE SEE THE FIXTURE COUNT SHALL INCLUDE | | | ALL FIXTURES, WATTAGES FOR THE MAXIMUM LPD AS ALLOWED. | | | PLEASE KNOW AS THE FIXTURE LEGEND WILL NEED TO BE | | | ADJUSTED AND SPACE BY SPACE WAS NOT SUBMITTED, A | | | COMPLETE REVIEW OF ALL FIXTURES COULD NOT BE DONE AT | | | THIS TIME. | | | PLEASE BE SURE TO COORDINATE ALL. | | | | | | 6) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT CODE COMPLIANT COMMENTS. THIS IS ONLY A NOTICE | | | GIVEN AT THIS TIME. | | | PLEASE KNOW ONE COPY OF EACH ELECTRICAL HAS BEEN | | | RETAINED BY THIS OFFICE. | | | | | | *** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-06 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-06 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2007-08-06 12:45:17 | | | | | | | ** UNSAT ** | | | | | | | | | 1) NOTE:PLEASE SEE ONCE THE ADDRESSING REVIEWER HAS | | | ASSIGNED A SUITE/UNIT NUMBER, PLEASE BE SURE TO PLACE | | | DESIGNATION ON TITLE BLOCKS. | | | FAC 61G1-16.004, 61G15-23.002 | | | | | | 2) NOTE: PLEASE SEE THE ID PLANS ARE REQUIRED TO BE | | | DATED WHEN SIGNING AND SEALING DOCUMENTS. | | | PLEASE SEE FS 481.221. | | | | | | 3) NOTE: PLEASE KNOW THAT ALL PLANS SHALL BE SIGNED, | | | WITH SIGNATURES AS ON FILE AND RECORD WITH THE CITY OF | | | WEST PALM BEACH AND THIS JURISDICTION. | | | FS 481.221/471.025 | | | | | | 4) NOTE: PLEASE SEE COMMENTS WHICH WERE MADE BY THE | | | MECHANICAL REVIEWER ALSO WITH RESPECT TO THE BASE | | | BUILDING DESIGN TEAM BEING REQUIRED TO REVIEW THE PLANS | | | AS THIS BUILDING DOES NOT CONTAIN A CO AND ALL WORK | | | BEING DONE ON A BUILDING WHICH IS UNDER THE | | | RESPONSIBILITY OF ANOTHER DESIGN TEAM MUST BE | | | REVIEWED. | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE BE SURE TO STAMP AS REVIEWED. PLEASE BE | | | KNOW ANY ASSUMPTIONS MADE TO THE BASE BUILDING FOR LOAD | | | CALCULATIONS AND ENERGY CALCULATIONS WILL BE REQUIRED | | | TO BE REVISED ON BASE BUILDING AND INFORMATION SHOULD | | | BE MAD AVAILABLE TO THE BASE BUILDING DESIGN TEAM. | | | FBC 106.1.2, 106.3.5.1.2 | | | NEC 220/408/215 ETC | | | FBC CHAPTER 13 AS NOTED ON MECHANICAL REVIEW. | | | | | | 6) NOTE: PLEASE VERIFY THE CORRIDOR BEING UNDER THE | | | SCOPE OF WORK FOR THIS PERMIT OR NOT. PLEASE ALSO | | | VERIFY WITH THE BASE BUILDING DESIGN TEAM AND OWNER FOR | | | POSSIBLE OWNER REQUIRED ELECTRICAL ROOM/AREA. PLEASE | | | SEE THAT THE TENANT/OCCUPANT DOES NOT CONTAIN ACCESS TO | | | OVER CURRENT PROTECTION DEVICES AS REQUIRED. PLEASE SEE | | | THIS WOULD AFFECT THE LOCATIONS AS THE BASE BUILDING | | | HAD CONDITIONS DUE TO CONSTRUCTION BOARD OF APPEALS | | | APPLICATION AND ITEMS GRANTED. | | | PLEASE CORRELATE. | | | FBC 106.3.5.1.2, 106.1.2 FOR ADDITIONAL INFORMATION AND | | | COORDINATION. | | | 240.24D. | | | | | | 7) NOTE: PLEASE BE SURE TO CORRELATE ALL ROOM AND AREA | | | DESIGNATIONS ON PLANS. PLEASE SEE DESIGNATIONS AS | | | PROVIDED ON THE ID PLANS ARE NOT THE SAME ON MEP. | | | PLEASE SEE THE ELECTRICAL PLANS CONTAIN THE SAME | | | NUMERICAL DESIGNATION USED IN MORE THAN ONE LOCATION. | | | PLEASE SEE FOR EXAMPLE: ROOM/AREA 103. | | | PLEASE ALSO SEE THE STORAGE ROOM WHICH IS BEING NOTED | | | ON ALL PLANS WHEN IN FACTTHIS IS A SERVER. AND | | | POSSIBLE IT ROOM. | | | FBC 106.1.2 | | | | | | 8) NOTE: PLEASE SEE THE ROOM NOTED AS STORAGE IS SHOWN | | | WITH MULTIPLE CIRCUITS FOR WHAT APPEARS WILL BE AN IT | | | ROOM. | | | PLEASE PROVIDE MORE INFORMATION ON THIS ROOM AND ALL | | | EQUIPMENT INTENDED TO BE INSTALLED. | | | THIS ROOM IS BEING FED WITH A SEPARATE AC SYSTEM. | | | PLEASE SEE 645.10,645.4, 645.5 ETC. | | | | | | 9) NOTE: PLEASE SEE FBC CHAPTER 13 FOR ENERGY CODE | | | COMPLIANCE NEEDS TO BE MET. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | PLEASE SEE MISSING CONTROLS FOR SEPARATE SPACES IN MANY | | | ROOMS. | | | PLEASE SEE THAT NO ENERGY CALCULATIONS/PERFORMANCE | | | CALCULATIONS WERE SUBMITTED FOR REVIEW. 13-415.1.A, | | | 13-415.B, 13-415.1.C, 13-415.2. | | | PLEASE CORRELATE FIXTURE LEGEND FOR ALL FIXTURES ON | | | PLANS WITH CALCULATIONS FOR TYPES, WATTAGE, METHOD OF | | | CONTROL ETC. | | | PLEASE PROVIDE SCHEDULING FOR PROPOSED SYSTEM. PLEASE | | | KNOW A BASE TIME SHOULD BE SHOWN. | | | PLEASE INDICATE LOCATIONS AS REQUIRED FOR ALL OVER RIDE | | | DEVICES SO THE OCCUPANT CAN VISUALLY SEE THE LIGHTING | | | WHICH IS BEING OVER RIDDEN. | | | PLEASE PROVIDE ALL MAXIMUM TIMES ON OVER RIDES AND OVER | | | RIDE DEVICES. | | | PLEASE SUBMIT THE MANUFACTURES/SPEC CUT SHEETS ON THE | | | PROPOSED SYSTEM. PLEASE BE SURE ALL DEVICES/SYSTEM | | | CONTAINS A LISTING FROM A NATIONALLY RECOGNIZED TESTING | | | LABORATORY. (NRTL) | | | 110.3, 90.7. | | | PLEASE BE SURE ALL DOCUMENTS ARE SIGNED, DATED AND | | | SEALED AS REQUIRED PER 13-103.1.1.1 AND OWNER/AGENT IS | | | SIGNED. | | | | | | 10) NOTE: PLEASE SEE THE FIXTURE LEGEND AS PROVIDED ON | | | THE ID PLANS NEEDS COORDINATION WITH THE LEGEND ON THE | | | ELECTRICAL PLANS. | | | FBC 106.1.2 | | | | | | 11) NOTE: PLEASE SEE THE PANEL 10HA SHOWS ON THE RISER | | | AS CONTAINING SOME SORT OF FEED COMING FROM THIS PANEL | | | TO PANEL 10LA, YET THIS DESIGNATION DOES NOT CORRELATE | | | WITH EITHER PANEL OR OTHER INFORMATION. | | | PLEASE SEE THE RISER WHICH SHOWS 10TA-1L? | | | FBC 106.1.2 FOR COORDINATION. | | | | | | | | | 12) NOTE: PLEASE SEE THE TRANSFORMER SCHEDULE INDICATE | | | THE FEEDERS ON THE SECONDARY SIDE OF THE TRANSFORMER AS | | | 4/0 WHICH ARE NOT SUFFICIENT. PLEASE SEE 310.16, 240.4, | | | 240.21 AS THE TAPPED CONDUCTORS ARE REQUIRED TO | | | TERMINATE IN OVER CURRENT PROTECTION WHICH LIMITS THE | | | LOAD ON THE TAPPED CONDUCTOR. | | | | | | 13) NOTE: PLEASE SEE THE OVER CURRENT PROTECTION ON THE | | | PANEL 10LA IS SHOWN AS 250AMPS WHICH IS TOO LARGE FOR | | | THE CONDUCTORS AS NOTED ABOVE IN NOTE #13, HOWEVER THE | | | PANEL MENTIONS THIS CONTAINS FEED-THRU LUGS TO FEED | | | PANEL 10LB, YET PANEL 10LB IS A 225AMP RATED PANEL. | | | THIS DOES NOT MEET THE NEC AS THE RATING OF THE PANEL | | | MUST MEET THE MINIMUM RATING FOR THE OCP WHICH IS | | | 250AMPS AS SHOWN ON PANEL 10LA MAIN. | | | 240.4, 310.16, 408.36, 240.30, 240.20 ETC. | | | | | | ** PLEASE KNOW AS THERE ARE SEVERAL ITEMS NOT YET | | | SUBMITTED FOR REVIEW, THERE MAY VERY WELL BE NEW | | | COMMENTS ON THE FOLLOWING REVIEW WHICH CAN NOT BE MADE | | | AT THIS TIME. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-02-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-04 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-04 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2008-02-04 16:37:13 | *****APPROVED***** | | | | | | | | | PLAN SHEETS 1D-3B, ID-6, ID-6B, E2.1, FA0.1, FA2.1, | | | FS0.1, AND FS2.1 WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-03 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-03 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2007-12-03 13:17:15 | *****PROVISO***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED, HOWEVER, THE APPROPIATE PLAN SHEETS ARE | | | TO BE FIRE-STAMPED WHEN ALL OTHER REVIEWERS HAVE BEEN | | | SATISFIED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-14 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-14 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2007-09-14 11:11:44 | *****DENIED***** | | | | | | (UNLESS OTHERWISE NOTED, THIS TENANT SPACE IMPROVEMENT | | | SHALL BE CLASSIFIED AS A NEW BUSINESS OCCUPANCY) | | | | | | | | | 01.THE NUMERICAL ADDRESS OF THE PROJECT SITE | | | (INCLUDING THE SUITE NUMBER) SHALL BE IN THE TITLE | | | BLOCK OF EACH SUBMITTED PLAN SHEET.PROJECT SITE | | | LOCATION NEEDED ON COVER PAGE OF HYDRAULIC CALCULATION | | | SHEETS ALSO. | | | | | | 02.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 03.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 04.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS | | | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT | | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 05.THE PROJECTED SCOPE OF WORK SHALL NOT INTERFERE OR | | | HINDER ACCESS TO OR EGRESS FROM THE TENANT SPACE, OTHER | | | TENANT SPACES ON THE TENTH FLOOR, OR THE BUILDING. | | | | | | 06.PROVIDE OCCUPANT LOAD AS IN NUMBER OF PERSONS FOR | | | WHOM MEANS OF EGRESS ARE REQUIRED BASED UPON THE | | | CHARACTERISTIC OF THE USE OF THE TENANT SPACE. | | | | | | 07.SPECIFY THE WALL AND CEILING FINISH MATERIAL FOR | | | THE EXITS, AISLE CORRIDORS, AND ALL OTHER SPACES IN | | | TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 08.DOORS THAT LEAD INTO THE EXIT CORRIDOR SHALL BE | | | SELF CLOSING OR AUTOMATIC CLOSING.ALL FIRE RATED | | | DOORS TO COMPLY WITH NFPA 80. | | | | | | 09.PROVIDE A LIFE SAFETY PLAN SHEET WHICH ILLUSTATES | | | TRAVEL DISTANCE TO THE EXITS.EXIT LIGHTS, EMERGENCY | | | LIGHTS, AND LOCATION OF FIRE EXTINGUISHER MAY ALSO BE | | | INCLUDED ON THIS PLAN SHEET. | | | | | | 10.ON SHEET E2.1, EXPLAIN RATIONALE FOR EXIT LIGHTS | | | DIRECTING PATRONS IN CORRIDOR 123 AND 125. | | | | | | 11. SHOW THE LOCATION OF THE 2A:10BC FIRE | | | EXINGUISHER(S) WHICH SATISFIES THE 75' TRAVEL | | | DISTANCE. | | | | | | 12.NO EXIT LIGHTS OR EMERGENCY LIGHTING SHOWN ON SHEET | | | ID-6. CORRELATE WITH SHEET E3.1. | | | | | | 13. THE 2002 EDITION OF NFPA 72 SHALL BE REFERENCED. | | | (SEE NOTE #2 AND #12 ON SHEET FA0.1. | | | | | | 14.AMEND NOTE #17 ON SHEET FA0.1 TO REFLECT LOCAL | | | REQUIREMENT:DELETE "SUPERVISORY SIGNAL ONLY"INSERT | | | "GENERAL FIRE ALARM". | | | | | | 15.EXPLAIN THE DIFFERENCE/RATIONALE IN FIRE ALARM | | | DEVICES LOCATED IN THE TWO CONFERENCE ROOMS (108 AND | | | 117) ONE BEING COMBINATION AUDIBLE/VISUAL AND THE OTHER | | | ONLY VISUAL. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDIACTING WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-03 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-03 |
Time |
12:38 |
Sent To |
P |
|
| Notes |
| 2008-09-03 12:39:03 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-03 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-03 |
Time |
10:27 |
Sent To |
E |
|
| Notes |
| 2008-09-03 10:27:45 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-28 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-28 |
Time |
13:57 |
Sent To |
P |
|
| Notes |
| 2008-08-28 13:58:12 | TO "PLUMB"KEN S. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-18 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-18 |
Time |
08:40 |
Sent To |
E |
|
| Notes |
| 2008-08-18 08:41:05 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2008-07-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-02 |
Time |
10:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-02 |
Time |
10:38 |
Sent To |
B |
|
| Notes |
| 2008-07-02 10:38:35 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-06-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-17 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-17 |
Time |
16:38 |
Sent To |
E |
|
| Notes |
| 2008-06-17 16:39:05 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-23 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-23 |
Time |
11:32 |
Sent To |
E |
|
| Notes |
| 2008-06-04 15:44:59 | 6/3/08--ELECT. SHEETS PULLED FROM REVISION PER | | | CONTRACTOR, AND LUIS MARTINEZ.PLANS ROUTED TO RON | | | REGUEIRO'S DESK. | | 2008-05-23 11:33:25 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-21 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-21 |
Time |
14:07 |
Sent To |
M |
|
| Notes |
| 2008-05-21 14:08:06 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-05 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-05 |
Time |
10:40 |
Sent To |
M |
|
| Notes |
| 2008-05-05 10:41:06 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-20 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-20 |
Time |
15:52 |
Sent To |
B |
|
| Notes |
| 2008-03-20 15:52:53 | TO "JWITME" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-13 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-13 |
Time |
14:39 |
Sent To |
P |
|
| Notes |
| 2008-03-13 14:39:58 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-01-10 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2008-01-10 |
Time |
19:17 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2008-01-10 |
Time |
19:17 |
Sent To |
|
|
| Notes |
| 2008-01-10 19:18:08 | SENT TO COMMERICAL BOARD # 43 MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-15 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-15 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2007-11-27 14:43:51 | TO "COMM" BD#59 | | 2007-11-15 11:42:01 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-14 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-27 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2007-07-27 11:47:15 | TO "COMM" BD#15 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-06 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-06 |
Time |
15:47 |
Sent To |
PC |
|
| Notes |
| 2008-06-06 16:02:59 | ENGINEER LETTER FOR DUCT SIZE CHANGE DATED 5/20/08 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-06 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-06 |
Time |
15:47 |
Sent To |
PC |
|
| Notes |
| 2008-06-06 15:56:56 | PAGE M2.1 REVISION #12 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-21 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-21 |
Time |
15:11 |
Sent To |
PC |
|
| Notes |
| 2008-05-21 15:34:35 | PG M2.1 REVISION 10 CONTAINS THE SEAL OF MIRCEA PELLA | | | BUT APPEARS TO HAVE BEEN SIGNED BY SOMEONE OTHER THAN | | | MR PELLA OR SIGNED BY MR. PELLA IN A MANNER OTHER THAN | | | HIS LEGAL SIGNATURE WHICH IS ON FILE WITH THIS OFFICE. | | | PLEASE PROVIDE PLANS PROPERLY SIGNED AND SEALED BY THE | | | DESIGNER OF RECORD IN ACCORDANCE WITH FS 471. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-02-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-02-04 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-02-04 |
Time |
14:26 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-01-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-01-04 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-01-03 |
Time |
16:56 |
Sent To |
PC |
|
| Notes |
| 2008-01-04 14:34:18 | REVIEW #: 3RD | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | COMMENT #3 IS THE ONLY OUTSTANDING COMMENT FROM | | | PREVIOUS REVIEWS. | | | PG M0.1, REFERENCE TO ASHRAE 62.1-2004 HAS BEEN REMOVED | | | FROM PLANS. CALCULATIONS ARE DECLARED TO BE BASED ON | | | FBC, M TABLE 403.3. HOWEVER, NOTE #2 IN THE | | | CALCULATIONSINDICATES THAT CALCULATIONS ARE BASED ON | | | VARIABLE OR INTERMITTENT OCCUPANCY. THERE IS NO | | | PROVISION FOR SUCH CALCULATIONS RELATED TO TABLE 403.3. | | | THE FULL OUTSIDE AIR RATES ARE TO BE PROVIDED WHENEVER | | | HE SPACES ARE OCCUPIED. ALSO, THE CONFERENCE AND LOBBY | | | AREAS HAVE DIFFERENT OCCUPANT LOADS BASED ON TABLE | | | 403.3 AND THE OUTSIDE AIR REQUIREMENTS FOR THESE AREAS | | | SHALL BE CALCULATED SEPARATELY AND IN ADDITION TO THE | | | OFFICE AREAS. IF TABLE 403.3 IS TO BE USED, PLEASE BASE | | | THE DESIGN ON THE REQUIREMENTS OF THIS SECTION. DO NOT | | | MIX THE REQUIREMENTS OF 403.3 WITH ASHRA 62.1. PLEASE | | | CORRECT AND RESUBMIT. | | | NOTE: IF THIS WERE THE FINAL ISSUE REQUIRED TO BE | | | RESOLVED FOR PERMIT, IT MAY HAVE BEEN COVERED WITH A | | | PROVISO. HOWEVER, A PASSED ELECTRICAL REVIEW IS ALSO | | | PENDING. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-30 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-29 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2007-11-30 11:45:02 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 AMENDMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | | | | | | | NOTE: THE WRITTEN RESPONSE FROM ERDMANN & ASSOCIATES | | | INDICATES THAT RESPONSES TO SEVERAL COMMENTS WERE TO BE | | | PROVIDED BY OTHER PROFESSIONALS. NO SUCH RESPONSES WERE | | | FOUND IN THE RESUBMITTAL PACKAGE. WRITTEN RESPONSES TO | | | REVIEW COMMENTS ARE NOT A REQUIREMENT. HOWEVER, THEY DO | | | SERVE TO EXPEDITE THE PROCESS AND CLARIFY DESIGN | | | INTENT. | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. OK | | | | | | 2. OK | | | | | | 3. THIS COMMENT WAS NOT ADDRESSED. SEE OUTSIDE AIR | | | CALCULATIONS ON PG M0.1. | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6 AND 7: A) ID-1A INDICATES THAT RATED WALLS AT THESE | | | LOCATIONS ARE EXISTING AND PART OF BASE BUILDING PLANS. | | | NO SUCH WALLS ARE SHOWN ON BASE BUILDING PLANS. | | | B) M2.1 SHOWS LAY-IN GRILLS IN CEILINGS FOR ROOMS 104 | | | AND 127, BUT ID-1A CALLS FOR RATED CEILINGS. THERE IS | | | NO INDICATION OF OPENING PROTECTIVES AT THESE CEILING | | | PENETRATIONS. | | | C) M2.1 ROOM 127 SHOWS TWO FIRE DAMPERS INSTALLED AT | | | THE NORTH WALL. ACCORDING TO WALL DETAILS ON ID-1A THIS | | | WALL DOES NOT GO TO DECK, RATHER IT TERMINATES 6 INCHES | | | ABOVE THE CEILING. HOW ARE FIRE DAMPERS TO BE INSTALLED | | | IN THIS WALL? ARE THEY TO BE BELOW THE CEILING? FIRE | | | DAMPERS SHALL BE INSTALLED AS PART OF A RATED ASSEMBLY | | | IN ACCORDANCE WITH FBC, M 607.2. | | | D) HP-1 IS SHOWN PROVIDING SUPPLY AIR TO ROOMS 104 AND | | | 127. RETURN FOR HP-1 AND BASE BUILDING AC SYSTEM ARE | | | SHARING A COMMON RETURN PLENUM AS AIR FROM ROOM 127 IS | | | SHOWN RETURNING TO THE ABOVE CEILING PLENUM. FAN | | | SHUT-DOWN BY SMOKE DETECTOR FOR HP-1 SHALL BE REQUIRED | | | IN ACCORDANCE WITH FBC, M 606.2.2. SMOKE DETECTOR SHALL | | | BE TIED INTO THE BUILDING FIRE ALARM SYSTEM IN | | | ACCORDANCE WITH FBC, M 606.4. | | | E) ACCORDING TO PG ID-1A, HP-1 WILL BE LOCATED ABOVE A | | | FIRE RATED CEILING. SHOW THIS EQUIPMENT TO BE SERVICE | | | ACCESSIBLE IN ACCORDANCE WITH FBC, M 306.1. | | | | | | 8. OK | | | | | | 9. THIS COMMENT HAS BEEN ADEQUATELY ADDRESSED. THERE IS | | | NO CODE DEFICIENCY RELATED TO THIS COMMENT. | | | FOR INFORMATION PURPOSES ONLY: BASED ON A CONFERENCE | | | WITH DAVID ALLEN AND TOM JOYNER (AHA ENGINEERING), | | | FIRE/SMOKE DAMPERS ARE NOT REQUIRED IN TENANT | | | SEPARATION WALLS FOR THE FUNCTION OF THE SMOKE CONTROL | | | SYSTEM. THIS CHANGE MAY BE INCORPORATED INTO AN UPDATED | | | TENANT DESIGN MANUAL. CONSULT WITH BUILDING MANAGEMENT | | | REGARDING THIS CHANGE AS CHANGING THIS DESIGN PRIOR TO | | | RESUBMITTAL COULD ELIMINATE THE NEED FOR REVISIONS | | | RELATED TO THESE AREAS AFTER PERMIT ISSUANCE. | | | | | | 10. OK | | | | | | 11. COMPLIANCE WITH FBC 13-411.1.ABC.1.4 FOR WATER FLOW | | | CONTROLS HAS NOT BEEN SHOWN. | | | | | | 12. OK | | | | | | 13. OK | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-05 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-05 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2007-08-05 15:33:36 | ---------------DENIED----------------- | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 AMENDMENTS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. BASED ON THE DETERMINATION OF THE BUILDING OFFICIAL, | | | APPLICATIONS FOR TENANT IMPROVEMENT PERMITS PRIOR TO | | | C.O. OF THE BASE BUILDING REQUIRE SHOP DRAWING REVIEW | | | BY THE BASE BUILDING DESIGNER(S) OF RECORD. HAVE | | | DESIGNER(S) OF RECORD REVIEW CONSTRUCTION DOCUMENTS | | | PRIOR TO RESUBMITTAL AND, IF FOUND SUFFICIENT, AFFIX | | | THEIR SHOP DRAWING REVIEW STAMP AND SIGNATURE ON SAID | | | DOCUMENTATION. | | | | | | 2. AT THIS TIME THE BUILDING IS NOT EXISTING AS A C.O | | | HAS NOT BEEN ISSUED. ADDITIONALLY, THE ENERGY | | | CALCULATIONS FOR THE BASE BUILDING ARE BASED ON | | | ASSUMPTIONS FOR A SHELL BUILDING UNDER FBC 13-101.1.6. | | | UNLESS THE BUILDING IS COMPLETED AS PER ALL ASSUMPTIONS | | | MADE IN THE ORIGINAL CODE COMPLIANCE SUBMITTAL, A | | | REVISED CODE SUBMITTAL(S) USING METHODS A, B OR C SHALL | | | BE SUBMITTED WHEN COMPLETION OF THE BUILDING (OR PART | | | OF THE BUILDING) IS PERMITTED. | | | | | | 3. M0.1: IN SEVERAL LOCATIONS, SCHEDULES REFERENCE | | | ASHRAE 62-01. NOTE THAT PER FBC 2004 W/ 2006 UPDATES, | | | THE CORRECT REFERENCE STANDARD IS ASHRAE 62.1-2004. | | | ALSO, THE CODE ALLOWS FOR COMPLIANCE WITH ETHER FBC,M | | | TABLE 403.3 OR ASHRAE 62.1-2004. RATHER THAN CITING | | | BOTH STANDARDS AT ONCE, ONE METHOD OF COMPLIANCE OR THE | | | OTHER SHOULD BE DECLARED ON PLANS. FBC 106.1.1 | | | | | | 4. M0.1 FAN SCHEDULE: CONTROL FOR EXHAUST FANS IS | | | STATED AS "LIGHT INTERLOCK." EXHAUST FANS IN TOILET | | | ROOMS SHALL RUN CONTINUOUS OR WHENEVER AIR IS BEING | | | SUPPLIED TO THE SPACE AS ALL AIR SUPPLIED TO SPACES | | | REQUIRED TO HAVE MECHANICAL EXHAUST SHALL BE EXHAUSTED | | | PER FBC,M 403.2.1. | | | NOTE: PROVISIONS SHALL ALSO BE MADE TO ASSURE | | | VENTILATION IS PROVIDED WHENEVERA ROOM OR SPACE IS | | | OCCUPIED PER FBC,M 401.3. | | | | | | 5. M2.1: EF-1 AND EF-2 DUCTS ARE UNDER POSITIVE | | | PRESSURE AND THEREFORE SHALL NOT BE LOCATED IN OR PASS | | | THROUGH A PLENUM PER FBC,M 601.3. | | | | | | 6. M2.1 NOTE #8: THIS NOTE INDICATES WALLS ARE ONLY TO | | | EXTEND TO CEILING HEIGHT. HOWEVER, FLOOR PLAN AND WALL | | | DETAIL ON PG ID-1A SHOW THE WALL BETWEEN ROOMS 103 AND | | | 104 AS TYPE "B" WHICH IS CONTINUOUS FROM FLOOR TO DECK. | | | THIS WILL NOT ALLOW FOR RETURN OF AIR IN PLENUM SPACE | | | TO THE AIR HANDLING EQUIPMENT. COORDINATE PLANS AND | | | SHOW HOW BALANCED RETURN IS TO BE ACHIEVED IN | | | ACCORDANCE WITH FBC,M 601.4. | | | | | | 7. M2.1 GENERAL NOTES: NOTE CALLS FOR NO CEILING IN | | | ROOM 104. HOWEVER, FLOOR PLAN SHOWS 24X24 LAY-IN TYPE | | | DIFFUSERS AND GRILLS. PLAN ALSO SHOWS HP-1 ABOVE A | | | CEILING WITH AN ACCESS PANEL. PLEASE CLARIFY. ALSO, IF | | | THERE IS NO CEILING IN ROOM 104, IT MAY BE CONSIDERED | | | PART OF THE PLENUM SPACE AND WILL BE SUBJECT TO THE | | | RESTRICTIONS OF FBC,M 602.2.1 AND NFPA 90A-02 SEC | | | 4.3.10. | | | | | | 8. M2.1: SIZES OF LARGE RECTANGLE DUCTS FROM MECH ROOM | | | ARE NOT SHOWN ON PLANS. PLEASE CLARIFY AND RESUBMIT. | | | | | | 9. INSTALLATION OF FIRE DAMPERS IN TRANSFER OPENINGS IN | | | THE NEW TENANT SEPARATION WALLS MAY INTERFERE WITH THE | | | PERFORMANCE OF THE BASE BUILDING SMOKE CONTROL SYSTEM | | | AND AS SUCH IS PROHIBITED PER FBC,M 607.2.1. PLEASE | | | SHOW MEANS OF APPROVED ALTERMANTIVE PROTECTION FOR | | | THESE OPENINGS. | | | | | | 10. M2.1: SOME GRILL AND CFM DESIGNATIONS ARE MISSING | | | FROM PLAN IN ROOM 102. PLEASE CORRECT AND RESUBMIT. | | | | | | 11. M2.1: HP-1, PLEASE SHOW SOURCE AND ROUTING OF | | | CONDENSER WATER PIPING FOR THE HEAT PUMP. ALSO SHOW THE | | | MEANS AND LOCATION OF CONDENSATE DISPOSAL TO BE IN | | | COMPLIANCE WITH FBC,M SEC 307.2. NOTE: ALSO SHOW | | | COMPLIANCE WITH FBC 13-411.1.ABC.1.4 FOR WATER FLOW | | | CONTROLS. | | | | | | 12. M5.1 SOUND BOOT DETAIL: PLEASE REFERENCE THE | | | CORRECT CODE UNDER WHICH THIS PROJECT IS DESIGNED (FBC | | | 2004). | | | | | | 13. ENGINEER HAS NOT USED FULL SIGNATURE TO SIGN/SEAL | | | MECHANICAL PLANS AS REQUIRED BY F.S. 471. IT APPEARS | | | THAT THE ENGINEER HAS USED INITIALS WHEN COMPARED TO | | | THE FULL SIGNATURE WHICH WAS USED TO SIGN/SEAL THE | | | PLUMBING PLANS IN THIS SAME SET OF DRAWINGS. PLEASE | | | CORRECT AND RESUBMIT. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-09 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-09 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2008-09-09 12:15:51 | SUBMITTAL OK -- ROHL A3606LM FAUCET -- NSF-61 COMPLIANT | | | UNDER ASME A112.18.1-2005/CSA125.1-05 TESTING (SEE | | | STANDARDS) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2008-09-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-05 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-05 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2008-09-05 10:36:28 | SUBMITTAL DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | | | | 1. SUBMITTAL SUBMITTED SHOWS COMPLIANCE WITH THE | | | REQUIREMENTS OF ASME & CSA STANDARDS, BUT NOT FOR THE | | | NSF-61 REQUIREMENT INDICATED IN SECTION 424.1. PLEASE | | | SUBMIT NSF-61 LISTING FOR THE FAUCET OR HAVE THE FAUCET | | | TESTED BY AN APPROVED TESTING AGENCY INDICATING THAT | | | THE FAUCET CONFORMS TO THE NSF-61 REQUIREMENT ALONG | | | WITH THE SUBMITTAL FROM IAPMO SUBMITTED FOR APPROVAL. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-03 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-03 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2008-09-03 07:41:57 | REVISION OK -- SHT P0.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-03-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-03-29 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-03-29 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2008-03-29 16:09:03 | REVISIONS APPROVED.--SHT PO.1 SEE PROVISO FROM | | | PREVIOUS REVIEW, AND PROVISO WHA REQD ON D.W SUPPLY | | | LINE. 604.9.--SHT P2.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-27 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-27 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2007-12-27 16:24:02 | | | | | | | | | | | | | PASSED/PROVISO: | | | BREAK ROOM SINK NOT APPROVED. MANUF. SPECIFICATION | | | SHEETS DO NOT SHOW THE FAUCET MEETING THE STANDARDS | | | REQUIRED IN SECTION 424.1. MANUF. SPECIFICATIONS SHALL | | | MEET THE REQUIREMENTS OF ASME A112.18.1 OR SCA B125 AS | | | WELL AS NSF-61 SECTION 9. THIS INFORMATION IS REQUIRED | | | AT THE TIME OF PLUMBING FINAL. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-03 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-03 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2007-12-03 16:46:11 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | | | | 4. THE BASE BUILDING HAS NOT RECIEVED A CERTIFICATE OF | | | OCCUPANCY AT THIS TIME. THE BUILDING OFFICIAL HAS | | | DETERMINED THAT ALL PLANS SHALL BE REVIEWED BY THE | | | DESIGNERS OF THE BASE BUILDING FOR ALL TENANT | | | BUILDOUTS. PLANS SHALL BE STAMPED AS REVIEWED BY BASE | | | BUILDING DESIGN TEAM PRIOR TO RESUBMITTING FOR REVIEW | | | AT THE CITY WPB. (SEE COMMENTS BY MECHANICAL REVIEW, | | | (1), ELECTRICAL REVIEW, (4), AND BUILDING (2)).-- | | | SINCE THE BUILD-OUT G.C. IS A DIFFERENT COMPANY FROM | | | THE BASE BUILDING G.C., A LETTER IS REQUIRED FROM THE | | | DEVELOPER, SIGNED BY THE BASE BUILD G.C. AND THE SHELL | | | G.C., STATING THAT ALL PARTIES UNDERSTAND THAT NO | | | DISPUTE OVER WORK SCOPE OR RESPONSIBILITY CAN COME | | | BEFORE THE REQUIREMENT FOR COMPLIANCE WITH FLORIDA | | | BUILDING CODE. | | | ****RESPONSE NOTED, BUT THE LETTER REQUESTED FROM THE | | | DEVELOPER, SIGNED BY THE GENERAL CONTRACTORS HAS NOT | | | BEEN SUBMITTED. | | | | | | 5. SHTS ID-1 THRU ID-15 SHALL HAVE THE SIGNATURE AND | | | DATE THE SEAL AND SIGNATURE WERE AFFIXED TO PLANS. IT | | | APPEARS THAT INITIALS HAVE BEEN USED IN PLACE OF | | | SIGNATURE WHEN SEALING THE PLANS. IF THIS INDEED THE | | | LEGAL SIGNATURE OF THE INTERIOR DESIGNER, THEN A | | | SIGNED, SEALED, NOTORIZED LETTER INDICATING THE | | | INTERIOR DESIGNER'S LEGAL SIGNATURE SHALL BE SUBMITTED | | | FOR OUR FILES. FAC 61G1-16.003,61G1-16.004(5) & | | | 481.2055. | | | ****RESPONSE NOTED, BUT THE DATE THAT THE SIGNATURE AND | | | SEAL WERE AFFIXED ON THE PLANS HAS NOT BEEN INDICATED | | | AS REQUIRED. | | | | | | 6. OK | | | 7. OK | | | 8. OK | | | 9. OK | | | | | | 10. SUBMIT A DETAIL FOR THE TOILET ROOM FIXTURES | | | SHOWING COMPLIANCE WITH SECTIONS 11-4.16, 11-4.17, | | | 11-4.19 & 11-4.21 WITH ALL SUBSECTIONS. SHOW THE CLEAR | | | FLOOR SPACE FOR ALL ACCESSIBLE FIXTURES ON THE FLOOR | | | PLAN AS WELL AS THE TURNING AREA IN BOTH TOILET ROOMS. | | | SUBMIT ELEVATIONS TO SHOW COMPLIANCE FOR ALL OTHER | | | REQUIREMENTS. | | | ****RESPONSE NOTED, BUT COMPLIANCE FOR THE FOLLOWING IS | | | NOT SHOWN: | | | ___FOR THE W/C'S | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.4 GRAB BARS (42" REQD ON SIDE) | | | THE LAV FAUCET SHOWN ON THE PLAN IS A KOHLER MODEL | | | PK272, BUT THE ATTACHED SPECIFICATION BOOK INDICATES | | | THE FAUCET AS A KOHLER MODEL K-394, (APPROVED), PLEASE | | | CLARIFY AND CORRELATE. | | | | | | 11. OK | | | | | | 12. THE SINK IN THE BREAKROOM, (ROOM #112), SHALL BE | | | ACCESSIBLE. PLEASE SUBMIT A DETAIL SHOWING COMPLIANCE | | | WITH SECTION 11-4.24 AND ALL SUBSECTIONS. ELEVATION | | | A1/ID-14 INDICATES CABINET DOORS. THE DOORS ARE NOT | | | APPROVED IN THE CLEAR FLOOR SPACE AND SHALL BE DELETED | | | FROM DETAIL. FORWARD APPROACH IS REQUIRED. SHOW CLEAR | | | FLOOR SPACE ON THE FLOOR PLAN AND OTHER REQUIREMENTS ON | | | THE ELEVATION. (NOTE: THE GARBAGE DISPOSAL SHALL BE ADA | | | APPROVED. PLEASE SUBMIT MANUF. SPECIFICATION SHEETS | | | SHOWING APPROVAL). | | | ****RESPONSE NOTED, BUT COMPLIANCE NOT SHOWN FOR | | | SECTION 11-4.24.7 FAUCET, AND THE GARBAGE DISPOSAL | | | SEPCIFICATION SHEETS HAS NOT BEEN SUBMITTED. | | | | | | 13. OK | | | | | | 14. DELETED - OK | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-01 |
Time |
13:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-01 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2007-09-01 14:02:33 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. INTERIOR DESIGN DOCUMENTS PREPARED BY A REGISTERED | | | INTERIOR DESIGNER SHALL CONTAIN A STATEMENT THAT THE | | | DOCUMENT IS NOT AN ARCHITECTURAL OR ENGINEERING STUDY, | | | DRAWING, SPECIFICATION OR DESIGN AND IS NOT TO BE USED | | | FOR CONSTRUCTION OF ANY LOAD BEARING COLUMNS, | | | LOAD-BEARING FRAMING OR WALLS OF STRUCTIURES, OR | | | ISSUANCE OF ANY BUILDING PERMIT, EXCEPT AS OTHERWISE | | | PROVIDED BY LAW.FS 481.2131. PLEASE SHOW COMPLIANCE. | | | | | | 2. INDICATE WHICH CODES PLANS WERE DESIGNED TO AND | | | OCCUPANCY CLASSIFICATION ON THE PLANS. SECTIONS 106.1.1 | | | & 106.3.5.1.1(2)(7). | | | | | | 3. ALL SHEETS REQUIRE THE ADDRESS AND TENANT SPACE IN | | | THE TITLE BLOCK PER SECTION 106.1.1. FLORIDA | | | ADMINISTRATIVE CODE. AFTER SUITE NUMBER IS ASSIGNED | | | PLEASE INDICATE ADDRESS & SUITE NUMBER IN TITLE BLOCK. | | | | | | 4. THE BASE BUILDING HAS NOT RECIEVED A CERTIFICATE OF | | | OCCUPANCY AT THIS TIME. THE BUILDING OFFICIAL HAS | | | DETERMINED THAT ALL PLANS SHALL BE REVIEWED BY THE | | | DESIGNERS OF THE BASE BUILDING FOR ALL TENANT | | | BUILDOUTS. PLANS SHALL BE STAMPED AS REVIEWED BY BASE | | | BUILDING DESIGN TEAM PRIOR TO RESUBMITTING FOR REVIEW | | | AT THE CITY WPB. (SEE COMMENTS BY MECHANICAL REVIEW, | | | (1), ELECTRICAL REVIEW, (4), AND BUILDING (2)).-- | | | SINCE THE BUILD-OUT G.C. IS A DIFFERENT COMPANY FROM | | | THE BASE BUILDING G.C., A LETTER IS REQUIRED FROM THE | | | DEVELOPER, SIGNED BY THE BASE BUILD G.C. AND THE SHELL | | | G.C., STATING THAT ALL PARTIES UNDERSTAND THAT NO | | | DISPUTE OVER WORK SCOPE OR RESPONSIBILITY CAN COME | | | BEFORE THE REQUIREMENT FOR COMPLIANCE WITH FLORIDA | | | BUILDING CODE. | | | | | | 5. SHTS ID-1 THRU ID-15 SHALL HAVE THE SIGNATURE AND | | | DATE THE SEAL AND SIGNATURE WERE AFFIXED TO PLANS. IT | | | APPEARS THAT INITIALS HAVE BEEN USED IN PLACE OF | | | SIGNATURE WHEN SEALING THE PLANS. IF THIS INDEED THE | | | LEGAL SIGNATURE OF THE INTERIOR DESIGNER, THEN A | | | SIGNED, SEALED, NOTORIZED LETTER INDICATING THE | | | INTERIOR DESIGNER'S LEGAL SIGNATURE SHALL BE SUBMITTED | | | FOR OUR FILES. FAC 61G1-16.003,61G1-16.004(5) & | | | 481.2055. | | | | | | 6. SHT ID-1A IF TOILET STALLS ARE PROVIDED, THAN AT | | | LEAST ONE SHALL BE A STANDARD TOILET STALL COMPLYING | | | WITH SECTION 11-4.17 EXCEPTION: NEW CONSTRUCTION(1) AND | | | SHALL CONTAIN AN ACCESSIBLE LAVATORY WITH IT. (SEE FIG. | | | 11-30(E). | | | | | | 7. SHT ID-2 WHITE OUT OR HAND WRITTEN CHANGES ARE NOT | | | APPROVED ON SIGNED, SEALED PLANS. SECTION 106.1.3. | | | | | | 8. SHT ID-3 FLOOR FINISH SCHEDULE. MORE INFORMATION | | | REQUIRED. PER SECTION 1210.1 THE FLOOR SHALL HAVE A | | | "SMOOTH, HARD, NONABSORBENT" SURFACE. PLEASE SUBMIT THE | | | MANUF. SPECIFICATION FOR THE MEDIUM SATURNIA INDICATED | | | ON THE SCHEDULE TO VERIFY COMPLIANCE. SECTION 106.1.2. | | | | | | 9. SHT ID-3B WALLS WITHIN 2FT OF THE WATER CLOSETS | | | SHALL HAVE A "SMOOTH, HARD, NONABSORBENT" SURFACE UP TO | | | 4FT ABOVE THE FLOOR. PLEASE INDICATE COMPLIANCE WITH | | | SECTION 1210.2. | | | | | | 10. SUBMIT A DETAIL FOR THE TOILET ROOM FIXTURES | | | SHOWING COMPLIANCE WITH SECTIONS 11-4.16, 11-4.17, | | | 11-4.19 & 11-4.21 WITH ALL SUBSECTIONS. SHOW THE CLEAR | | | FLOOR SPACE FOR ALL ACCESSIBLE FIXTURES ON THE FLOOR | | | PLAN AS WELL AS THE TURNING AREA IN BOTH TOILET ROOMS. | | | SUBMIT ELEVATIONS TO SHOW COMPLIANCE FOR ALL OTHER | | | REQUIREMENTS. | | | | | | 11. PER TABLE 403.1 A DRINKING FOUNTAIN IS REQUIRED. | | | PLEASE SHOW THE LOCATION AND SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTION 11-5.15 AND ALL SUBSECTIONS AS | | | WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | | | | 12. THE SINK IN THE BREAKROOM, (ROOM #112), SHALL BE | | | ACCESSIBLE. PLEASE SUBMIT A DETAIL SHOWING COMPLIANCE | | | WITH SECTION 11-4.24 AND ALL SUBSECTIONS. ELEVATION | | | A1/ID-14 INDICATES CABINET DOORS. THE DOORS ARE NOT | | | APPROVED IN THE CLEAR FLOOR SPACE AND SHALL BE DELETED | | | FROM DETAIL. FORWARD APPROACH IS REQUIRED. SHOW CLEAR | | | FLOOR SPACE ON THE FLOOR PLAN AND OTHER REQUIREMENTS ON | | | THE ELEVATION. (NOTE: THE GARBAGE DISPOSAL SHALL BE ADA | | | APPROVED. PLEASE SUBMIT MANUF. SPECIFICATION SHEETS | | | SHOWING APPROVAL). | | | | | | 13. WHEN RESUBMITTING PLANS, PLEASE INDICATE THE | | | REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | SUBMIT ONE COPY OF SHEETS REMOVED FOR COMPARISON. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 14. SHT P31 SHOWS NO PLUMBING INFORMATION. PLEASE | | | CLARIFY. THERE SEEMS TO BE ELECTRIC OR MECHANICAL | | | INFORMATION THAT SHOULD BE TRANSFERED TO THE RESPECTIVE | | | ELECTRIC OR MECHANICAL SHEETS. SECTION 106.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy