Plan Review Details - Permit 07070315
| Plan Review Stops For Permit 07070315 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-08-14 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-08-14 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2007-08-14 11:42:51 | SITE ADDRESS REMAINS AS 9055 IBIS BLVD FOR THE NEW | | | BUILDING SINCE THE EXISTING STRUCTURE WILL BE | | | DEMOLISHED. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-28 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-27 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2007-11-28 16:18:04 | ****CORRECTIONS**** | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY PRIOR | | | TO PERMIT ISSUANCE.THE PLANS MUST BE STAMPED AND THE | | | RECEIPT PROVIDED.PLEASE CALL 233-5025 FOR MORE | | | INFORMATION. | | | | | | 2.A7.0 SHOWS 42'7" TO TOP OF BEAM.HOW CAN THE MEAN | | | ROOF HEIGHT BE 40'?PLEASE CLARIFY DESIGN CRITERIA. | | | | | | 3.EXPOSURE B IS DECLARED.AERIALS SHOW OPEN AREA | | | EXCEEDING 600FEET.PLEASE PROVIDE INFORMATION | | | REGARDING EXPOSURE B CONDITION AS IT APPEARS TO BE | | | EXPOSURE C.PLEASE NOTE THAT THE DEFINITION OF | | | EXPOSURE C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 | | | FBC1609.4, FBC R301.2.1.4 (AVAILABLE AT | | | WWW.FLORIDABUILDING.ORG).NOTE THAT FOR COMPONENTS AND | | | CLADDING, COEFFICIENT FOR 45 FEET, EXPOSURE C IS 1.53 | | | (FBC TABLE 1609.6.2.1(4).HOW DOES THIS AFFECT MWFRS? | | | | | | | | | 4.PLEASE NOTE THAT GOVERNING CODE INCLUDES 2007 | | | AMENDMENTS EFFECTIVE JULY 1, 2007. | | | | | | 5.PROVIDE LOUVER PRODUCT APPROVALS. | | | | | | 6.THE MECHANICAL ENGINEER HAS REVISED THE STRUCTURAL | | | ENGINEER'S DESIGN ON SHEET M7.2.PLEASE INCORPORATE | | | INTO STRUCTURAL SHEETS.ALSO PLEASE NOTE THAT THERE IS | | | NO VERTICAL REINFORCEMENT AT BOTH SIDES; HAS THE | | | STRUCTURAL ENGINEER DETERMINED THAT THIS IS NOT | | | NECESSARY FOR THIS TWO STORY BUILDING? | | | | | | 7.PLEASE SEE PREVIOUS COMMENT #20 REGARDING HEADROOM, | | | FBC11-4.4.2.CLEARANCE AT LANDINGS IS CLEAR, BUT WHAT | | | ABOUT THE STAIRS LEADING TO THIS LANDING? | | | | | | 7.PLEASE NOTE THAT IF THIS PLAN PASSES OTHER REVIEWS, | | | PROVISO ITEMS CAN BE CONSIDERED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
jjohnsto |
Date |
2007-09-04 |
Time |
10:43 |
Rev Time |
11.00 |
| Received By |
jjohnsto |
Date |
2007-09-04 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2007-09-04 10:49:37 | CONSTRUCTION SERVICES DEPARTMENT | | | 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH, | | | FLORIDA33401 | | | TEL:561-805-6713FAX: | | | 561-805-6731 | | | | | | JAMES JOHNSTON,CBO PERMIT NO. 07070315 | | | BUILDING PLAN EXAMINERII ADDRESS 9055 IBIS | | | E-MAIL:JJOHNSTON @WPB.ORG PROJECT: KITSON | | | CORPORATE OFFICE CONTRACTOR: SHAKMAN | | | HOSPITALITY LLC | | | DATE: AUGUST30,2007 | | | | | | PLANREVIEW | | | | | | 109.3.10.1HURRICANE PROTECTION | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW | | | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO | | | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION | | | SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE | | | DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. | | | ANY PERSONS WHO FAIL TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO | | | THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO | | | SECTION 113 OF THIS CHAPTER. | | | | | | SUBMITTING PLAN CORRECTIONS | | | WHEN RE-SUBMITTING PLANS WITH CORRECTIONS PLEASE | | | PROCEED AS FOLLOWS: | | | A.INDICATE THE CORRECTED ITEMS BY CLOUDING ON THE | | | NEW CORRECTED SHEET | | | B.REMOVE THE OLD SHEET FROM THE PLAN AND INSERT THE | | | NEWLY CORRECTED SHEET | | | C.PUT OLD THE OLD SHEETS TOGETHER AS ONE SET AND | | | SUBMIT TO THE BUILDING DEPT. ALONG | | | WITH THE NEW CORRECTED PLANS. THIS IS NECESSARY | | | FOR THE PLAN REVIEWER TO CRITIQUE | | | THE CORRECTION REQUIRED FROM THE PREVIOUS PLAN | | | REVIEW. | | | D.SUBMIT A COVER LETTER IDENTIFYING THE CORRECTION | | | MADE LISTING THE ITEM REFERENCED | | | IN THE REVIEWER?S COMMENTS. | | | | | | 61G1-16.004TITLE BLOCK | | | LANDSCAPE ARCHITECT? URBAN DESIGN STUDIOS | | | A TITLE BLOCK ON ALL ARCHITECTURAL OR INTERIOR DESIGN | | | DRAWINGS AND SPECIFICATION INDICATION SHEETS. THE TITLE | | | BLOCK MUST AT A MINIMUM CONTAIN THE FOLLOWING | | | INFORMATION: | | | FIRM NAME,ADDRESS,TELEPHONE NUMBER | | | FIRM LICENSE NUMBER,CERTIFICATE OF AUTHORIZATION NAME | | | OR IDENTIFICATION OF PROJECT | | | DATE PREPARED | | | A SPACE FOR THE SIGNATURE AND DATED SEAL | | | A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING THE | | | DOCUMENT | | | | | | | | | ICE ? INTERNATIONAL CONSULTING ENGINEERS, INC. | | | UP-DATE YOUR ADDRESS. IT DOES NOT CONFORM TO THE DBPR | | | RECORDS | | | | | | 2. FBC506.2506.3AREA INCREASE | | | NOTE ON PLAN ALLOWED PER CODE DEFINED | | | | | | WINDOWS / DOORS PRODUCT APPROVALS | | | PRODUCT APPROVALS ARE REQUIRED FOR WINDOWS / | | | DOORS/MULLIONS/ROOFING ASSEMBLIES | | | WPB ADMINISTRATIVE CODE 106.3 REGULATED BY DCA RULE | | | 9B-72FLORIDA PRODUCT APPROVAL | | | SUBMIT TWO COPIES OF EACH APPROVAL WITH | | | FLORIDA PRODUCT APPROVAL COVER SHEET THE ARCHITECT?S / | | | ENGINEER?S SIGNATURE AS APPLICABLE, STATING TO THE BEST | | | OF THEIR KNOWLEDGE THE | | | PRODUCT APPROVAL COMPLIES WITH THE PLANS | | | AND SPECIFICATIONS.SEE:WEB SITE | | | WWW.FLORIDABUILDING.COM | | | NOTE: SEE DIVISION FACTOR TO BE USED IN DESIGN | | | PRESSURE BY LEGACYFPA | | | | | | SUBMIT PRODUCT APPROVALS WIDTH FLORIDA | | | PRODUCT APPROVAL COVER | | | PAGE FOR THE FOLLOWING | | | FIXED GLASS | | | MULLION TUBES | | | STORE FRONT GLAZING SYSTEM | | | ALUMINUM OUT SWING DOORS | | | HOLLOW METAL DOORS | | | TRUSS ANCHORS | | | | | | FBC13-100.2 ENERGY CALCULATIONS | | | COVER SHEET ENERGY CALCULATIONS INFORMATION. THIS IS A | | | 2 STORY BUILDING | | | COMPLETE OWNER AND ADDRESS INFORMATION | | | FIRST FLOOR UN-FINISHED | | | SECOND FLOOR FINISHED | | | ENTER CORRECT SQUARE FOOTAGE FIRST AND | | | SECOND FLOOR | | | | | | FBC-13-400. A METHOD A IS FOR A COMPLETED | | | BUILDING AND STATES ( 2NDPARAGRAPH) EXCEPT | | | DESIGNS WITH NO MECHANICAL SYSTEM. | | | FBC-13-400.2.A.2 SHELL BUILDING ON THE FIRST FLOOR | | | FBC-13-400.3.C METHOD CFOR THE 2ND FLOOR | | | ZONE 1IS THE LOBBY NOT RECEPTIONIST AREA | | | WINDOWTYPE A ON FIRST FLOOR(44) NOT 40 | | | COMPLETE ALL ITEMS WITH CORRECT INFORMATION | | | | | | FBCTABLE 1609.6.2 (14)MEAN ROOF HEIGHT | | | USE 40 FEET. PROVIDE ON PLAN EXPOSURE B, | | | ADJUSTMENT FACTOR 1.09 | | | FBCTABLE 1609.6.2 (12)NET DESIGN WIND PRESSURE | | | | | | PRODUCT APPROVALS | | | ROOF TILEPRODUCT APPROVAL LEGACYREPORT | | | PLAN STATES SPANISH SROOF TILE | | | TABLE 3 PAGE 8 OF 12 EXPOSURE BWIND LOADS | | | AT 140 MPH, MEAN ROOF HEIGHT 40,UPLIFT28 | | | BASED ON THIS INFORMATION, HIGHLIGHT | | | FASTENERS TO BE USED ON USED ON TABLE 2 SCHEDULE | | | TAMKO FLORIDA PRODUCT APPROVAL HAS EXPIRED | | | | | | CANOPIES | | | STATE ON PLANS ?ALL CANOPIES UNDER SEPARATE | | | PERMIT? | | | | | | 1906.2.2.1SHORING & RESHORING | | | SUBMIT PLAN FOR REMOVAL OF SHORES AND | | | RE-SHORING | | | | | | SHEET S-4 | | | STRUCTURAL NOTES - INCLUDE THE STATEMENT 2004 | | | FBC WITH 2006 SUPPLEMENTS | | | | | | SHEETLS-1 | | | NOTE ON PLAN AREA INCREASE ALLOWEDFBC-506.2 & | | | 506.3 | | | | | | FBC -3006.1 ELEVATOR MACHINE ROOM | | | CAN?T HAVE A MACHINE ROOM LOCATED IN A TENANT SPACE | | | | | | ELEVATOR PITWATERPROOFINGFBC1802.2.3 FBC | | | 1807.2.2 FBC1807.3.3 | | | PROVIDE INFORMATION ON PLAN FOR SLAB ELEVATION AT BASE | | | OF SHAFT AND WATERPROOFING OF WALLS AND SLAB | | | | | | | | | 3. FBC -3006.1 ELECTRICAL ROOM | | | CAN?T HAVE AN ELECTRICAL ROOM LOCATED IN A TENANT | | | SPACE | | | | | | 11-4.6.4SINAGEHANDICAP SIGN | | | PROVIDE THE DETAIL OF HANDICAP SIGN WITH HEIGHT, | | | REQUIRED INFORMATION ON SIGN, SYMBOL | | | | | | DOOR SCHEDULE | | | IDENTIFY THE DOORS ON THE FLOOR PLAN AS DESCRIBED ON | | | DOOR SCHEDULE | | | | | | FBC-11-4.4.2 FIGURE8-C-1 HEADROOM | | | A-7.2A-7.3VERIFY HEADROOM FIRST FLOOR TO LANDING | | | | | | FBC ? 11-7.2COUNTER ACCESSIBILITY | | | (1)36?MAX HEIGHT COUNTER | | | (2)FOLDING SHELF | | | | | | FBC-11-4.13.5ROOM 219 | | | CLEAR WIDTH ON LATCH SIDE OF DOOR IN OUT-SWING | | | POSITION REQUIRES 18? | | | | | | FBC-11-4.1.3(11)ALL TOILET ROOMS SHALL BE | | | ADAPTABLE | | | THIS MEANS THE TOILET ROOMS SHALL REQUIRE THE CORRECT | | | WIDTH AND REQUIRED BACKING FOR HANDICAP | | | FIXTURES SHOULD THEY BE NEEDED IN THE FUTURE. | | | | | | FBC-1210.2RESTROOMS | | | GYPSUM BOARD MUST BE NON-ABSORBENT, NOTE ON PLANS | | | | | | FBC-11-4.23, 11-4.24-7ACCESSIBILITY | | | LUNCH ROOM SPACE 240NEEDS CLEAR FLOOR SPACE UNDER | | | SINKS FOR FORWARD APPROACH | | | | | | FBC-1609 GENERATOR | | | SUBMIT SPECIFICATIONS, FASTENING TO SLAB FOR MOMENT OF | | | OVERTURNING | | | | | | FBC- 1406.2.2EIF?S | | | ARCHITECTURAL TRIM OVER 40 FEET IN HEIGHT | | | A-5.1 CANNOT BE COMBUSTIBLE | | | | | | STRUCTURAL SHEET1-5.2 | | | PROVIDE SECTION THROUGH GUARD RAIL (RAILING) DETAIL | | | 1-2-3 | | | | | | STRUCTURAL SHEETWINDOW JAMBS | | | IDENTIFY DOWELS IN MASONRY UNITS | | | | | | ARCHITECTURAL SHEETA-10.0BALCONY | | | REQUIRES SECOND DRAIN | | | | | | TRUSSES-TRUSS REPORT | | | LATERAL LOADS NOT IN COMPLIANCE,CHECK CHART WITH | | | SIMPSON@ WWW.STRONGTIE.COM | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-12 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-12 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-30 |
Time |
13:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-30 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2007-11-30 13:03:25 | | | | | | | | | | | | | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE THERE ARE SOME ITEMS FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING. | | | PLEASE ALSO SEE NEW COMMENTS BASED ON SOME INFORMATION | | | ONLY NOW SUBMITTED FOR REVIEW. | | | | | | | | | 1) NOTE: PLEASE PROVIDE AND SUBMIT THE ORIGINAL PERMIT | | | APPLICATION BACK WITH THE RESUBMITTED PLANS FOR THIS | | | SCOPE OF WORK. PLEASE SEE THE PERMIT APPLICATION WHICH | | | WAS SUBMITTED AND PLACED IN PACKAGE WAS FOR PERMIT | | | #07070314 FOR SITE CLEARANCE AND DEMO/SITE WORK. | | | | | | 2) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE #5 REQUESTED | | | THE MANUFACTURES SPECS/CUT SHEETS FOR THE | | | GENERATOR/FUEL TANK AND ATS TO BE SUBMITTED. THE SHEETS | | | FOR THE GENERATOR WAS SUBMITTED HOWEVER NOT THE SHEETS | | | FOR THE ATS. | | | PLEASE ALSO SEE NO SPECS WERE SUBMITTED FOR FUEL TANK | | | FOR REVIEW BY FIRE AND MECHANICAL. | | | PLEASE KNOW THESE ARE REQUIRED AT THIS TIME. PLEASE SEE | | | COMMENTS FROM OTHER TRADES SUCH AS MECHANICAL FOR | | | POSSIBLE COMMENTS. | | | PLEASE PROVIDE MINIMUM CLEARANCE INFORMATION FOR THE | | | GENERATOR ON ALL SIDES OF UNIT. THE SIDE FACING THE | | | CONDENSING UNITS SEEMS TO BE LESS THAN THE MINIMUMS | | | WHICH THIS OFFICE HAS SEEN AS SET-FORTH FROM | | | MANUFACTURE AND RECOMMENDED CLEARANCES. PLEASE KNOW ALL | | | CLEARANCES PER NEC 110.26 SHALL ALSO BE REQUIRED. | | | 110.3, 90.7, | | | FBC 106.1.2 | | | | | | ** FN:BASED ON TANK PROVIDED AND SIZE OF GENERATOR | | | WITH FUEL CONSUMPTION LISTED ON CUT SHEETS, THIS WILL | | | NOT PROVIDE THE 72HRS AS STATED. AS THIS IS AN OPTIONAL | | | STAND-BY SYSTEM, THE TIME IS NOT OF CONCERN HOWEVER | | | RECORD PLANS SHOULD PROVIDE ALL INFORMATION. | | | | | | 3) NOTE: PLEASE SEE PREVIOUS NOTE #6. PLEASE SUBMIT | | | COMPLETED ENERGY CALCULATIONS WHICH MEET THE FBC AND | | | CORRELATE WITH ALL ELECTRICAL DESIGNS FOR LIGHTING | | | FIXTURESETC ON PLANS. | | | PLEASE BE SURE ALL FIXTURES ON PLANS COORDINATE WITH | | | THE INPUT DATA REPORTS FOR ALL INTERIOR AND EXTERIOR | | | LIGHTING. | | | PLEASE SEE SOME OF THE FOLLOWING EXAMPLES WHERE THESE | | | DO NOT CORRELATE. | | | THE INPUT DATA REPORT WILL BE NOTED AS IDR FOR THE REST | | | OF THIS COMMENT. | | | FOR EXAMPLE: PLEASE SEE THE FIRST ITEM ON THE IDR WHICH | | | IS THE LOBBY LIGHTING WHICH INDICATES A 260W FIXTURE | | | WHEREAS NEITHER THE PLANS NOR THE FIXTURE LEGEND HAS | | | ANY 260W FIXTURE. | | | FOR EXAMPLE: PLEASE SEE THE FIXTURE WS4 WHICH IS ON | | | PLANS AND FIXTURE LEGEND HOWEVER THE IDR DOES NOT ANY | | | OF THESE 75W FIXTURES. | | | FOR EXAMPLE: PLEASE SEE THE EXTERIOR LIGHTING FIXTURES | | | WD26 WHICH DO APPEAR TO BE ON THE IDR AND/OR WATTAGE | | | DOES NOT CORRELATE. | | | FOR EXAMPLE: PLEASE SEE THE TOTAL NUMBER OF *EXTERIOR | | | LIGHTING FIXTURES* DO NOT CORRELATE WITH THE IDR.THIS | | | SHOULD INCLUDE ALL LIGHTING FIXTURES EVEN IF THEY ARE | | | THE 2ND FLOOR EXTERIOR LIGHTS. | | | FOR EXAMPLE: THE TOTAL SQ FT AND ASSUMPTIONS REQUIRED | | | FOR SHELL SPACE HAVE NOT AND ARE NOT INCLUDED. | | | | | | THESE ARE A FEW EXAMPLES AND NOT ALL ITEMS. PLEASE | | | CORRELATE ALL REQUIRED INFORMATION AND ALL INFORMATION | | | ON PLANS WITH THAT OF THE IDR, SUMMARY AND TOTALS ON | | | THE METHOD *B* AS SUBMITTED. | | | PLEASE SEE 13-101.1.6, 13-415.2, 13-415.1.B AND ALL | | | SECTIONS AS GIVEN IN FIRST REVIEW; 13-4, 13-101.1, | | | 13-414.2(2)(3)M 13-415.1.ABC.2, 13-415.1.ABC.1.4, | | | 13-415.2.ABC.1.3 ETC. | | | | | | 4) NOTE: PLEASE SEE PREVIOUS NOTE #9 WHICH REQUESTED TO | | | SUBMIT COMPLETED PHOTO-METRICS FOR EGRESS PATHS | | | INDICATING THE MINIMUM LIGHTING LEVELS FOR FLAT EGRESS | | | SURFACES AS WELL AS BOTH STAIR AREAS. PLEASE SEE LS 101 | | | 7.8.1.3, 7.9.2.2. | | | PLEASE ALSO SEE THE FLORIDA ADMINISTRATIVE CODE | | | 61G15-33.004 AS THIS IS REQUIRED. | | | THE RESPONSE ADDRESSED OTHER PARTS OF PREVIOUS NOTE | | | HOWEVER THIS WAS NOT ADDRESSED AND NONE WERE SUBMITTED | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | ** PLEASE KNOW AS NO LIGHTING LEVELS WERE SUBMITTED | | | NONE COULD BE REVIEWED AT THIS TIME. | | | | | | 5) NOTE: PLEASE SEE PREVIOUS NOTE #17 WHICH MENTIONED | | | FOR ALL A/C CU DISCONNECTS TO MEET 110.26. | | | THE RESPONSE MENTIONS THIS WILL BE FIELD VERIFIED. THIS | | | IS CORRECT HOWEVER THE PLANS ARE STILL REQUIRED TO SHOW | | | MINIMUM CODE COMPLIANCE. | | | PLEASE SEE UNIT LAYOUT ON E4.2 AS DISCONNECTS ARE STILL | | | BE SHOWNON TWO WALLS BEHIND UNITS. | | | ** THIS IS AN ITEM WHICH WOULD NORMALLY BE REDLINED IF | | | THIS WAS OF THE *MINOR* COMMENTS HOWEVER AS PLANS ARE | | | COMING BACK FOR OTHER CORRECTIONS PLEASE SHOW *MINIMUM* | | | CODE COMPLIANCE AT THIS TIME. | | | | | | 6) NOTE: PLEASE SEE PREVIOUS NOTE #20 FOR MEANS OF | | | DISCONNECT FOR FEEDERS AT THE MAIN BUILDING FOR THE | | | FEEDERS FROM THE OUTSIDE MAIN. | | | THE RESPONSE GIVES A LONG EXPLANATION WHICH GOES INTO | | | CODES IN CHAPTER 7 WHICH ARE KNOWN TO THIS OFFICE. | | | PLEASE KNOW THIS PROJECT LOCATION AND BUILDING DOES NOT | | | MEET THE EXCEPTION FOR UNDER SINGLE MANAGEMENT AND | | | QUALIFIED PERSONNEL AND DOCUMENTED SAFE DISCONNECTING | | | PRACTICES. | | | PLEASE SEE AS STATED ON PREVIOUS COMMENTS; PLEASE | | | PROVIDE DISCONNECTING MEANS FOR FEEDERS AS REQUIRED PER | | | 225.31-225.39. | | | THE SECTIONS GIVEN IN THE RESPONSE LETTER FOR THE | | | GENERATOR WHICH REFLECTS FEEDERS FROM *OUTDOOR | | | GENERATOR* SETS FOR 700 AND 701 DO NOT APPLY AS THE | | | SYSTEM AS SHOWN ON PLANS IS THAT OF 702. THE SECTION | | | 702.11 IN THE 2005 NEC WAS REVISED TO INCLUDE THE | | | SECTION WHICH WAS PREVIOUSLY IN 700 AND 701 FOR OUTDOOR | | | GENERATORS, HOWEVER WHEN SPEAKING OF 702.11 THIS | | | SECTION REQUIRES THE DISCONNECTING MEANS TO BE * | | | READILY ACCESSIBLE* AND *WITHIN SIGHT*. PLEASE SEE NEC | | | 100 FOR DEFINITIONS OF BOTH. THE GENERATOR IS WITHIN | | | SIGHT(50FT) HOWEVER THE DISCONNECT MEANS DOES NOT | | | MEET READILY ACCESSIBLE BASED ON PLANS AND INFORMATION | | | SUBMITTED. | | | IN EITHER CASE AS STATED ABOVE THE DISCONNECTING MEANS | | | (W/OUT OCP) FOR THE FEEDERS IS STILL REQUIRED. | | | | | | 7) NOTE: PLEASE SEE PREVIOUS NOTE #21 FOR GROUNDING | | | ELECTRODE SYSTEM. RESPONSE MENTIONS TO SEE DETAILS ON | | | 5.1 AND 7.1 HOWEVER EITHER SHEET DOES NOT PROVIDE THE | | | INFORMATION NEEDED. WHERE IS THE GROUNDING ELECTRODE | | | SYSTEM SHOWN FOR THE MAIN SERVICE LOCATION. RISER SHOWS | | | THAT THERE WILL BE ONE, BUT GROUND RODS, HOW MANY, | | | SIZE, WHAT TYPE ETC IS NOT SHOWN | | | MAIN BUILDING DETAIL DOES SHOW TO CONCRETE ENCASED | | | ELECTRODE BUT IT IS ONLY BEING ASSUMED THAT THIS IS THE | | | FOOTER STEEL AS REQUIRED. | | | (DETAIL ON E7.1 MENTIONS THERE WILL BE A GROUND LOOP) | | | PLEASE PROVIDE MORE INFORMATION OR SHOW DETAIL FOR MAIN | | | SERVICE GE-SYSTEM PER 250.50,-250.56 | | | | | | 8) NOTE: PLEASE SEE PREVIOUS NOTE #23 WHICH SPOKE OF | | | THE REQUIRED DEDICATED CIRCUITS FOR ELEVATOR MACHINE | | | ROOMS/PIT HOIST-WAY CIRCUITS. | | | THE RESPONSE MENTIONS THAT CIRCUIT HP-16 WAS ALREADY | | | PROVIDED. THIS IS TRUE, THIS CIRCUIT WAS PROVIDE | | | HOWEVER AS STATED ON PREVIOUS COMMENT, THIS MAY NOT | | | FEED ANY OTHER LOCATIONS EXCEPT THE AREA IN WHICH IS | | | STATED IN THE CODE. | | | PLEASE ALSO SEE THE RESPONSE MENTIONS THAT IT IS THE | | | CONTRACTORS RESPONSIBILITY TO NOT CONNECT ON THE LOAD | | | SIDE OF THE GFI. THE PREVIOUS REVIEW COMMENT DID NOT | | | SAY ANYTHING ABOUT ANY CONNECTIONS TO THE LOAD SIDE OF | | | THE GFI NOT DID THE COMMENT GIVE A SECTION IN THE CODE | | | WHICH STATES THIS. | | | PLEASE SEE THE PLANS. PLEASE SEE SPECIFICALLY SHEET | | | E4.1, DETAIL #2 E4.1 WHICH SHOWS CIRCUIT HP1-16 FEEDING | | | BOTH THE ELEVATOR ROOM GFI RECEPTACLES AND ALSO THE | | | ELEVATOR PIT GFI RECEPTACLES. THESE ARE NOT PERMITTED | | | AND PLEASE ADJUST CIRCUIT(S). | | | PLEASE SEE SPECIFICALLY SHEET E4.1 WHICH SHOWS CIRCUIT | | | HP1-13 FEEDING BOTH THE MAIN ELECTRICAL ROOM LIGHTING | | | ON FIRST FLOOR AS WELL AS THE LIGHTING IN PIT. | | | ONCE AGAIN THIS IS NOT PERMITTED AND REQUIRES DEDICATED | | | CIRCUITS. | | | PLEASE SEE 620.23 AND 620.24. | | | | | | 9) NOTE: PLEASE SEE PREVIOUS NOTE #26. PLEASE PROVIDE | | | METER CAN SIZES ON BUILDING. PLEASE VERIFY THE 600AMP | | | METER CAN AS SHOWN. | | | PLEASE SEE NOTE #26 FROM PREVIOUS REVIEW IS COPIED FOR | | | SAME CLARIFICATION. | | | PLEASE PROVIDE NOTE FOR *FLOATING NEUTRAL KIT REQUIRED | | | * AT THE METERS AT THE BUILDING. 250.6, 250.24 | | | *************************** | | | 26) NOTE: PLEASE INDICATE THE SIZE/AMERAGE OF THE METER | | | CANS ON THE RISER. PLEASE SEE THE METER WHICH IS SHOWN | | | ONE E-4.2 FOR MAIN IS NOT INCLUDED ON RISER DIAGRAM | | | SHEET E-5.1. | | | PLEASE COORDINATE AND ADJUST PLANS AND SHOW SIZES OF | | | EQUIPMENT. | | | FBC 106.1.2, 106.3.5.1.2 | | | ************************ | | | | | | 10) NOTE: PLEASE SEE PREVIOUS NOTE #27. PLEASE SHOW AND | | | INDICATES FEEDERS FROM GUTTER TO METERS, METERS TO | | | MAINS AT THE BUILDING. | | | PLEASE INDICATE | | | ** PREVIOUS REVIEW NOTE ** | | | 27) NOTE: PLEASE INDICATE THE SIZE OF FEEDERS FROM | | | WIRE-WAY TO METERS TO MAINS ON E5.1. | | | 310.16, 215.5, 240.4 | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 11) NOTE: PLEASE SEE PREVIOUS NOTE #28. | | | THE RESPONSE MENTIONS THIS BREAKER IS 1200AMPS JUST | | | LIKE THE SERVICE. THIS IS OK, HOWEVER THE PLANS ARE | | | STILL REQUIRED TO SHOW AND INDICATE THE SIZE OF THE OCP | | | DEVICE AT UNIT. | | | AS THE RESPONSE LETTER IS NOT PART OF THE RECORD SET | | | OF PLANS AND IS NOT PART OF THE DESIGN PLANS THE PLANS | | | ARE REQUIRED TO CHANGE. | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE BE SURE TO INDICATE THE OVER CURRENT PROTECTION | | | ON THE GENERATOR. PLEASE SEE E5.1 AS AT THIS TIME THE | | | CONDUCTORS FROM THE GENERATOR CAN NOT BE VERIFIED PER | | | 445.13, 310.16 AND 240.4. | | | | | | 12) NOTE: PLEASE SEE NOTICE TO FLORIDA STATUTES | | | 553.80(2)(B) HAS BEEN ATTACHED WITH RESPECT TO REPEAT | | | COMMENTS FOR CODE COMPLIANCE. | | | THIS NOTICE STAND FOR ALL TRADES AND IS NOT ONLY FOR | | | ELECTRICAL. | | | PLEASE KNOW ONE SET OF ELECTRICAL AND MECHANICAL PLANS | | | ARE BEING RETAINED BY THIS OFFICE ALONG WITH ONE SET OF | | | ENERGY CALCULATIONS. | | | ** THIS NOTICE TO FS 553.80 IS ONLY A NOTICE GIVEN AT | | | THIS TIME. | | | | | | *** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-11-28 15:36:19 | 11/27/07 | | | | | | ELECTRICAL REVIEW TO COMMENCE ONCE ONE SET OF PLANS | | | BECOME AVAILABLE FROM OTHER TRADES CURRENTLY REVIEWING | | | PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-08 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-06 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2007-08-08 12:29:46 | 2007-08-07 12:29:46 | | | | | | | | | ** DENIED ** | | | | | | | | | 1) NOTE: PLEASE BE SURE THE FOLLOWING RELEVANT CODES AT | | | A MINIMUM ARE STATED ON PLANS FOR MINIMUM DESIGN. THIS | | | IS REQUIRED ON ARCHITECTURAL TITLE/COVER SHEET AS WELL | | | AS ELECTRICAL PLANS. | | | PLEASE SEE NOTE ON ELECTRICAL PLANS WHICH MENTIONS | | | LOCAL CODE PER PALM BEACH COUNTY JURISDICTION. PLEASE | | | KNOW THIS JOB AS APPLIED IS LOCATION IN THE CITY OF | | | WEST PALM BEACH. | | | 2004 FBC W/ 2006 REVISIONS. | | | 2005 NFPA-70 (NEC) | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER TRADES WHICH MAY | | | REQUIRE OTHER CODES. | | | | | | 2) NOTE: PLEASE SEE THAT ONCE THE ADDRESS OF THE | | | PROJECT IS CONFIRMED ALONG WITH TENANT SUITE/UNIT | | | NUMBERS FROM THE ADDRESSING REVIEWER, PLEASE BE SURE TO | | | COMPLETE TITLE BLOCK WITH ALL INFORMATION AS | | | DETERMINED. | | | FLORIDA ADMINISTRATIVE CODE61G1-16.004, 61G15-23.002 | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 3) NOTE: PLEASE SEE THE PERMIT APPLICATION REQUESTS FOR | | | THE PROJECT TO BE DESCRIBED IN DETAIL, HOWEVER THE | | | APPLICATION ONLY STATES *NEW BUILD*? PLEASE SEE THE SQ | | | FT ON PERMIT APPLICATION DOES NOT MATCH WITH THE ENERGY | | | CALCULATIONS ETC. | | | PLEASE COORDINATE AND SEE POSSIBLE COMMENTS FROM OTHER | | | TRADES. | | | | | | 4) NOTE: PLEASE SEE THAT THE LANDSCAPE LIGHTING PLANS | | | ARE REQUIRED TO BE SIGNED, DATED AND SEALED BY THE | | | DESIGNER OF RECORD. PLEASE SEE SHEET 1 OF 1. FLORIDA | | | STATUTES 481.221 | | | PLEASE SEE OTHER LANDSCAPE PLANS WHICH WERE NOT DATED | | | WHEN SIGNED AND SEALED AS REQUIRED PER ABOVE FLORIDA | | | STATUTES. | | | ** THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER TRADES. | | | | | | 5) NOTE: PLEASE SEE PLANS INDICATE A NEW GENERATOR, | | | FUEL TANK AND ATS. PLEASE SUBMIT MANUFACTURES SPECS/CUT | | | SHEETS FOR THESE ITEMS. PLEASE KNOW AS THE PLANS SEEM | | | TO INDICATE A BI-FUEL UNIT, PLEASE OBTAIN THE LISTING | | | AND INFORMATION ON THIS UNIT. IT IS KNOWN TO THIS | | | OFFICE THAT THE GAS COMBUSTION CHAMBER AND ACCESSORIES | | | ARE ADDED TO EQUIPMENT AFTER EQUIPMENT. IT IS ALSO THE | | | UNDERSTANDING OF THIS OFFICE THAT THE EPA CERTIFICATION | | | IS LOST ALONG WITH LISTING FROM THE MANUFACTURE AS THE | | | DIESEL UNITS ARE MADE TO A LISTED STANDARD. PLEASE KNOW | | | IF THESE ITEMS ARE ADDED AS AN AFTER MARKET CONVERSION, | | | THE UNIT WILL BE REQUIRED TO BE RE-LISTED, AND | | | CERTIFICATION FROM EPA WILL BE REQUIRED. | | | PLEASE SUPPLY MORE INFORMATION ON UNIT AND | | | SPECIFICATIONS AS REQUESTED. PLEASE SEE POSSIBLE | | | COMMENTS FROM OTHER TRADES. | | | NEC 110.3, 90.7. | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 6) NOTE: PLEASE SUBMIT CORRECTED AND COMPLETE ENERGY | | | CALCULATIONS WITH COORDINATION WITH THE ELECTRICAL | | | PLANS SUBMITTED. | | | PLEASE SEE THE INPUT DATA REPORT AS THIS DOES NOT | | | CORRELATE WITH PLANS FOR LUMINARIES TYPE, LUMINARIES | | | WATTAGE, THE NUMBER OF LUMINARIES, METHOD OF CONTROLS, | | | AREAS ETC. | | | PLEASE SEE PAGE #2 FOR EXAMPLE OF THE INPUT DATA REPORT | | | WHICH ONLY INDICATES A TOTAL OF TWO LUMINARIES WHEN THE | | | PLANS IN FACT INDICATE A FAR GREAT NUMBER. | | | PLEASE SEE THE ENERGY CALCULATIONS DO NOT INDICATE ANY | | | LIGHTING ENTERED FOR EXTERIOR LIGHTING?? HOW IS THIS | | | POSSIBLE WHEN THE PLANS INDICATE NUMEROUS FIXTURES FOR | | | EXTERIOR LIGHTING? | | | PLEASE SEE 13-4, 13-101.1, 13-414.2(2)(3)M | | | 13-415.1.ABC.2, 13-415.1.ABC.1.4, 13-415.2.ABC.1.3 | | | ETC. | | | PLEASE COORDINATE ALL FIXTURES, CONTROLS, AREAS, | | | WATTAGE AND INFORMATION ON PLANS WITH THE ENERGY | | | CALCULATIONS. | | | PLEASE BE SURE TO UPDATE THE PROJECT ADDRESS | | | INFORMATION ON THE CALCULATIONS COVER SHEET. PLEASE | | | KNOW THAT AT THIS TIME THERE SEVERAL AREAS WHICH NEED | | | TO BE ADDRESSED AND CHANGED AND REVISED CALCULATIONS | | | MAY VERY WELL CONTAIN NEW COMMENTS AS THERE ARE ITEMS | | | NOT YET SUBMITTED FOR REVIEW. | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | SUCH AS MECHANICAL REVIEW WHICH MAY AFFECT ENERGY | | | CALCULATIONS AND METHOD USED. | | | | | | 7) NOTE: PLEASE SEE THAT LIGHTING CONTROLS FOR FBC | | | CHAPTER 13 NEED SOME CLARIFICATION. PLEASE SEE THERE | | | ARE AREAS ON PLANS WHICH DO NOT CONTAIN ANY OVER RIDE | | | DEVICES ON PLANS. PLEASE SEE *COMMON AREAS* FOR EXAMPLE | | | ON SHEET E1.2, WHICH ONLY CONTAIN STANDARD SWITCHES. | | | PLEASE PROVIDE SCHEDULING FOR SYSTEM(S). A BASE TIME ON | | | PLANS SHALL BE INDICATED. | | | PLEASE PROVIDE MAXIMUM TIMES FOR ALL OVER RIDE DEVICES. | | | THIS WOULD INCLUDE TIMERS, OCCUPANCY SENSOR DEVICES | | | ETC. | | | 13-415.1.ABC.1.1, .1.2 AND .1.3. | | | | | | 8) NOTE: PLEASE KNOW AS REQUIRED PER LIFE SAFETY CODE | | | AND THE FIRE MARSHALS OFFICE, THE FIRST FLOOR TENANT | | | SPACES WHICH ARE NOT GOING TO BE BUILT AT THIS TIME | | | WILL STILL REQUIRE SOME TYPE OF NORMAL LIGHTING WITH | | | AUTOMATIC SHUT OFF CONTROLS. | | | THIS CAN BE A MINIMUM OF FIXTURES. | | | PLEASE SEE LS 101 7.8 AND 7.9. BATTERY BACK UP FIXTURES | | | ARE ALREADY SHOWN BUT MAY NOT MEET THE MINIMUM NEEDED | | | FOR MINIMUM LIGHTING LEVELS. | | | | | | 9) NOTE: PLEASE SEE THE PLANS ARE MISSING MINIMUM | | | EGRESS LIGHTING IN MANY AREAS. PLEASE SEE FOR EXAMPLE | | | THE FOYER AREA ON THE FIRST FLOOR WHERE NO BATTERY BACK | | | UP LIGHTING FIXTURES COULD BE LOCATED TO THE PUBLIC | | | RIGHT OF WAY. PLEASE ALSO SEE 2ND FLOOR COMMON ARE | | | CORRIDORS FOR ANOTHER EXAMPLE. | | | PLEASE SUBMIT COMPLETED PHOTO-METRICS FOR EGRESS PATHS | | | INDICATING THE MINIMUM LIGHTING LEVELS FOR FLAT EGRESS | | | SURFACES AS WELL AS BOTH STAIR AREAS. PLEASE SEE LS 101 | | | 7.8.1.3, 7.9.2.2. | | | PLEASE ALSO SEE THE FLORIDA ADMINISTRATIVE CODE | | | 61G15-33.004 AS THIS IS REQUIRED. | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | ** PLEASE KNOW AS NO LIGHTING LEVELS WERE SUBMITTED | | | NONE COULD BE REVIEWED AT THIS TIME. | | | | | | 10) NOTE: PLEASE SEE PLANS ARE MISSING THE MINIMUM | | | LEVELS FOR ADA COMPLIANCE FOR HORNS, STROBES AND | | | HORN/STROBES. | | | PLEASE SEE FBC 11-4.28.1, .2 AND .3(4) FOR MINIMUM | | | LEVELS TO BE PLACED ON PLANS FOR SYMBOL LEGEND FOR FIRE | | | ALARM DEVICES AND OR FA PLANS. | | | PLEASE KNOW THAT EVEN AS THE FIRE ALARM PLANS WILL BE | | | UNDER SEPARATE PERMITS, THE BASE DESIGN ON BASE | | | BUILDING PLANS ARE REQUIRED TO MEET THE MINIMUM DESIGN | | | LEVELS PER THE FBC. | | | | | | 11) NOTE: PLEASE BE SURE TO CORRELATE THE LANDSCAPE | | | LIGHTING PLANS WITH THE ELECTRICAL PLANS FOR FIXTURES, | | | LOADS AND CIRCUITING. LANDSCAPE PLANS DO SHOW LIGHTING | | | AT THIS TIME AND THE INTENT OF INSTALLATION. | | | PLANS ALONG WITH THE ENERGY CALCULATIONS WILL BE | | | REQUIRED TO BE UPDATED. | | | 310.16, 240.4, 408.4 ETC | | | FBC 106.1.2, 106.3.5.1.2 FOR ADDITIONAL INFORMATION | | | REQUIRED ON PLANS. | | | | | | 12) NOTE: PLEASE KNOW THE WIND LOAD ENGINEERING FOR | | | SITE LIGHTING POLES WILL BE NEED FOR REVIEW FROM THIS | | | STRUCTURAL REVIEWER. THIS IS BEING NOTED FOR | | | INFORMATION AT THIS TIME. | | | | | | 13) NOTE: PLEASE SEE THE SITE LIGHTING PLANS INDICATE A | | | TITLE AND A BLOCK FOR *CITY OF WEST PALM BEACH LIGHTING | | | REQUIRED*. PLEASE CLARIFY WHERE THIS INFORMATION IS | | | FOUND AS THIS OFFICE CONTAINS NO SUCH REQUIREMENTS. | | | THERE IS MAXIMUM ALLOWED WATTAGE AND ENERGY USE AS | | | STATED IN THE FLORIDA BUILDING CODE AND CHAPTER 13 BUT | | | WE DO NOT REQUIRE SPECIFICS AS STATED ABOVE. PLEASE | | | CLARIFY. | | | FBC 106.1.2 | | | | | | 14) NOTE: PLEASE GIVE CONSIDERATION FOR THE TYPE OF | | | DEVICES BEING CHOSEN FOR NOT ONLY THE ELECTRICAL ROOM | | | BUT FOR BOTH ELECTRICAL ROOMS AND ELEVATOR MACHINE ROOM | | | LIGHTS. | | | PLEASE SEE 110.26E FOR THE TYPE OF DEVICE. | | | | | | 15) NOTE: PLEASE SEE THE LIGHTING PLANS FOR SECOND AND | | | FIRST FLOORS CONTAINS A *KEYED NOTE* #2 WHICH MENTIONS | | | THE CONNECTION OF LIGHTING AHEAD OF SWITCHES AND | | | OCCUPANCY TYPE DEVICES. | | | PLEASE SEE FBC 1006.1.2 AND LS 101 7.8.1.2.2 AUTOMATIC, | | | MOTION SENSOR?TYPE LIGHTING SWITCHES SHALL BE PERMITTED | | | WITHIN THE MEANS OF EGRESS, PROVIDED THAT THE SWITCH | | | CONTROLLERS ARE EQUIPPED FOR FAIL-SAFE OPERATION, THE | | | ILLUMINATION TIMERS ARE SET FOR A MINIMUM 15-MINUTE | | | DURATION, AND THE MOTION SENSOR IS ACTIVATED BY ANY | | | OCCUPANT MOVEMENT IN THE AREA SERVED BY THE LIGHTING | | | UNITS. | | | PLEASE SEE 7.8 AND 7.9 AS THE FAILURE OF A SINGLE | | | CONTROL DEVICE SHALL NOT LEAVE ANY ONE AREA IN TOTAL | | | DARKNESS. | | | | | | 16) NOTE: PLEASE KNOW AS INFORMATION, THE LOW VOLTAGE | | | AS SHOWN ON PLANS WILL BE REQUIRED TO BE UNDER A | | | SEPARATE PERMIT. THESE PLANS MAY BE REFERENCED FOR THE | | | WORK AS APPLIED AND SHOWN. | | | ** INFORMATION ONLY AT THIS TIME AND NO CHANGES ARE | | | NEEDED TO PLANS. | | | | | | 17) NOTE: PLEASE SEE 110.26 OF THE NEC AS THE MINIMUM | | | WIDTHS FOR DISCONNECTS AT THE CONDENSING UNITS IS NOT | | | MET BY THE PLANS AND THE SCALE AS NOTED AND SHOWN. | | | PLEASE SEE E4.2 FOR NORTH AND SOUTH YARDS. | | | | | | 18) NOTE: PLEASE BE SURE PANEL SCHEDULES ARE SPECIFIC | | | TO ALL ROOMS AND AREAS IN WHICH THEY FEED. PLEASE SEE | | | THE USE OF *GENERAL RECEPTACLES AND GENERAL LIGHTS* | | | NEEDS TO BE SPECIFIC. PLEASE SEE THIS COMMENT IS FOR | | | ALL PANEL SCHEDULE WITH GENERAL DESIGNATIONS. PLEASE | | | KNOW THE DESIGNATION MAY BE THE NUMERICAL DESIGNATION | | | AS NOTED ON PLANS. | | | PLEASE SEE 408.4 AND COMMENTARY AS EXTRACTED FROM THE | | | NEC BELOW. | | | *SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | | PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | | SECTION.* | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | 19) NOTE: PLEASE CORRELATE RISER DIAGRAM WITH THE PANEL | | | SCHEDULES FOR EQUIPMENT AS SUBMITTED. | | | PLEASE SEE RISER SHEET E5.1 FOR EXAMPLE AS SHEET | | | INDICATES A MAIN CIRCUIT BREAKER PANEL AND RISER DOES | | | NOT. | | | FBC 106.1.2 | | | | | | 20) NOTE: PLEASE SEE MISSING MEANS OF DISCONNECTS AT | | | THE MAIN BUILDING AS THIS IS CONSIDERED A DETACHED | | | STRUCTURE AND WOULD NEED TO COMPLY WITH 225.31-225.39. | | | PLEASE LABEL ALL EQUIPMENT FOR MAINS AT THIS BUILDING. | | | THE SERVICE MAIN OUTSIDE CAN NOT BE CONSIDERED THIS | | | MAIN AS IT IS NOT PART OF THE BUILDING. | | | PLEASE ADJUST AND PLACE NOTES ON PLANS FOR SIGNS OF THE | | | BUILDING MAINS AND LOCATION FOR SERVICE MAIN. | | | | | | 21) NOTE: PLEASE CLARIFY THE LOCATION OF THE GROUNDING | | | ELECTRODE SYSTEM AS SHOWN. PLEASE SEE THE SYSTEM AS | | | SHOWN APPEARS TO BE AT THE MAIN BUILDING WHICH IS | | | REQUIRED AS IT IS A DETACHED STRUCTURE PER 250.32, | | | HOWEVER PLEASE CLARIFY SYSTEM AT THE SERVICE MAIN | | | LOCATION PER 250.50. | | | | | | | | | 22) NOTE: PLEASE CLARIFY FIRE SPRINKLER BOND PER | | | 250.104. THE DETAIL ON 7.1 INDICATES WATER PIPE, | | | HOWEVER NOT CLEAR AS THIS APPEARS TO BE THE ONE FOR THE | | | BUILDING. | | | | | | 23) NOTE: PLEASE SEE 620.24C,AS THE ELEVATOR ROOM | | | AND PIT LIGHTS/RECEPTACLES ARE REQUIRED TO BE ON A | | | DEDICATED BRANCH CIRCUITS. PLEASE SEE SHEET FOR | | | LIGHTING AND ELEVATOR ROOMS ON E4.1 AS SOME OF THESE | | | CIRCUITS AS SHOWN ACTUALLY FEED OTHER AREAS. (EXAMPLE | | | ELECTRICAL ROOM). | | | | | | 24) NOTE: PLEASE PROVIDE INFORMATION ON PLANS FOR OVER | | | CURRENT PROTECTION FOR ELEVATOR CAB LIGHTS. PLEASE SEE | | | THE DETAIL ON E4.1 SHOWS THE DISCONNECT AS REQUIRED | | | HOWEVER DOES NOT INDICATE THE OVER CURRENT PROTECTION | | | WHICH IS REQUIRED TO BE THE SAME ROOM PER 620.22A. | | | | | | 25) NOTE: PLEASE CLARIFY THE *TELCO* ROOM THAT THIS IS | | | OR IS NOT AN IT ROOM BY DEFINITIONS. | | | IF THIS IS GOING TO BE AN IT ROOM OR IF ANY OTHER | | | LOCATION IS GOING TO BE USED FOR THIS SAME REASON, | | | PLEASE SEE NEC 645. | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 26) NOTE: PLEASE INDICATE THE SIZE/AMERAGE OF THE METER | | | CANS ON THE RISER. PLEASE SEE THE METER WHICH IS SHOWN | | | ONE E-4.2 FOR MAIN IS NOT INCLUDED ON RISER DIAGRAM | | | SHEET E-5.1. | | | PLEASE COORDINATE AND ADJUST PLANS AND SHOW SIZES OF | | | EQUIPMENT. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 27) NOTE: PLEASE INDICATE THE SIZE OF FEEDERS FROM | | | WIRE-WAY TO METERS TO MAINS ON E5.1. | | | 310.16, 215.5, 240.4 | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 28) NOTE: PLEASE BE SURE TO INDICATE THE OVER CURRENT | | | PROTECTION ON THE GENERATOR. PLEASE SEE E5.1 AS AT THIS | | | TIME THE CONDUCTORS FROM THE GENERATOR CAN NOT BE | | | VERIFIED PER 445.13, 310.16 AND 240.4. | | | | | | 29) NOTE: PLEASE CLARIFY THE DIMENSIONS ON THE WIRE-WAY | | | AS THIS IS CURRENTLY SHOWN AS 8X8. PLEASE PROVIDE | | | CALCULATIONS BASED ON THE CONDUCTORS AND RADIUS/BENDING | | | SPACE ETC. | | | PLEASE SEE 376.22 | | | | | | 30) NOTE: PLEASE SEE RISER SHEET E5.1 STATES THE | | | AVAILABLE FAULT CURRENT HAS BEEN ASSUMED AND ALSO | | | CONTAINS AN ADDITIONAL NOTE ON RISER WHICH MENTIONS TO | | | BE VERIFIED BY CONTRACTOR. | | | CONTACT SHOULD BE MADE TO THE FPL SERVICE PLANNER AT | | | THIS TIME FOR THE CORRECT AVAILABLE FAULT CURRENT AND | | | PLACE THE MINIMUM RATINGS ON THE PLANS AT THIS TIME. | | | PLEASE SEE 110.9, 110.10 | | | PLEASE KNOW THIS IS REQUIRED ON THE DESIGN | | | PROFESSIONALS PLANS AT THIS TIME. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-08-07 21:28:15 | 2007-08-07 21:28:15 | | | | | | REVIEW COMPLETED. REVIEW NOTES TO FOLLOW ON 8/8/07 | | 2007-08-07 07:12:43 | 2007-08-07 07:12:43 | | | | | | 1-SET IN ELEC FOR REVIEW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-11-21 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-11-21 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2007-11-21 14:32:57 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | | | | COUND NOT FIND IN YOUR PACKAGE. PLEASE MAKE A SEPARATE | | | PACKAGE FOR ENGINEERING REVIEW, SO, I GET IT WITHOUT | | | LOST. | | | | | | 2. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, | | | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST | | | FLOOR ELEVATION, PLEASE SHOW IN YOUR STORM WATER CALS | | | THAT HOW DID YOU DETERMINE THE FIRST FLOOR ELEVATION? | | | FIRST FLOOR ELEVATION MUST BE HIGHER THAN MAXIMUM CROWN | | | OF THE ROAD BY ATLEAST 1 FOOT. | | | 3. PLEASE SHOW DETAIL OF THE CONTROL STRUCTURESWITH | | | ELEVATIONS, NOTCHES, BLEEDING ELEVATION, ETC ON | | | DRAWINGS,PLEASE PROVIDE CALCULATION FOR EXFILTRATION | | | TRENCHES IN WATER QUALITY CALS.PLEASE SHOW DRY | | | DETENTION/WET DETENTION AREAS IN STORM WATER CALS. | | | AFTER CONTROL STRUCTURE WHERE DOES STORM WATER GOES?? | | | 4. PLEASE RESUBMIT A COPY OF SFWMD PERMIT,, & PROVIDE | | | STORM WATER QUALITY CALCULATIONS. PLEASE RESUBMIT | | | GEO-TECH REPORT WITH STORM WATER CALS. ALSOSTORM | | | WATER CALS MUST BE APPROVED FROM 100045TH STREET | | | ENGINEERING SERVICES. | | | 5. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-09-11 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-09-11 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2007-09-11 10:24:56 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON CIVIL DRAWING THE SITE PLAN SHOWING | | | STREETS/ROADS AROUND THE SITE WITH NORTH ARROW. | | | 3.PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR | | | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP | | | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FROM | | | 1000, 45 STREET FOR ALL THESE CITY STANDARDS NOTES. | | | PHONE# 494-1040 | | | 4. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 5. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, | | | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST | | | FLOOR ELEVATION, PLEASE SHOW IN YOUR STORM WATER CALS | | | THAT HOW DID YOU DETERMINE THE FIRST FLOOR | | | ELEVATION??. | | | 6. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE | | | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL | | | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, | | | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE | | | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED | | | IN STORM WATER QUALITY CALCULATIONS. | | | 7. HOW DO YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM | | | WATER PIPES FROM ALL OTHER STORM WATER PIPES. PLEASE | | | SHOW DETAIL OF THE CONTROL STRUCTURESWITH | | | ELEVATIONS, NOTCHES, BLEEDING ELEVATION, ETC ON | | | DRAWINGS,PLEASE SHOW CALCULATION FOR EXFILTRATION | | | TRENCHES IN WATER QUALITY CALS.PLEASE SHOW DRY | | | DETENTION/WET DETENTION AREAS IN STORM WATER CALS. | | | AFTER CONTROL STRUCTURE WHERE DOES STORM WATER GOES?? | | | 8. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN. | | | 9. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, &STORM | | | WATER QUALITY CALCULATIONS. PLEASE RESUBMIT GEO-TECH | | | REPORT WITH STORM WATER CALS.STORM WATER CALS MUST BE | | | APPROVED FROM 100045TH STREET ENGINEERING SERVICES. | | | 10. POLLUTION PREVENTION:HEIGHT OF THE SILTFENCE | | | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & | | | PARTICLES. | | | 11. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-19 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-19 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2007-12-19 10:10:13 | *****PROVISO**** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEETS SP-2, LS-1, LS-2, A-2.4, | | | A-5.1, FA1.1, FA1.2, FP0.1, FP1.1, FP1.2, AND FP7.1 | | | WERE STAMPED, INITIALED, AND DATED.HOWEVER, PLAN | | | SHEETS E1.1 & E1.2 STILL NEED TO BE FIRE-STAMPED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-12 |
Time |
21:51 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-12 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2007-10-15 11:15:06 | *****DENIED***** | | | | | | 01.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 02.THE ADDRESS OF THE PROJECT SITE SHALL BE IN THE | | | TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 03.THE RELOCATED FIRE HYDRANTS SHALL BE INSTALLED, | | | COMPLETED, AND IN SERVICE PRIOR TO CONSTRUCTION WORK, | | | | | | 04.LANDSCAPING SHALL NOT INTERFERE OR HINDER ACCESS | | | TO FIRE PROTECTION EQUIPMENT AND DEVICES. | | | | | | 05.NFPA 101, LIFE SAFETY CODE, 2003 EDITION AND THE | | | FLORIDA FIRE PREVENTION CODE 2004 SHALL BE REFERENCED. | | | THESE REFERENCES ARE INCORRECTLY SHOWN AS ONE LISTED ON | | | THE LIFE SAFETY SHEETS. | | | | | | 06.ON THE LIFE SAFETY SHEETS (LS-1 & LS-2), CLASS "D" | | | FINISHES FOR ROOMS AND ENCLOSED SPACES IS LISTED.AS | | | PER 38.3.3.2.2 , CLASS A, B, OR C SHALL BE LISTED IN | | | THESE OTHER AREAS. | | | | | | 07.ON SHEET LS-2, REFERENCE IS INCORRECTLY MADE TO | | | 1ST FLOOR - LIFE SAFETY. | | | | | | 08.ON SHEET LS-2, PLEASE EXPLAIN RATIONALE FOR ONLY | | | SHOWING TRAVEL DISTANCE TO ONLY 1 OF THE 2 STAIRWELLS. | | | | | | 09.SPECIFY THE INTERIOR FLOOR FINISH FOR THE EXIT | | | ENCLOSURES IN TERMS OF CLASS I OR CLASS II. | | | | | | 10.PLEASE PROVIDE FLAME SPREAD DETAILS ON THE FABRIC | | | OF THE PARKING CANOPY. | | | | | | 11.HOW WILL THE INSTALLATION OF THE CARD ACCESS | | | SYSTEM (CARD READERS) IMPACT ANY EXITING FROM THE EXIT | | | STAIRWAYS?PLEASE BE ADVISED THAT SEPARATE PLANS AND | | | PERMIT WILL BE REQUIRED FOR CARD ACCESS SYSTEM. | | | | | | 12.ON THE APPROPIATE EXTERIOR ELEVATION, POST THE | | | NUMERICAL ADDRESS ON THE BUILDING TO BE VISIBLE FROM | | | IBIS BOULEVARD.AS PER WEST PALM BEACH CODE, THE | | | NUMBERS SHALL BE NO LESS THAN 6" IN HEIGHT AND NO LESS | | | THAN 1" IN WIDTH. | | | | | | 13.ON THE APPROPIATE EXTERIOR ELEVATION, SHOW THE | | | LOCATION OF THE KNOX BOX.FOR APPLICATIONS, CONTACT | | | WEST PALM BEACH FIRE PREVENTION BUREAU AT | | | 561-804-4724. | | | | | | 14.PROVIDE PRESCRIPTIVE STRENGHTS FOR THE STAIR | | | HANDRAILS/GUARD RAILS. | | | | | | 15.SHOW/VERIFY THAT THE HEADROOM ON STAIRS SHALL NOT | | | BE LESS THAN 80" AND SHALL BE MEASURED VERTICALLY ABOVE | | | A PLANE PARELLEL TO AND TANGENT WITH THE MOST FORWARD | | | PROJECTION OF THE STAIR DETAIL. | | | | | | 16.NO TAMPER SWITCH (TS) AND FLOW SWITCH (FS) SHOWN | | | ON THE FA1.1 SHEET. | | | | | | 17.FIRE DEPARTMENT CONNECTION (FDC) SHALL BE EQUIPPED | | | WITH KNOX LOCKING CAPS.FOR APPLICATIONS, CONTACT | | | WEST PALM BEACH FIRE PREVENTION BUREAU AT | | | 561-804-4724. | | | | | | 18.ELECTRONIC SWITCHES, CHAIN AND LOCK SHALL BE | | | REQUIRED ON THE FIRE LINE BACKFLOW DEVICE. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH COMMENT WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-05 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-05 |
Time |
08:35 |
Sent To |
|
|
| Notes |
| 2007-11-15 14:51:37 | TO "COMM" BD#38 | | 2007-11-05 08:36:15 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-12 |
Time |
21:52 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-13 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2007-08-07 18:34:17 | MOVED TO COMM BOARD #36 | | 2007-07-24 11:11:14 | TO "COMM" BD#37 | | 2007-07-13 08:59:21 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-28 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-26 |
Time |
17:55 |
Sent To |
|
|
| Notes |
| 2007-11-28 16:34:45 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 AMENDMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. THE REVISED NOTE #13 INDICATES AN AUDIBLE AND | | | VISIBLE SIGNAL WILL BE LOCATED AT THE RESPECTIVE | | | THERMOSTATS. IS THIS IN ADDITION TO THE GENERAL ALARM | | | SIGNAL AS INDICATED BY NOTE 9(D) ON PG E5.2? ALSO, | | | PLEASE COORDINATE THIS NOTE WITH NOTE #17 ON PG FA 1.2, | | | WHICHINDICATES A VISIBLE AND AUDIBLE ALARM WILL BE | | | SENT TO THE FACP. THIS IS LOCATED AT THE 1ST FLOOR | | | LOBBY AND DOES NOT APPEAR TO BE A CONSTANTLY ATTENDED | | | LOCATION. | | | | | | 2. OK | | | | | | 3. M1.1: THERE IS STILL ONE 12X8 EXHAUST DUCT | | | PENETRATION (ASSOCIATED WITH KEY NOTE #2, AS STATED IN | | | PREVIOUS REVIEW) WHICH IS NOT SHOWN AS BEING PROTECTED | | | BY A FIRE DAMPER. SHOW COMPLIANCE WITH FBC,M 607.6 AND | | | 607.8. | | | | | | 4. OK | | | | | | 5. THE DESIGN INTENT IS STILL UNCLEAR. ON M7.2, DETAIL | | | 9 SHOWS THE PIPES ENTERING A FIRE RATED CHASE. ON M7.1, | | | DETAIL 9 SHOWS A THROUGH-PENETRATION FIRESTOP SYSTEM | | | FOR CONCRETE, INDICATING THIS IS A FLOOR/CEILING | | | PENETRATION. A FLOOR/CEILING THROUGH-PENETRATION SYSTEM | | | IS NOT NEEDED IF THE PIPE IS IN A FIRE RATED CHASE. | | | ALSO, THE SYSTEM SPECIFIED IN THE DETAIL IS NOT | | | APPLICABLE TO THIS LOCATION FOR THE FOLLOWING REASONS: | | | A) IT ONLY ALLOWS FOR ONE PIPE PER HOLE. | | | B) IT IS ONLY LISTED FOR STEEL PIPE. COPPER IS NOT PART | | | OF ITS LISTING. | | | C) IF THIS IS NOT FOR THE FLOOR/CEILING, BUT FOR WHERE | | | THE PIPES LEAVE THE FIRE RATED CHASE, IT WILL NOT WORK | | | BECAUSE IT IS ONLY LISTED FOR USE IN CONCRETE, NOT A | | | FRAMED WALL OR SHAFT ASSEMBLY. | | | ALSO, THERE IS NO FIRE RATED CHASE SHOWN ON | | | ARCHITECTURAL FLOOR PLANS AT THESE LOCATIONS, ONLY | | | PARTITIONS TO GO 6 INCHES ABOVE THE CEILING ACCORDING | | | TO THE WALL LEGEND ON THE A PAGES. THERE IS NO LISTED | | | ASSEMBLY FOR A FIRE RATED CHASE IN THE ARCHITECTURAL | | | DETAILS. PLEASE CLARIFY THE INTENT AND DEMONSTRATE | | | COMPLIANCE WITH FBC 712.4. | | | | | | 6. OK | | | | | | 7. OK | | | | | | 8. THE ?ASSEMBLY AND DIMENSIONAL INFORMATION? PACKAGE | | | SUBMITTED FOR FIRE DAMPERS DOES NOT INCLUDE THE | | | MANUFACTURER?S INSTALLATION INSTRUCTIONS. DETAIL 7 ON | | | M7.1 DOES NOT CORRESPOND WITH RUSKIN INSTALLATION | | | INSTRUCTIONS. OPTIONS: | | | A) REMOVE THE CURRENT DETAIL FROM THE PLANS. PROVIDE A | | | NOTE ON PLANS DEFERRING TO MANUFACTURER?S INSTALLATION | | | INSTRUCTIONS. PROVIDE MANUFACTURER?S INSTALLATION | | | INSTRUCTIONS IN THE SUBMITTAL PACKAGE. | | | B) INCLUDE THE MANUFACTURER?S INSTALLATION INSTRUCTION | | | ON PLANS (IF ALLOWED BY MANUFACTURER, THIS IS NOT A | | | RECOMMENDATION TO VIOLATE ANY COPYRIGHT.). | | | SHOW COMPLIANCE WITH FBC, M 607.2. | | | | | | 9. THE PRESCRIPTIVE FASTENING METHOD LISTED IN FBC, M | | | 301.13.1 IS ONLY APPLICABLE FOR GROUP R-3 OCCUPANCIES. | | | IT IS NOT APPLICABLE TO THIS PROJECT. IN ANY OTHER | | | OCCUPANCY, ENGINEERING IS REQUIRED BASED ON THE WIND | | | SPEED AND WIND LOAD CALCULATIONS IN ACCORDANCE WITH FBC | | | CH.16. OPTIONS: | | | A) PROVIDE WIND LOAD CALCULATIONS FOR OUTDOOR EQUIPMENT | | | WITH FASTENER DETAILS FOR BUILDING PLAN REVIEW. NOTE: | | | DETAIL 3 ON M7.2 SHOWS INBED OR EXPANSION ANCHOR BOLTS | | | TO BE USED ON CONDENSERS BUT KEY NOTES CALL FOR STRAPS | | | AND TAPCONS. | | | B) CHECK WITH EQUIPMENT MANUFACTURER. MANY | | | MANUFACTURERS HAVE THEIR INSTALLATION INSTRUCTIONS | | | TESTED AND CERTIFIED TO MEET WIND LOADS ALREADY. IF | | | THIS IS THE CASE, MANUFACTURER?S INSTRUCTIONS MAY BE | | | USED. A DETAIL MAY BE PROVIDED WHICH CORRESPONDS WITH | | | THOSE INSTRUCTIONS AND A NOTE WHICH DEFERS TO | | | INSTRUCTIONS MAY BE USED. IF THIS METHOD IS USED, | | | PROVIDE DOCUMENTATION WHICH VERIFIES THAT THE | | | MANUFACTURER?S INSTRUCTIONS HAVE BEEN TESTED AND MEET | | | WIND LOADS FOR THIS AREA. | | | | | | 10. OK | | | | | | 11. ENERGY CALCULATIONS: METHOD B HAS BEEN SUBMITTED. | | | HOWEVER, IT APPEARS THAT ONLY THE SPACES BEING | | | BUILT-OUT ARE INCLUDED IN THE CALCULATIONS. AS STATED | | | IN FBC 13-101.1.6, ?ALL ASSUMPTIONS MADE ABOUT FEATURES | | | NOT INSTALLED UNTIL LATER THAT ARE NOT ON THE BUILDING | | | PLANS SHALL BE LISTED AND APPENDED TO THE COMPLIANCE | | | FORM SUBMITTED TO THE BUILDING DEPARTMENT.? NO | | | ASSUMPTIONS ABOUT FEATURES TO BE INSTALLED IN THE | | | UNFINISHED AREA COULD BE FOUND APPENDED TO THE | | | CALCULATIONS. ALSO, THE PROJECT SUMMARY PAGE INDICATES | | | THAT ONLY THE FINISHED AREAS WERE COUNTED IN THE | | | CALCULATIONS. COOLING LOAD CALCULATIONS, A/C EQUIPMENT | | | AND LIGHTING ASSUMPTIONS SHALL BE PROVIDED WITH THE | | | COMPLIANCE FORM FOR ALL UNFINISHED AREAS OF THE | | | BUILDING AND BE INCLUDED IN THE CALCULATIONS IN | | | ACCORDANCE WITH THIS SECTION. ENERGY CALCULATIONS CAN | | | NOT BE REVIEWED AT THIS TIME. | | | | | | 12. OK | | | | | | 13. OK | | | | | | 14. RESPONSE INDICATES THAT THE GENERATOR IS NOT | | | RELATED TO THE MECHANICAL DISCIPLINE. PLEASE SEE FBC, M | | | 915.1, WHICH STATES ?THE INSTALLATION OF LIQUID-FUELED | | | STATIONARY INTERNAL COMBUSTION ENGINES AND GAS | | | TURBINES, INCLUDING FUEL STORAGE AND PIPING, SHALL MEET | | | THE REQUIREMENTS OF NFPA 37.? THIS CLEARLY MAKES DIESEL | | | POWERED GENERATORS AND THEIR FUEL STORAGE SYSTEMS | | | SUBJECT TO THE MECHANICAL CODE. THE MECHANICAL CODE | | | REFERENCES NFPA 37, WHICH IS THE STANDARD BY WHICH THE | | | GENERATOR INSTALLATION AND ITS FUEL STORAGE SYSTEM WILL | | | BE REVIEWED BY THE MECHANICAL REVIEWER. NO INFORMATION | | | HAS BEEN PROVIDED REGARDING DIESEL FUEL STORAGE FOR | | | THIS GENERATOR. ALSO, IF THE DIESEL TANK EXCEEDS 550 | | | GALLONS; THE TANK, ITS INSTALLATION METHOD AND LOCATION | | | MUST BE FIRST APPROVED BY PALM BEACH COUNTY DERM BEFORE | | | SUBMITTAL TO THIS AHJ FOR PERMIT. CONTACT INFORMATION | | | FOR PBC DERM WAS PROVIDED TO THE DESIGN TEAM DURING OUR | | | MEETING IN THIS OFFICE. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-08 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-07 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2007-08-08 18:20:10 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 AMENDMENTS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. M0.2 MECHANICAL EQUIPMENT NOTE #13: DUCT SMOKE | | | DETECTORS SHALL BE CONNECTED TO THE FIRE ALARM SYSTEM | | | PER FBC,M 606.4.1. EITHER A SUPERVISORY SIGNAL AT A | | | CONSTANTLY ATTENDED LOCATION OR ACTIVATION OF THE | | | BUILDING'S ALARM NOTIFICATION DEVICES IS ACCEPTABBLE | | | UNDER THIS CODE. HOWEVER, THE DESIGNER SHOULD CHECK | | | WITH THE WEST PALM BEACH FIRE PREVENTION BUREAU (FIRE | | | MARSHAL'S OFFICE) TO DETERMINE THEIR REQUIREMENTS FOR | | | NOTIFICATION UPON ACTIVATION OF THE DETECTORS. | | | | | | 2. M0.3: PROVIDE INFORMATION FROM EQUIPMENT | | | MANUFACTURER SHOWING REQUIRED CLEARANCES OF OUTDOOR | | | EQUIPMENT FOR SERVICE, MAINTENANCE AND REQUIRED AIRFLOW | | | FOR EFFICIENT OPERATION. FBC 106.1.2 | | | | | | 3. M1.1: KEYED NOTES 2 AND 4, ONLY TWO OF THE FIVE 2ND | | | FLOOR DUCT PENETRATIONS SHOW FIRE DAMPERS. FIRE DAMPERS | | | ARE REQUIRED AT ALL DUCT PENETRATIONS OF 2ND FLOOR SLAB | | | PER FBC,M 607.6. THE SPECIFIC LOCATION OF EACH FIRE | | | DAMPER SHALL BE SHOWN AND PROPERLY IDENTIFIED ON PLANS | | | BY THE DESIGNER. FBC,M 607.8 | | | | | | 4. M1.1: REFRIGERANT LINES THROUGH 1ST FLOOR SLAB | | | APPEAR TO PASS THROUGH STRUCTURAL FOOTERS IN TWO | | | LOCATIONS. PROVIDE DETAIL SHOWING SIZE AND NUMBER OF | | | SLEEVES GOING THROUGH THE FOOTERS FOR STRUCTURAL | | | REVIEW. FBC 106.1.2 | | | | | | 5. M1.2: REFRIGERANT LINES FROM 1ST FLOOR ARE SHOWN IN | | | 2 REFIRGERANT CHASES. THE CHASES ARE NOT SHOWN AS FIRE | | | RATED ON ARCHITECTURAL PLANS. THESE PENETRATIONS SHALL | | | BE PROTECTED IN A FIRE RESISTANCE RATED ASSEMBLY PER | | | FBC 712.4.1.1 OR PROTECTED BY AN APPROVED THROUGH | | | PENETRATION FIRESTOP SYSTEM PER FBC 712.4.1.2. PROVIDE | | | DETAIL AND TYPE OF ASSEMBLY TO BE USED. | | | | | | 6.PROVIDE SUBMITTALS/INSTRUCTIONS FOR TITUS BYPASS | | | TERMINALS. | | | | | | 7. M1.2: KEY NOTE #9, THE 12X12 DUCT FROM 1ST FLOOR TO | | | ROOF NEAR 2AHU-10 APPEARS TO PASS THROUGH THE 18X12 | | | RETURN DUCT. THESE DUCTS DO NOT LOOK LIKE THEY ARE | | | INTENDED TO BE CONNECTED, BUT THAT'S HOW THEY APPEAR ON | | | FLOOR PLAN. PLEASE CLARIFY. | | | | | | 8. M7.1 DETAIL 7: FIRE DAMPERS LOCATED WITHIN AIR | | | DISTRIBUTION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE | | | WITH THE REQUIREMENTS OF THIS SECTION, AND THE | | | MANUFACTURER?S INSTALLATION INSTRUCTIONS AND LISTING | | | PER FBC,M 607.2. IF THIS DETAIL IS NOT FROM THE | | | MANUFACTURER, IT IS NOT ACCEPTABLE AND THE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS MUST BE | | | PROVIDED. | | | | | | 9. M7.2 DETAIL 3: SHOW CONDENSING UNIT ATTACHMENT TO BE | | | DESIGNED FOR THE 140 MPH WIND ZONE PER FBC,M 301.13 AND | | | FBC CH.16 | | | | | | 10. ENERGY CALCULATIONS: PROJECT SUMMARY INDICATES MAX | | | TONNAGE AT 3.4. THE LARGEST SYSTEM SHOWN ON PLANS IS 5 | | | TONS. ALSO, THE OWNER'S NAME AND THE ADDRESS OF THE | | | PROJECT ARE MISSING. PLEASE CORRECT. | | | | | | 11. ENERGY CALCULATIONS: FORM 400A HAS BEEN USED FOR | | | THIS BUILDING. HOWEVER, EITHER METHOD B OR C SHALL BE | | | USED. PLEASE SEE THE FOLLOWING REQUIREMENTS FOR ENERGY | | | CALCULATIONS FOR SHELL BUILDINGS: | | | "NONRESIDENTIAL BUILDINGS THAT ARE PERMITTED PRIOR TO | | | DESIGN COMPLETION OR WHICH WILL BE FINISHED IN SECTIONS | | | AT A TIME AFTER CONSTRUCTION OF THE SHELL SHALL COMPLY | | | WITH EITHER METHOD B OR C OF SUBCHAPTER 13-4 OF THE | | | CODE PRIOR TO GRANTING OF A PERMIT TO BUILD. ALL | | | ASSUMPTIONS MADE ABOUT FEATURES NOT INSTALLED UNTIL | | | LATER THAT ARE NOT ON THE BUILDING PLANS SHALL BE | | | LISTED AND APPENDED TO THE COMPLIANCE FORM SUBMITTED TO | | | THE BUILDING DEPARTMENT. UNLESS THE BUILDING IS | | | COMPLETED AS PER ALL ASSUMPTIONS MADE IN THE ORIGINAL | | | CODE COMPLIANCE SUBMITTAL, A REVISED CODE SUBMITTAL(S) | | | USING METHODS A, B OR C SHALL BE SUBMITTED WHEN | | | COMPLETION OF THE BUILDING (OR PART OF THE BUILDING) IS | | | PERMITTED." FBC 13-101.1.6 | | | | | | 12. PROVIDE AN AIR BALANCE SCHEDULE FOR THE SPACES | | | BEING CONDITIONED TO ASSURE THAT THE BUILDING IS | | | PRESSURIZED WITH RESPECT TO THE OUTDOORS. FBC | | | 13-409.1.ABC.2 | | | | | | 13. PROVIDE SHUTOFF DAMPER CONTROLS THAT WILL | | | AUTOMATICALLY SHUT WHEN SYSTEMS OR SPACES SERVED ARE | | | NOT IN USE. FBC 13-409.1.ABC.3.3 | | | | | | 14. PROVIDE ALL RELEVANT SUBMITTAL DATA FOR THE | | | PROPOSED GENERATOR, INCLUDING INFORMATION ON FUEL | | | STORAGE TANK TO BE USED. | | | NOTE: GENERATORS ARE TO BE INSTALLED IN CONPLIANCE WITH | | | NFPA 37-02. FUEL GAS PERMIT AND PBC DERM APPROVAL MAY | | | BE REQUIRED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-10 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-10 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-10 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2007-12-10 17:01:56 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: THE COMMENT NUMBER SHALL | | | REMAIN THE SAME TO AVOID CONFUSION. | | | | | | 1.OK | | | | | | 2. SHTS 1 THRU 3 OF 3 & 1 THRU 7 OF 7. THE CERTIFICATE | | | OF AUTHORIZATION NUMBER, (FIRM LICENSE NUMBER),IS | | | REQUIRED IN THE TITLE BLOCK OF EACH SHEET AS WELL AS | | | THE DATED SEAL, SIGNATURE, AND PRINTED NAME OF THE | | | PERSON SEALING THE DOCUMENT. FAC 61G1-16.003, | | | 61G1-16.004(2)(6) AND FS 481.219, 481.2055.--IT | | | APPEARS THAT THE PLANS HAVE BEEN SIGNED WITH A | | | INITIALS, NOT A SIGNATURE. IF INDEED THIS IS THE LEGAL | | | SIGNATURE OF THE ENGINEER, THEN A SIGNED, SEALED, | | | LEGALLY NOTORIZED LETTER INDICATING THE LEGAL ADDRESS | | | OF THE LANDSCAPE ARCHITECT SHALL BE SUBMITTED FOR OUR | | | FILES. | | | ****RESPONSE NOTED, BUT SHT 7 OF 7 STILL SHOWS | | | INITIALS, AND NO LETTER HAS BEEN SUBMITTED. --THE | | | LICENSE FOR THE DESIGN PROFESSIONAL IS SHOWN IN | | | DELINQUENT STATUS ON THE FLORIDA STATE DBPR WEBSITE. | | | (SEE ATTACHED SHEET). PLEASE HAVE THE STATUS UPDATED | | | PRIOR TO RESUBMITTING. | | | | | | 3. SHT 1 0F 1. THE CERTIFICATE OF AUTHORIZATION NUMBER, | | | (FIRM LICENSE NUMBER),IS REQUIRED IN THE TITLE BLOCK | | | OF EACH SHEET AS WELL AS THE DATED SEAL, SIGNATURE, AND | | | PRINTED NAME OF THE PERSON SEALING THE DOCUMENT. FAC | | | 61G1-16.003, 61G1-16.004(2)(6) AND FS 481.219, | | | 481.2055.--THE SHEET HAS NOT BEEN SIGNED, SEALED & | | | DATED ALSO. SECTION 106.1. | | | ****RESPONSE NOTED, AND COMMENT IS OK,BUT THE LICENSE | | | FOR THE DESIGN PROFESSIONAL IS SHOWN IN DELINQUENT | | | STATUS ON THE FLORIDA STATE DBPR WEBSITE. (SEE ATTACHED | | | SHEET). PLEASE HAVE THE STATUS UPDATED PRIOR TO | | | RESUBMITTING. | | | | | | 4. SHT A-1.0 PER TABLE 403.1, MINIMUM FIXTURE | | | REQUIREMENTS FOR THE FIRST FLOOR INCLUDE 4 W/C'S, 3 | | | LAVS & 2 DRINKING FOUNTAINS. PLEASE INDICATE MINIMUM | | | FACILITIES. | | | ****RESPONSE NOTED, BUT ONLY 3 W/C'S ARE SHOWN. 4 W/C'S | | | REQUIRED. | | | | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | 8. SHT A-3.0 DETAIL #3 TOI.ET ROOMS SHALL BE | | | ACCESSIBLE. SHOW COMPLIANCE WITH SECTION 11-4.22 AND | | | ALL SUBSECTIONS. | | | ****RESPONSE NOTED, BUT NOT ADDRESSED. NO GRAB BARS | | | SHOWN, NO CLEAR FLOOR SPACE SHOWN, STILL INDICATESAS | | | ADAPTABLE. PLEASE SHOW THE TOILET ROOMS AS ACCESSIBLE. | | | SECTION 11-4.1.3(11). | | | | | | 9. SHT A-3.0 DETAILS #5 & #6 SINKS SHALL BE ACCESSIBLE. | | | SHOW COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS.--THE GARBAGE DISPOSALS SHALL BE ADA | | | COMPLIANT. PLEASE SUBMIT MANUF. SPECIFICATION SHEETS | | | WITH INSTALLATION INSTRUCTIONS. SECTION 106.1.2 MORE | | | INFORMATION REQD. | | | ****RESPONSE NOTED, BUT NOT COMPLETLY ADDRESSED. NO | | | CLEAR FLOOR SPACE SHOWN ON THE FLOOR PLAN, DIMENSIONS | | | AT TOE KICK NOT APPROVED. MAX 6" FROM WALL REQUIRED, | | | ONE DETAIL SHOWS 1'1" AND THE OTHER INDICATES 8-1/4". | | | PLEASE SHOW COMPLIANCE WITH FIG. 11-31.--ONLY ONE | | | COPY OF THE GARBAGE DISPOSAL FOUND, AND IT IS NOT | | | APPROVED. NO ADA APPROVAL IS SHOWN ON THE MANUF. | | | SPECIFICATION SHEET. | | | | | | 10. OK | | | | | | 11. SHT A-9.0 DETAIL #6 SINK SHALL BE ACCESSIBLE. | | | PLEASE SHOW COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. | | | ****RESPONSE NOTED, BUT COMPLIANCE SHALL BE SHOWN FOR | | | THE FOLLOWING: | | | A. 11-4.24.4 SINK DEPTH | | | B. 11-4.24.5 CLEAR FLOOR SPACE | | | C. 11-4.24.7 FAUCETS | | | | | | 12. OK | | | 13. OK | | | | | | 14. SHT A-9.1 DETAIL #3 SINK SHALL BE ACCESSIBLE. | | | PLEASE SHOW COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. | | | ****RESPONSE NOTED, BUT NOT COMPLETLY ADDRESSED. SHOW | | | COMPLIANCE WITH THE FOLLOWING: | | | A. 11-4.24.4 SINK DEPTH | | | B. 11-4.24.5 CLEAR FLOOR SPACE | | | C. 11-4.24.7 FAUCETS | | | | | | 15. OK | | | 16. OK | | | 17. OK | | | 18. OK | | | 19. OK | | | 20. OK | | | 21. OK | | | | | | 22. SHT P5.1 DOMESTIC WATER RISER DIAGRAM FOR RRW & | | | RRWR DOES NOT REFLECT THE FLOOR PLAN. PLEASE CORRELATE | | | RISER AND FLOOR PLAN. SECTION 106.1.1. ****RESPONSE | | | NOTED, BUT COMMENT NOT ADDRESSED COMPLETLY. RISER STILL | | | DOES NOT REFLECT THE FLOOR PLAN IN SOME AREAS. | | | | | | 23. OK | | | 24. OK (INDICATED AS A BALLCOCK STYLE FLOAT VALVE. IF | | | THERE IS AN AIR GAP, NO BACKFLOW IS REQUIRED). | | | | | | 25. SHT P5.1 THE SANITARY RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN. FUTURE 4" LINE FOR TENANT 2 IS | | | SHOWN ON THE 2ND FLOOR OF THE THE RISER DIAGRAM.-- | | | THE FLOOR DRAIN SHOWN ON THE FLOOR PLAN NEAR ROOM 105 | | | IS NOT SHOWN ON THE SANT. RISER DIAGRAM.--THE | | | CLEANOUT SHOWN ON THE FLOOR PLAN DOWNSTREAM OF THE LAV | | | IN THE WOMENS TOILET ROOM 2ND FLOOR IS NOT SHOWN ON THE | | | RISER DIAGRAM.--ONLY ONE EWC IS INDICATED. THE EWC | | | BY THE RECEPTION AREA IS NOT SHOWN ON THE RISER | | | DIAGRAM.--RISER SHOWS AN EXTRA FLOOR DRAIN AND VENT | | | UPSTREAM OF THE ONE SHOWN IN THE ELEVATOR MACHINE ROOM, | | | (TO BE DELETED PER SECTION 301.6).--NOTE #3 AT THE | | | TWO WAY CLEANOUT NEAR THE JUNCTION OF THE BUILDING | | | DRAIN AND THE BUILDING SEWER DOES NOT REFLECT KEY NOTE | | | #3. PLEASE CHECK THAT THE RISER DIAGRAM. CORRELATES | | | WITH THE FLOOR PLAN. SECTION 106.1.1. | | | ****RESPONSE NOTED, BUT THE VENT FOR THE FLOOR DRAIN BY | | | THE ELECTRICAL ROOM APPEARS TO OFFSET BELOW THE SLAB. | | | PER SECTION 905.4 THE VENT SHALL RISE VERTICALLY A | | | MINIMUM 6" ABOVE THE FLOOD RIM LEVEL PRIOR TO | | | OFFSETTING HORIZONTALLY.--THE 4" BRANCH LINE FOR | | | THE FUTURE TENANT IS SHOWN DOWNSTREAM OF THE SECOND | | | FLOOR RISER ON THE FLOOR PLAN, BUT UPSTREAM OF THE | | | RISER ON THE ISOMETRIC RISER DIAGRAM. PLEASE CORRELATE. | | | | | | | | | 26. OK | | | 27. OK | | | 28. OK | | | 29. OK | | | 30. OK | | | 31. OK | | | 32. OK | | | | | | 33. THE APPLICATION STATES "DESCRIBE PROJECT IN DETAIL" | | | (FAILURE TO DO SO MAY RESULT IN DELAYS). IT APPEARS | | | THAT THE SECOND FLOOR WILL BE BUILT OUT,BUT THE FIRST | | | FLOOR WILL BE SHELL ONLY WITH THIS PERMIT. THIS IS NOT | | | INDICATED ON THE PERMIT APPLICATION, (NEW BUILD). | | | PLEASE INDICATE THE SCOPE OF WORK FOR THIS PERMIT AS | | | REQUIRED ON THE APPLICATION. | | | ****RESPONSE NOTED, WILL CHECK WHEN THE APPLICATION IS | | | RETURNED. | | | | | | **********NEW COMMENT********** | | | | | | 1B. SEE ATTACHED SHEET CONCERNING THE DESIGN | | | PROFESSIONAL & FS 553.80(2)(B). THIS IS GIVEN AS A | | | NOTICE ONLY AT THIS TIME. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | ****RESPONSE NOTED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-06 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-05 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2007-09-06 18:10:26 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1.ALL SHEETS. THE ADDRESS OF THE PROJECT SHALL BE | | | INDICATED IN THE TITLE BLOCK OF EACH SHEET. SECTION | | | 106.1.1. | | | | | | 2. SHTS 1 THRU 3 OF 3 & 1 THRU 7 OF 7. THE CERTIFICATE | | | OF AUTHORIZATION NUMBER, (FIRM LICENSE NUMBER),IS | | | REQUIRED IN THE TITLE BLOCK OF EACH SHEET AS WELL AS | | | THE DATED SEAL, SIGNATURE, AND PRINTED NAME OF THE | | | PERSON SEALING THE DOCUMENT. FAC 61G1-16.003, | | | 61G1-16.004(2)(6) AND FS 481.219, 481.2055.--IT | | | APPEARS THAT THE PLANS HAVE BEEN SIGNED WITH A | | | INITIALS, NOT A SIGNATURE. IF INDEED THIS IS THE LEGAL | | | SIGNATURE OF THE ENGINEER, THEN A SIGNED, SEALED, | | | LEGALLY NOTORIZED LETTER INDICATING THE LEGAL ADDRESS | | | OF THE LANDSCAPE ARCHITECT SHALL BE SUBMITTED FOR OUR | | | FILES. | | | | | | 3. SHT 1 0F 1. THE CERTIFICATE OF AUTHORIZATION NUMBER, | | | (FIRM LICENSE NUMBER),IS REQUIRED IN THE TITLE BLOCK | | | OF EACH SHEET AS WELL AS THE DATED SEAL, SIGNATURE, AND | | | PRINTED NAME OF THE PERSON SEALING THE DOCUMENT. FAC | | | 61G1-16.003, 61G1-16.004(2)(6) AND FS 481.219, | | | 481.2055.--THE SHEET HAS NOT BEEN SIGNED, SEALED & | | | DATED ALSO. SECTION 106.1. | | | | | | 4. SHT A-1.0 PER TABLE 403.1, MINIMUM FIXTURE | | | REQUIREMENTS FOR THE FIRST FLOOR INCLUDE 4 W/C'S, 3 | | | LAVS & 2 DRINKING FOUNTAINS. PLEASE INDICATE MINIMUM | | | FACILITIES. | | | | | | 5. SHT A-2.0 PER TABLE 403.1, TWO DRINKING FOUNTAINS | | | ARE REQUIRED. ONLY ONE IS SHOWN ON THE FLOOR PLAN. | | | PLEASE INDICATE THE LOCATION OF TWO DRINKING FOUNTAINS | | | ON THE FLOOR PLAN. | | | | | | 6. SHT A-2.0 KEY NOTE #11 NOT FOUND. PLEASE INDICATE | | | THE ROOM NUMBER KEY NOT CAN BE LOCATED. SECTION | | | 106.1.1. | | | | | | 7. SHTS A-2.0, A-2.1, A-2.4, A-3.0 (DETAIL #2)AND SHT | | | P1.2. PER SECTION 11-4.17.3 EXCEPTION NEW CONSTRUCTION | | | (2), THE ACCESSIBLE W/C SHALL BE LOCATED IN THE CORNER | | | DIAGONAL TO THE DOOR. THE W/C IN THE ACCESSIBLE STALL | | | IN THE WOMENS TOILET ROOM (225) DOES NOT MEET THIS | | | REQUIREMENT. PLEASE MOVE DOOR OR W/C TO COMPLY. | | | | | | 8. SHT A-3.0 DETAIL #3 TOI.ET ROOMS SHALL BE | | | ACCESSIBLE. SHOW COMPLIANCE WITH SECTION 11-4.22 AND | | | ALL SUBSECTIONS. | | | | | | 9. SHT A-3.0 DETAILS #5 & #6 SINKS SHALL BE ACCESSIBLE. | | | SHOW COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS.--THE GARBAGE DISPOSALS SHALL BE ADA | | | COMPLIANT. PLEASE SUBMIT MANUF. SPECIFICATION SHEETS | | | WITH INSTALLATION INSTRUCTIONS. SECTION 106.1.2 MORE | | | INFORMATION REQD. | | | | | | 10. SHT A-9.0 DETAILS #2 & #5 THE FLUSH CONTROL FOR THE | | | W/C SHALL BE TO THE WIDE SIDE OF THE W/C PER SECTION | | | 11-4.16.5. PLEASE SHOW ON DETAILS. | | | | | | 11. SHT A-9.0 DETAIL #6 SINK SHALL BE ACCESSIBLE. | | | PLEASE SHOW COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. | | | | | | 12. SHT A-9.0 DETAIL #12 THE URINAL SHALL BE | | | ACCESSIBLE. PLEASE SHOW COMPLIANCE WITH SECTION | | | 11-4.18.4, MAX HEIGHT FOR FLUSH CONTROLS. (44"). | | | | | | 13. SHT A-9.0 DETAIL #12 THE LAVS SHALL BE ACCESSIBLE. | | | PLEASE SHOW COMPLIANCE WITH SECTIONS 11-4.19.4 EXPOSED | | | PIPES & SURFACES, AND 11-4.19.5 FAUCETS. | | | | | | 14. SHT A-9.1 DETAIL #3 SINK SHALL BE ACCESSIBLE. | | | PLEASE SHOW COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. | | | | | | 15. SHTS S-1 THRU S-6 THE ENGINEER SHALL LEGIBLY | | | INDICATE THEIR ADDRESS IN THE TITLE BLOCK. FAC | | | 61G15-23.002(2) & FS 471.025. | | | | | | 16. ALL M, E, P & FP SHEETS. THE ENGINEER SHALL LEGIBLY | | | INDICATE THEIR ADDRESS AND IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS, THE ADDRESS OF THE | | | ENGINEERING BUSINESS IS REQUIRED AS WELL. FAC | | | 61G15-23.002(2) & FS 471.025. AS SHOWN, THE ADDRESS OF | | | THE ENGINEER IS SHOWN, BUT THE ADDRESS OF THE | | | ENGINEERING BUSINESS, (INDICATED AS 797 ANDREWS AVE., | | | DELRAY BEACH ON THE FLORIDA STATE DBPR WEBSITE), IS NOT | | | SHOWN IN THE TITLE BLOCKS. (SEE ATTACHED SHEET). PLEASE | | | INCLUDE THE BUSINESS ADDRESS IN THE TITLE BLOCKS. IF | | | THE ADDRESS IS DIFFERENT FROM THE DBPR WEBSITE, PLEASE | | | UPDATE THE DBPR WEBSITE PRIOR TO RESUBMITTING FOR | | | REVIEW AT THE CITY WPB. | | | | | | 17. SHT P0.3 ABBREIVIATIONS RRW & RRWR ARE NOT | | | INDICATED IN THE LIST OF ABBREIVIATIONS ON SHT P0.1. | | | PLEASE CLARIFY WHAT THE ABBREIVIATIONS STAND FOR. | | | SECTION 106.1.2. | | | | | | 18. SHT P1.1 NOTE: 3" FROM RAIN WATER PIPING. REFER | | | ARCHITECTURAL FOR CONT. & DETAILS. PLEASE INDICATE | | | WHERE ON THE ARCHITECTURAL SHEETS THIS CAN BE FOUND. | | | SECTION 106.1.2. | | | | | | 19. SHT P1.1 KEYED NOTES #12 IS NOT INDICATED ON THE | | | FLOOR PLAN. PLEASE INDICATE WHERE #12 CAN BE FOUND.-- | | | THE SANITARY RISER NEXT TO STAIR #2 IS NOT IDENTIFIED. | | | PLEASE IDENTIFY THIS RISER. SECTION 106.1.1. | | | | | | 20. SHT P1.1 FLOOR DRAIN IN THE ELEVATOR MACHINE ROOM. | | | SECTION 301.6. PLEASE DELETE FROM FLOOR PLAN & SANITARY | | | RISER DIAGRAM. | | | | | | 21. SHT P1.2 VENT FROM EWC BY THE WATER HEATER DOES NOT | | | CONNECT TO OR SHOW VTR. PLEASE CLARIFY. SECTIONS | | | 106.1.1 AND 901.2.1. | | | | | | 22. SHT P5.1 DOMESTIC WATER RISER DIAGRAM FOR RRW & | | | RRWR DOES NOT REFLECT THE FLOOR PLAN. PLEASE CORRELATE | | | RISER AND FLOOR PLAN. SECTION 106.1.1. | | | | | | 23. SHT P5.1 DOMESTIC WATER RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN. PIPING AT THE BAR SINK, THE | | | JANITOR SINK. THE LINE TO THE HOSE BIBB THAT ALSO | | | INDICATES A LINE THAT CONNECTS TO THE RRW LINE IS NOT | | | SHOWN ON THE FLOOR PLAN. PLEASE CORRELATE. SECTION | | | 106.1.1. | | | | | | 24. SHT P5.1 THE CHECK VALVE SHOWN BETWEEN THE DCW AND | | | THE RRW IS NOT APPROVED. AN RPZV BACKFLOW IS REQUIRED | | | FOR PROTECTION OF THE POTABLE WATER FROM A POSSIBLE | | | CROSS CONNECTION. SECTION 608.13.2. | | | | | | 25. SHT P5.1 THE SANITARY RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN. FUTURE 4" LINE FOR TENANT 2 IS | | | SHOWN ON THE 2ND FLOOR OF THE THE RISER DIAGRAM.-- | | | THE FLOOR DRAIN SHOWN ON THE FLOOR PLAN NEAR ROOM 105 | | | IS NOT SHOWN ON THE SANT. RISER DIAGRAM.--THE | | | CLEANOUT SHOWN ON THE FLOOR PLAN DOWNSTREAM OF THE LAV | | | IN THE WOMENS TOILET ROOM 2ND FLOOR IS NOT SHOWN ON THE | | | RISER DIAGRAM.--ONLY ONE EWC IS INDICATED. THE EWC | | | BY THE RECEPTION AREA IS NOT SHOWN ON THE RISER | | | DIAGRAM.--RISER SHOWS AN EXTRA FLOOR DRAIN AND VENT | | | UPSTREAM OF THE ONE SHOWN IN THE ELEVATOR MACHINE ROOM, | | | (TO BE DELETED PER SECTION 301.6).--NOTE #3 AT THE | | | TWO WAY CLEANOUT NEAR THE JUNCTION OF THE BUILDING | | | DRAIN AND THE BUILDING SEWER DOES NOT REFLECT KEY NOTE | | | #3. PLEASE CHECK THAT THE RISER DIAGRAM. CORRELATES | | | WITH THE FLOOR PLAN. SECTION 106.1.1. | | | | | | 26. SHT P5.1 KEY NOTE 11 PAN DRAIN NOT SHOWN. CORRELATE | | | NOTE AND RISER DIAGRAM. SECTION 106.1.1. | | | | | | 27. SHT P5.1 KEY NOTE 16. TWO PUMPS ARE SHOWN. PLEASE | | | CLARIFY. SUBMIT A DETAIL FOR THE PIPING TO THE PUMPS AT | | | THE CISTERN. SECTION 106.1.2. | | | | | | 28. SUBMIT MANUF. SPECIFICATION SHEETS FOR ALL PUMPS. | | | SHEETS SHALL SHOW A LISTING AND MANUF. INSTALLATION | | | INSTRUCTIONS. SECTION 303.4. | | | | | | 29. DURING A CONVERSATION WITH THE ELECTRICAL PLAN | | | REVIEWER, IT WAS BROUGHT TO MY ATTENTION THAT THE HOUSE | | | PANEL ON SHT E8.1 ONLY SHOWS ONE BOOSTER PUMP AND ONE | | | RECIRCULATION PUMP. TWO OF EACH PUMP ARE SHOWN ON THE | | | PLUMBING SHEET P5.1. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 30. SHT P5.1 KEY NOTES 14 INDICATES A WATER FILTER. | | | PLEASE EXPLAIN THE 2 VFD'S TO THE LEFT OF THE FILTER. | | | SECTION 106.1.2 MORE INFORMATION REQUIRED. | | | | | | 31. SHT P5.1 KEY NOTE 2 INDICATES A CLEANOUT 36" BELOW | | | THE FINISH FLOOR. SECTION 708.4 REQUIRES THAT CLEANOUTS | | | SHALL BE EXTENDED THROUGH AND SHALL TERMINATE FLUSH | | | WITH THE FINISHED FLOOR. PLEASE CORRECT KEY NOTE. | | | | | | 32. SUBMIT A CONDENSATE ISOMETRIC RISER DIAGRAM. SHOW | | | ALL PIPE SIZES AND INDICATE VENTS. SECTION | | | 106.3.5.1.3(13). | | | | | | 33. THE APPLICATION STATES "DESCRIBE PROJECT IN DETAIL" | | | (FAILURE TO DO SO MAY RESULT IN DELAYS). IT APPEARS | | | THAT THE SECOND FLOOR WILL BE BUILT OUT,BUT THE FIRST | | | FLOOR WILL BE SHELL ONLY WITH THIS PERMIT. THIS IS NOT | | | INDICATED ON THE PERMIT APPLICATION, (NEW BUILD). | | | PLEASE INDICATE THE SCOPE OF WORK FOR THIS PERMIT AS | | | REQUIRED ON THE APPLICATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-11-19 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-11-19 |
Time |
16:13 |
Sent To |
|
|
| Notes |
| 2007-11-19 16:23:20 | PLANNING AND ZONING: ****FAILED ***** | | | | | | | | | 1.RESPOND TO COMMENTS IN WRITING. | | | | | | 2.THE APPLICATION FOR A FORMAL SITE PLAN REVIEW IN | | | THE PLANNING AND ZONING DEPARTMENT WAS DENIED ON | | | NOVEMBER 5, 2007 (SEE ATTACHED DENIAL LETTER). | | | PURSUANT TO SECTION 94-36(E)(2), WHEN AN APPLICATION IS | | | DENIED, ZONING CLEARANCE OR CERTIFICATE OF OCCUPANCY | | | SHALL NOT BE ISSUED. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-08-09 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-08-06 |
Time |
17:17 |
Sent To |
|
|
| Notes |
| 2007-08-06 11:03:57 | PLANNING AND ZONING: ****FAILED ***** | | | | | | | | | 1.RESPOND TO COMMENTS IN WRITING. | | | | | | 2.THE PROJECT IS CURRENTLY UNDER A FORMAL SITE PLAN | | | REVIEW IN THE PLANNING AND ZONING DEPARTMENT.FINAL | | | APPROVAL OF THE PLANS HAS NOT BEEN GIVEN, THEREFORE, | | | BUILDING PERMIT CAN NOT BE APPROVED AT THIS TIME. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|
|