Plan Review Details - Permit 07070307
Plan Review Stops For Permit 07070307
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-09-11 Cont ID  
Sent By shill Date 2007-09-11 Time 11:01 Rev Time 0.00
Received By shill Date 2007-09-11 Time 11:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2007-08-31 Cont ID  
Sent By shill Date 2007-08-31 Time 11:03 Rev Time 0.00
Received By shill Date 2007-08-31 Time 11:03 Sent To  
Notes
2007-08-31 11:10:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)SPAN OF 7.5' REQUIERS USE OF THE 8' ROWS.SEE
 OPENING 1, 91 1/2" SPAN AND SHEET 14 OF THE PRODUCT
 APPROVAL.FOR A DESIGN PRESSURE OF -56.15, YOU MUST
 USE THE -60PSF CHART, 8.5" REQUIRED.YOU'VE HIGHLGHTED
 THE -75PSF COLUMN (7") BUT HAVE WRITTEN 9" ON THE
 INSTALLATION SCHEDULE.
  
 2.)OPENING 2, SPAN OF 61", 67.32 PSF, REQUIRES USE OF
 THE 6', 75PSF COLUMN, 8"SPACING FOR CONNECTION E, SEE
 SHEET 14.
  
 IF YOU DO NOT UNDERSTAND THESE COMMENTS, PLEASE HAVE
 THE QUALIFIER CONTACT ME.IT APPEARS FROM THE
 INSTALLATION SCHEDULE THAT YOU UNDERSTAND WHAT
 INFORMATION WE ARE ASKING FOR BUT ARE USING THE WRONG
 COLUMN OR ROWS (WRONG SPANS).THE SPAN SHOULD BE ONE
 NUMBER, BLADE LENGTH, FOR ACCORDIONS.YOU HAVE TWO
 DIMENSIONS BUT ANCHOR SPACING DOES NOT COMPLY WITH THE
 SMALLEST DIMENSION WHICH IN EACH CASE IS THE SHUTTER
 HEIGHT.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-08-26 Cont ID  
Sent By shill Date 2007-08-26 Time 16:42 Rev Time 0.00
Received By shill Date 2007-08-26 Time 16:42 Sent To  
Notes
2007-08-26 16:44:58****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)THE EDGE DISTANCE HAS BEEN CHANGED FROM 3 1/2" TO
 3".YOU HAVE HIGHLIGHTED THE .83 FACTOR ON THE PRODUCT
 APPROVAL, BUT DID NOT REVISE THE ANCHOR SPACING.9
 TIMES .83 GIVES A REQUIRED 7.47 ANCHOR SPACING.REVISE
 THE INSTALLATION SCHEDULE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-20 Cont ID  
Sent By shill Date 2007-08-20 Time 10:31 Rev Time 0.00
Received By shill Date 2007-08-20 Time 10:31 Sent To  
Notes
2007-08-20 10:34:28****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)CONNECTION TYPES B AND G REQUIRE CONCRETE
 SUBSTRATES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-03 Cont ID  
Sent By shill Date 2007-08-03 Time 15:31 Rev Time 0.00
Received By shill Date 2007-08-03 Time 15:31 Sent To  
Notes
2007-08-03 15:32:04****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)THE INSTALLATION SCHEDULE DOES NOT CORRELATE WITH
 THE PRODUCT APPROVAL.CONNECTION MOUNTING TYPES ON THE
 INSTALLATION SCHEDULE ARE C4, C5, BUT THE PRODUCT
 APPROVAL LABELS THEM A THROUGH L.PLEASE REVISE.
  

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-09-06 Cont ID  
Sent By adarroug Date 2007-09-06 Time 08:26 Rev Time 0.00
Received By adarroug Date 2007-09-06 Time 08:26 Sent To B
Notes
2007-09-06 08:26:54TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-29 Cont ID  
Sent By adarroug Date 2007-08-29 Time 15:59 Rev Time 0.00
Received By adarroug Date 2007-08-29 Time 15:59 Sent To B
Notes
2007-08-29 16:00:02TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-22 Cont ID  
Sent By adarroug Date 2007-08-22 Time 16:30 Rev Time 0.00
Received By adarroug Date 2007-08-22 Time 16:30 Sent To B
Notes
2007-08-22 16:31:16TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-08 Cont ID  
Sent By mmiller Date 2007-08-08 Time 18:17 Rev Time 0.00
Received By mmiller Date 2007-08-08 Time 18:17 Sent To B
Notes
2007-08-08 18:17:41SENT TO SAMANTHA HILL'S DESK MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-03 Cont ID  
Sent By shill Date 2007-08-03 Time 15:32 Rev Time 0.00
Received By shill Date 2007-07-13 Time 11:51 Sent To  
Notes
2007-07-13 11:51:32TO "MISC' BOX#1