Plan Review Details - Permit 07070306
Plan Review Stops For Permit 07070306
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2008-03-03 Cont ID  
Sent By rmcdouga Date 2008-03-03 Time 10:18 Rev Time 0.00
Received By rmcdouga Date 2008-03-03 Time 10:18 Sent To  
Notes
2008-03-03 10:31:12REVISION TO CHANGE TO UNVENTED ATTIC WITH ICYNENE SPRAY
 INSULATION IS OK. LETTER FROM DESIGNER OF RECORD AND
 REVISED DETAIL WERE SUBMITTED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-11-05 Cont ID  
Sent By rmcdouga Date 2007-11-05 Time 09:39 Rev Time 0.00
Received By rmcdouga Date 2007-11-05 Time 09:38 Sent To  
Notes
2007-11-05 09:39:24PROCESS PLANS

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-11-01 Cont ID  
Sent By rmcdouga Date 2007-11-01 Time 10:05 Rev Time 0.00
Received By rmcdouga Date 2007-11-01 Time 10:05 Sent To M
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-05 Cont ID  
Sent By rmcdouga Date 2007-10-05 Time 16:55 Rev Time 0.00
Received By rmcdouga Date 2007-10-05 Time 16:55 Sent To  
Notes
2007-10-05 17:24:13DENIED BY BUILDING
  
 1) SUBMIT A DRAINAGE PLAN OR SITE PLAN SHOWING
 COMPLIANCE WITH R401.3 DRAINAGE .
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048
 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
  
 2) THE TRUSS BOTTOM CORD LIVE LOAD SPECIFIED ON A3 AS 0
 IS INCORRECT. TABLE R301.5 REQUIRES A LIVE LOAD OF 10
 PSF FOR ATTICS WITHOUT STORAGE AND 20 PSF WITH STORAGE.
 PLEASE CORRECT.
  
 3)ROOF SHEATHING IS REQUIRED TO BE FASTENED IN
 ACCORDANCE WITH SECTION R803.2.3.1 OF 2006 REVISIONS TO
 2004 FBC RESIDENTIAL CODE. WHICH REQUIRES 8D RING-SHANK
 NAILS TO BE USED IN ALL ROOF ZONES. PLEASE REVISE THE
 TYPICAL ROOF NOTES ON A3.
  
 4) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND LISTING
 INFORMATION FOR THE BUILT IN BBQ AND HOOD. SEE
 G2447.1.
  
 5) SUBMIT PRODUCT APPROVALS FOR THE CASEMENT WINDOWS AS
 REQUIRED BY FAC RULE 9B-72.
 BATHROOM WINDOWS TO BE SAFETY GLAZING OR IMPACT RATED
 TO COMPLY WITH R308.
  
 6) THE DESIGN PRESSURES FOR THE DALTON SECTIONAL GARAGE
 DOORS ARE LOWER THAN THE REQUIRED COMPONENT AND
 CLADDING PRESSURES LISTED ON THE PLANS.
  
 7) THE SBCCI REPORT #2203 HAS BEEN REVISED AND REISSUED
 AS AN ICC LEGACY REPORT ON JAN. 1, 2005. PLEASE SUBMIT
 THE REVISED REPORT THAT IS POSTED ON THE STATE PRODUCT
 APPROVAL WEBSITE. PLEASE SPECIFY WHICH ONE OF THE ROOF
 TILES FROM THE REPORT WILL BE INSTALLED.
  
 8) ONE OF THE REVISED A2 SHEETS OF THE PLANS HAS A
 HANDWRITTEN NOTE ACROSS THE PAGE. PLEASE SUBMIT CLEAN
 DRAWINGS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-25 Cont ID  
Sent By rmcdouga Date 2007-07-25 Time 07:33 Rev Time 0.00
Received By rmcdouga Date 2007-07-25 Time 07:33 Sent To P
Notes
2007-07-25 10:26:06DENIED BY BUILDING
  
 1)THE EXPOSURE CATEGORY FOR THIS STRUCTURE IS "C"
 RATHER THAN "B". REVISE DESIGN PRESSURES ACCORDINGLY.
 R301.2.1.4 EXPOSURE CATEGORY.
 FOR EACH WIND DIRECTION CONSIDERED, AN EXPOSURE
 CATEGORY THAT ADEQUATELY REFLECTS THE CHARACTERISTICS
 OF GROUND SURFACE IRREGULARITIES SHALL BE DETERMINED
 FOR THE SITE AT WHICH THE BUILDING OR STRUCTURE IS TO
 BE CONSTRUCTED. FOR A SITE LOCATED IN THE TRANSITION
 ZONE BETWEEN CATEGORIES, THE CATEGORY RESULTING IN THE
 LARGEST WIND FORCES SHALL APPLY. ACCOUNT SHALL BE TAKEN
 OF VARIATIONS IN GROUND SURFACE ROUGHNESS THAT ARISE
 FROM NATURAL TOPOGRAPHY AND VEGETATION AS WELL AS FROM
 CONSTRUCTED FEATURES. FOR ANY GIVEN WIND DIRECTION, THE
 EXPOSURE IN WHICH A SPECIFIC BUILDING OR OTHER
 STRUCTURE IS SITED SHALL BE ASSESSED AS BEING ONE OF
 THE FOLLOWING CATEGORIES: 3. EXPOSURE C. OPEN TERRAIN
 WITH SCATTERED OBSTRUCTIONS, INCLUDING SURFACE
 UNDULATIONS OR OTHER IRREGULARITIES, HAVING HEIGHTS
 GENERALLY LESS THAN 30 FEET (9144 MM) EXTENDING MORE
 THAN 1,500 FEET (457.2 M) FROM THE BUILDING SITE IN ANY
 QUADRANT. THIS EXPOSURE SHALL ALSO APPLY TO ANY
 BUILDING LOCATED WITHIN EXPOSURE B-TYPE TERRAIN WHERE
 THE BUILDING IS DIRECTLY ADJACENT TO OPEN AREAS OF
 EXPOSURE C-TYPE TERRAIN IN ANY QUADRANT FOR A DISTANCE
 OF MORE THAN 600 FEET (182.9 M). SHORT-TERM (LESS THAN
 TWO YEAR) CHANGES IN THE PRE-EXISTING TERRAIN EXPOSURE,
 FOR THE PURPOSES OF DEVELOPMENT, SHALL NOT BE
 CONSIDERED OPEN FIELDS. WHERE DEVELOPMENT BUILD OUT
 WILL OCCUR WITHIN THREE YEARS AND THE RESULTANT
 CONDITION WILL MEET THE DEFINITION OF EXPOSURE B,
 EXPOSURE B SHALL BE REGULATING FOR THE PURPOSE OF
 PERMITTING. THIS CATEGORY INCLUDES FLAT OPEN COUNTRY,
 GRASSLANDS AND OCEAN OR GULF SHORELINES. THIS CATEGORY
 DOES NOT INCLUDE INLAND BODIES OF WATER THAT PRESENT A
 FETCH OF 1 MILE (1.61 KM) OR MORE OR INLAND WATERWAYS
 OR RIVERS WITH A WIDTH OF 1 MILE (1.61 KM) OR MORE (SEE
 EXPOSURE D). REVISE THE COMPONENT AND CLADDING
 PRESSURES ON THE PLANS.
  
 2) SUBMIT A DRAINAGE PLAN SHOWING COMPLIANCE WITH
 R401.3 DRAINAGE .
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048
 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
  
 3) THE TRUSS BOTTOM CORD LIVE LOAD SPECIFIED ON A3 AS 0
 IS INCORRECT. TABLE R301.5 REQUIRES A LIVE LOAD OF 10
 PSF FOR ATTICS WITHOUT STORAGE AND 20 PSF WITH STORAGE.
 PLEASE CORRECT.
  
 4)ROOF SHEATHING IS REQUIRED TO BE FASTENED IN
 ACCORDANCE WITH SECTION R803.2.3.1 OF 2006 REVISIONS TO
 2004 FBC RESIDENTIAL CODE. WHICH REQUIRES 8D RING-SHANK
 NAILS TO BE USED IN ALL ROOF ZONES. PLEASE REVISE THE
 TYPICAL ROOF NOTES ON A3.
  
 5) THE STEEL COLUMNS AT THE FRONT ENTRY ARE NOT SHOWN
 ON THE ROOF FRAMING PLAN ON A3.
  
 6) SPECIFY ON THE PLANS THE LOCATIONS THAT THE BEAM
 HANGER N/6 ON A6 WILL BE INSTALLED.
  
 7) SPECIFY THE LENGTH/EMBED DEPTH FOR THE 1/2" DIAMETER
 EXPANSION ANCHOR BOLTS FOR THE STEEL COLUMNS IN THE
 DETAILS ON A6.
  
 8) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 CALCULATION FORMS. SEE FBC CHAPTER 13.
  
 9) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND LISTING
 INFORMATION FOR THE BUILT IN BBQ AND HOOD.
  
 10)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 11) SUBMIT PRODUCT APPROVALS FOR THE CASEMENT WINDOWS.
 BATHROOM WINDOWS TO BE SAFETY GLAZING OR IMPACT RATED
 TO COMPLY WITH R308.
  
 12) THE EVALUATION AND INSTALLATION INFORMATION FOR THE
 EXCLUSIVE WOOD DOORS FL 1876 HAS BEEN REVISED BY FL
 1876-R1. SUBMIT THE NEW INFORMATION THAT IS POSTED ON
 THE STATE PRODUCT APPROVAL WEBSITE AT
 WWW.FLORIDABUILDING.ORG.
  
 13) THE PRODUCT APPROVAL FOR THE WAYNE DALTON SECTIONAL
 GARAGE DOOR HAS THE EVAULATION REPORT FOR MODEL 9100
 AND THE DRAWINGS FOR MODEL 8000/8100. PLEASE CORRECT.
  
 14) THE FIXED WINDOW NOTES ON A1 SPECIFY PGT 820
 WINDOWS , NOA 03-0508.01, WHICH ARE RATED FOR SMALL
 MISSILE IMPACT ONLY. THE PRODUCT APPROVAL SUBMITTED IS
 FOR PGT PW-701 FIXED WINDOWS, WHICH ARE RATED FOR LARGE
 AND SMALL MISSILE IMPACT. PLEASE REVISE PLANS.
  
 15) THE PRODUCT APPROVAL SUBMITTED FOR THE SINGLE HUNG
 WINDOWS PGT-701 HAS BEEN REVISED TO PGT SH-700AND NOA
 05-1018.01. PLEASE SUBMIT CURRENT PRODUCT APPROVAL.
  
 16) THE PRODUCT APPROVAL SUBMITTED FOR THE PGT FD-101
 FRENCH DOORS WITH SIDELITES HAS BEEN REVISED BY NOA
 06-0807.07. PLEASE SUBMIT CURRENT PRODUCT APPROVAL.
  
 17) SUBMIT PRODUCT APPROVALS FOR THE DOUBLE OUTSWING
 FRENCH DOORS WITHOUT SIDELITES.
  
 18) THE NOA SUBMITTED FOR THE PGT 2" MULLIONS IS
 EXPIRED. THE NEW NOA IS 06-0125.08.
  
 19) THE SBCCI REPORT #2203 HAS BEEN REVISED AND
 REISSUED AS AN ICC LEGACY REPORT ON JAN. 1, 2005.
 PLEASE SUBMIT THE REVISED REPORT THAT IS POSTED ON THE
 STATE PRODUCT APPROVAL WEBSITE.
  
 21) PLEASE CHECK THE DESIGN PRESSURES OF THE PRODUCTS
 TO BE SURE THAT THEY ARE EQUAL OR GREATER THAN THE
 PRESSURES OF THE OPENINGS SPECIFIED ON THE PLANS WHEN
 THEY HAVE BEEN REVISED TO EXPOSURE CATEGORY "C".
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-07-10 Cont ID  
Sent By btrobaug Date 2008-07-10 Time 14:12 Rev Time 0.00
Received By btrobaug Date 2008-07-10 Time 14:11 Sent To PC
Notes
2008-07-10 14:12:18 
  
 REVISION "AS-BUILT" HILIGHTED SAME./WRT.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-10-30 Cont ID  
Sent By btrobaug Date 2007-10-30 Time 07:44 Rev Time 0.00
Received By btrobaug Date 2007-10-30 Time 07:06 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-09-24 Cont ID  
Sent By btrobaug Date 2007-09-24 Time 07:36 Rev Time 0.00
Received By btrobaug Date 2007-09-24 Time 07:08 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-18 Cont ID  
Sent By btrobaug Date 2007-07-18 Time 07:06 Rev Time 0.00
Received By btrobaug Date 2007-07-17 Time 16:36 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-07-18 Cont ID  
Sent By shill Date 2008-07-18 Time 12:32 Rev Time 0.00
Received By shill Date 2008-07-18 Time 12:32 Sent To Z
Notes
2008-07-18 12:32:45LANDSCAPE PLAN TO MCRUZ DESK PER MCRUZ REQUEST

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-07-10 Cont ID  
Sent By adarroug Date 2008-07-10 Time 10:01 Rev Time 0.00
Received By adarroug Date 2008-07-10 Time 10:00 Sent To Z
Notes
2008-07-10 10:01:14TO "Z" BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-07-09 Cont ID  
Sent By adarroug Date 2008-07-09 Time 16:30 Rev Time 0.00
Received By adarroug Date 2008-07-09 Time 16:30 Sent To E
Notes
2008-07-09 16:30:41TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-02-29 Cont ID  
Sent By adarroug Date 2008-02-29 Time 11:30 Rev Time 0.00
Received By adarroug Date 2008-02-29 Time 11:30 Sent To B
Notes
2008-02-29 11:30:21TO "RMCDOUGAL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-25 Cont ID  
Sent By adarroug Date 2007-10-25 Time 12:25 Rev Time 0.00
Received By adarroug Date 2007-10-25 Time 12:25 Sent To Z
Notes
2007-10-25 12:26:04TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-13 Cont ID  
Sent By adarroug Date 2007-09-13 Time 15:35 Rev Time 0.00
Received By adarroug Date 2007-09-13 Time 15:35 Sent To Z
Notes
2007-09-13 15:35:25TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-26 Cont ID  
Sent By jleech Date 2007-07-26 Time 09:28 Rev Time 0.00
Received By jleech Date 2007-07-13 Time 09:51 Sent To  
Notes
2007-07-13 09:52:01TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-11-01 Cont ID  
Sent By tgordon Date 2007-11-01 Time 11:45 Rev Time 0.30
Received By tgordon Date 2007-11-01 Time 11:45 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-10-30 Cont ID  
Sent By tgordon Date 2007-10-30 Time 13:40 Rev Time 0.35
Received By tgordon Date 2007-10-30 Time 13:40 Sent To P
Notes
2007-10-30 13:56:29PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 *** DENIED ***
 1) SEE MECHANICAL PLAN UTILITY ROOM 6" T-FIN IS TO
 SMALL AN OPENING FOR MAKE-UP AIR FOR THE GAS CLOTHES
 DRYER. SEE FBC/R G2439.4 (614.5) MAKEUP AIR.
 INSTALLATIONS EXHAUSTING MORE THAN 200 CFM (0.09 M 3
 /S) SHALL BE PROVIDED WITH MAKEUP AIR. WHERE A CLOSET
 IS DESIGNED FOR THE INSTALLATION OF A CLOTHES DRYER, AN
 OPENING HAVING AN AREA OF NOT LESS THAN 100 SQUARE
 INCHES (0.0645 M 2 ) FOR MAKEUP AIR SHALL BE PROVIDED
 IN THE CLOSET ENCLOSURE, OR MAKEUP AIR SHALL BE
 PROVIDED BY OTHER APPROVED MEANS. PLEASE CORRECT.
  
 2) CHANGES TO PLANS MAY NOT BE MADE BY HAND, AS THE
 PLANS MAY HAVE BEEN CHANGED ANY TIME AFTER THE REVIEW.
 PLEASE MAKE NEEDED CORRECTIONS TO MECHANICAL PLANS
 BEFORE RE-COPYING.
  
 3) PLEASE SHOW THE JOB ADDRESS IN THE TITLE BLOCK OF
 THE MECHANICAL PLAN, SEE WPB AMEND. 106.1.3.
  
 *** NO FEE TO BE CHARGED ON NEXT MECHANICAL REVIEW AS
 REVIEW ON 9-13-07 MISSED THE MECH. REVIEW. ***
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-07-18 Cont ID  
Sent By tgordon Date 2007-07-18 Time 13:55 Rev Time 0.30
Received By tgordon Date 2007-07-18 Time 13:55 Sent To P
Notes
2007-07-18 14:02:26*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 2) SEE YELLOW HIGH LIGHTS ON MECHANICAL PLANS SHOWING
 DUCTS (FLEX) THAT NEEDS TO BE SIZED.
  
 3) PLEASE SHOW ON MECHANICAL PLAN COMBUSTION AIR
 CALCULATIONS, PROVIDE COMBUSTION AIR IF NEEDED FOR GAS
 CLOTHES DRYER AND OR MAKE-UP AIR.
  
 4)ALL INFORMATION, DRAWINGS, MECHANICAL PLANS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 PRINTED NAME AND SIGNATURE OF THE PERSON RESPONSIBLE
 FOR THE DESIGN. PER FBC 104.2.1 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-11-05 Cont ID  
Sent By jleech Date 2007-11-05 Time 08:52 Rev Time 0.00
Received By jleech Date 2007-11-05 Time 08:52 Sent To B
Notes
2007-11-05 08:52:47RE-STAMP

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-10-03 Cont ID  
Sent By jleech Date 2007-10-03 Time 07:57 Rev Time 0.00
Received By jleech Date 2007-10-03 Time 07:57 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-07-26 Cont ID  
Sent By jleech Date 2007-07-26 Time 09:10 Rev Time 0.00
Received By jleech Date 2007-07-26 Time 09:10 Sent To  
Notes
2007-07-26 09:28:23DENIED;
 1. PAGE A4 WATER HEATER PIPING DIAGRAM, SHOW TYPE OF
 THERMAL EXPANSION CONTROL TO BE USED. SECTION 607.3.
 2. SANITARY RISER DIAGRAM;
 A) BIDET AND VEG. SINK SHOWN ON RISER DIAGRAM
 BUT NOT ON FLOOR PLAN.
 B) BAR SINK MISSING FROM RISER DIAGRAM, SHOWN
 ON FLOOR PLAN.
 C) SUMMER KITCHEN SINK TO DISCHARGE DOWN
 STREAM OF THE BATHROOM GROUP. SECTION 909.1
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 5 Status P Date 2008-07-18 Cont ID  
Sent By mcruz Date 2008-07-18 Time 12:47 Rev Time 0.00
Received By mcruz Date 2008-07-18 Time 12:46 Sent To  
Notes
2008-07-18 12:47:18LANDSCAPE PLAN APPROVED PER ROBERT KUSSNER, LANDSCAPE
 PLANNER.

Review Stop Z ZONING
Rev No 4 Status F Date 2008-07-15 Cont ID  
Sent By mcruz Date 2008-07-15 Time 16:27 Rev Time 0.00
Received By mcruz Date 2008-07-15 Time 16:27 Sent To  
Notes
2008-07-15 16:30:16**ZONING FAILED**
  
 1.PLEASE SUBMIT ALL RESPONSES IN WRITING.
  
 2.LANDSCAPE PLAN NOT DRAWN TO REQUIRED
 SPECIFICATIONS.REFER TO THE LANDSCAPE CODE IN THE
 ZONING AND LAND DEVELOPMENT REGULATIONS, SECTION
 94-442.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT OUR LANDSCAPE
 PLANNER, ROBERT KUSSNER, AT (561) 822-1462.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING DEPARTMENT

Review Stop Z ZONING
Rev No 3 Status P Date 2007-10-29 Cont ID  
Sent By choops Date 2007-10-29 Time 09:22 Rev Time 0.00
Received By choops Date 2007-10-29 Time 09:22 Sent To E
Notes
2007-10-29 09:24:09***APPROVED - RESUB #2***
  
 PROVISO:PALM TREES DO NOT COUNT AS SHADE, FLOWERING,
 OR FRUIT TREES.
  
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 2 Status F Date 2007-09-18 Cont ID  
Sent By choops Date 2007-09-18 Time 13:39 Rev Time 0.00
Received By choops Date 2007-09-18 Time 13:38 Sent To E
Notes
2007-09-18 13:43:57***FAILED - RESUB #1***
  
  
 REPEAT COMMENTS:
  
 1)ELEVATION DIMENSIONS TO BE MEASURED FROM GRADE.
  
 2)PROVIDE AN EASEMENT CONSENT FORM FROM THE CITY'S
 DEPARTMENT OF PUBLIC UTILITIES FOR THE PROPOSED PRIVACY
 WALL.
  
 3)LABEL ITEMS (ON SURVEYS AND SITE PLANS ETC...) TO
 BE UNDER SEPARATE PERMIT...POOL, POOL EQUIPMENT,
 DRIVEWAY.
  
 4)PROVIDE SQUARE FOOTAGE OF PROPOSED DRIVEWAY AND
 ALL WALKWAYS ***FROM FRONT PROPERTY LINE TO THE FRONT
 OF THE PRINCIPAL STRUCTURE (25' BACK FROM PROPERTY
 LINE)*** MAY NOT EXCEED 1500 SQ. FT.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-16 Cont ID  
Sent By choops Date 2007-07-16 Time 08:11 Rev Time 0.00
Received By choops Date 2007-07-16 Time 08:11 Sent To E
Notes
2007-07-16 08:26:29***FAILED***
  
  
 1)PLEASE PROVIDE SETBACK DIMENSIONS FROM A/C
 EQUIPMENT TO THE PROPERTY LINES.
  
 2)PROVIDE A LANDSCAPE PLAN SHOWING COMPLIANCE WITH
 SECTION 94-442 OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
 3)PLEASE PROVIDE ELEVATION DIMENSIONS FROM GRADE.
  
 4)INDICATE OVERHANG DIMENSION AT BAYWINDOW.
  
 5)INDICATE DISTANCE BAYWINDOW EXTENDS FROM PRINCIPAL
 STRUCTURE.
  
 6)GARAGE BAY WINDOW SECTION SHOWS IT NOT SUPPORTED
 BY THE GROUND, THE ELEVATIONS DO.
  
 7)ELEVATIONS OF PRIVACY WALL TO BE PROVIDED.ALSO,
 PLEASE PROVIDE AN EASEMENT CONSENT FORM FROM THE CITY
 OF WEST PALM BEACH DEPARTMENT OF PUBLIC UTILITIES.
  
 8)SPECIFY ANY ITEMS TO BE ON SEPARATE PERMIT (ON
 SITE PLAN)SUCH AS POOL EQUIPMENT, ETC...
  
 9)IF DRIVEWAY IS TO BE INCLUDED ON THIS PERMIT,
 PLEASE PROVIDE DIMENSIONS AND SQUARE FOOTAGE OF
 PROPOSED DRIVEWAY.IF NOT TO BE INCLUDED SEE COMMENT
 8).
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720