| Plan Review Stops For Permit 07070279 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-10-30 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-10-30 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2007-10-30 07:36:56 | BUILDING PROVISO | | | | | | THE GARAGE DOOR LOCATED WITHIN 10 FEET OF THE GENERATOR | | | IS REQUIRED TO BE ENCLOSED WITH GLASS BLOCK PER PERMIT | | | # 07100033. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-08-30 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-08-30 |
Time |
18:53 |
Sent To |
|
|
| Notes |
| 2007-08-30 19:09:02 | 2004 FBC | | | INSTALL RESIDENTIAL GENERATOR | | | 2ND REVIEW | | | | | | DENIED BY BUILDING | | | | | | | | | | | | 1)GENERATOR SLAB & ANCHOR REQUIREMENT | | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | | PLUS PROVIDE PLANS WITH THE INFORMATION | | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | | THE DEVICE REQUIRES WITHOUT LOAD | | | REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BE USED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: | | | 104.2.1* ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | PLANS MUST SHOW THAT THE GENERATOR IS ADEQUATELY | | | ANCHORED TO RESIST OVERTURNING, UPLIFT AND SLIDING AS | | | REQUIRED BY FBC 1609.1.3. | | | | | | | | | 2) A SEPARATE PERMIT IS REQURED TO INSTALL THE GLASS | | | BLOCK AND THE WORK WILL HAVE TO BE COMPLETED AND | | | APPROVED BY THE CITY BUILDING DEPARTMENT BEFORE THE | | | GENERATOR PERMIT CAN BE ISSUED. | | | | | | 3) ADDRESS REVIEW COMMENTS OF OTHER TRADES. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-08-01 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-08-01 |
Time |
07:43 |
Sent To |
M |
|
| Notes |
| 2007-08-01 08:53:59 | DENIED BY BUILDING | | | | | | 1)GENERATOR SLAB & ANCHOR REQUIREMENT | | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | | PLUS PROVIDE PLANS WITH THE INFORMATION | | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | | THE DEVICE REQUIRES WITHOUT LOAD | | | REDUCTION. | | | SECOND, PROVIDE INFORMATION ON THE | | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | | WILL BEUSED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: | | | 104.2.1* ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | | PERSON RESPONSIBLE FOR THE DESIGN. | | | | | | 2) PROVIDE PLANS ENOUGH TO VERIFY LOCATION | | | OF GENERATOR VERSES BUILDING OPENINGS | | | WINDOWS, DOORS OR SOFFIT TYPE VENTS, | | | ETC. | | | - PER 2004 FBC, FUEL GAS - POWERED EQUIPMENT | | | PERMANENTLY INSTALLED EQUIPMENT POWERED BY INTERNAL | | | COMBUSTION ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS AND NFPA | | | 37.NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: 4.1.4ENGINES | | | (GENERATORS) LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT | | | FROM OPENINGS IN WALLS & AT LEAST 5 FT FROM STRUCTURES | | | HAVING COMBUSTIBLE WALLS.A MINIMUM CLEARANCE IS NOT | | | REQUIRED WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF | | | ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, | | | AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. INFORMATIVE: A.8.2.3.1 | | | EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER STRUCTURES | | | OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO THE VENTILATION | | | INTAKES. | | | 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS | | | LOCATED BELOW AN ADJACENT ROOF STRUCTURE, THE | | | TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF | | | STRUCTURE. | | | PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL | | | EQUIPMENT TO ENCROACH 4 FT INTO THE REQUIRED SETBACK, | | | GENERATORS SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED | | | CLEARANCES TO THE ADJACENT PROPERTY STRUCTURES, I.E. | | | FENCE, BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | FOLLOW MANUFACTURER'S RECOMMENDED CLEARANCES | | | AROUND EQUIPMENT FOR SERVICING,AND PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS AT THE JOBSITE | | | FOR THE FIELD INSPECTOR. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-26 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-26 |
Time |
06:49 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-29 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-29 |
Time |
09:42 |
Sent To |
M |
|
| Notes |
| 2007-08-29 10:01:53 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | SAME COMMENT AS PREVIOUS REVIEW, RESPOND IN WRITING AS | | | I CANNOT FIND THE REQUIRED INFORMATION IN THE PACKAGE. | | | | | | 1} PROVIDE MANUFACTURERS SPECIFICATIONS | | | INDICATING RECOMMENDED SETBACKS FOR THE GENERATOR. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-16 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-16 |
Time |
08:30 |
Sent To |
M |
|
| Notes |
| 2007-07-16 09:20:52 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | NOTE: ALL PERMIT APPLICATIONS MUST BE SUBMITTED | | | TOGETHER TO EXPEDITE THE REVIEW PROCESS. | | | | | | 1} PROVIDE MANUFACTURERS SPECIFICATIONS | | | INDICATING RECOMMENDED SETBACKS FOR THE GENERATOR. | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
2 |
Status |
P |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-30 |
Time |
07:57 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-10-30 |
Time |
07:57 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
FUEL |
DIESEL GENERATOR |
| Rev No |
1 |
Status |
F |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-01 |
Time |
09:18 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-08-01 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2007-08-01 09:18:56 | SEE MECHANICAL REVIEW. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-30 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-07-30 |
Time |
14:35 |
Sent To |
B |
|
| Notes |
| 2007-07-30 14:37:36 | NOTE: GENERATOR IS DIESEL FUEL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-22 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-22 |
Time |
13:19 |
Sent To |
Z |
|
| Notes |
| 2007-10-22 13:19:17 | TO "Z" BOX/RESUB--NEW SHEETS FOR "Z" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-23 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-23 |
Time |
16:56 |
Sent To |
E |
|
| Notes |
| 2007-08-23 16:56:50 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-08-01 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-07-11 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2007-07-11 14:08:50 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-29 |
Time |
16:24 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-10-29 |
Time |
12:04 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-30 |
Time |
09:02 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2007-08-30 |
Time |
09:02 |
Sent To |
B |
|
| Notes |
| 2007-08-30 09:53:15 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA | | | ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS). | | | | | | *** DENIED *** | | | 1) AS REQUESTED IN LAST REVIEW 7-20-07. PLEASE SUBMIT | | | COMPLETE DETAILED MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AND SPECIFICATIONS FOR DIESEL GENERATOR | | | AND FUEL TANK (MUST SHOW FUEL TANK CAPACITY). | | | | | | 2) PLAN SHOWS THE GENERATOR NEXT TO A DOOR, SEE NFPA | | | 37. A PERMIT WILL BE REQUIRED AND THE DOOR WILL NEED TO | | | BE CLOSED OFF BEFORE THE GENERATOR PERMIT CAN BE | | | ISSUED. | | | | | | 3)INFORMATION MISSING IN TITLE BLOCK FOR ARCHITECT | | | (PRINTED NAME OF PERSON SEALING PLANS) SEE FAC | | | 61G1-16.004 TITLE BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. ("JOB ADDRESS" | | | SEE CITY WPB AMEND. 106.1.1). | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | | | | 4) THE WORKERS COMP. EXEMPT CARD SUBMITTED FOR KARL | | | SCHIBINGER, EXEMPTION IS FOR SALES ONLY THE PERMIT | | | APPLICATION IS FOR THE INSTALLATION OF A GENERATOR, | | | PLEASE CORRECT. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: 4.1.4ENGINES | | | (GENERATORS) LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT | | | FROM OPENINGS IN WALLS & AT LEAST 5 FT FROM STRUCTURES | | | HAVING COMBUSTIBLE WALLS.A MINIMUM CLEARANCE IS NOT | | | REQUIRED WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF | | | ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, | | | AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. INFORMATIVE: A.8.2.3.1 | | | EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER STRUCTURES | | | OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO THE VENTILATION | | | INTAKES. | | | 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS | | | LOCATED BELOW AN ADJACENT ROOF STRUCTURE, THE | | | TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF | | | STRUCTURE. | | | PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL | | | EQUIPMENT TO ENCROACH 4 FT INTO THE REQUIRED SETBACK, | | | GENERATORS SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED | | | CLEARANCES TO THE ADJACENT PROPERTY STRUCTURES, I.E. | | | FENCE, BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | FOLLOW MANUFACTURER'S RECOMMENDED CLEARANCES | | | AROUND EQUIPMENT FOR SERVICING,AND PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS AT THE JOBSITE | | | FOR THE FIELD INSPECTOR. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-17 |
Time |
09:46 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-07-17 |
Time |
09:46 |
Sent To |
P |
|
| Notes |
| 2007-07-17 09:50:29 | *** DENIED *** | | | 1) PLEASE SUBMIT COMPLETE DETAILED MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS AND SPECIFICATIONS FOR DIESEL | | | GENERATOR AND FUEL TANK. | | | | | | 2) PLAN SHOWS THE GENERATOR NEXT TO A GARAGE DOOR, SEE | | | NFPA 37, PLEASE CORRECT. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | | COMBUSTION ENGINES & GAS TURBINES: 4.1.4ENGINES | | | (GENERATORS) LOCATED OUTDOORS SHALL BE MINIMUM OF 5 FT | | | FROM OPENINGS IN WALLS & AT LEAST 5 FT FROM STRUCTURES | | | HAVING COMBUSTIBLE WALLS.A MINIMUM CLEARANCE IS NOT | | | REQUIRED WHEN (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | | RESISTANCE RATING OF 1 HOUR OR (2) THE WEATHERPROOF | | | ENCLOSURE IS CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, | | | AND IT HAS BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. INFORMATIVE: A.8.2.3.1 | | | EXHAUST SYSTEMS SHOULD NOT TERMINATE UNDER STRUCTURES | | | OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO THE VENTILATION | | | INTAKES. | | | 2004 FMC 804.3.5 #3, WHERE THE TERMINATION IS | | | LOCATED BELOW AN ADJACENT ROOF STRUCTURE, THE | | | TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE ROOF | | | STRUCTURE. | | | PLEASE NOTE, WHILE ZONING ALLOWS MECHANICAL | | | EQUIPMENT TO ENCROACH 4 FT INTO THE REQUIRED SETBACK, | | | GENERATORS SHALL MAINTAIN THE REQUIRED ABOVE MENTIONED | | | CLEARANCES TO THE ADJACENT PROPERTY STRUCTURES, I.E. | | | FENCE, BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | FOLLOW MANUFACTURER'S RECOMMENDED CLEARANCES | | | AROUND EQUIPMENT FOR SERVICING,AND PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS AT THE JOBSITE | | | FOR THE FIELD INSPECTOR. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-30 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-07-30 |
Time |
14:40 |
Sent To |
G |
|
| Notes |
| 2007-07-30 14:41:34 | NOTE: GENERATOR IS DIESEL FUEL. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-25 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-10-25 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-10-25 |
Time |
11:02 |
Sent To |
E |
|
| Notes |
| 2007-10-25 11:02:59 | ***APPROVED - RESUB #2*** | | | | | | SENT TO "E" - BT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-12 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-12 |
Time |
13:16 |
Sent To |
E |
|
| Notes |
|
|