Plan Review Details - Permit 07070210
| Plan Review Stops For Permit 07070210 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-08-27 |
|
|
Cont ID |
` |
| Sent By |
shill |
Date |
2007-08-27 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-27 |
Time |
18:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-22 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-22 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2007-08-22 14:07:02 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT.NOTE THAT THE ANCHOR SPACING ON PAGE 2 | | | WAS BLANK.ALSO, THE SHUTTER CONNECTION MOUNTING TYPE | | | SHOULD CORRELATE WITH THE DETAIL MARKERS ON THE ANCHOR | | | SCHEDULE; IN THIS CASE, A THROUGH L.IT APPEARS THAT | | | YOU ARE USING A (12). | | | | | | 2ND REVIEW - YOU ARE SPECIFYING A 3" EDGE DISTANCE. | | | YOU HAVE WRITTEN "HV 12" ON THE INSTALLATION SCHEDULE. | | | THE ANCHOR SCHEDULE ON THE PRODUCT APPROVAL USES A | | | THROUGH L FOR SHUTTER CONNECTION MOUNTING TYPES.YOU | | | HAVE CIRCLED BOTH A AND H ON THE PRODUCT APPROVAL.3" | | | EDGE DISTANCE REQUIRES A FACTOR OF .83, SEE SHEET 14 OF | | | THE PRODUCT APPROVAL.TAPCON, 8' SPAN, 3" EDGE | | | DISTANCE, CONNECTION H REQUIRES 8.5 X .83 SPACING, YOUR | | | INSTALLATION SCHEDULE STATES 8". | | | | | | PLEASE REVISE INSTALLATION SCHEDULE. | | | | | | 3RD REVIEW - THE ANCHOR SPACING WAS REVISED BUT THE | | | SHUTTER CONNECTION MOUNTING TYPE STILL STATES "HV12". | | | THIS SHOULD CORRELATE WITH THE ANCHOR SCHEDULE, A | | | THROUGH L.YOU'VE CIRCLED INFORMATION ON THE CHART FOR | | | A AND H, ARE THESE THE CONNECTION TYPES YOU ARE USING? | | | PLEASE INCLUDE THIS INFORMATION AS REQUESTED.REVISE | | | INSTALLATION SCHEDULE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-15 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-15 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2007-08-15 07:52:19 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | FROM PREVIOUS LIST: | | | | | | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT.NOTE THAT THE ANCHOR SPACING ON PAGE 2 | | | WAS BLANK.ALSO, THE SHUTTER CONNECTION MOUNTING TYPE | | | SHOULD CORRELATE WITH THE DETAIL MARKERS ON THE ANCHOR | | | SCHEDULE; IN THIS CASE, A THROUGH L.IT APPEARS THAT | | | YOU ARE USING A (12). | | | | | | YOU ARE SPECIFYING A 3" EDGE DISTANCE.YOU HAVE | | | WRITTEN "HV 12" ON THE INSTALLATION SCHEDULE.THE | | | ANCHOR SCHEDULE ON THE PRODUCT APPROVAL USES A THROUGH | | | L FOR SHUTTER CONNECTION MOUNTING TYPES.YOU HAVE | | | CIRCLED BOTH A AND H ON THE PRODUCT APPROVAL.3" EDGE | | | DISTANCE REQUIRES A FACTOR OF .83, SEE SHEET 14 OF THE | | | PRODUCT APPROVAL.TAPCON, 8' SPAN, 3" EDGE DISTANCE, | | | CONNECTION H REQUIRES 8.5 X .83 SPACING, YOUR | | | INSTALLATION SCHEDULE STATES 8". | | | | | | PLEASE REVISE INSTALLATION SCHEDULE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-01 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-01 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2007-08-01 15:52:10 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ARCHITECT | | | OR ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15, FAC61G1 16. | | | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT.NOTE THAT THE ANCHOR SPACING ON PAGE 2 | | | WAS BLANK.ALSO, THE SHUTTER CONNECTION MOUNTING TYPE | | | SHOULD CORRELATE WITH THE DETAIL MARKERS ON THE ANCHOR | | | SCHEDULE; IN THIS CASE, A THROUGH L.IT APPEARS THAT | | | YOU ARE USING A (12). | | | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | _XX_5.TWO COMPLETE COLLATED SETS OF DOCUMENTS | | | REQUIRED FOR PERMITTING.ONLY ONE INSTALLATION | | | SCHEDULE WAS SUBMITTED. | | | | | | ____6.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | | ABOVE. | | | | | | _XX_8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | | R301.2.1.4.(DESIGN PRESSURE OF -40 IS TOO LOW FOR | | | EXPOSURE C.) |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-16 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-16 |
Time |
10:06 |
Sent To |
B |
|
| Notes |
| 2007-08-16 10:07:19 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-08-07 |
Time |
17:53 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-08-07 |
Time |
17:52 |
Sent To |
B |
|
| Notes |
| 2007-08-07 17:53:09 | SENT TO SAMANTHA HILL'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-01 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-10 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2007-07-10 10:11:41 | TO "MISC" BOX#1 |
|
|
|