| Plan Review Stops For Permit 07070166 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-09-17 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-09-17 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2007-09-17 16:49:52 | PLANS SUBMITTED BY MISTAKE , APPLICATION SHOULD HAVE | | | BEEN APPROVED AS A $50 FINAL INSPECTION ONLY PERMIT. | | | LUIS MARTINEZ, KEN CONRAD, ROBERT BROWN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-08-07 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-08-07 |
Time |
12:57 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 13:12:31 | SWIMMING POOL BUILDING REVIEW FIRST CHECKLIST (REVIEW | | | DONE UNDER FBC 2004 WITH 2006 REVISIONS): | | | | | | 1- NEED TO SUBMIT TWO COMPLETE AND EQUAL SETS OF | | | DRAWINGS AS REQUIRED BY SEC. 106.1 CITY AMENDMENTS TO | | | FBC 2004.PLANS SUBMITTED DON'T MATCH, WERE SIGNED AND | | | SEALED ON DIFFERENT DATES AND ONE OF THEM HAS | | | HANDWRITTENREVISIONS.PLANS NEED TO MATCH AND | | | HANDWRITTEN INFORMATION IS NOT ALLOWED. ANY CHANGES | | | SHALL BE DONE ON ORIGINAL DRAWINGS. | | | | | | 2- SHEET 1 OF 1:POOL WAS DESIGNED USING THE 2001 | | | FLORIDA BUILDING CODE.CURRENT CODE IS THE FBC 2004 | | | AND 2004 FLORIDA RESIDENTIAL CODE.THIS IS A | | | RESIDENTIAL POOL, THEREFORE CORRECT CODE TO USEIS | | | CHAPTER 41 OF OF2004 FLORIDA RESIDENTIAL CODE. | | | ENGINEERING DESIGN SHALL BE DONE AS PER SEC. R4101.6. | | | REVISE ALL NOTES ON SHEET 1 THAT REFER TO FBC 2001 OR | | | SECTION 424 OF FLORIDA BUILDING CODE OF 2001. | | | | | | 3- POOL SPECIFICATIONS ON SHEET 1 DON'T MATCH DRAWINGS. | | | EG: SEE POOL DIMENSIONS AND VOLUME. REVISE AS REQUIRED | | | TO MATCH. | | | | | | 4- ENGINEER NEEDS TO USE CURRENT SEAL THAT READS | | | "LICENSE" INSTEAD OF "CERTIFICATE" AS REQUIRED BY THE | | | BOARD OF ENGINEERS. | | | | | | 5- CLEARLY IDENTIFY WHICH RESIDENTIAL SWIMMING BARRIER | | | IS GOING TO BE USED AS REQUIRED BY SEC. R4101.17 OF | | | 2004 FLORIDA RESIDENTIAL CODE. | | | NOTE: KEEP IN MIND THAT ONE BARRIER IS FROM THE HOUSE | | | TO THE POOL AND ANOTHER BARRIER REQUIRED IS FROM THE | | | OUTSIDE OF THE HOUSE. EG: ENTRANCE TO POOL FROM OUTSIDE | | | GATES. | | | | | | 6-POOL VALUE DECLARED ON THE PERMIT APPLICATION WAS | | | UPDATED TO $45,718, WHICH WAS THE CALCULATED VALUE USED | | | ON PREVIOUS PERMIT BEFORE IT WAS EXPIRED. OWES $418.50 | | | AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-09-17 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-09-17 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2007-09-17 16:52:21 | REVIEWS ARE NOT REQUIRED , SEE NOTES ON #07070166 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-11 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-10 |
Time |
16:43 |
Sent To |
P |
|
| Notes |
| 2007-07-11 14:20:04 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | | | TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR REVIEW | | | PER 106.1 FBC AS AMENDED. THE SETS SUBMITTED DO NOT | | | MATCH. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-23 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-07-23 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2007-07-23 16:39:27 | NOTE: PLEASE REFERENCE PLUMBING COMMENTS ON POOL | | | HEATERS. | | | | | | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-08-07 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-07-09 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2007-07-09 13:22:20 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-09-17 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-09-17 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2007-09-17 16:56:42 | REVIEW IS NOT REQUIRED , SEE NOTES FROM # 07070166 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-23 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-07-23 |
Time |
16:22 |
Sent To |
G |
|
| Notes |
| 2007-07-23 16:34:54 | DENIED | | | REFERENCE: | | | **FBC-2004 SECTION 424.2 OR R4101 SWIMMING POOLS. | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | 1. TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR | | | REVIEW PER FBC-2004 CHAPTER 1, SECTION 106.1. THE | | | SUBMITTED SETS DO NOT MATCH. PLEASE CORRELATE PRINTS ON | | | THE RESUBMITTAL. | | | | | | 2. FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | | | | 3. FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-10 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-10 |
Time |
14:59 |
Sent To |
E |
|
| Notes |
| 2007-07-10 15:01:13 | ***APPROVED - REFERENCE EXPIRED PERMIT #04050411 |
|
|