Plan Review Details - Permit 07070074
Plan Review Stops For Permit 07070074
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-30 Cont ID  
Sent By rbrown Date 2007-08-30 Time 09:43 Rev Time 0.00
Received By rbrown Date 2007-08-30 Time 09:43 Sent To  
Notes
2007-08-30 10:08:17BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6652
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2004 (WITH 2007
 AMENDMENTS)
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
 F.S.= FLORIDA (STATE) STATUTE
  
 1) FBC 1609.1SHUTTER ATTACHMENT.THE SUBMITTED
 SHUTTER INSTALLATION SCHEDULE STATES THAT THE ANCHORS
 WILL BE 1/4" DIA. X 1-1/4" LONG ELCO/BUILDIEX HEX HEAD
 MAXISET TAPCON.THAT LENGTH WILL NOT PROVIDE ENOUGH
 EMBEDMENT.PAGE 14 OF THE SUBMITTED AMERICAN SHUTTER
 SYSTEMS PRODUCT APPROVAL (FL 7279-R1) STATES THAT
 1-3/4" EMBEDMENT IS REQUIRED FOR POURED CONCRETE
 SUBSTRATE AND 1-1/4" EMBEDMENT IS REQUIRED FOR CONCRETE
 BLOCK SUBSTRATE. EITHER PROVIDE LONGER ANCHORS OR
 SPECIFY ONE OF THE OTHER ANCHOR TYPE/SIZE OPTIONS
 STATED IN THE PRODUCT APPROVAL.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE:
 (561) 805 6652ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-07-10 Cont ID  
Sent By pschmitz Date 2007-07-10 Time 07:46 Rev Time 0.00
Received By pschmitz Date 2007-07-10 Time 07:46 Sent To PC
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-10 Cont ID  
Sent By pschmitz Date 2007-07-10 Time 07:47 Rev Time 0.00
Received By pschmitz Date 2007-07-05 Time 16:32 Sent To  
Notes
2007-07-05 16:32:19TO "MISC" BOX#1