| Plan Review Stops For Permit 07070042 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2008-01-17 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2008-01-17 |
Time |
16:16 |
Sent To |
PC |
|
| Notes |
| 2008-01-17 16:19:19 | | | | | | | PASSED | | | | | | REVISION FOR HELICAL PILES AND FOUNDATION | | | MODIFICATIONS, THREE PAGES SHEET #'S 7, 7A AND 8 | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-27 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-10-27 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-10-27 |
Time |
08:56 |
Sent To |
PC |
|
| Notes |
| 2007-10-27 09:03:38 | | | | | | | PASSED | | | | | | 1)RAS 117 CALCULATIONS ARE INCORRECTLY BASED ON A -45 | | | PSF, ALL NON INSULATED ROOFING ASSEMBLIES THAT ARE -45 | | | PSF ARE LIMITATION #9 WHICH DO NOT ALLOW FOR ENHANCED | | | FASTENING TO BE CALCULATED SEE PAGE 34 OF NOA THE | | | ASSEMBLY THAT YOU ARE USING, BASED ON SHEET 6 OF THE | | | DRAWING IS ON PAGE 33 OF THE NOA AND HAS A DESIGN | | | PRESSURE OF -52.5 WITH THE 6" O/C PATTERN THAT YOU USED | | | IN YOUR CALCULATIONS | | | | | | *****PLEASE SUBMIT NEW CALCULATIONS TO THE INSPECTOR AT | | | TIME OF INSPECTION***** | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-06 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-10-06 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-10-06 |
Time |
08:54 |
Sent To |
PC |
|
| Notes |
| 2007-10-06 09:46:23 | | | | | | | DENIED | | | | | | 1)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | | AND OWNER/AGENT PRIOR TO SUBMITTAL | | | ****NOTE THAT OWNER/AGENT MUST SIGN AND DATE AS WELLAS | | | PREPARER, ALSO CONFIRM THAT R-VALUE FOR CEILING/DECK | | | AREA IS INCLUDED IN CALCULATIONS EITHER AS RAISED WOOD | | | FLOOR OR ADDED TO ATTIC AREA SQUARE FOOTAGE**** | | | | | | 2)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | ****NOTE THIS IS A REQUIREMENT OF THIS | | | JURISDICTION**** | | | | | | 3)PROVIDE CORRECT FLORIDA PRODUCT APPROVAL | | | INFORMATION FOR THE SIMPSON CONNECTORS, PLEASE SEE THE | | | 2 COPIES OF THE FLORIDA INDEXTHAT ARE ATTACHED AND | | | HIGHLITE THE APPROPRIATE CONNECTORS | | | | | | 4)PROVIDE CORRECT FLORIDA PRODUCT APPROVAL | | | INFORMATION FOR THE PEACHTREE SGD, PLEASE USE THE | | | FLORIDA STATE LINK ON THE PAGE FOR THE SGD (FL 9141) TO | | | DOWNLOAD THE CORRECT COMPLIANCE REPORT | | | | | | 5)PROVIDE PRODUCT APPROVALS FOR MULLIONS THAT WILL BE | | | USED TO TIE DOUBLE AND TRIPLE SET WINDOWS | | | | | | 6)PROVIDE PRODUCT APPROVALS FOR ALL ENTRY DOORS | | | INCLUDING FRONT DOOR WITH SIDELITE | | | | | | 7)PROVIDE DETAIL THAT SHOWS THE ATTACHMENT OF | | | GUARDRAIL TO PROVIDE FOR THE CONCENTRATED LOADS | | | REQUIRED BY 1607.7.1.1 FBC AND HOW THE WATERTIGHT | | | CONSTRUCTION WHERE PENETRATING ROOFING MATERIALS | | | | | | 8)STATE THE PERIMETER AND CORNER DESIGN PRESSURE FOR | | | THE FLAT DECK AREA THAT IS TO USE ROOFING PRODUCT IF | | | THEY EXCEED THE DESIGN PRESSURE LIMIT OF THE PRODUCT | | | APPROVAL PROVIDE CALCULATIONS PER RAS 117 (SEE | | | LIMITATION #7 ON LAST PAGE OF THE PRODUCT APPROVAL) FOR | | | ENHANCED FASTENING | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-07-19 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-07-19 |
Time |
16:15 |
Sent To |
PC |
|
| Notes |
| 2007-07-17 18:47:40 | | | | | | | DENIED | | | | | | 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | | AMENDMENTS PER 106.1.1 FBC* | | | | | | 2)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | | DRAWINGS | | | | | | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | | ADDED TO THE PERMIT APPLICATION FEES | | | | | | NOTE: FEES ARE DUE IN THE AMOUNT OF $ 29.62FOR STATE | | | RADON FEES THIS AMOUNT IS REQUIRED TO BE PAID PRIOR TO | | | FURTHER PLAN REVIEW | | | | | | 4)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561) 233-5025 FOR MORE | | | INFORMATION. | | | | | | 5)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN | | | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES. | | | | | | 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | | AND OWNER/AGENT PRIOR | | | TO SUBMITTAL | | | | | | 7)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE | | | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. | | | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | | | NOTE: PRODUCT APPROVALS ARE REQUIRED FOR CASTCRETE | | | LINTELS, GARAGE SECTIONAL DOOR, ALL STRUCTURAL | | | STRAPS/TIES THAT WILL BE USED | | | ( PROVIDE EITHER A COMPLETE CONNECTOR SCHEDULE WITH THE | | | FLORIDA STATEWIDE PRODUCT APPROVAL NUMBER LISTED OR THE | | | MANUFACTURERS FLORIDA INDEX WITH THE APPROPRIATE | | | CONNECTORS MARKED.) | | | | | | 8)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | 9)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | | STATE PRODUCT APPROVAL COVER | | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | | SUBMITTED APPLICATIONS WILL BE DENIED | | | | | | 10)SUBMIT ENGINEERED TRUSS DRAWINGS FOR FLOOR AND | | | ROOF TRUSSES THAT | | | COMPLY WITH R802.10.1 FBC WITH PERMIT | | | APPLICATION OR BEFORE INSTALLATION THAT | | | HAVE BEEN REVIEWED AND APPROVED BY THE | | | DESIGNER OF RECORD | | | | | | 11)SUBMIT SPIRAL STAIRCASEDRAWINGS THAT | | | COMPLY WITH R311.5 AND R311.5.8.1 FBC RES. WITH PERMIT | | | APPLICATION THAT HAVE BEEN REVIEWED AND APPROVED BY | | | THE | | | DESIGNER OF RECORD | | | | | | 12)PROVIDE SIZE OF ATTIC VENTILATION AND IT'S SPACING | | | TO SHOW COMPLIANCE WITH R806.2 FBC RES. (IF 20 SQ. FT. | | | IS REQUIRED THIS WILL REQUIRE APPROX. 60 VENTS OF | | | 4"X12") | | | | | | 13)NO SECTIONS WERE GIVEN OF THROUGH FRONT LIVING | | | ROOM/TERRACE/VERANDA AREAS PLEASE SHOW CONSTRUCTION OF | | | DECKS, AS UNCOVERED DECK IS SITUATED OVER LIVING SPACE | | | AND SHOW SOFFIT MATERIAL AT THESE LOCATIONS AND BACK | | | COVERED PATIO AREA | | | | | | 14)PROVIDE COMPLETED APPLICATION FOR LOCAL PRODUCT | | | APPROVAL FOR THE SLIDING GLASS DOORS. SEE ATTACHED | | | APPLICATION AND BE SURE ALL REQUIRED INFORMATION IS | | | PROVIDED PER CHECK LIST ON BACK. | | | | | | 15)STAIR HANDRAILS AND GUARDS SHALL REJECT A 4" | | | SPHERE PER R312.2 FBC RES. | | | | | | 16 )PROVIDE INFORMATION ON PLANS THAT STAIRS MEET ALL | | | THE REQUIREMENTS OF R315.1 - 315.5.5 FBC RES. | | | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | | AMENDMENTS | | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | | AMENDMENTS TO FBC | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | FBC RES. = FLORIDA BUILDING CODE | | | RESIDENTIAL 2004 W/2006 AMENDMENTS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-05-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-05-26 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-05-26 |
Time |
12:00 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-26 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-26 |
Time |
07:55 |
Sent To |
M |
|
| Notes |
| 2007-10-26 13:05:55 | | | | | | | REDLINED RECEPTALE IN BEDROOM AND STUDIO, UPPER, AND | | | BATH CIRCUIT ON SCHEDULE./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-09-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-24 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-24 |
Time |
08:51 |
Sent To |
M |
|
| Notes |
| 2007-09-24 10:50:13 | | | | | | | THESE ARE REPEAT COMMENTS FROM 7/10/07 REVIEW. | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | | FS, RESPECTIVELY. THIS COMMENT WAS NOT ADDRESSED.. | | | | | | 2} PER 110.9 AND 110.10: OBTAIN THE AVAILABLE FAULT | | | CURRENT AT THE UTILITY AND CALCULATE THE SAME AT THE | | | EQUIPMENT. INDICATE THE AIC RATING FOR THE EQUIPMENT IS | | | EQUAL TO OR GREATER THAN THE AVAILABLE FAULT. THE | | | CALCULATION GIVEN WAS ONLY AT THE TRANSFORMER, NOT AT | | | THE SERVICE EQUIPMENT, WHICH IS THE INFORMATION THE | | | CONTRACTOR NEEDS TO PURCHASE THE CORRECT EQUIPMENT. | | | | | | 5} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III, | | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. THE | | | CENTRAL HEAT, AND POOL HEATER TOOK A DEMAND AND WAS | | | THEN FIGURED INTO THE TOTAL LOAD AND ANOTHER DEMAND OF | | | 40% WAS TAKEN. | | | THE LOAD CALCULATION IS STILL INCORRECT. THE | | | CALCULATION APPEARS TO BE PARTLY FROM ARTICLE 220.83. | | | THE 65% DEMAND ON THE AHU'S, SHOULD BE 100%, SEE | | | 220.83(B). ALSO ONLY THE LARGEST OF THE A/C OR AHU LOAD | | | SHOULD BE IN THE CALCULATION, AGAIN SEE 220.83(B). THE | | | 40 PERCENT DEMAND TAKEN ON THAT LOAD IS IS NEVER | | | ALLOWED. IN THE CASE OF THE AHU'S A DOUBLE DEMAND WAS | | | TAKEN, 1ST THE 65% THEN 40% OF THAT. | | | | | | THIS IS A NEW COMMENT FOR THIS REVIEWDUE TO THE CHANGE | | | IN THE RISER DIAGRAM | | | | | | 1} LOCATE THE GUTTER SHOWN ON THE RISER, AT THE | | | PHYSICAL LOCATION ON THE PLAN | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-10 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-10 |
Time |
12:05 |
Sent To |
M |
|
| Notes |
| 2007-07-10 12:27:30 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | | FS, RESPECTIVELY. | | | | | | 2} PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 3} 230.31 SIZE AND RATING | | | (A) GENERAL SERVICE-LATERAL CONDUCTORS SHALL HAVE | | | SUFFICIENT AMPACITY TO CARRY THE CURRENT FOR THE LOAD | | | AS CALCULATED IN ACCORDANCE WITH ARTICLE 220 AND SHALL | | | HAVE ADEQUATE MECHANICAL STRENGTH. THE LOAD CALCULATION | | | @ 244 AMPS, EXCEEDS THE SERVICE SIZE OF 200 AMPS. THE | | | SERVICE MUST BE INCREASED. | | | | | | 4} PROVIDE A PANEL SCHEDULE PER 408.4. PLEASE SEE NEW | | | VERBAGE FOR 2005 NEC: "THE IDENTIFICATION SHALL INCLUDE | | | SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE | | | DISTINGUISHED FROM ALL OTHERS." ALL PANELS. | | | | | | 5} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III, | | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. THE | | | CENTRAL HEAT, AND POOL HEATER TOOK A DEMAND AND WAS | | | THEN FIGURED INTO THE TOTAL LOAD AND ANOTHER DEMAND OF | | | 40% WAS TAKEN. | | | | | | 6} THE POOL HEATER WAS CALCULATED @ 40%, INDICATE THE | | | ARTICLE FROM WHICH THAT DEMAND WAS ALLOWED. | | | | | | 7} PROVIDE A LEGEND FOR THE SYMBOLS USED FOR THE | | | ELECTRICAL PLANS. | | | | | | 8} THE CONDENSING UNITS ARE REQUIRED TO HAVE | | | DISCONNECTS PER 440.14, THE PLAN INDICATES JUNCTION | | | BOXES. PLEASE CLARIFY. | | | | | | 9} THE SPA MUST BE GFCI PROTECTED PER 680.43(A)(3). | | | INDICATE SAME ON PLAN. | | | | | | 10} THE WATER HEATER IN THE GARAGE IS SHOWN NEXT TO A | | | RECEPTACLE, AND THERE DOES NOT APPEAR TO BE A | | | DISCONNECT FOR THAT UNIT. SEE 422.16 REGARDING | | | "APPLIANCE IS INTENDED OR IDENTIFIED FOR FLEXIBLE CORD | | | CONNECTION". | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | . |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-11-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-12 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-12 |
Time |
11:07 |
Sent To |
M |
|
| Notes |
| 2008-11-12 11:08:11 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-01-11 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2008-01-11 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2008-01-11 |
Time |
17:07 |
Sent To |
B |
|
| Notes |
| 2008-01-11 17:07:51 | TO ADRIAN MORSES DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-24 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-24 |
Time |
12:17 |
Sent To |
E |
|
| Notes |
| 2007-10-24 12:18:26 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
10:45 |
Sent To |
Z |
|
| Notes |
| 2007-09-17 10:45:34 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-07-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-06 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2007-07-06 09:02:34 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-11-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-11-13 |
Time |
14:23 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2008-11-13 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2008-11-13 14:24:06 | REVISION TO MECH. PLANS 18 AND 19. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2008-11-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-11-12 |
Time |
15:36 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-11-12 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2008-11-12 16:11:43 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | REVISION TO MECHANICAL PLANS. | | | *** DENIED *** | | | | | | 1) THE FOLLOWING RETURN AIR DUCTS APPEAR TO BE UNDER | | | SIZED. 8" RETURN FLEX TO MASTER BEDROOM (AHU #2), 10" | | | RETURN FLEX TO THE LOFT (AHU #3), AND THE 7"X24" CHASE | | | FOR AHU #1. | | | | | | 2) SHOW THE SIZE OF THE DUCT (RIGID FIBROUS GLASS) FROM | | | AHU #1 TO THE 7"X24" CHASE, PER 2004 FBC/R M1601.1. | | | | | | 3) PLEASE SUBMIT MANUAL D CALCULATIONS FOR RESIDENTIAL | | | DUCT DESIGN (3 SYSTEMS), PER 2004 FBC/R M1601.1 AND FBC | | | 13-610.1.ABC.1. SEE ATTACHED COPY OF MANUAL D | | | RECOMMENDED VELOCITY. | | | | | | 4) PLEASE SUBMIT A BLOWER PERFORMANCE TABLE OR GRAPH | | | FOR EACH AHU, PER MANUAL D 5-1. | | | | | | 5) PLEASE SUBMIT THE PRODUCT AND PERFORMANCE DATA | | | SHEETS FOR THE FLEXIBLE DUCT BEING USED, PER 2004 FBC/R | | | M1601.4. | | | | | | NOTICE: 2004 FBC/R M1602.4 BALANCED RETURN AIR. | | | RESTRICTED RETURN AIR OCCURS IN BUILDINGS WHEN RETURNS | | | ARE LOCATED IN CENTRAL ZONES AND CLOSED INTERIOR DOORS | | | IMPEDE AIR FLOW TO THE RETURN GRILL OR WHEN CEILING | | | SPACES ARE USED AS RETURN PLENUMS AND FIRE WALLS | | | RESTRICT AIR MOVEMENT FROM ONE PORTION OF THE RETURN | | | PLENUM TO ANOTHER. PROVISIONS SHALL BE MADE IN | | | RESIDENTIAL BUILDINGS TO AVOID UNBALANCED AIR FLOWS AND | | | PRESSURE DIFFERENTIALS CAUSED BY RESTRICTED RETURN AIR. | | | PRESSURE DIFFERENTIALS ACROSS CLOSED DOORS WHERE | | | RETURNS ARE CENTRALLY LOCATED SHALL BE LIMITED TO 0.01 | | | INCH WC (2.5 PASCALS) OR LESS. PRESSURE DIFFERENTIALS | | | ACROSS FIRE WALLS IN CEILING SPACE PLENUMS SHALL BE | | | LIMITED TO 0.01 INCH WC (2.5 PASCALS) BY PROVIDING AIR | | | DUCT PATHWAYS OR AIR TRANSFER PATHWAYS FROM THE HIGH | | | PRESSURE ZONE TO THE LOW ZONE. | | | BALANCED RETURN AIR MAY ALSO BE ACHIEVED BY. | | | (A) TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE | | | RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS | | | SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR | | | HAVING AT LEAST AN UNRESTRICTED 1 INCH UNDERCUT TO | | | ACHIEVE PROPER RETURN AIR BALANCE. | | | (B) TRANSFER GRILLES SHALL USE 50 SQUARE INCHES (OF | | | GRILLE AREA) TO 100 CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND USING AN | | | UNRESTRICTED 1-INCH UNDERCUTTING OF DOORS TO ACHIEVE | | | PROPER RETURN AIR BALANCE | | | (C) HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET | | | THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR | | | EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY | | | ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE | | | SHALL BE INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-26 |
Time |
14:53 |
Rev Time |
0.40 |
| Received By |
tgordon |
Date |
2007-10-26 |
Time |
14:53 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-25 |
Time |
08:40 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-09-25 |
Time |
08:40 |
Sent To |
P |
|
| Notes |
| 2007-09-25 08:52:01 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW, ENERGY CALCULATIONS NEED TO | | | BE SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC | | | 13-600.3.ABC.2. | | | | | | 2) THE MECHANICAL PLANS PAGES 18 & 19 NEED THE PRINTED | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN, AND CONTRACTOR INFORMATION IF APPLICABLE ON | | | THEM, SEE W.P.B. AMEND. 106.1.3. | | | | | | 3) SHOW ON MECHANICAL PLANS THE ATTIC ACCESS FOR AHU | | | #2, SEE FBC/R M1305.1.3.2. | | | | | | 4) SHOW ON MECHANICAL PLAN ALL BATHROOM EXHAUST FANS | | | AND CFM'S, SEE ELECTRICAL PLAN AND FBC/R R303.3 | | | EXCEPT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-11 |
Time |
09:06 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-07-11 |
Time |
09:06 |
Sent To |
P |
|
| Notes |
| 2007-07-11 09:30:48 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600A-04R, | | | PLEASE CORRECT ALSO HAVE OWNER/AGENT SIGN REVISED | | | E-CAL'S. SEE 2004 FBC 13-600.3.A AND 13-600.3.ABC.2. | | | | | | 2) MECHANICAL PLANS NEED TO BE SEALED BY JOHN CRESWELL, | | | P.E. AS HIS NAME AND INFORMATION IS IN THE TITLE BLOCK, | | | SEE FAC 61G15-23.002. | | | | | | 3) NEED A/C EQUIPMENT LISTING ON MECHANICAL PLANS | | | SHOWING ALL PERTINENT INFORMATION (EQUIPMENT | | | MANUFACTURE, MODEL NUMBERS, SEER, TOTAL AND SENSIBLE | | | BTU'S, HEATER KW, ETC.). | | | | | | 4) PLEASE SHOW CFM'S AT ALL SUPPLY AIR GRILLS. | | | | | | 5) PLEASE SIZE THE SUPPLY AIR TRUNK LINE TO THE AIR | | | HANDLER IN THE GARAGE. | | | | | | 6) THE SECOND FLOOR NEEDS A RETURN FOR THE LOFT AND | | | OPEN AREA, SEE 2004 FBC/R M1604.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-01 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-01 |
Time |
09:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-07-17 |
Time |
07:15 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-17 |
Time |
07:15 |
Sent To |
B |
|
| Notes |
| 2007-07-17 07:20:51 | DENIED; | | | SANITARY RISER DIAGRAM NOT TO CODE; | | | A) 2ND FLOOR PLUMBING FIXTURES CANNOT DUMP | | | INTO THE VENT OF THE FIRST FLOOR FIXTURES. | | | B) 1/2 BATH, TOILET NOT VENTED AS DRAWN. | | | ONE SET OF PLANS MARKED IN RED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-20 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-20 |
Time |
08:50 |
Sent To |
E |
|
| Notes |
| 2007-09-20 08:55:04 | ***PASSED- RESUB #1*** | | | | | | PROVISO:POOL NOT INCLUDED UNDER THIS PERMIT, TO BE | | | UNDER SEPARATE PERMIT. | | | | | | NOTE:AS THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF | | | THE VALUE OF THE HOME, ALL LANDSCAPING SHALL BE BROUGHT | | | TO COMPLIANCE WITH SECTION 94-442 OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | NOTE:2ND FLOOR AREA ABOVE GARAGE TO MAINTAIN INTERIOR | | | ACCESS.NO SEPARATE DWELLING UNIT WILL BE PERMITTED. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-09 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-09 |
Time |
09:18 |
Sent To |
E |
|
| Notes |
| 2007-07-09 09:20:51 | ***FAILED*** | | | | | | | | | 1)PLEASE CLARIFY SCOPE OF WORK ON APPLICATION.REAR | | | PORCH TO BE ADDED, DRIVEWAY TO BE INCLUDED UNDER THIS | | | PERMIT?IF SO, INCLUDE ALL DIMENSIONS AND TOTAL SQUARE | | | FEET OF PROPOSED DRIVEWAY. | | | | | | 2)PROVIDE CHIMNEY DIMENSION THAT EXTENDS PAST THE | | | TOP OF THE ROOF. | | | | | | 3)SHOW ANY PROPOSED A/C EQUIPMENT ON SITE PLAN WITH | | | SETBACK DIMENSIONS TO THE PROPERTY LINES. | | | | | | 4)SHOW ALL OVERHANG DIMENSIONS. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|