Plan Review Details - Permit 07070001
Plan Review Stops For Permit 07070001
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-13 Cont ID  
Sent By kconrad Date 2007-08-13 Time 18:47 Rev Time 0.00
Received By kconrad Date 2007-08-13 Time 18:00 Sent To  
Notes
2007-08-13 18:33:01PROJECT: 611 FLAMINGO DRIVE
  
 PROJECT DETAIL: 8 ' X 11'FREE STANDING PERGOLA W/
 BARREL TILE ROOF/ OVER 225 SQ. FT. PAVERS
  
 PLAN REVIEW: 2004 FLORIDA BUILDING CODE W/2006
 REVISIONS
 WPB ADMINISTRATIVE CODE AMENDMENTS/2004
  
 STATUS: DENIED
  
  
 COMMENTS:
  
  
 1) THE SUBMITTED PLANS WERE GENERATED BY AFFORDABLE
 LANDSCAPING AND ARE REQUIRED TO BE SIGNED AND SEALED.
 THE CONTRACTOR WAS CHANGED TO AN OWNER BUILDER.
 THE OWNER BUILDER SHALL SUBMIT PLANS DRAWN BY A
 DESIGN PROFESSIONAL OR HIMSELF AND SHALL COMPLY WITH
 THE FOLLOWING:
  
 FBC * 106.1.2 QUALITY OF PLANS
 BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT.
  
 PLEASE SHOW DETAILS OF ALL CONNECTIONS. INDICATE AN
 ANCHORAGE SCHEDULE FOR CLARITY.
  
 2) INDICATE ROOF DESIGN LOADS.
  
 3) INDICATE WIND DESIGN DATA:
  
 603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
 2. WIND IMPORTANCE FACTOR, IW, AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M2) TO BE USED FOR THE SELECTION OF
 EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL.
  
 4) MISSING POST FOUNDATION DIMENSIONS. PLEASE SHOW
 DIMENSIONS OF FOUNDATIONS AND TYPE. REQUIRE CONCRETE
 SPECIFICATIONS.
  
 5) PLEASE SHOW ROOF FLASHING DETAIL TO EXISTING
 STRUCTURE.
  
 6) PLEASE SUBMIT THE STATE PRODUCT APPROVALS FOR THE
 ROOF TILE.
  
 7) INDICATE HEIGHT DIMENSIONS OF THE PERGOLA.
  
 8) INDICATE SPECIES AND GRADE OF LUMBER TO BE USED.
  
 9) PLEASE PROVIDE PAVER SPECIFICATIONS.
  
 10) PLEASE PROVIDE PRODUCT APPROVALS FOR THE
 ANCHORS/STRAPS INDICATED ON THE KEY AS PER THE
 FOLLOWING:
  
 9B-72.005 SCOPE.
 (1) PRODUCTS IN THE FOLLOWING CATEGORIES AS DEFINED BY
 SUBCATEGORIES OF SUBSECTION 9B-72.010(31), F.A.C.,
 SHALL BE AVAILABLE FOR
 APPROVAL BY THE COMMISSION PURSUANT TO RULE 9B-72.090,
 F.A.C., FOR USE IN THE STATE:
 (A) PANEL WALLS;
 (B) EXTERIOR DOORS;
 (C) ROOFING PRODUCTS;
 (D) SKYLIGHTS;
 (E) WINDOWS;
 (F) SHUTTERS; AND
 (G) STRUCTURAL COMPONENTS.
 (2) THIS RULE APPLIES TO APPROVAL OF PRODUCTS AND
 SYSTEMS, WHICH COMPRISE THE BUILDING ENVELOPE AND
 STRUCTURAL FRAME, FOR
 COMPLIANCE WITH THE STRUCTURAL REQUIREMENTS OF THE
 FLORIDA BUILDING CODE.
 SPECIFIC AUTHORITY 553.842(1) FS. LAW IMPLEMENTED
 553.842(5) FS. HISTORY?NEW 11-22-06.
  
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 805.6666
 E-MAIL: KCONRAD@ WPB.ORG

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-07-02 Cont ID  
Sent By swurafti Date 2007-07-02 Time 08:33 Rev Time 0.00
Received By swurafti Date 2007-07-02 Time 08:33 Sent To  
Notes
2007-07-02 08:33:37HISTORIC APPROVED BY JPAPA

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-13 Cont ID  
Sent By kconrad Date 2007-08-13 Time 18:47 Rev Time 0.00
Received By kconrad Date 2007-07-05 Time 08:31 Sent To  
Notes
2007-07-05 08:33:06TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2007-07-05 Cont ID  
Sent By choops Date 2007-07-05 Time 13:52 Rev Time 0.00
Received By choops Date 2007-07-05 Time 13:52 Sent To B
Notes
***NONE***