Plan Review Details - Permit 07061032
Plan Review Stops For Permit 07061032
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-08-20 Cont ID  
Sent By shill Date 2007-08-20 Time 08:46 Rev Time 0.00
Received By shill Date 2007-08-20 Time 08:46 Sent To  
Notes
2007-08-20 08:49:37****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)SHUTTER MOUNTING CONNECTION TYPE SHOULD REFER TO A
 THROUGH L TO CORRELATE WITH THE ANCHOR SCHEDULE ON THE
 PRODUCT APPROVAL.
  
 2.)YOU'VE HIGHLIGHTED A, D, G, H CONNECTION TYPES ON
 THE PRODUCT APPROVAL.A AND D REQUIRE CONCRETE
 SUBSTRATE.I CANNOT READ THE SUBSTRATE; APPEARS TO
 STATE CONCRETE, LOCKING RRD IN THE CENTER BOLD COLUMN.
 PLEASE CLARIFY SUBSTRATE.
  
 3.)YOU'VE HIGHLIGHED THE .78 FACTOR REQUIRED FOR 3"
 EDGE DISTANCE BUT HAVE NOT APPLIED THIS FACTOR TO THE
 HIGHLIGHTED ANCHOR SPACING ON THE SCHEDULE.PLEASE
 CAREFULLY READ THIS SECTION OF THE PRODUCT APPROVAL AND
 REVISE THE INSTALLATION SCHEDULE ACCORDINGLY.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-07-30 Cont ID  
Sent By shill Date 2007-07-30 Time 09:21 Rev Time 0.00
Received By shill Date 2007-07-30 Time 09:21 Sent To  
Notes
2007-07-30 09:22:09****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)THE INSTALLATION SCHEDULE IS INCOMPLETE.SECOND
 REQUEST.THIS IS REQUIRED FOR PERMITTING, SEE BUILDING
 OFFICIAL'S POLICY (AVAILABLE ONLINE OR IN THE LOBBY).
 CODE COMPLIANCE CANNOT BE DETERMINED DUE TO
 INSUFFICIENT INFORMATION.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-13 Cont ID  
Sent By shill Date 2007-07-13 Time 17:51 Rev Time 0.00
Received By shill Date 2007-07-13 Time 17:51 Sent To  
Notes
2007-07-13 17:52:45****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.THE FORM INCLUDED WAS INCOMPLETE.
  
 ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____5.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 _XX_6.TWO SETS OF PERMIT DOCUMENTS REQUIRED.ONLY
 ONE INSTALLATION SCHEDULE WAS IN THE PACKAGE.
  
 _XX_7.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3
 ABOVE.
  
 ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-08 Cont ID  
Sent By mmiller Date 2007-08-08 Time 18:13 Rev Time 0.00
Received By mmiller Date 2007-08-08 Time 18:13 Sent To B
Notes
2007-08-08 18:13:27SENT TO SAMANTHA HILL'S DESK MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-20 Cont ID  
Sent By adarroug Date 2007-07-20 Time 15:43 Rev Time 0.00
Received By adarroug Date 2007-07-20 Time 15:43 Sent To B
Notes
2007-07-20 15:44:04TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-13 Cont ID  
Sent By shill Date 2007-07-13 Time 17:52 Rev Time 0.00
Received By shill Date 2007-07-03 Time 08:37 Sent To  
Notes
2007-07-03 08:39:18TO "MISC" BOX#1