Plan Review Details - Permit 07060979
Plan Review Stops For Permit 07060979
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-09-25 Cont ID  
Sent By rmcdouga Date 2007-09-25 Time 07:46 Rev Time 0.00
Received By rmcdouga Date 2007-09-25 Time 07:46 Sent To  
Notes
2007-09-25 07:46:242004 FBC W/2006 SUPPLEMENT
 LEVEL 2 ALTERATION / ADDITION
  
 DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY
 IMPACT FEES.
  
 3) SUBMIT SIGNED ENERGY CALCULATIONS. (MISSING FROM THE
 PACKAGE)
  
 4) (PRODUCT APPROVALS MISSING FROM THE PACKAGE) SUBMIT
 PRODUCT APPROVALS FOR THE WINDOWS, STORM PANELS AND
 ROOFING MATERIAL(SPECIFY THE ASSEMBLY THAT WILL BE USED
 AND SUBMIT RAS 117 CALCULATIONS FOR ENHANCED FASTENING)
  
  
 5) ADDRESS COMMENTS FROM FIRST REVIEW THAT APPLY TO THE
 PRODUCT APPROVALS.
  
 6)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 - ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-16 Cont ID  
Sent By rmcdouga Date 2007-07-16 Time 13:09 Rev Time 0.00
Received By rmcdouga Date 2007-07-16 Time 13:09 Sent To  
Notes
2007-07-16 14:25:46DENIED BY BUILDING
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 3) THE NAME OF THE STREET IN THE TITLE BLOCK IS
 INCORRECT. IT IS EL VEDADO. PLEASE CORRECT.
  
 4) SPECIFY HOW HOW NEW ADDITION WILL COMPLY WITH FBC
 R320.1 FOR TERMITE TREATMENT.
  
 5) THE ATTIC INSULATION SPECIFIED ON SHEET 1.1 AND THE
 ENERGY CALC. FORM IS R30 AND IT IS SPECIFIED AS R19 ON
 SHEET 2. PLEASE CORRECT.
  
 6)THE STRUCTURAL NOTES ON SHEET 1.1 SPECIFIES THE
 2001 FBC IN TWO LOCATIONS. PLEASE CORRECT.
  
 7) THE 2006 REVISIONS TO THE 2004 FBC R803.2.3.1
 REQUIRES ROOF SHEATHING TO BE FASTENED WITH 8D RING
 SHANK NAILS IN ALL ROOF ZONES. FASTENER SPACING IS
 REQUIRED TO BE 4 INCHES O.C. IN ROOF ZONE 3, WHICH IS
 THE CORNERS OF FLAT ROOFS. SEE FIGURE R301.2(8).
  
 8) THE STUD PLATE DETAIL NOTES ON 1.1 HAS SPH6. IT
 SHOULD BE SPH4.
  
 9) PLEASE CLARIFY THAT THE WALL BETWEEN THE ADDITION
 AND THE EXISTING FAMILY ROOM IS NOT LOAD BEARING OR
 PROVIDE A DETAIL SHOWING HOW THE ROOF WILL BE
 SUPPROTED.
  
 10) THE WIDOWS ARE NOT IMPACT RATED AND PROTECTION IS
 REQUIRED. SUBMIT PRODUCT APPROVALS FOR THE STORM
 PANELS. SPECIFY THE CONNECTION/MOUNT TYPE, THE
 ANCHOR/FASTENER TYPE AND SPACING.
  
 11)ON THE PRODUCT APPROVAL FOR THE GAF MODIFIED
 ROOFING, SPECIFY WHICH ONE OF THE FASTENING OPTIONS AND
 DESIGN PRESSURES WILL BE USED (CIRCLE THE APPROPRIATE
 ONE ON THE NOA). SUBMIT RAS 117 CALCULATIONS FOR THE
 ENHANCED FASTENING OF THE BASE SHEET AS REQUIRED BY THE
 PRODUCT APPROVAL.
  
 12) THE VALUE OF THE WORK HAS BEEN INCREASED TO
 $7054.00, BASED ON THE ICC BUILDING VALUATION DATA
 TABLE. ADDITIONAL FEES ARE DUE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-09-13 Cont ID  
Sent By btrobaug Date 2007-09-13 Time 12:17 Rev Time 0.00
Received By btrobaug Date 2007-09-13 Time 12:16 Sent To B
Notes
2007-09-13 12:17:24 
  
 PROVISO
  
 R313.1.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE
 ALARMS SHALL BE INTERCONNECTED AND HARD WIRED.
  
 WRT

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-03 Cont ID  
Sent By btrobaug Date 2007-07-03 Time 12:41 Rev Time 0.00
Received By btrobaug Date 2007-07-03 Time 12:33 Sent To M
Notes
2007-07-03 12:41:20 
  
 PROVISO
  
 R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED IN
 NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-10 Cont ID  
Sent By adarroug Date 2007-09-10 Time 16:27 Rev Time 0.00
Received By adarroug Date 2007-09-10 Time 16:27 Sent To Z
Notes
2007-09-10 16:27:50TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-16 Cont ID  
Sent By rmcdouga Date 2007-07-16 Time 13:09 Rev Time 0.00
Received By rmcdouga Date 2007-06-29 Time 14:39 Sent To  
Notes
2007-06-29 14:39:21TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-07-05 Cont ID  
Sent By tgordon Date 2007-07-05 Time 08:58 Rev Time 0.15
Received By tgordon Date 2007-07-05 Time 08:58 Sent To B
Notes
2007-07-05 08:59:12NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop Z ZONING
Rev No 2 Status F Date 2007-09-13 Cont ID  
Sent By choops Date 2007-09-13 Time 10:48 Rev Time 0.00
Received By choops Date 2007-09-13 Time 10:48 Sent To E
Notes
2007-09-13 10:50:56***FAILED***
  
  
 1)TWO (2) COPIES OF ALL PLANS SHALL BE SUBMITTED
 (SURVEYS).
  
 2)INDICATE SETBACK DIMENSIONS FROM PROPERTY LINES
 (SIDE AND REAR) TO THE PROPOSED ADDITION ON BOTH COPIES
 OF THE SURVEY. (REPEAT COMMENT)
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-02 Cont ID  
Sent By choops Date 2007-07-02 Time 08:42 Rev Time 0.00
Received By choops Date 2007-07-02 Time 08:42 Sent To E
Notes
2007-07-02 08:44:06***FAILED***
  
  
 1)PLEASE INDICATE SETBACK DIMENSIONS ON THE SURVEYS,
 FROM PROPERTY LINES TO PROPOSED ADDITION.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720