| Plan Review Stops For Permit 07060972 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-11 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-11 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-28 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-28 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2007-08-28 08:16:42 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)SEE PREVIOUS CORRECTION LISTS.TWO SETS REQUIRED | | | FOR PERMIT ISSUANCE.ONLY ONE INSTALLATION SCHEDULE | | | WAS PROVIDED.DUE TO WORK LOAD, I AM UNABLE TO MAKE | | | PHOTOCOPIES FOR CONTRACTORS AS IT CAUSES FURTHER | | | DELAYS. | | | | | | 2.)THE SPANS ON THE INSTALLATION SCHEDULE SHOULD | | | CORRELATE WITH BLADE LENGTH.FOR A WALL MOUNT, THIS | | | WILL BE A DIMENSION LARGER THAN THE OPENING HEIGHT. | | | PLEASE REVISE. | | | | | | 3.)OPENING 8, SPAN OVER 8' REQUIRES 7.5 SPACING, SEE | | | HIGHLIGHTED PRODUCT APPROVAL.CHECK ALL OPENINGS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-03 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-03 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2007-08-03 16:01:53 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.) SEE OPENINGD 1 AND 2.SECTION 6, BOTTOM, CONCRETE | | | BLOCK NOT ALLOWED.NOTE THAT YOU HAVE CIRCLED ANCHOR | | | SPACING FOR SECTION 5. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-30 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-30 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2007-07-30 09:28:56 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)TWO COLLATED IDENTICAL SETS REQUIRED FOR | | | PERMITTING.ONLY ONE INSTALLATION SCHEDULE WAS | | | SUBMITTED. | | | | | | 2.)SEE SHEET 8 OF THE PANEL PRODUCT APPROVAL.EDGE | | | DISTANCE OF 3" REQUIRES A FACTOR OF .86 FOR ANCHOR | | | SPACING. | | | | | | 3.)ANCHOR TYPE "316 AISI" IS NOT CONSISTENT WITH THE | | | ANCHORS ON THE PRODUCT APPROVAL.THIS SHOULD CORRELATE | | | WITH ANCHORS ON THE ANCHOR SPACING CHART (CALK-IN, | | | SOLID SET, PANEL MATE, ETC.).NOTE THAT YOU HAVE | | | SPECIFIED "TAPCON" FOR THE ACCORDIONS, BUT HIGHLIGHTED | | | SPACING FOR SOLID SET. | | | | | | 4.)PLEASE MARK DETAILS IN INK RATHER THAN HIGHLIGHTER | | | ON THE PRODUCT APPROVAL AS THE HIGHLIGHTER DOES NOT | | | APPEAR WHEN SCANNED.THIS IS NOT REQUIRED FOR | | | PERMITTING (AS ALL INFORMATION WILL BE INCLUDED ON THE | | | INSTALLATION SCHEDULE) BUT DOES HELP TO EXPEDITE PLAN | | | REVIEW. | | | | | | 5.)WHEN YOU SPECIFY A CBS SUBSTRATE, YOU MUST USE THE | | | "TO MASONRY" OR "CONCRETE BLOCK" COLUMN, NOT "TO | | | CONCRETE" OR "POURED CONCRETE". | | | | | | 6.)A DESIGN PRESSURE OF -44.8 REQUIRES USE OF THE -60 | | | COLUMN, NOT -40. | | | | | | 7.)THE SHUTTER MOUNTING CONNECTION TYPE SHOULD STATE | | | WHICH CONECTION TYPE YOU ARE USING, NOT THE ANCHOR. FOR | | | THE PANELS, THIS WILL BE 1-9; FOR THE ACCORDIONS IT | | | WILL BE A THROUGH L. | | | | | | 8.)SHUTTER MOUNTING CONNECTION TYPES A AND D WERE | | | HIGHLIGHTED.NOTE THAT THESE CONNECTION TYPES REQUIRE | | | A POURED CONCRETE SUBSTRATE, NOT BLOCK. | | | | | | 9.)1" IS NOT ADEQUATE FOR THE MINIMUM GLASS | | | SEPARATION FOR ACCORDIONS, SEE SHEET 12. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-13 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-13 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2007-07-13 16:50:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | | | ____1.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A | | | DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER | | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | | ORIGINALS FAC61G15-23.002. | | | | | | ____2.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_3.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT. | | | | | | ____4.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | ____5.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS | | | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A | | | HIGHLIGHTER. | | | | | | ____6.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | | R310. | | | | | | _XX_7.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 3 | | | ABOVE. | | | | | | ____8.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), | | | FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE | | | C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC | | | R301.2.1.4. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-05 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-05 |
Time |
13:08 |
Sent To |
B |
|
| Notes |
| 2007-09-05 13:09:07 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-13 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-13 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
| 2007-08-13 11:49:30 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-02 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-02 |
Time |
14:26 |
Sent To |
B |
|
| Notes |
| 2007-08-02 14:26:31 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-19 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-19 |
Time |
15:53 |
Sent To |
B |
|
| Notes |
| 2007-07-19 15:54:00 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-13 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-28 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2007-06-28 16:53:25 | TO "MISC" BOX#1 |
|
|