| Plan Review Stops For Permit 07060891 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-09-20 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-09-20 |
Time |
16:10 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-08-28 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-08-28 |
Time |
15:45 |
Sent To |
I |
|
| Notes |
| 2007-08-28 17:20:04 | PROJECT: 400 NORTH FLAGLER #704 | | | | | | PROJECT SCOPE: INTERIOR ALTERATION/MASTER BATH ONLY | | | | | | REVIEW: 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS | | | 2004 FLORIDA EXISTING BUILDING CODE | | | | | | STATUS: FAILED | | | | | | COMMENTS: | | | | | | | | | 1) 1) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE | | | FOLLOWING: | | | | | | FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 2) PLANS SHALL CONFORM TO THE MINIMUM PLAN REVIEW | | | CRITERIA: | | | | | | 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING | | | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA | | | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION | | | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; AND ALL | | | EXTERIOR ELEVATIONS: | | | COMMERCIAL BUILDINGS: | | | BUILDING | | | | | | 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY | | | REQUIREMENTS SHALL BE DETERMINED. | | | 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE | | | DETERMINED (SEE TABLE 503). | | | 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS | | | SHALL INCLUDE THE FOLLOWING COMPONENTS: | | | FIRE-RESISTANT SEPARATIONS | | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | | | | | FIRE BLOCKING AND DRAFTSTOPPING AND | | | CALCULATED FIRE RESISTANCE | | | | | | PLEASE PROVIDE SIGNED/SEALED FLOOR PLAN AND APPLICABLE | | | FRAMING DETAILS. INDICATE LOCATION OF EXISTING FIRE | | | RATED WALL PARTITIONS AND RATING OF THE SAME. | | | | | | 3) A DESIGN PROFESSIONAL SHALL INDICATE THE LEVEL OF | | | ALTERATION: | | | | | | 301.5 . A DESIGN PROFESSIONAL OR AN | | | OWNER MUST ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO SECTION | | | 303,304 & 305 OF THIS CODE. | | | | | | 4)) PRIOR TO RE-SUBMITTING THE REVIEWED PLANS, PLEASE | | | MAKE CERTAIN TO REVIEW AND ADDRESS EACH COMMENT AS | | | NOTED BELOW AND MAKE ALL CORRECTIONS WHERE APPLICABLE. | | | FAILURE TO DO SO WILL IMPEDE THE EXPEDITING OF THE | | | PERMIT ISSUANCE. | | | | | | PLAN REVIEW: KEN CONRAD | | | PHONE: 561.805.6666 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-07-12 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-07-12 |
Time |
07:29 |
Sent To |
I |
|
| Notes |
| 2007-07-12 07:30:54 | PREINSPECT DENIED. REQUIRE PLANS SHOWING ALL SCOPE OF | | | WORK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-26 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-26 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-03 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-03 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2007-08-03 16:35:54 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1. | | | | | | BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE PER | | | 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI | | | PROTECTED PER 210.8(A) (1). 2005 NEC LOCATE SAME ON | | | PLANS. | | | | | | THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER | | | 106.3.4.3.FBC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-10-02 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-02 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-02 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2007-10-02 10:49:35 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEET STAMPED, INITIALED, AND | | | DATED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-08-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-12 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-12 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2007-08-12 13:50:57 | *****DENIED***** | | | | | | | | | 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.THE REMOVAL OF OLD AND/OR THE STOCKING OF NEW | | | BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE OR | | | HINDER ACCESS TO/EGRESS FROM THE 7TH FLOOR.EXITS AND | | | EXIT AISLE CORRIDORS ARE TO BE MAINTAINED AND CLEAR OF | | | OBSTRUCTIONS. | | | | | | 4.BATHROOM DOORS SHALL NOT BE LESS THAN 24" WIDE,NO | | | LESS THAN 78" IN NOMINAL HEIGHT, AND SHALL BE DESIGNED | | | TO ALLOW OPENING FROM THE OUTSIDE DURING AN EMERGENCY | | | WHEN LOCKED. | | | | | | 5.SPECIFY THE NEW INTERIOR WALL AND CEILING FINISH | | | MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-14 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-14 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2007-09-20 09:05:18 | TO "BOB"#16 | | 2007-09-14 14:00:50 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-08-28 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-07-20 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2007-08-01 11:08:45 | TO "BOB"#8 | | 2007-07-20 08:52:10 | WAITING FOR "BOB" |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-02 |
Time |
07:21 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-02 |
Time |
07:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-08 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-08 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2007-08-08 14:58:01 | DENIED; | | | 1.SHOWDEMO PLAN. | | | 2. ADD NOTE TO PLANS, "PLUMBING DEMO WORK TO BE DONE BY | | | LICENSED PLUMBING CONTRACTOR. NO DEAD ENDS PERMITED IN | | | THE DRAINAGE SYSTEM. PLUMBING INSPECTION REQUIRED". | | | 3. PLANS TO BE SIGNED BY THE PERSON TAKING | | | RESPONSIBILITY. | | | 4.IF THE TILE IS TO BE REMOVED FROM SHOWER THE SHOWER | | | PANMUST BE REPLACED PLEASE ADD TO NOTE. | | | PLUMBING PLAN REVIEW; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-02 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-02 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2007-08-02 08:20:16 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|