Plan Review Details - Permit 07060891
Plan Review Stops For Permit 07060891
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-09-20 Cont ID  
Sent By kconrad Date 2007-09-20 Time 18:15 Rev Time 0.00
Received By kconrad Date 2007-09-20 Time 16:10 Sent To I
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-28 Cont ID  
Sent By kconrad Date 2007-08-28 Time 16:45 Rev Time 0.00
Received By kconrad Date 2007-08-28 Time 15:45 Sent To I
Notes
2007-08-28 17:20:04PROJECT: 400 NORTH FLAGLER #704
  
 PROJECT SCOPE: INTERIOR ALTERATION/MASTER BATH ONLY
  
 REVIEW: 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS
 2004 FLORIDA EXISTING BUILDING CODE
  
 STATUS: FAILED
  
 COMMENTS:
  
  
 1) 1) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE
 FOLLOWING:
  
 FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 2) PLANS SHALL CONFORM TO THE MINIMUM PLAN REVIEW
 CRITERIA:
  
 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING
 OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION
 PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; AND ALL
 EXTERIOR ELEVATIONS:
 COMMERCIAL BUILDINGS:
 BUILDING
  
 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY
 REQUIREMENTS SHALL BE DETERMINED.
 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE
 DETERMINED (SEE TABLE 503).
 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS
 SHALL INCLUDE THE FOLLOWING COMPONENTS:
  FIRE-RESISTANT SEPARATIONS
 FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION
 PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS
  
 FIRE BLOCKING AND DRAFTSTOPPING AND
 CALCULATED FIRE RESISTANCE
  
 PLEASE PROVIDE SIGNED/SEALED FLOOR PLAN AND APPLICABLE
 FRAMING DETAILS. INDICATE LOCATION OF EXISTING FIRE
 RATED WALL PARTITIONS AND RATING OF THE SAME.
  
 3) A DESIGN PROFESSIONAL SHALL INDICATE THE LEVEL OF
 ALTERATION:
  
 301.5 . A DESIGN PROFESSIONAL OR AN
 OWNER MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO SECTION
 303,304 & 305 OF THIS CODE.
  
 4)) PRIOR TO RE-SUBMITTING THE REVIEWED PLANS, PLEASE
 MAKE CERTAIN TO REVIEW AND ADDRESS EACH COMMENT AS
 NOTED BELOW AND MAKE ALL CORRECTIONS WHERE APPLICABLE.
 FAILURE TO DO SO WILL IMPEDE THE EXPEDITING OF THE
 PERMIT ISSUANCE.
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-12 Cont ID  
Sent By kconrad Date 2007-07-12 Time 07:29 Rev Time 0.00
Received By kconrad Date 2007-07-12 Time 07:29 Sent To I
Notes
2007-07-12 07:30:54PREINSPECT DENIED. REQUIRE PLANS SHOWING ALL SCOPE OF
 WORK.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-09-26 Cont ID  
Sent By btrobaug Date 2007-09-26 Time 16:29 Rev Time 0.00
Received By btrobaug Date 2007-09-26 Time 16:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-08-03 Cont ID  
Sent By btrobaug Date 2007-08-03 Time 16:35 Rev Time 0.00
Received By btrobaug Date 2007-08-03 Time 16:25 Sent To  
Notes
2007-08-03 16:35:54 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002,
 NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.
  
 BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE PER
 210.11(C) (3), LOCATED PER 210.52(D), AND BE GFI
 PROTECTED PER 210.8(A) (1). 2005 NEC LOCATE SAME ON
 PLANS.
  
 THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME, ALL SHEETS, PER
 106.3.4.3.FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-10-02 Cont ID  
Sent By mawillia Date 2007-10-02 Time 10:49 Rev Time 0.00
Received By mawillia Date 2007-10-02 Time 10:39 Sent To  
Notes
2007-10-02 10:49:35*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED;PLAN SHEET STAMPED, INITIALED, AND
 DATED.
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-08-12 Cont ID  
Sent By mawillia Date 2007-08-12 Time 13:51 Rev Time 0.00
Received By mawillia Date 2007-08-12 Time 13:20 Sent To  
Notes
2007-08-12 13:50:57*****DENIED*****
  
  
 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 3.THE REMOVAL OF OLD AND/OR THE STOCKING OF NEW
 BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE OR
 HINDER ACCESS TO/EGRESS FROM THE 7TH FLOOR.EXITS AND
 EXIT AISLE CORRIDORS ARE TO BE MAINTAINED AND CLEAR OF
 OBSTRUCTIONS.
  
 4.BATHROOM DOORS SHALL NOT BE LESS THAN 24" WIDE,NO
 LESS THAN 78" IN NOMINAL HEIGHT, AND SHALL BE DESIGNED
 TO ALLOW OPENING FROM THE OUTSIDE DURING AN EMERGENCY
 WHEN LOCKED.
  
 5.SPECIFY THE NEW INTERIOR WALL AND CEILING FINISH
 MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-14 Cont ID  
Sent By adarroug Date 2007-09-14 Time 14:00 Rev Time 0.00
Received By adarroug Date 2007-09-14 Time 14:00 Sent To  
Notes
2007-09-20 09:05:18TO "BOB"#16
2007-09-14 14:00:50WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-28 Cont ID  
Sent By kconrad Date 2007-08-28 Time 16:50 Rev Time 0.00
Received By kconrad Date 2007-07-20 Time 08:51 Sent To  
Notes
2007-08-01 11:08:45TO "BOB"#8
2007-07-20 08:52:10WAITING FOR "BOB"

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-10-02 Cont ID  
Sent By jleech Date 2007-10-02 Time 07:21 Rev Time 0.00
Received By jleech Date 2007-10-02 Time 07:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-08-08 Cont ID  
Sent By jleech Date 2007-08-08 Time 14:48 Rev Time 0.00
Received By jleech Date 2007-08-08 Time 14:48 Sent To  
Notes
2007-08-08 14:58:01DENIED;
 1.SHOWDEMO PLAN.
 2. ADD NOTE TO PLANS, "PLUMBING DEMO WORK TO BE DONE BY
 LICENSED PLUMBING CONTRACTOR. NO DEAD ENDS PERMITED IN
 THE DRAINAGE SYSTEM. PLUMBING INSPECTION REQUIRED".
 3. PLANS TO BE SIGNED BY THE PERSON TAKING
 RESPONSIBILITY.
 4.IF THE TILE IS TO BE REMOVED FROM SHOWER THE SHOWER
 PANMUST BE REPLACED PLEASE ADD TO NOTE.
 PLUMBING PLAN REVIEW;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-02 Cont ID  
Sent By choops Date 2007-08-02 Time 08:20 Rev Time 0.00
Received By choops Date 2007-08-02 Time 08:20 Sent To  
Notes
2007-08-02 08:20:16*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.