Plan Review Details - Permit 07060884
Plan Review Stops For Permit 07060884
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-14 Cont ID  
Sent By btrobaug Date 2007-07-06 Time 16:36 Rev Time 0.00
Received By amorse Date 2007-07-14 Time 11:33 Sent To P
Notes
2007-07-14 11:51:06 
  
 DENIED
  
 1)CONTRACTORS SIGNATURE WAS NOT WITNESSED AND
 NOTARIZED ON PERMIT APPLICATION
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $ 378.26 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 4)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
  
 5)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE
 BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS
 DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN
 GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600
 FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C
 CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND
 PRESSURES ACCORDINGLY
  
 6)PROVIDE THE DESIGN PRESSURE VALUES FOR THE NEW
 WINDOW OPENINGS
  
  
  
 7)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 8)SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT
 APPLICATION OR BEFORE INSTALLATION THAT
 HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD
  
 9)SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL. NOTE THE ENERGY CALC'S ARE NOT SIGNED BY
 OWNER/AGENT AND INFORMATION ON WALL R VALUE IS MISSING
  
 10)DRAWINGS ARE TO CONTAIN THE INSULATION VALUES TO
 MATCH THE ENERGY CALC'S. PLEASE NOTE THAT ENERGY CALC
 HAS R VALUE FOR RAISED FLOOR BUT DRAWING DOES NOT SHOW
 ANY INSULATION AT ALL
  
 11)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER
 R313.1.1 FBC RES.
  
 12)ADDITIONAL PERMITS WILL BE REQUIRED FOR
 ELECTRICAL, FIRE SPRINKLERS AND ROOFING
  
 13)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006
 AMENDMENTS
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 W/2006 AMENDMENTS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-07-06 Cont ID  
Sent By btrobaug Date 2007-07-06 Time 15:55 Rev Time 0.00
Received By btrobaug Date 2007-07-06 Time 15:30 Sent To M
Notes
2007-07-06 15:55:19 
 PROVISO
  
 R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED IN
 NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
 FAX/:561/805-6676

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-18 Cont ID  
Sent By jleech Date 2007-07-18 Time 07:45 Rev Time 0.00
Received By jleech Date 2007-06-27 Time 14:30 Sent To  
Notes
2007-06-27 14:30:16TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-07-09 Cont ID  
Sent By tgordon Date 2007-07-09 Time 09:14 Rev Time 0.30
Received By tgordon Date 2007-07-09 Time 09:14 Sent To B
Notes
2007-07-09 09:15:08NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-07-18 Cont ID  
Sent By jleech Date 2007-07-18 Time 07:43 Rev Time 0.00
Received By jleech Date 2007-07-18 Time 07:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-06-28 Cont ID  
Sent By choops Date 2007-06-28 Time 16:43 Rev Time 0.00
Received By choops Date 2007-06-28 Time 16:43 Sent To E
Notes
2007-06-28 16:44:55***FAILED***
  
  
 1)PLEASE PROVIDE 2 COPIES OF A CURRENT SURVEY
 SHOWING THE SCOPE OF WORK WITH DIMENSIONS AND SETBACK
 DIMENSIONS TO THE PROPERTY LINES.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720