| Plan Review Stops For Permit 07060881 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2009-11-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-11-05 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-11-05 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2009-11-05 11:28:33 | KITCHEN WINDOW NOA AND SHUTTER NOA/INSTALLATION | | | SCHEDULE | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-10-28 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-10-28 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2009-10-28 09:29:53 | REVISION A4, A5 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-10-28 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-10-28 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2009-10-28 09:29:24 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. IMPACT PROTECTION REQUIRED, FBC R301. SUBMIT SHUTTER | | | PRODUCT APPROVAL AND INSTALLATION SCHEDULE HTTP://WWW.C | | | ITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_INSTALLATION | | | .PDF | | | | | | 2. THIS PERMIT WAS ISSUED WITH PROVISO, | | | LANDSCAPE/IRRIGATION PLAN REQUIRED PRIOR TO C.O. PLEASE | | | ADVISE AS TO STATUS OF THAT REVISION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2009-06-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-06-25 |
Time |
18:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-24 |
Time |
17:56 |
Sent To |
Z |
|
| Notes |
| 2009-06-25 18:24:50 | REVISION DATED 4/25/9 | | | COMMENT LIST REVISED 7/8/9 | | | | | | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | | | 1. M2.01, DETAIL FOR SECURING CONDENSING IS NOT CLEAR. | | | TWO BRACKETS ARE GRAPHICALLY SHOWN ON ONE SIDE OF THE | | | UNIT, BUT THE TEXT SPECIFIES 4. IF FOUR ARE INSTALLED, | | | TWO PER SIDE, THIS LEAVES TWO SIDES WITHOUT BRACKETS, | | | NOT CLEAR HOW THOSE TWO SIDES WILL RESIST WIND | | | PRESSURES. | | | | | | PLEASE DO NOT RESUBMIT THE MECHANICAL SHEETS. EITHER | | | PROVIDE A NEW DETAIL OR THIS WILL BE PROVISO ITEM, | | | INSTALL IN ACCORDANCE WITH FBC R301, SUBJECT TO | | | INSPECTOR'S DISCRETION. | | | | | | 2. R703.6.3, DETAIL 4 A5 DOES NOT SHOW REQUIRED BOND | | | BREAK. ***IF PLANS DO NOT NEED TO BE REVISED FOR OTHER | | | REASONS, THIS WILL BE A REDLINE ITEM*** | | | | | | 3. A NEW WINDOW OPENING IS SHOWN, PLEASE PROVIDE | | | FRAMING DETAIL FBC R301. ***IF PLANS DO NOT REQUIRE | | | REVISION FOR OTHER REASONS, THIS WILL BE A PROVISO | | | ITEM.** | | | | | | 4. A4 STATES TO REPLACE EXIST NON ORIGINAL ALUMINUM | | | CASEMENT WINDOW WITH AN ALUMINUM AWNING WINDOW, REUSED. | | | FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | | THE INSTALLED WINDOW, FAC9B72. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-04-17 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-04-17 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2009-04-17 14:06:14 | REVISION DATED 3/9/9 OK (FOOTING) | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-12-11 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-12-11 |
Time |
17:45 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-02 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-10-02 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-10-02 |
Time |
18:38 |
Sent To |
PC |
|
| Notes |
| 2007-10-02 18:57:59 | | | | | | | DENIED | | | | | | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST | | | REVIEW ON 7/14/07: | | | | | | 5)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | | AND OWNER/AGENT PRIOR TO SUBMITTAL | | | ****NOTE MAKE THE FOLLWING CORRECTIONS TO ENERGY | | | CALC'S, WALLS ARE WOOD FRAME NOT CONCRETE, THEY ARE NOT | | | SIGNED BY OWNER AGENT, AND UNLESS COMPLETE HOUSE IS | | | BEING BROUGHT UP TO NEW ENERGY STANDARDS FORM 600C-04R | | | SHOULD BE USED FOR ADDITIONS OR RENOVATIONS 600 SQ. FT. | | | OR LESS**** | | | | | | 7)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | | AMENDMENTS PER 106.1.1 FBC* | | | ****NOTE THIS SHALL BE INCUDED ON THE PERMIT SET OF | | | DRAWINGS**** | | | | | | 8)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | | DRAWINGS | | | ****NOTE ALTERATION LEVEL FITS THE DEFINITION OF A | | | LEVEL 2, PLEASE SEE ATTACHED COPY OF CHAPTER 3 | | | CLASSIFICATION OF WORK**** | | | | | | NEW COMMENTS | | | | | | 1)PROVIDE PRODUCT APPROVALS FOR THE NEW FRONT ENTRY | | | DOOR | | | | | | 2)NEW NOTE UNDER WINDOW SCHEDULE ON A-3 IS INCORRECT | | | PLEASE REMOVE, ALL OPENINGS WITHIN 30 FEET OF GRADE | | | SHALL MEET LARGE MISSILE IMPACT REQUIREMENTS PER | | | 1609.1.4 (1) FBC | | | | | | 3)PROVIDE PRODUCT APPROVALS FOR SHUTTERS FOR WINDOWS | | | IN NEW LOCATIONS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-14 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-07-14 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-07-14 |
Time |
07:38 |
Sent To |
PC |
|
| Notes |
| 2007-07-14 08:49:33 | | | | | | | DENIED | | | | | | 1)A TITLE BLOCK WITH THE INFORMATION SPECIFIED PER | | | 61G1-16.004 FAC SHALL BE PRESENT ON DRAWINGS ISSUED BY | | | THE RESPONSIBLE ARCHITECT AND MUST, | | | AT A MINIMUM CONTAIN | | | ****1)FIRM/LICENSEE NAME,ADDRESS, AND TELEPHONE # | | | ****2)FIRM/LICENSEE LICENSE # | | | 3)NAME OF PROJECT | | | 4)DATE PREPARED | | | 5)A SPACE FOR SIGNATURE & DATED SEAL | | | 6)A SPACE FOR PRINTED NAME OF PERSON | | | SEALING THE DOCUMENT. | | | | | | 2)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF | | | EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA | | | STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT | | | LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES. ALL | | | CAN BE FOUND ON WWW.FLORIDABUILDING.ORG | | | | | | *****PROVIDE PRODUCT APPROVALS FOR ALL NEW DOORS AND | | | WINDOWS AS WELL AS ROOFING PRODUCTS***** | | | | | | 3)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | | | | | 4)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | | STATE PRODUCT APPROVAL COVER | | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | | SUBMITTED APPLICATIONS WILL BE DENIED | | | | | | 5)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER | | | AND OWNER/AGENT PRIOR | | | TO SUBMITTAL | | | | | | *****NOTE PLEASE CORRECT INFORMATION ON THE ENERGY | | | CALC'S FLOOR TYPE IS NOT SLAB ON GRADE AS EXISTING | | | BUILDING HAS CRAWL SPACE, WALLS ARE NOT CONCRETE, MORE | | | THAN ONE TYPE OF CEILING IS PRESENT ON DRAWINGS.***** | | | | | | 6)PROVIDE DETAILS OF ALL STRUCTURAL WORK, NEW COLUMNS | | | AND BEAM, FRAMED WALL INFILL, ETC. | | | | | | 7)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | | AMENDMENTS | | | | | | 8)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | | DRAWINGS | | | | | | 9)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND | | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | | TO SUBMITTAL | | | | | | 10)PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4 | | | FBC | | | | | | 11)PROVIDE DESIGN PRESSURES FOR ALL NEW DOOR AND | | | WINDOW OPENINGS | | | | | | 12)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | 13)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS | | | OF NEW DRAWINGS AND INCLUDE 1 COPY OF THE OLD PAGES | | | ONLY FOR REFERENCE | | | | | | 14)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER | | | R313.1.1 FBC RES. | | | | | | 15)ADDITIONAL PERMITS WILL BE REQUIRED FOR PLUMBING, | | | ELECTRICAL AND MECHANICAL AND ROOFING | | | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | | AMENDMENTS | | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | | AMENDMENTS TO FBC | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | FBC RES. = FLORIDA BUILDING CODE | | | RESIDENTIAL 2004 W/2006 AMENDMENTS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-12-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-12-04 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-12-04 |
Time |
09:56 |
Sent To |
PC |
|
| Notes |
| 2008-12-04 10:03:12 | | | | | | | | | | REVISION DENIED | | | | | | THE DESIGNER OF RECORD IS THE ONLY PERSON AUTHORIZED TO | | | REVISE HIS/HER PLAN. TAKE ALL PROPOSED CHANGES TO THE | | | DESIGNER TO BE REDRAWN.FS 471.025 | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-26 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-25 |
Time |
06:35 |
Sent To |
P |
|
| Notes |
| 2007-09-26 13:18:17 | | | | | | | | | | PROVISO | | | | | | THE SMOKE DETECTOR THAT WAS ADDED TO THE DEN BATHROOM | | | IS IN VIOLATION OF NFPA-72, 11.8.3.5 (5) SMOKE ALARMS | | | AND SMOKE DETECTORS SHALL NOT BE INSTALLED WITHIN A | | | 914-MM (36-IN.) HORIZONTAL PATH FROM A DOOR TO A | | | KITCHEN OR A BATHROOM CONTAINING A SHOWER OR TUB. MUST | | | NOT BE INSTALLED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-29 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-29 |
Time |
06:58 |
Sent To |
M |
|
| Notes |
| 2007-06-29 08:59:10 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} PROVIDE LOAD CALCULATIONS, INCLUDE ADDED LOADS, PER | | | ARTICLE 220 PART III, STANDARD OR PART IV OPTIONAL, | | | INDICATE METHOD USED, INDICATE THE SIZE OF THE EXISTING | | | SERVICE. INDICATE THE SIZE AND TYPE OF THE SERVICE | | | ENTRANCE CONDUCTORS ON THE RISER DIAGRAM, SHEET E2.01. | | | PER 215.5. | | | | | | 2} SUBMIT A PANEL SCHEDULE PER 408.4 NEC AND | | | 106.3.5.4(8) FBC.THE ONE SUBMITTED DOESNT CORRELATE THE | | | LOADS WITH THE EQUIPMENT. SHEET E2.01. | | | | | | 3} R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED | | | IN NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT.LOCATE SAME | | | ON THE PLAN. | | | | | | 4} THE SCUTTLE FOR AHU 1 MUST COMPLY WITH 210.63 | | | (RECEPTACLE). | | | | | | 5} THE LOCATION OF THE NEW A/C SERVICE PANEL MUST | | | COMPLY WITH 110.26 CLEARANCE REQUIREMENTS. IT WOULD | | | APPEAR IT IS LOCATED OVER THE CONDENSER PAD , WHICH | | | WOULD BE A VIOLATION. PLEASE VERIFY AND RELOCATE NOW IF | | | NECESSARY TO PREVENT AN INSPECTION ISSUE AFTER THE | | | EQUIPMENT IS INSTALLED. | | | | | | NOTE: PLEASE VERIFY THAT THE NEW PANEL WILL BE FED FROM | | | THE METER AND NOT SUBFED FROM THE EXISTING PANEL. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW. | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2009-10-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-27 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-27 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2009-10-27 15:05:14 | PASSED -- REVISION REQUIRED THE GAS RISER PIPING SHALL | | | REFLECT THE INSTALLATION. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-06-22 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-06-22 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2009-06-22 15:07:45 | SEE APPROVAL ON PLANS BY JULIAN 6/22/09 LM | | 2007-06-27 09:14:35 | OK PER G JUDGE 6-27-07 NO FEE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-11-02 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-29 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-10-29 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2009-11-02 13:49:03 | GAVE TO SAMANTHA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2009-10-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-22 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-22 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2009-10-22 11:08:38 | SENT TO KSTEVENS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-06-22 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-03 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2009-07-02 11:45:08 | PLANS GIVEN TO AMY STELLY TO REVIEW IN MAGGIE'S | | | ABSENCE. CONTRACTOR BRING SURVEY DRAWING (REQUESTED BY | | | MAGGIE) TO AMY STELLY. 7/2/09. RB | | | | | | | | 2009-06-24 14:23:48 | TAKEN OF RESIDENTIAL BOARD, TO SMH DESK | | | | | 2009-06-04 15:39:46 | TO R2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-04-17 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2009-04-17 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2009-04-17 |
Time |
11:49 |
Sent To |
B |
|
| Notes |
| 2009-04-17 11:50:07 | TO "SHILL" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-12-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-02 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-02 |
Time |
16:31 |
Sent To |
E |
|
| Notes |
| 2008-12-02 16:31:45 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-26 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-26 |
Time |
16:38 |
Sent To |
Z |
|
| Notes |
| 2007-11-26 16:38:48 | TO "Z" BOX/RESUB--NEW SHEET FOR "Z" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
09:08 |
Sent To |
Z |
|
| Notes |
| 2007-09-17 09:08:56 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-07-14 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-27 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2007-06-27 13:54:35 | TO "SFR" "Z" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-06-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-15 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-15 |
Time |
16:01 |
Sent To |
P |
|
| Notes |
| 2009-06-15 16:02:30 | **PROVISO** | | | | | | AHU SERVICE PANEL SHALL BE WITHIN 6' OF ATTIC ACCESS | | | PER FBC-R SECTION N1110.AB.3.5.2. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-25 |
Time |
06:45 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-06-29 |
Time |
15:24 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-06-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-29 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-29 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2009-06-29 11:18:01 | REVISION OK -- SANITARY ISOMETRIC RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2009-06-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-15 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-15 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2009-06-15 16:50:44 | REVISION DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL | | | DRAWING AND SPECIFICATION SHEETS. A TITLE BLOCK MUST, | | | AT A MINIMUM, CONTAIN THE FOLLWOING INFORMATION: | | | (1) FIRM NAME, ADDRESS AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER | | | (3) NAME OR IDENTIFICATION OF PROJECT | | | (4) DATE PREPARED | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL - (OK) | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | FAC 61G1-16.004 & FS 481.2055. -- THIS INFORMATION IS | | | MISSING FROM THE 8-1/2 X 11 INCH SHEET WITH THE | | | SANITARY RISER DIAGRAM. | | | | | | 2. THE SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | | FLOOR PLAN, NOR DOES IT MEET THE CODE REQUIRMENTS. | | | (A) THE DOUBLE LAV IS ON THE WALL OPPOSITE OF THE W/C | | | AND SHOWER. THE RISER SHOWS IT AT THE WALL TO THE LEFT | | | SIDE OF THE FIXTURES. | | | (B) FIXTURES SHALL NOT BE DOUBLE TRAPPED. THE WATER | | | CLOSET HAS AN INTEGRAL TRAP IN THE FIXTURE SO NO TRAP | | | IS REQUIRED ON THE FIXTURE ROUGH. | | | SECTIONS 106.1.1 & 1002.1/P3201.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-10-01 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-10-01 |
Time |
09:11 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-07-11 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-11 |
Time |
07:51 |
Sent To |
B |
|
| Notes |
| 2007-07-11 09:29:23 | SANITARY RISER DIAGRAM REQUIRED FOR 2ND FLOOR BATHROOM | | | AND ADDED SINK. SEE FBC BUILDING CHAPTER 1 | | | ADMINISTRATION CODE SECTION 106.3.5.4(9). | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-07-05 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-07-05 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-07-05 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2009-07-05 11:48:32 | PASSED WITH PROVISO: | | | THE LANDSCAPE/IRRIGATION PLANS SHALL BE APPROVED PRIOR | | | TO FINAL C.O. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-28 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-28 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
| 2007-11-28 15:27:08 | ***APPROVED - RESUB #2 - RESTAMPED PLANS*** | | | | | | PROVISO: | | | | | | 1)AS THE STRUCTURE IS NONCONFORMING WITH RESPECT TO | | | THE REQUIRED SETBACK DIMENSIONS, AS PER SECTION | | | 94-513(A)(2) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS:NONCONFORMING STRUCTURES OR BUILDINGS | | | SHALL NOT BE IMPROVED, CONSTRUCTED, ENLARGED, OR | | | ALTERED IN ANY MANNER TO CREATE A NEW NONCONFORMITY OR | | | TO INCREASE AN EXISTING NONCONFORMITY, BUT MAY BE | | | IMPROVED, CONSTRUCTED, ENLARGED, OR ALTERED AS LONG AS | | | NO NEW NONCONFORMITY IS CREATED OR AN EXISTING | | | NONCONFORMITY INCREASED. | | | 2)AS THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE | | | VALUE OF THE HOME, LANDSCAPING SHALL BE BROUGHT TO | | | CURRENT REGULATIONS, IF NOT ALREADY:FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-18 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-18 |
Time |
15:05 |
Sent To |
E |
|
| Notes |
| 2007-09-18 15:13:46 | ***APPROVED - RESUB #1*** | | | | | | PROVISO: | | | | | | 1)AS THE STRUCTURE IS NONCONFORMING WITH RESPECT TO | | | THE REQUIRED SETBACK DIMENSIONS, AS PER SECTION | | | 94-513(A)(2) OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS:NONCONFORMING STRUCTURES OR BUILDINGS | | | SHALL NOT BE IMPROVED, CONSTRUCTED, ENLARGED, OR | | | ALTERED IN ANY MANNER TO CREATE A NEW NONCONFORMITY OR | | | TO INCREASE AN EXISTING NONCONFORMITY, BUT MAY BE | | | IMPROVED, CONSTRUCTED, ENLARGED, OR ALTERED AS LONG AS | | | NO NEW NONCONFORMITY IS CREATED OR AN EXISTING | | | NONCONFORMITY INCREASED. | | | 2)AS THE VALUE OF PROPOSED WORK EXCEEDS 50% OF THE | | | VALUE OF THE HOME, LANDSCAPING SHALL BE BROUGHT TO | | | CURRENT REGULATIONS, IF NOT ALREADY:FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-06-27 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-06-27 |
Time |
14:17 |
Sent To |
E |
|
| Notes |
| 2007-06-27 14:20:44 | ***FAILED*** | | | | | | | | | 1)PROVIDE 2 COPIES OF A CURRENT SURVEY SHOWING THE | | | SCOPE OF WORK WITH DIMENSIONS AND SETBACK DIMENSTIONS | | | TO THE PROPERTY LINES.(NOTE:SHOW ANY EXTERIOR WORK | | | BEING DONE: SHOW ANY PROPOSED A/C EQUIPMENT WITH | | | SETBACKS, SHOW ANY OVERHANGS/PORCHES...ETC. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN |
|
|