| Plan Review Stops For Permit 07060770 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-12 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-12 |
Time |
17:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-10 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-10 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2007-09-10 15:28:16 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)PREVIOUS LIST NOTED THE FACTOR REQUIREMENT FOR | | | EDGE DISTANCE LESS THAN 3 1/2".SEE OPENING 2.A 2" | | | EDGE DISTANCE REQUIRES A .5 FACTOR; ANCHOR SPACING TOP | | | AND BOTTOM SHOULD BE 4.5.CHECK ALL OPENINGS. | | | | | | 2.)ALSO SEE PREVIOUS LIST IN REGARDS TO OPENING 8. | | | 2" EDGE DISTANCE CANNOT BE USED AS 5.5 SPACING WITH A | | | FACTOR OF .5 EQUALS 2.75", MINIMUM IS 3" SPACING. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-29 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-29 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2007-08-29 15:40:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | 1.)SEE OPENING 8.WALL MOUNT INTO CBS, .5 FACTOR FOR | | | 2" EDGE DISTANCE REQUIRES 2.75 SPACING WHICH IS NOT | | | ALLOWED (3" MINIMUM).YOU HAVE SPECIFIED SPACING OF | | | 6.2PLEASE REVISE.CHECK ALL OPENINGS. | | | | | | THE SAME INSTALLATION SCHEDULE WAS SUBMITTED (I HAD | | | CIRCLED THE ANCHORING FOR OPENING 8, 6.2).PLEASE | | | REVISE AND MARK VOID ON OLD SHEETS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-03 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-03 |
Time |
17:22 |
Sent To |
|
|
| Notes |
| 2007-08-03 17:24:09 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)SEE OPENING 8.WALL MOUNT INTO CBS, .5 FACTOR FOR | | | 2" EDGE DISTANCE REQUIRES 2.75 SPACING WHICH IS NOT | | | ALLOWED (3" MINIMUM).YOU HAVE SPECIFIED SPACING OF | | | 6.2PLEASE REVISE.CHECK ALL OPENINGS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-06 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-06 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2007-07-06 16:34:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)PLEASE EXPLAIN WHY THE SPAN FOR OPENING 1 IS 145" | | | FOR A 103" OPENING.REVISE ALL SPANS AS NECESSARY. | | | | | | 2.)SEE SHEET 14A.A .86 FACTOR REQUIRED FOR 3" EDGE | | | DISTANCE. | | | | | | 3.)4 1/2" REQUIRED FOR THE FLOOR MOUNT WITHOUT THE | | | .86 FACTOR.CHECK ALL OPENINGS. | | | | | | 4.)OPENING 1 STATES FLOOR/CEILING, ANCHORING IS | | | TOP/BOTTOM, SHOULD THIS BE CEILING/FLOOR? | | | | | | 5.)OPENING 3, BOTTOM IS WALL, 6.2".SEE SHEET 14A, | | | CBS REQUIRES 5 1/2" WITHOUT THE .86 FACTOR.PLEASE | | | REVISE.CHECK ALL OPENINGS AS THERE MAY BE OTHER | | | ERRORS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-06 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-06 |
Time |
15:13 |
Sent To |
B |
|
| Notes |
| 2007-09-06 15:13:31 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-27 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-27 |
Time |
15:40 |
Sent To |
B |
|
| Notes |
| 2007-08-27 15:41:00 | TO "SHILL' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-02 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-02 |
Time |
13:35 |
Sent To |
B |
|
| Notes |
| 2007-08-02 13:35:26 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-06 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-25 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2007-06-25 14:36:53 | TO "MISC' BOX#1 |
|
|