 |
Plan Review Details - Permit 07060707
| Plan Review Stops For Permit 07060707 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2008-05-05 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-05-05 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-05-05 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2008-05-05 11:23:44 | NEW SITE ADDRESS TO USE IS 3100 N MILITARY TRL ALONG | | | WITH THE EXISTING PCN FOR 3200 N MILITARY TRL .AT THE | | | TIME WHEN THE NEW PARCEL CONTROL NUMBER IS ISSUED BY | | | THE PROPERTY APPRAISER , THE ADDRESS BE ATTACHED TO THE | | | NEW PCN. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2008-02-07 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-02-07 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-02-07 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2008-02-07 08:48:38 | ***FAILED*** | | | | | | THE UOT( UNITY OF TITLE)MUST BE RECORDED AND PROPERTY | | | APPRAISER'S OFFICE MUST ASSIGN A NEW PARCEL CONTROL | | | NUMBER FOR ALL UNIFIED PARCELS PRIOR OF THE NEW SITE | | | ADDRESS TO BE RELEASED. | | | | | | QUESTIONS/COMMENTS: | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-09-06 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-08-02 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2007-09-06 09:46:25 | FOR THE NEW BUILDING TO BE BUILD A NEW SITE ADDRESS IS | | | REQUIRED.PRIOR OF RELEASING THE SITE ADDRESS THE UNITY | | | OF TITLE OR REPLAT IS NECESSARY FOR ALL PARCELS PART OF | | | THIS PROJECT. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | 2007-07-03 11:52:07 | NEEDS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2009-09-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-09-01 |
Time |
13:44 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2009-09-01 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2009-09-01 13:26:00 | ARCHITECUTRAL REVISION# 12, 7-20-09 | | | | | | A-001 | | | A-010 | | | A-011 | | | A-012 | | | A-100 | | | A-100A | | | A-400 | | | A-401 | | | | | | FIRE SPRINKLER PLAN REVISION# 7 | | | FIRE SPRINKLER PERMIT# 08110219 | | | NOTE THE MAIN FIRE SPRINKLERS TO BE IN BEFORE C.O. | | | FP-102 | | | FP-103 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2009-06-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-06-30 |
Time |
09:30 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2009-06-30 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2009-06-30 09:25:30 | REVISION, SHEETS: | | | A-010 | | | A-012 | | | A-100 | | | A-100A | | | A-101 | | | A-103 | | | A-400 | | | A-900 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2009-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-02-06 |
Time |
14:42 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-02-06 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2009-02-06 14:43:28 | STEEL BAR JOIST AND ENGINEERING CALCS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2009-01-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-01-02 |
Time |
14:29 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-01-02 |
Time |
14:20 |
Sent To |
PC |
|
| Notes |
| 2009-01-02 14:30:08 | SUBMITTAL: SHORING DRAWINGS FOR SMALL MEZZANINE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2008-12-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-12-30 |
Time |
15:56 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2008-12-30 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2008-12-30 16:02:53 | REVISION:# 7 REVIEWED WITH EXCEPTION TO PREVIOUS | | | REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2008-12-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-12-29 |
Time |
15:41 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2008-12-29 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2008-12-29 16:57:15 | BUILDING PLAN REVIEW | | | PERMIT: 07060707 | | | ADD: 3100 N MILITARY TRAIL | | | CONT: ANDERSON MOORE | | | TEL: (561)753-7400 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW: REVISION# 7 / DATE 11-07-08 | | | ACTION: DENIED | | | SHEETS: A-100, A-100A, A-101 & A-103. | | | | | | 1) A-100 , A101& A-101A ALL INDICATE DOOR# 170 (D-G) AS | | | A 1 1/2 HOUR FIRE RATED DOOR BUT THE DOOR SCHEDULE ON | | | SHEET A900 INDICATE THESE DOORS TO BE INSTALLED WITH | | | DOUBLE ACTION DOOR HINGES. TABLE 302.3.2 DOES INDICATE | | | TWO HOUR WALLS ARE REQUIRED AND THE PLANS INDICATE AS | | | SUCH BUT THE DOOR OPENINGS REQUIRE OPENING PROTECTION. | | | TABLE 715.3 INDICATES THE DOOR OPENINGS TO HAVE A 1 1/2 | | | HR FIRE RATING. | | | | | | THERE ARE THREE ISUES WITH THE DOUBLE ACTION TYPE DOOR: | | | | | | 1A) SECTION 715.3.3 FIRE DOOR ASSEMBLIES SHALL ALSO | | | MEET THE THE REQUIREMENTS FOR A SMOKE AND DRAFT CONTROL | | | DOOR ASSEMBLY TESTED IN ACCORDANCE WITH UL 1784 WITH AN | | | ARTIFICIAL BOTTOM SEAL INSTALLED ACROSS THE FULL BOTTOM | | | OF THE DOOR ASSEMBLY. | | | | | | 1B) 15.3.7 DOOR CLOSING. FIRE DOORS SHALL BE | | | SELF-CLOSING OR AUTOMATIC-CLOSING IN ACCORDANCE WITH | | | THIS SECTION. | | | | | | 1C)715.3.7.1 LATCH REQUIRED. UNLESS OTHERWISE | | | SPECIFICALLY PERMITTED, SINGLE FIRE DOORS AND BOTH | | | LEAVES OF PAIRS OF SIDE-HINGED SWINGING FIRE DOORS | | | SHALL BE PROVIDED WITH AN ACTIVE LATCH BOLT THAT WILL | | | SECURE THE DOOR WHEN IT IS CLOSED. | | | | | | 2) SHEET A103 DOOR OPENING # 165 B & C: | | | | | | 2A) DOOR# 165C IS INDICATED IN THE DOOR SCHEDULE AS A 1 | | | 1/2 HR RATED DOOR AND FRAME. THE DOOR SCHEDULE SHEET | | | A900 INDICATES THIS TO BE DOOR TYPE "D" PLANS DO NOT | | | INDICATE THE SIZE OF THE GLAZED WINDOW TABLE 715.4.3. | | | INDICATES FOR A 1 1/2 HR OPENING PROTECTIVE THE MAXIMUM | | | SIXE OF WIRE GLASS IS 100 SQ INCHES OR HEIGHTH 33" AND | | | WIDTH 10". PLEASE PROVIDE THIS INFORMATION ON THE | | | PLANS, DOOR SCHEDULE. | | | | | | 2B) DOOR # 165B IS A STORAGE ROOM WITHIN A STORAGE ROOM | | | , WHY DOES THIS DOOR INDICATE A FIRE RATING PLEASE SEE | | | DOOR SCHEDULE A900.ADDDITIONAL INFORMATION REQUIRED | | | 106.1.2. | | | | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-09 |
Time |
08:44 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-09-09 |
Time |
08:44 |
Sent To |
PC |
|
| Notes |
| 2008-09-09 08:54:52 | PEGGY ADAMS ANIMAL | | | RESCUE LEAGUE | | | 3200 N MILITARY TRAIL | | | BUILDING PLAN REVIEW | | | PERMIT: 07060707 | | | ADD: 3200 N MILITARY TRAIL | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | ISSUED PLANS | | | BUILDING PROVISOS: | | | | | | 1) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL | | | OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 2) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW | | | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO | | | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION | | | SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE | | | DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR | | | SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS | | | WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED | | | SHALL BE SUBJECT TO A FINE NOT TO EXCEED $500.00. IN | | | ADDITION TO THE ABOVE, A LICENSED CONTRACTOR WHO | | | VIOLATES THIS SECTION SHALL BE SUBJECT TO DISCIPLINE | | | PURSUANT TO SECTION 113 OF THIS CHAPTER. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | 07060707 | | | ROOFING NOTES/ NO ROOFING CONTRACTOR SIGNED ON AT TIME | | | OF ISSUANCE | | | MODIFIED BIT FL644-R3 + ENHANCED FASTENING NOA | | | 07-0228.04 JOHN MANVILLE MODIFIED | | | ZONE 1-P13 SYSTEM B(4) | | | ZONE 2-P 9 SYSTEMB(2) | | | ZONE 3 ENHANCED FASTENING | | | ROOF TILE FL601-R2MONIER LIFETIME NOA07-1023.09 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2008-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-22 |
Time |
10:24 |
Rev Time |
7.77 |
| Received By |
jwitmer |
Date |
2008-08-22 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2008-08-22 10:33:42 | PEGGY ADAMS ANIMAL | | | RESCUE LEAGUE | | | 3200 N MILITARY TRAIL | | | BUILDING PLAN REVIEW | | | PERMIT: 07060707 | | | ADD: 3200 N MILITARY TRAIL | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4TH REVIEW | | | ACTION: DENIED | | | | | | PLANS APPEAR TO BE CODE COMPLIANT WILL BE ABLE TO PASS | | | AFTER IMPACT FEE ASSESSMENT. | | | | | | 1) BUILDING PROVISO: WILL REQUIRE NEW PRODUCT APPROVAL | | | COVER SHEET FROM THE ARCHITECT OF RECORD SIGNED AND | | | SEALED LISTING REVIEWED & AND APPROVED PRODUCT | | | APPROVALS. | | | | | | 2) BUILDING PROVISO: FL S S 713.13 NOTICE OF | | | COMMENCEMENT, TO BE FILED WITH THE CLERK OF THE COURT. | | | NOTE: 713.24(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3) BUILDING PROVISO FBC BUILDING 3110.1.2 / CITY OF WPB | | | CODE OF ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED | | | IN AN "A-8" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE | | | WILL BE REQUIRED. BASE FLOOD 16.00+ .5'= 16.5'. | | | | | | 4) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL | | | OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATION FROM A LICENSED ENGINEER SHALL BE | | | SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL | | | OF THE FINAL INSPECTION. | | | | | | 5) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW | | | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO | | | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION | | | SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE | | | DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND | | | DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. ANY PERSONS WHO FAILS TO COMPLY TO REMOVE OR | | | SECURE THE CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS | | | WITHIN 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED | | | SHALL BE SUBJECT TO A FINE NOT TO EXCEED $500.00. IN | | | ADDITION TO THE ABOVE, A LICENSED CONTRACTOR WHO | | | VIOLATES THIS SECTION SHALL BE SUBJECT TO DISCIPLINE | | | PURSUANT TO SECTION 113 OF THIS CHAPTER. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-06 |
Time |
13:24 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2008-06-06 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2008-06-06 13:53:53 | PEGGY ADAMS ANIMAL | | | RESCUE LEAGUE | | | 3200 N MILITARY TRAIL | | | BUILDING PLAN REVIEW | | | PERMIT: 07060707 | | | ADD: 3200 N MILITARY TRAIL | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) .FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.24(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3-6) COMPLIED. | | | | | | 7A)COMPLIED. | | | | | | 7B) COMPLIED. | | | 8) PROVISO: A-8FLOOD ZONEELE CERTIFICATE MINIMUM | | | BASE FLOOD ELEVATION 16.5'. | | | | | | 9) BUILDING PROVISO: 109.3.10 IMPACT OF CONSTRUCTION. | | | | | | 10) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. | | | | | | 11) COMPLIED. | | | | | | 10A-C) COMPLIED. | | | | | | 11) COMPLIED. | | | | | | 12) COMMENT DELETED. | | | | | | 13-14) COMPLIED. | | | | | | 15A) 2ND REQUEST, | | | | | | 15B) WINDOWS IN THE PRE-OP AND POST-OP (4) ARE WITHIN | | | THE 2 HR RATED WALL A-903 WINDOW SCHEDULE WINDOW# 18 NO | | | FIRE RATING IS INDICATED. TABLE 715.3 & TABLE 715.4. | | | | | | NO COMMENT RESPONCES AFTER 15B. | | | | | | | | | 15C) COMPLIED. | | | | | | 16) COMPLIED. | | | | | | 17) 3RDREQUEST, 435.5.1 SHIELDING. EACH X-RAY | | | FACILITY SHA 435.5.1 SHIELDING. EACH X-RAY FACILITY | | | SHALL HAVE PRIMARY AND SECONDARY PROTECTIVE BARRIERS AS | | | NEEDED TO ASSURE THAT AN INDIVIDUAL WILL NOT RECEIVE A | | | RADIATION DOSE IN EXCESS OF THE LIMITS SPECIFIED IN | | | PART III OF CHAPTER 64 E-5, FLORIDA ADMINISTRATIVE CODE | | | . CONTACT: TOM TOMCZAK (904) 278-5730 | | | 705 ROSE RD SUITE# 300 | | | ORANGE PARK, FL 32073 | | | | | | 435.5.1.1 | | | STRUCTURAL SHIELDING IN WALLS AND OTHER VERTICAL | | | BARRIERS REQUIRED FOR PERSONNEL PROTECTION SHALL EXTEND | | | WITHOUT BREACH FROM THE FLOOR TO A HEIGHT OF AT LEAST 7 | | | FEET (2.1 M). | | | 435.5.1.2 | | | DOORS, DOOR FRAMES, WINDOWS AND WINDOW FRAMES SHALL | | | HAVE THE SAME LEAD EQUIVALENT SHIELDING AS THAT | | | REQUIRED IN THE WALL OR OTHER BARRIER IN WHICH THEY ARE | | | INSTALLED. | | | 435.5.1.3 | | | PRIOR TO CONSTRUCTION, THE FLOOR PLANS AND EQUIPMENT | | | ARRANGEMENT OF ALL NEW INSTALLATIONS, OR MODIFICATIONS | | | OF EXISTING INSTALLATIONS, UTILIZING X-RAY ENERGIES OF | | | 200 KEV AND ABOVE FOR DIAGNOSTIC OR THERAPEUTIC | | | PURPOSES SHALL BE SUBMITTED TO THE DEPARTMENT OF HEALTH | | | FOR REVIEW AND APPROVAL. IN COMPUTATION OF PROTECTIVE | | | BARRIER REQUIREMENTS, THE MAXIMUM ANTICIPATED WORKLOAD, | | | USE FACTORS, OCCUPANCY FACTORS AND THE POTENTIAL FOR | | | RADIATION EXPOSURE FROM OTHER SOURCES SHALL BE TAKEN | | | INTO CONSIDERATION. | | | 435.5.1.3.1 | | | THE PLANS SHALL SHOW, AS A MINIMUM, THE FOLLOWING: | | | 435.5.1.3.1.1 THE NORMAL LOCATION OF THE X-RAY SYSTEM?S | | | RADIATION PORT; THE PORT?S TRAVEL AND TRAVERSE LIMITS; | | | GENERAL DIRECTION OF THE USEFUL BEAM; LOCATIONS OF ANY | | | WINDOWS AND DOORS; THE LOCATION OF THE OPERATOR?S | | | BOOTH; AND THE LOCATION OF THE X-RAY CONTROL PANEL. | | | 435.5.1.3.1.2 THE STRUCTURAL COMPOSITION AND THICKNESS | | | OR LEAD EQUIVALENT OF ALL WALLS, DOORS, PARTITIONS, | | | FLOOR AND CEILING OF THE ROOM CONCERNED. 435.5.1.3.1.3 | | | THE DIMENSIONS OF THE ROOM CONCERNED. 435.5.1.3.1.4 THE | | | TYPE OF OCCUPANCY OF ALL ADJACENT AREAS INCLUSIVE OF | | | SPACE ABOVE AND BELOW THE ROOM CONCERNED. IF THERE IS | | | AN EXTERIOR WALL, THE DISTANCE TO THE CLOSEST AREA | | | WHERE IT IS LIKELY THAT INDIVIDUALS MAY BE PRESENT. | | | 435.5.1.3.1.5 THE MAKE AND MODEL OF THE X-RAY EQUIPMENT | | | AND THE MAXIMUM TECHNIQUE FACTORS. | | | 435.5.1.3.1.6 THE TYPE OF EXAMINATIONS OR TREATMENTS | | | WHICH WILL BE PERFORMED WITH THE EQUIPMENT. LL HAVE | | | PRIMARY AND SECONDARY PROTECTIVE BARRIERS AS NEEDED TO | | | ASSURE THAT AN INDIVIDUAL WILL NOT RECEIVE A RADIATION | | | DOSE IN EXCESS OF THE LIMITS SPECIFIED IN PART III OF | | | CHAPTER 64 E-5, FLORIDA ADMINISTRATIVE CODE . | | | | | | 18-21) COMPLIED. | | | | | | 22) COMPLIED. | | | | | | 23) SEMI-COMPLIED. THE DESIGNER OF RECORD DOES INDICATE | | | REVIEW OF PRODUCTS LISTED IN A TITLE PAGE AND SIGNED | | | TITLE PAGE IN BLUE INK BUT DID NOT SEAL THE TITLE | | | PAGE. | | | | | | 24) COMPLIED. | | | | | | 25) 2ND REQUEST,FL BLD CODE 1609.1.4: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT | | | INSPECTOR OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | | | | 25I) 2ND REQUEST, ROOFING ASSEMBLIES- FLAT ROOF, THE | | | NOA SUBMITTED AND SUB-SYSTEM HIGHLIGHTED IS FOR A | | | CONCRETE DECK NOT A STEEL DECKWITH INSULATION, ALL OF | | | THE SUB-SYSTEMS LISTED IN THIS NOA ARE FOR CONCRETE | | | DECKS EITHER INSULATION OR NOT. | | | | | | 25I)2ND REQUEST, ROOFINFG ASSEMBLIES- CONCRETE TILE | | | ROOFING, (2) MONIER TILE SUBMITTED IN BOTH CASES, THE | | | CONTRACTOR DID NOT INDICATE AS TO HOW THE ROOF TILE | | | WERE TO BE ATTACHED TO RESIST THE MOMENT OF | | | OVERTURNING. | | | | | | 25K) NO PRODUCT APPROVALS SUBMITTED FOR PRE-ENGINEERED | | | A/C STANDS | | | | | | 25L) EXTERIOR COOLERS-BEFORE THIS REVIEW IT WAS NOT | | | CLEAR IF THIS UNIT WAS TO BE CONSIDERED ON THE EXTERIOR | | | OF THE BUILDING. | | | | | | 26) SEMI- COMPLIED SEE ABOVE ( 25I). | | | | | | 27) 2ND REQUEST,BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | NEW COMMENTS OFTIME OF THE 2ND REVIEW: | | | | | | 28) 2ND REQUEST, SHEET A-304 VARIOUS SECTIONS INDICATE | | | THE USE OF 1/2 INCH PLYWOOD OVER 3 INCH RIGID | | | INSULATION OVER A METAL DECK. THIS BUILDING TYPE IS | | | DECLARED A TYPE II-B STRUCTURE, PLEASE SEE TABLE 601 | | | FOOTNOTE (C) (2) REQUIRING THE ROOFING TO BE FIRE | | | RETARDANT TREATED WOOD. | | | | | | 29) SHEET S-302ALSO INDICATES THE USE OF WOOD TRUSSES | | | BEAMS IN THE SAME BASIC DETAIL NUMBER 2 & 3INDICATES | | | WOOD TRUSSES? THIS BUILDING TYPE IS DECLARED A TYPE | | | II-B STRUCTURE, PLEASE SEE TABLE 601 FOOTNOTE (C) (2) | | | REQUIRING THE ROOFING TO BE FIRE RETARDANT TREATED | | | WOOD. | | | | | | 30) SHEET S-419 INDICATES THE USE OF STRUCTURAL GLAZED | | | FACING TILE, PLEASE PROVIDE INFORMATION FROM THE | | | MANUFACTURER. 106.1.2 ADDITONAL INFORMATION REQUIRED. | | | PLEASE CORRECT ALL SHEETS WHERE WOOD TRUSSES OR WOOD | | | BEAMS ARE WITHIN THE BUILDING FRAMING OR RECLASSIFY THE | | | BUILDING TYPE THAT WOULD MEET THE ALLOWABLE SQUARE | | | FOOTAGE AND OCCUPANCY WITH WOOD FRAMING MEMBERS. | | | | | | 31)COMPLIED. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-02-19 |
Time |
16:15 |
Rev Time |
5.55 |
| Received By |
jwitmer |
Date |
2008-02-19 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2008-02-19 16:32:35 | PEGGY ADAMS ANIMAL | | | RESCUE LEAGUE | | | 3200 N MILITARY TRAIL | | | BUILDING PLAN REVIEW | | | PERMIT: 07060707 | | | ADD: 3200 N MILITARY TRAIL | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) .FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.24(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3-6) COMPLIED. | | | | | | 7A) 2ND REQUEST,THE RESPONSE SHEET INDICATES THE | | | RESIDENT INSPECTOR INFORMATION PACKET IS PART OF THE | | | RESUBMITTAL, DIDN'T LOCATE IT.FBC* 109.3.7RESIDENT | | | INSPECTOR. SUBMIT INSPECTOR RESUME' AND LICENSE | | | DOCUMENTS TO HAROLD PISKURA, DIRECTOR OF THE RESIDENT | | | INSPECTOR PROGRAM.A RESIDENT INSPECTOR PROGRAM IS | | | REQUIRED, ON THIS PROJECT, DUE TO ONE OR MORE OF THE | | | FOLLOWING: | | | XXX - BUILDINGS/ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | - ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE | | | DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | XXX- BUILDINGS OVER 20,000 SQ FT IN AREA (35,772 SQ | | | FT) | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | - BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 7B) THREE SETS OF PLANS, PRODUCT APPROVALS AND OTHER | | | REPORTS WILL BE REQUIRED FOR A RESIDENT INSPECTOR. SEE | | | 109.3.7. | | | | | | 8) PROVISO: A FLOOD ZONECERTIFICATE WILL BE REQUIRED | | | SINCE THIS BUILDING IS LOCATED IN A A-8 FLOOD ZONE. | | | THIS DOCUMENT WILL BE REQUIRED BEFORE THE ISSUANCE OF | | | ANY C. O. | | | | | | 9) BUILDING PROVISO: 109.3.10 IMPACT OF CONSTRUCTION. | | | | | | 10) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. | | | | | | 11) COMPLIED. | | | | | | 10A-C) COMPLIED. | | | | | | 11) 2ND REQUEST,PLEASE SEE A-100 AND A-101 THE MAIN | | | LOBBY (101) & SURRENDER LOBBY (180) PROVIDE DETAILS | | | SHOWING COMPLIANCE WITH 11-7.2(1) SERVICE COUNTERS WITH | | | ELEVATIONS OF 36".SEE DETAILS ON SHEET A-713 DETAILS | | | 103-105. | | | | | | 12) COMMENT DELETED. | | | | | | 13-14) COMPLIED. | | | | | | 15A) 2ND REQUEST, | | | | | | 15B) 2ND REQUEST, THE EQUIVALENT THICKNESS OF THE | | | MASONARY UNITS WOULD BE THICKERTHAN INDICATESD ON THE | | | LIFE SAFETY PLAN.THE LIFE SAFETY PLAN ALSO INDICATES | | | AROUND THE KENNEL OCCUPANCY WHEREAS NEITHER OF THE | | | SHEETS A-100 OR A-101 PROVIDE ANY WALL TAGS INDICATING | | | A 2HR SEPARATION. PLEASE PROVIDE THE EQUIVALENT | | | THICKNESS FOR CONCRETE BLOCK FROM THE MANUFACTURER | | | INDICATING THE EQUIVALENT THICKNESS 721.3.2. | | | | | | 15C) COMPLIED. | | | | | | 16) COMPLIED. | | | | | | 17) 2ND REQUEST, 435.5.1 SHIELDING. EACH X-RAY FACILITY | | | SHA 435.5.1 SHIELDING. EACH X-RAY FACILITY SHALL HAVE | | | PRIMARY AND SECONDARY PROTECTIVE BARRIERS AS NEEDED TO | | | ASSURE THAT AN INDIVIDUAL WILL NOT RECEIVE A RADIATION | | | DOSE IN EXCESS OF THE LIMITS SPECIFIED IN PART III OF | | | CHAPTER 64 E-5, FLORIDA ADMINISTRATIVE CODE . CONTACT: | | | TOM TOMCZAK (904) 278-5730 | | | 705 ROSE RD SUITE# 300 | | | ORANGE PARK, FL 32073 | | | | | | 435.5.1.1 | | | STRUCTURAL SHIELDING IN WALLS AND OTHER VERTICAL | | | BARRIERS REQUIRED FOR PERSONNEL PROTECTION SHALL EXTEND | | | WITHOUT BREACH FROM THE FLOOR TO A HEIGHT OF AT LEAST 7 | | | FEET (2.1 M). | | | 435.5.1.2 | | | DOORS, DOOR FRAMES, WINDOWS AND WINDOW FRAMES SHALL | | | HAVE THE SAME LEAD EQUIVALENT SHIELDING AS THAT | | | REQUIRED IN THE WALL OR OTHER BARRIER IN WHICH THEY ARE | | | INSTALLED. | | | 435.5.1.3 | | | PRIOR TO CONSTRUCTION, THE FLOOR PLANS AND EQUIPMENT | | | ARRANGEMENT OF ALL NEW INSTALLATIONS, OR MODIFICATIONS | | | OF EXISTING INSTALLATIONS, UTILIZING X-RAY ENERGIES OF | | | 200 KEV AND ABOVE FOR DIAGNOSTIC OR THERAPEUTIC | | | PURPOSES SHALL BE SUBMITTED TO THE DEPARTMENT OF HEALTH | | | FOR REVIEW AND APPROVAL. IN COMPUTATION OF PROTECTIVE | | | BARRIER REQUIREMENTS, THE MAXIMUM ANTICIPATED WORKLOAD, | | | USE FACTORS, OCCUPANCY FACTORS AND THE POTENTIAL FOR | | | RADIATION EXPOSURE FROM OTHER SOURCES SHALL BE TAKEN | | | INTO CONSIDERATION. | | | 435.5.1.3.1 | | | THE PLANS SHALL SHOW, AS A MINIMUM, THE FOLLOWING: | | | 435.5.1.3.1.1 THE NORMAL LOCATION OF THE X-RAY SYSTEM?S | | | RADIATION PORT; THE PORT?S TRAVEL AND TRAVERSE LIMITS; | | | GENERAL DIRECTION OF THE USEFUL BEAM; LOCATIONS OF ANY | | | WINDOWS AND DOORS; THE LOCATION OF THE OPERATOR?S | | | BOOTH; AND THE LOCATION OF THE X-RAY CONTROL PANEL. | | | 435.5.1.3.1.2 THE STRUCTURAL COMPOSITION AND THICKNESS | | | OR LEAD EQUIVALENT OF ALL WALLS, DOORS, PARTITIONS, | | | FLOOR AND CEILING OF THE ROOM CONCERNED. 435.5.1.3.1.3 | | | THE DIMENSIONS OF THE ROOM CONCERNED. 435.5.1.3.1.4 THE | | | TYPE OF OCCUPANCY OF ALL ADJACENT AREAS INCLUSIVE OF | | | SPACE ABOVE AND BELOW THE ROOM CONCERNED. IF THERE IS | | | AN EXTERIOR WALL, THE DISTANCE TO THE CLOSEST AREA | | | WHERE IT IS LIKELY THAT INDIVIDUALS MAY BE PRESENT. | | | 435.5.1.3.1.5 THE MAKE AND MODEL OF THE X-RAY EQUIPMENT | | | AND THE MAXIMUM TECHNIQUE FACTORS. | | | 435.5.1.3.1.6 THE TYPE OF EXAMINATIONS OR TREATMENTS | | | WHICH WILL BE PERFORMED WITH THE EQUIPMENT. LL HAVE | | | PRIMARY AND SECONDARY PROTECTIVE BARRIERS AS NEEDED TO | | | ASSURE THAT AN INDIVIDUAL WILL NOT RECEIVE A RADIATION | | | DOSE IN EXCESS OF THE LIMITS SPECIFIED IN PART III OF | | | CHAPTER 64 E-5, FLORIDA ADMINISTRATIVE CODE . | | | | | | 18-21) COMPLIED. | | | | | | 22) COMPLIED. | | | | | | 23) SEMI-COMPLIED. THE DESIGNER OF RECORD DOES INDICATE | | | REVIEW OF PRODUCTS LISTED IN A TITLE PAGE AND SIGNED | | | TITLE PAGE IN BLUE INK BUT DID NOT SEAL THE TITLE | | | PAGE. | | | | | | 24) COMPLIED. | | | | | | 25) 2ND REQUEST,FL BLD CODE 1609.1.4: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES, 3 IF THRESHOLD OR RESIDENT | | | INSPECTOR OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | | | | 25I) ROOFING ASSEMBLIES- FLAT ROOF, THE NOA SUBMITTED | | | AND SUB-SYSTEM HIGHLIGHTED IS FOR A CONCRETE DECK NOT A | | | STEEL DECKWITH INSULATION, ALL OF THE SUB-SYSTEMS | | | LISTED IN THIS NOA ARE FOR CONCRETE DECKS EITHER | | | INSULATION OR NOT. | | | | | | 25I) ROOFINFG ASSEMBLIES- CONCRETE TILE ROOFING, (2) | | | MONIER TILE SUBMITTED IN BOTH CASES, THE CONTRACTOR DID | | | NOT INDICATE AS TO HOW THE ROOF TILE WERE TO BE | | | ATTACHED TO RESIST THE MOMENT OF OVERTURNING. | | | | | | 25K) NO PRODUCT APPROVALS SUBMITTED FOR PRE-ENGINEERED | | | A/C STANDS | | | | | | 25L) EXTERIOR COOLERS-BEFORE THIS REVIEW IT WAS NOT | | | CLEAR IF THIS UNIT WAS TO BE CONSIDERED ON THE EXTERIOR | | | OF THE BUILDING. | | | | | | 26) SEMI- COMPLIED SEE ABOVE ( 25I). | | | | | | 27) 2ND REQUEST,BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | NEW COMMENTS: | | | | | | 28) SHEET A-304 VARIOUS SECTIONS INDICATE THE USE OF | | | 1/2 INCH PLYWOOD OVER 3 INCH RIGID INSULATION OVER A | | | METAL DECK. THIS BUILDING TYPE IS DECLARED A TYPE II-B | | | STRUCTURE, PLEASE SEE TABLE 601 FOOTNOTE (C) (2) | | | REQUIRING THE ROOFING TO BE FIRE RETARDANT TREATED | | | WOOD. | | | | | | 29) SHEET S-114 ALSO INDICATES THE USE OF WOOD BEAMS IN | | | THE SAME BASIC DETAIL NUMBER 43 & 44 THERE IS A | | | DISCREPANCY, ONE INDICATES A CONVENTIONAL WOOD FRAME | | | ROOF WHILE THE OTHER INDICATES WOOD TRUSSES? THIS | | | BUILDING TYPE IS DECLARED A TYPE II-B STRUCTURE, PLEASE | | | SEE TABLE 601 FOOTNOTE (C) (2) REQUIRING THE ROOFING TO | | | BE FIRE RETARDANT TREATED WOOD. | | | | | | 30) SHEET S-419 INDICATES THE USE OF STRUCTURAL GLAZED | | | FACING TILE, PLEASE PROVIDE INFORMATION FROM THE | | | MANUFACTURER. 106.1.2 ADDITONAL INFORMATION REQUIRED. | | | | | | 31) PLEASE PROVIDE A UNITY OF TITLE FOR ALL OF THE | | | LOTS,UNITY OF TITLE. THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES BETWEEN THE LOTS | | | WHICH COMBINE TO FORM 'THE SITE'.A 'UNITY OF TITLE' | | | SHALL BE RECORDED AT THE COUNTY COURTHOUSE. SUBMIT A | | | COPY OF THE RECORDED 'UNITY OF OF TITLE' DOCUMENT SO | | | THAT FBC TABLE 601 BOUNDARY LINE REQUIREMENTS MAY BE | | | DEEMED | | | NOT APPLICABLE. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
10:47 |
Rev Time |
12.12 |
| Received By |
jwitmer |
Date |
2007-08-03 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2007-08-06 21:32:27 | PEGGY ADAMS ANIMAL | | | RESCUE LEAGUE | | | 3200 N MILITARY TRAIL | | | BUILDING PLAN REVIEW | | | PERMIT: 07060707 | | | ADD: 3200 N MILITARY TRAIL | | | CONT: ANDERSON MOORE | | | TEL: (561)662-1819 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) SHEET G-001 THE CIVIL ENGINEER CIVIL DESIGN, INC. IS | | | MISSING THEIR CERTIFICATE OF AUTHORIZATION. 471.023 | | | F.S.CERTIFICATE OF AUTHORIZATION.THE TITLE BLOCK | | | FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER PRACTICING UNDER | | | A FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP, | | | OFFERING ENGINEERING SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. ADD THE NUMBER TO | | | EACH SHEET.THIS MAY BE ADDED BY HAND. | | | | | | 4) SHEET G-001 THE LANDSCAPE ARCHITECT ALSO IS MISSING | | | THEIR CERTIFICATE OF AUTHORIZATION. ) 481.219 F.S. | | | CERTIFICATE OF AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ARCHITECT PRACTICING UNDER | | | A FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP, | | | OFFERING ARCHITECTURAL SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER.ADD THE NUMBER TO | | | EACH SHEET. THIS MAY BE ADDED BY HAND. | | | | | | 5) SHEET G-001 SITE BUILDING DATA INDICATES THIS | | | PROJECT IS LOCATED IN A **FIRE ZONE**, | | | THERE ARE NO LONGER FIRE ZONES IN THE BUILDING CODE. | | | | | | 6) PLEASE PROVIDE ORIGINAL SIGNATURE SOILS REPORTS. FBC | | | 1802.2.1 QUESTIONABLE SOILS, WHERE THE SAFE-SUSTAINING | | | POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING | | | VALUE SUPERIOR TO THAT SPECIFIED IN THIS CODE IS | | | CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT THE | | | NECESSARY INVESTIGATION BE MADE. SUCH INVESTIGATION | | | SHALL COMPLY WITH THE PROVISIONS OF SECTIONS 1802.4 | | | THROUGH 1802.6 . | | | | | | 7) FBC* 105.3RESIDENT INSPECTOR. SUBMIT INSPECTOR | | | RESUME' AND LICENSE DOCUMENTS TO HAROLD PISKURA, | | | DIRECTOR OF THE RESIDENT INSPECTOR PROGRAM.A RESIDENT | | | INSPECTORPROGRAM IS REQUIRED, ON THIS PROJECT, DUE TO | | | ONE OR MORE OF THE FOLLOWING: | | | XX - BUILDINGS/ADDITIONS OF TYPE I OR II CONSTRUCTION - | | | ANY MAJOR STRUCTURAL ALTERATIONS | | | - STRUCTURES IN WHICH THE CONCRETE DESIGN IS | | | BASED ON COMPRESSIVE | | | STRENGTH (F'C) IN EXCESS OF 3000 PSI | | | - PILE DRIVING | | | XX- BUILDINGS OVER 20,000 SQ FT IN AREA( 35,772 SQ | | | FT) | | | - BUILDINGS OVER 2 STORIES IN HEIGHT | | | XX- BUILDING/STRUCTURES OF UNUSUAL DESIGN | | | OR METHODS OF CONSTRUCTION | | | | | | 8) THIS PROJECT IS LOCATED IN A A-8FLOOD ZONE WITH | | | THE FINISH FLOOR ELEVATION OF 16.5? MINIMUM FINISH | | | FLOOR ELEVATION AND ANY MECHANICAL EQUIPMENT ON THE | | | EXTERIOR OF THE BUILDING BE ABOVE THIS SAME ELEVATION. | | | PROVIDE FLOOD ZONE ELEVATION CERTIFICATE FOR NEW | | | CONSTRUCTION BEFORE A CERTIFICATE OF OCCUPANCY WILL BE | | | ISSUED. | | | | | | 9) 109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | | ADJACENTPROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED | | | TO AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | | INCLUDES BUT IS NOT LIMITED TO THE CONTROL OF DUST, | | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATE FROM A LICENSED ENGINEER SHALL BE SUBMITTED | | | TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE | | | FINAL INSPECTION. | | | | | | 10) 109.3.10.1 HURRICANE PROTECTION. IT SHALL BE | | | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED | | | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. | | | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS,EQUIPMENT AND DEBRIS SHALL BE | | | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN | | | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH | | | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY | | | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE | | | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN 24 | | | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 | | | OF THIS CHAPTER. | | | | | | 11) LS-001 THE LIFE SAFETY PLAN FAILS TO IDENTIFYROOM | | | TYPES, OCCUPANT LOADS FOR ROOMS, | | | OCCUPANT LOADS FOR DOORWAYS. PLEASE SEE TABLE 1004.1& | | | 1005.1. | | | | | | 10) SHEET C-3.1 THE COVERED ENTRY INDICATES THE DRIVE | | | TO BE AT 20.80? WHEREAS THE INTERIOR FINISH FLOOR OF | | | THE LOBBY IS 21.00?. PLEASE PROVIDE A SECTION THROUGH | | | THIS AREA TO PROVIDE THE FOLLOWING: | | | 10A) COMPLIANCE WITH 11-4.6.5 VERTICAL CLEARANCE FOR | | | PASSENGER LOADING ZONE. | | | 10B) PROVIDE A CURB DETAIL INDICATING COMPLIANCE WITH | | | 11-4.6.6 PASSENGER LOADING ZONE. | | | 10C) DEPENDING ON THE 2? CHANGE IN ELEVATION FROM THE | | | PASSENGER LOADING ZONE TO FINISH FLOOR ELEVATIONS CURB | | | CUTS 11-4.7. | | | | | | 11) PLEASE SEE A-100 AND A-101 THE MAIN LOBBY (101) & | | | SURRENDER LOBBY (180) PROVIDE DETAILS SHOWING | | | COMPLIANCE WITH 11-7.2(1) SERVICE COUNTERS WITH | | | ELEVATIONS OF 36?.SEE DETAILS ON SHEET A-713 DETAILS | | | 103-105. | | | | | | 12) COMMENT DELETED. | | | | | | 13)SHEET A-100 & A-103 INDICATES 2 SHOWERS (153 & 155) | | | BOTH ARE TO BE HANDICAPPED ACCESSIBLE. SHOW COMPLIANCE | | | WITH 11-4.21(1-8). | | | | | | 14) SHEET A-101 DOOR 102B IS MISSING THE 18? ON THE | | | PULL SIDE AT LATCH.11-4.13.6 MANEUVERING | | | CLEARENCES AT DOORS. MINIMUM MANEUVERING CLEARANCES AT | | | DOORS THAT ARE NOT AUTOMATIC OR POWER-ASSISTED SHALL BE | | | AS SHOWN IN FIG. 25. THE FLOOR OR GROUND AREA WITH IN | | | THE REQUIRED CLEARANCES SHALL BE CLEAR & LEVEL. | | | | | | 15) THE LIFE SAFETY PLAN INDICATES THERE ARE TWO (2) | | | AREAS WITH 2HR FIRE RATED WALLS: | | | 15A)(1) SALLY PORT, SHEET A-100 & A-103 BOTH ARE | | | MISSING THE WALL TAGS INDICATING THEY ARE 2HR FIRE | | | RATED WALLS. SEE TABLE 303.3.2. BETWEEN S-2 CLOSED | | | GARAGE AND BUSINESS OCCUPANCY. PLEASE PROVIDE THE | | | EQUIVALENT THICKNESS FOR CONCRETE BLOCK FROM THE | | | MANUFACTURER INDICATING THE EQUIVALENT THICKNESS | | | 721.3.2. | | | 15A) (2) SALLY PORT THERE APPEARS TO BE 6 VEHICLES IN | | | THE GARAGE AND 2 LARGE OBJECTS, NOT CLEAR AS TO WHAT | | | THIS IS POSSIBLY STORAGE? | | | | | | | | | 15B) THE LIFE SAFETY PLAN ALSO INDICATES AROUND THE | | | KENNEL OCCUPANCY WHEREAS NEITHER OF THE SHEETS A-100 OR | | | A-101 PROVIDE ANY WALL TAGS INDICATING A 2HR | | | SEPARATION. PLEASE PROVIDE THE EQUIVALENT THICKNESS FOR | | | CONCRETE BLOCK FROM THE MANUFACTURER INDICATING THE | | | EQUIVALENT THICKNESS 721.3.2. | | | | | | 15C) THE LIFE SAFETY SHEET AS WELL AS SHEET A-100 AND | | | A-104 DO NOT INDICATE A 2HR FIRE RATING ON THE MASONRY | | | WALLTABLE 303.3.2 INDICATES BETWEEN A BUSINESS AND | | | R-2 OCCUPANCY WALLS ARE TO BE RATED. THE DOOR SCHEDULE | | | ALSO NEEDS CORRECTING IN THIS MANNER , SEE OPENING | | | PROTECTIVE. TABLE 715.3 | | | | | | 16) SHEET A-100 ROOM 166 INDICATES THIS IS A FREEZER | | | BUT THERE IS A PORTION OF THE WALL THAT IS MISSING, IS | | | THIS A DOORWAY, NEED MORE INFORMATION. 106.1.2 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 17) ROOM 142 INDICATES THIS IS TO BE USED FOR X-RAYS | | | PLEASE PROVIDE COMPLIANCE WITH: | | | 435.5.1 SHIELDING. | | | 435.5.2 X-RAY FILM PROCESSING FACILITIES. | | | | | | 18A) SHEET A-105 MEZZANINE # 1THE PLANS INDICATE THIS | | | TO HAVE A PULL DOWN STAIRWAY LEADING FROM ROOM 133 OR | | | THE TECH AREA. THIS MEZZANINE HAS AN OCCUPANT LOAD OF | | | THREE(3). | | | 505.3 EGRESS WILL ALLOW FOR A SINGLE MEANS OF EGRESS | | | BUT THE CODE DOESN?T INDICATE THAT A PULL DOWN STAIRWAY | | | MEETS EGRESS REQUIREMENTS. THE SECOND ISSUE WITH THE | | | PULL DOWN STAIR IT BLOCKS THE CORRIDOR BELOW. | | | | | | 18B) THE FLOOR HATCH WILL ALSO NEED A GUARD AROUND WHAT | | | EVER ACCESS WILL BE CREATED IN THE FLOOR. 1012.2 | | | HEIGHT. GUARDS SHALL FORM A PROTECTIVE BARRIER NOT LESS | | | THAN 42 INCHES | | | 1012.3 EXCEPTION(2)AT ELEVATED WALKING SURFACES FOR | | | ACCESS TO AND USE OF ELECTRICAL, MECHANICAL OR PLUMBING | | | SYSTEMS OR EQUIPMENT, GUARDS SHALL HAVE BALUSTERS OR BE | | | OF SOLID MATERIALS SUCH THAT A SPHERE WITH A DIAMETER | | | OF 21 INCHES (533 MM) CANNOT PASS THROUGH ANY OPENING. | | | | | | | | | 19A) SHEET A-105 MEZZANINE # 2 INDICATES THE USE OF A | | | VERTICAL SHIPS LADDER. PLEASE SEE MEZZANINE MEANS OF | | | EGRESS, THIS MEZZANINE IS LARGER AND AN OCCUPANT LOAD | | | OF 8. | | | 505.3 EGRESS. | | | 505.3EACH OCCUPANT OF A MEZZANINE SHALL HAVE ACCESS TO | | | AT LEAST TWO INDEPENDENT MEANS OF EGRESS WHERE THE | | | COMMON PATH OF EGRESS TRAVEL EXCEEDS THE LIMITATIONS OF | | | SECTION 1013.3 . WHERE A STAIRWAY PROVIDES A MEANS OF | | | EXIT ACCESS FROM A MEZZANINE, THE MAXIMUM TRAVEL | | | DISTANCE INCLUDES THE DISTANCE TRAVELED ON THE STAIRWAY | | | MEASURED IN THE PLANE OF THE TREAD NOSING. | | | | | | 19B) PLANS INDICATE THE GUARD RAIL TO BE 34? TALL, | | | PLEASE SEE. 1012.2 HEIGHT. GUARDS SHALL FORM A | | | PROTECTIVE BARRIER NOT LESS THAN 42 INCHES | | | 1012.3 EXCEPTION(2)AT ELEVATED WALKING SURFACES FOR | | | ACCESS TO AND USE OF ELECTRICAL, MECHANICAL OR PLUMBING | | | SYSTEMS OR EQUIPMENT, GUARDS SHALL HAVE BALUSTERS OR BE | | | OF SOLID MATERIALS SUCH THAT A SPHERE WITH A DIAMETER | | | OF 21 INCHES (533 MM) CANNOT PASS THROUGH ANY OPENING. | | | | | | 20) SHEET A-200 IS THE REFLECTED CEILING PLAN, THE PLAN | | | IS MISSING EXIT LIGHTS, AND DIRECTIONAL, PLEASE UPDATE | | | PLAN SECTION 1006. 1006.1.1 | | | ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THIS SECTION FOR EVERY BUILDING AND | | | STRUCTURE. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT | | | ACCESS SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, | | | CORRIDORS, RAMPS, ESCALATORS AND PASSAGEWAYS LEADING TO | | | AN EXIT. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT | | | DISCHARGE SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, | | | CORRIDORS, RAMPS, ESCALATORS, WALKWAYS AND EXIT | | | PASSAGEWAYS LEADING TO A PUBLIC WAY. | | | | | | 21) SHEET A-300 ROOF DRAINAGE: | | | 21A) THE GARAGE ROOF INDICATES THAT THERE WILL BE | | | THROUGH THE WALL SCUPPERS AND COLLECTORS AND DOWN | | | SPOUTS (R15) THE SAME MARKINGS ARE USED FOR THE | | | EMERGENCY OVERFLOW SCUPPERS. THE EMERGENCY OVERFLOW | | | SCUPPERS ARE NOT TO BE AT THE SAME HEIGHT AS THE | | | SCUPPERS. | | | 1503.4.3 OVERFLOW SCUPPERS. | | | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT | | | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR | | | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 | | | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND | | | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED | | | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET | | | SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. | | | | | | 21B) PLEASE PROVIDE A DETAIL INDICATING THE FOLLOWING: | | | 1503.6 PROTECTION AGAINST DECAY AND TERMITES. | | | CONDENSATE LINES AND ROOF DOWNSPOUTS SHALL DISCHARGE AT | | | LEAST 1 FOOT (305 MM) AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EXTENSIONS, OR | | | SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON | | | ALL BUILDINGS WITH EAVES OF LESS THAN 6 INCHES (152 MM) | | | HORIZONTAL PROJECTION EXCEPT FOR GABLE END RAKES OR ON | | | A ROOF ABOVE ANOTHER ROOF. | | | | | | 21C) SHEET A-300 INDICATES R9 & R11 EMERGENCY OVERFLOWS | | | BUT THE WIDTH IS NOT PROVIDED, AN OVERFLOW SCUPPER | | | SHALL BE SIZED IN ACCORDANCE WITH THE FLORIDA BUILDING | | | CODE, PLUMBING. 1503.4.3.PLEASE PROVIDE SIZES OF THE | | | OVERFLOW SCUPPERS. | | | | | | 22)1609.1.4 PROTECTION OF OPENINGS. IN WIND-BORNE | | | DEBRIS REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE | | | PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS | | | SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF | | | GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE | | | ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES | | | POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH | | | AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS | | | OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE | | | TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1. | | | GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE | | | SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST. | | | 2. GLAZED OPENINGS LOCATED MORE THAN | | | 30 FEET (9.1 M) ABOVE GRADE SHALL MEET THE PROVISIONS | | | OF THE SMALL MISSILE TEST. | | | | | | 23) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 24) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL AREREQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, | | | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR | | | SITE SPECIFIC FORM PER RULE 9B-72. | | | | | | 25) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) | | | OF PRODUCT TESTING REPORTS ,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A)FIXED FRAME, STOREFRONT WINDOWS | | | B) HORIZONTAL OR PASS THRU WINDOWS | | | C) MULLIONS HORIZONTAL OR VERTICAL | | | D) LOUVERS | | | E) GLAZED DOORS | | | F) HOLLOW EXTERIOR METAL DOORS SINGLE AND PAIRS | | | G) OVERHEAD DOORS | | | H) SKYLIGHTS | | | I) ROOFING ASSEMBLIES FLAT ROOFS BUILT UP OR MODIFIED, | | | TILE ROOF AND UNDERLAYMENTS | | | K) PRE-ENGINEERED A/C STANDS | | | | | | 26) THESE ARE THE MOST OFTEN REASONS FOR ROOFING REPORT | | | FAILURES, THIS ROOF IS MISSING OR NOT INCOMPLIANCE | | | WITH THE FOLLOW ITEMS: | | | | | | ___ CONTRACTOR DID NOT PROVIDE THE MEAN ROOF HEIGHT. | | | | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF PITCH. | | | | | | ___ CONTRACTOR FAILED TO INDICATE WHICH SUB-SYSTEM TO | | | BE INSTALLED. | | | | | | ___ THE SYSTEM PROVIDED HAS A LOWPRESSURE FOR ZONE | | | ___ . | | | | | | ___ THE SYSTEM PROVIDED STATES LIMITATION# 7, SHOULD | | | THE FASTENER RESISTANCE BE LESS THAN THAT REQUIRED, AS | | | DETERMINED BY THE BUILDING OFFICIAL, A REVISED FASTENER | | | SPACING, PREPARED , SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER, REGISTERED ARCHITECT | | | OR REGISTERED ROOF CONSULTANT MAY BE SUBMITTED. | | | | | | ___THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO | | | ENHANCED FASTENING ALLOWED. | | | | | | 27) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2009-11-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-11-24 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-11-24 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2009-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-10 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-10 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2009-10-10 10:00:48 | | | | | | | ** DENIED REVIEW ** | | | **ORIGINALLY SUBMITTED 8/13 AND PLACED ON HOLD FOR | | | ELECTRICAL REVIEW AS NEW REVISED SHEETS NEEDED TO BE | | | INSERTED INTO SETS BEFORE REVIEW. | | | OTHER REVISED TRADE SHEETS WERE ALSO INCLUDED WHEN | | | SHEETS WERE INSERTED WHICH ARE DATED AFTER ORIGINAL | | | SUBMITTED DATE. THERE WERE ALSO NEW REVISED PLUMBING | | | SHEETS INSERTED AFTER THE PLUMBING REVIEW WAS DONE. NEW | | | SHEETS ALSO INSERTED THIS WEEK FOR ZONING. | | | ORIGINALLY SUBMITTED AS 28 REVISED SHEETS THERE IS NOW | | | A TOTAL OF 47 REVISED SHEETS IN EACH SET. INCLUDING | | | FIVE REVISED PLUMBING REVISED SHEETS. ADDITIONAL FEE | | | FOR REVISED SHEETS WILL BE DUE. | | | | | | 1) NOTE: AS NOTED PREVIOUSLY. THE SAME ENERGY | | | CALCULATIONS AS PREVIOUSLY SUBMITTED ARE NOT REVISED | | | AND ARE THE SAME AS SUBMITTED. | | | | | | ** PREVIOUS NOTES** | | | ENERGY CALCULATIONS NOT STAMPED FOR ELECTRIC. AS STATED | | | ON PREVIOUS REVIEWS. ALL SYSTEMS AND COMPONENTS IN THE | | | BUILDING AND ON SAID PLANS NEED TO COORDINATE WITH THE | | | INPUT DATA REPORT. AN EXAMPLE IS TAKING A CREDIT FOR | | | ALL ROOMS AND SPACES IN BUILDING TO CONTAIN * CARPET | | | AND RUBBER PADDING*. THE FACT THERE IS NUMEROUS AREAS | | | AND LOCATIONS WITHIN BUILDING WHICH DO NOT CONTAIN THIS | | | TYPE OF FLOORING. THERE ARE ALSO ROOMS AND OTHER AREAS | | | SUCH AS ELECTRICAL ROOMS, MECHANICAL ROOMS, SURGERY | | | ROOMS, STORAGE ROOMS ETC WHICH WILL NOT HAVE ANY CARPET | | | AND RUBBER PADDING. | | | SEE COMMENTS FROM OTHER TRADES. SEE FBC CHAPTER 13 AS | | | THE SUBMITTED CALCULATIONS DO NOT MEET THE MINIMUM OF | | | THE FLORIDA BUILDING CODE IN CHAPTER 13. | | | | | | 2) NOTE: REVISED PLANS SUBMITTED REMOVING PHASE TWO | | | SCOPE OF WORK HOWEVER REVISED CIRCUITING, LOADS AND | | | PANEL SCHEDULES WERE NOT SUBMITTED OR REVISED FOR AREAS | | | WHICH ARE IN THE PHASE ONE SCOPE OF WORK. THERE ARE | | | SEVERAL AREAS WHICH OVER LAP FOR THE ABOVE CIRCUITING | | | ETC. | | | PLEASE SUBMIT REVISED PANEL SCHEDULES PER 408.4 REVISED | | | PANEL SCHEDULES WERE NOT SUBMITTED AS PART OF PHASE TWO | | | SCOPE OF WORK. | | | PLEASE REVISE CIRCUITING AND LOADS PER NEC 220, | | | 220.12,220.14, 220.42 ETC | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2009-06-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-06-29 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-06-29 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2009-06-29 14:30:01 | ** DENIED REVIEW ** | | | | | | 1) NOTE: ENERGY CALCULATIONS NOT STAMPED FOR ELECTRIC. | | | AS STATED ON PREVIOUS REVIEWS. ALL SYSTEMS AND | | | COMPONENTS IN THE BUILDING AND ON SAID PLANS NEED TO | | | COORDINATE WITH THE INPUT DATA REPORT. AN EXAMPLE IS | | | TAKING A CREDIT FOR ALL ROOMS AND SPACES IN BUILDING TO | | | CONTAIN * CARPET AND RUBBER PADDING*. THE FACT THERE IS | | | NUMEROUS AREAS AND LOCATIONS WITHIN BUILDING WHICH DO | | | NOT CONTAIN THIS TYPE OF FLOORING. THERE ARE ALSO ROOMS | | | AND OTHER AREAS SUCH AS ELECTRICAL ROOMS, MECHANICAL | | | ROOMS, SURGERY ROOMS, STORAGE ROOMS ETC WHICH WILL NOT | | | HAVE ANY CARPET AND RUBBER PADDING. | | | SEE COMMENTS FROM OTHER TRADES. SEE FBC CHAPTER 13 AS | | | THE SUBMITTED CALCULATIONS DO NOT MEET THE MINIMUM OF | | | THE FLORIDA BUILDING CODE IN CHAPTER 13. | | | | | | 2) NOTE: NO OTHER ELECTRICAL REVISIONS SUBMITTED TO | | | REVIEW SAID CALCULATIONS AND COORDINATE WITH PLANS. THE | | | NEW REVISED CALCULATIONS DO NOT COORDINATE WITH PLANS | | | ON FILE. | | | | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2009-01-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-01-13 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-01-13 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2009-01-13 16:45:07 | ** DENIED REVIEW OF REVISIONS** | | | | | | ** REVISIONS SUBMITTED 12/11/2008 | | | | | | ELECTRICAL PLANS ARE OK HOWEVER REVIEW TO REMAIN IN | | | FAILED STATUS DUE TO ENERGY CALCULATIONS. | | | | | | | | | | | | | | | | | | 1) NOTE: PLEASE BE SURE ALL INFORMATION REGARDING | | | LIGHTING ON PLANS IS PLACED INTO THE INPUT DATA REPORT. | | | REVISED CALCULATIONS WERE SUBMITTED HOWEVER INFORMATION | | | ON SOME ITEMS HAS NOT YET BEEN CONFIRMED ON PLANS. | | | AN EXAMPLE OF THIS IS THE LOW VOLTAGE FIXTURE *W* WHICH | | | NOTES A LOW VOLTAGE REMOTE TRANSFORMER AS NEEDED. | | | HOWEVER PLEASE SEE 13-415.2.ABC.1.1,.1.2 AS THE VA | | | REQUIRED TO BE PART OF THE IDR IS TO BASED ON THE VA | | | RATING OF THAT REMOTE TRANSFORMER. IF THESE ARE NOT YET | | | LISTED THEN HOW CAN THE CALCULATIONS BE ACCURATE? | | | PLEASE BE SURE TO GO OVER *ALL* FIXTURES ON PLANS AND | | | BE SURE THESE ARE ALL IN THE IDR WITH THE LATEST | | | REVISIONS OF FIXTURES. THIS WOULD INCLUDE LIGHTING ON | | | FANS. THE FIXTURES WILL HAVE A RATING WHICH IS WHAT THE | | | IDR IS REQUIRED TO SHOW. | | | THE FIXTURE RATING IS THE LOAD USED NOT THE BULB | | | RATING. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-08 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-08 |
Time |
09:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-08-27 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-08-27 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2008-08-27 14:03:20 | | | | ** DENIED4TH REVIEW ** | | | | | | | | | | | | | | | 1) NOTE:ENERGY CALCULATIONS DO NOT COORDINATE WITH | | | THE PLANS. NOT ALL EXTERIOR LIGHTS ON THE IDR AND NOT | | | ALL INTERIOR LIGHTS ON THE IDR COORDINATE WITH PLANS. | | | LIGHTING ON MEZZANINE LEVEL IS MISSING MANY FIXTURES. | | | LIGHTS FOR *H* FIXTURES ARE MISSING SOME. | | | SPOKE TO ENGINEER OF RECORD AND MECHANICAL DESIGNER AND | | | WILL CORRECT CALCULATIONS. 13-415.2.ABC.1.1,.1.2,.1.3. | | | | | | 2) NOTE: PLEASE SEE THIRD SET IS MISSING THE SIGNATURE, | | | DATE AND SEAL FROM SHEET E-002. | | | | | | 3) NOTE: STILL NEED LETTERING OF UNDERSTANDING FROM | | | OWNER THAT PROJECT CO WILL BE PLACED ON HOLD UNTIL FEE | | | BALANCE OF 4X FEE IS PAID IN FULL AS REQUIRED BY FS | | | 553.80(2)(B). | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-06-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-12 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-12 |
Time |
12:31 |
Sent To |
PC |
|
| Notes |
| 2008-06-12 12:32:13 | ** DENIED 3RD REVIEW ** | | | | | | ** PLEASE SEE THERE ARE STILL ITEMS ON PREVIOUS REVIEWS | | | WHICH ARE STILL IN NEED OF ADDRESSING THEREFORE SOME | | | COMMENTS ARE REPEATED FROM INITIAL REVIEW AS WELL AS | | | THE SECOND REVIEW. | | | | | | ** PLEASE ALSO SEE THERE ARE NEW COMMENTS DUE TO SOME | | | ITEMS ONLY NOW SUBMITTED FOR FIRST REVIEW. | | | | | | 1) NOTE: PLEASE SEE AS NOTED ON PREVIOUS REVIEWS | | | COMPLIANCE WITH FLORIDA BUILDING CODE AND CHAPTER 13 | | | FOR ENERGY CODE COMPLIANCE. | | | PLEASE SEE ONCE AGAIN THE SUBMITTED ENERGY CALCULATIONS | | | ARE REQUIRED TO COORDINATE WITH PLANS. ALL SYSTEMS ON | | | PLANS SHALL BE PLACED INTO THE INPUT DATA REPORT. THIS | | | IS REQUIRED OF ALL LIGHTING ON PLANS AS WELL AS OTHER | | | SYSTEMS SUCH AS BUILDING COMPONENTS. THE FOLLOWING | | | ITEMS WILL ONCE AGAIN BE NOTED. THE INPUT DATA REPORT | | | WILL BE NOTED AS IDR. | | | PLEASE SEE 13-400.3.A, 13-415.1.A, 13-415.1.AB, | | | 13-415.2, 13-415.2.ABC.1.1, .1.2 AND .1.3. ALL LIGHTING | | | ON PLANS SHALL COORDINATE WITH THE IDR FOR WATTAGE OF | | | FIXTURES, THE TYPES OF FIXTURES, THE METHOD OF CONTROLS | | | AND THE NUMBER OF FIXTURES. ON THE PREVIOUS REVIEW | | | EXAMPLES WERE GIVEN AS A BENEFIT TO HELP LOCATE ALL | | | FIXTURES WHICH ARE CLEARLY SHOWN ON PLANS HOWEVER ARE | | | NOT BEING SHOWN IN THE CALCULATIONS. | | | ONCE AGAIN THIS REVIEWER WILL GIVE SOME EXAMPLES AND | | | CAN NOT EXPRESS ENOUGH THE FOLLOWING IS NOT AN | | | EXHAUSTED LIST NOR IS IT ALL ITEMS WHICH DO NOT | | | COORDINATE. | | | | | | FOR EXAMPLE: | | | PLEASE SEE EXTERIOR LIGHTING ON THE IDR WHICH DOES NOT | | | INCLUDE ANY 400W OR 35W FIXTURES.THESE ARE ONLY TWO | | | FIXTURES ON EXTERIOR WHICH ARE BEING NOTED. HOW IS THIS | | | POSSIBLE WHEN THE PLANS CLEARLY SHOW TYPE *S-1* AND *L* | | | ??HOW IS THIS POSSIBLE WHEN THE PLANS CLEARLY SHOW | | | DOZENS OF MORE FIXTURES THAN WHAT IS SHOWN IN THE INPUT | | | DATA REPORT? | | | THESE TWO FIXTURES ALONE WERE SPECIFICALLY GIVEN AS A | | | BENEFIT ON PREVIOUS REVIEW ALONG WITH OTHER YET THESE | | | ARE STILL NOT IN THE ENERGY CALCULATIONS. THERE ARE | | | OTHER FIXTURES ON PLANS WHICH ALSO DO NOT COORDINATE | | | WITH THE NUMBER OF FIXTURES AND THE WATTAGE. | | | | | | FOR EXAMPLE: | | | PLEASE SEE THE INTERIOR LIGHTING ON PLANS WHICH ARE ALL | | | REQUIRED TO COORDINATE WITH THE IDR OF THE SUBMITTED | | | ENERGY CALCULATIONS. PLEASE SEE ONE ZONE SUCH AS THE | | | *SURRENDER LOBBY* DOES NOT COORDINATE WITH ALL LIGHTING | | | ON PLANS. PLEASE SEE THE NUMBER OF FIXTURES AND WATTAGE | | | OF THESE FIXTURES IN THIS AREA IS GREATER THAN THE | | | NUMBER OF FIXTURES SHOWN ON THE IDR. | | | | | | FOR EXAMPLE: | | | PLEASE SEE ALL METHOD OF CONTROLS IS REQUIRED TO BE | | | AUTOMATIC PER CODE. HOW CAN MANUAL ON/OFF CONTROLS | | | STILL BE NOTED IN THE IDR? | | | | | | FOR EXAMPLE: | | | PLEASE SEE THE IDR SHOWS *HOSPITAL* AS THE ALLOWANCE | | | FOR LIGHTING HOWEVER BASED ON THE BUILDING CODE AND | | | DEFINITIONS IN NFPA-70 AS WELL AS NFPA-101 THIS CAN NOT | | | BE CLASSIFIED AS A HOSPITAL. PLEASE SEE THE COVER SHEET | | | FOR THE ENERGY CALCULATIONS DOES NOT SHOW HOSPITAL, IT | | | SHOW OFFICE. PLEASE ADJUST THE IDR FOR INTERIOR | | | LIGHTING ALLOWANCES IN THESE AREAS. | | | | | | ** AS NOTED ON PREVIOUS REVIEWS, PLEASE BE SURE ALL | | | ITEMS ON PLANS ARE PLACED INTO THE IDR/ENERGY | | | CALCULATIONS. | | | ** SAME AS PREVIOUS REVIEWS. | | | | | | 2) NOTE: PLEASE SEE SOME LIGHTING CONTROLS DO NOT YET | | | COMPLY WITH CHAPTER 13. PLEASE SEE MECHANICAL ROOM ON | | | FIRST FLOOR WHERE *SHIPS* LADDER IS LOCATED. THIS ROOM | | | SHOWS A TWIST TIME YET THIS ROOM ON SHEET E-104 ALSO | | | SHOWS A 3-WAY SWITCH AND OCCUPANCY SENSOR. PLEASE | | | EXPLAIN HOW THIS WILL OPERATE. PLEASE SEE THE FOLLOWING | | | COMMENT WITH RESPECT TO THE PROPOSED TIMERS. PREVIOUS | | | REVIEW ALSO REQUESTED THE MAXIMUM TIMES TO BE NOTED ON | | | PLANS. THE RESPONSE MENTIONS TO SEE NOTE ADDED TO | | | PLANS. PLEASE SEE THE NOTE WAS ADDED HOWEVER THE CODE | | | SECTION NOTED NEEDS TO BE ADJUSTED. IT SHOULD BE | | | 13-415.1.ABC.1.1.( PLEASE ADJUST FOR POSSIBLE | | | MISPRINT) | | | 13-415.1.ABC.1.1, .1.2. | | | **PREVIOUS COMMENT AND NEW BASED ON DESIGN CHANGES. | | | | | | 3) NOTE: PLEASE SEE FBC 11-4.27.4 AS TWIST TIMERS AS | | | NOTED ON SYMBOL LEGEND MAY NOT BE USED AS THEY DO NOT | | | MEET ADA MINIMUM REQUIREMENTS. | | | **NEW COMMENT. | | | | | | 4) NOTE: THE MANUFACTURES SPECS/CUT SHEETS ARE ONLY NOW | | | BEING SUBMITTED FOR THE FIRST TIME FOR REVIEW. RESPONSE | | | AND PLANS NOW SHOW THE OVER CURRENT PROTECTION FROM THE | | | GENERATOR BEING REMOVED. THIS IS OK HOWEVER WHEN DOING | | | SO THIS NOW REQUIRES THE CONDUCTORS FROM THE GENERATOR | | | TO THE FIRST MEANS OF OVER CURRENT PROTECTION TO MEET | | | 445.13. THIS SECTION OF THE CODE REQUIRES THE | | | CONDUCTORS TO BE SIZE AT A MINIMUM OF 115%. PLEASE BE | | | AWARE OF THE TEMPERATURE RISE ON SPECS AS THE OUTPUT | | | AMPERAGE IS GREATLY AFFECTED. EVEN IF THE OUTPUT IS THE | | | LOWER OF THE FOUR SHOWN THE CONDUCTORS AS LISTED ARE | | | STILL NOT LARGE ENOUGH. PLEASE KNOW AS THE TEMP RISE IS | | | TYPICALLY THE 150C, OR 130C AS SHOWN THE OUTPUT | | | AMPERAGE IS 1504 AMPS. THE CONDUCTORS PER 310.16, | | | 110.14 ARE RATED FOR 1550AMPS. THE 115% RATING FOR | | | MINIMUM SHALL BE 1729.6, OR RATHER 1730AMPS MINIMUM. | | | PLEASE SEE 240.4C, 310.16 AND 110.14. THE CONDUCTORS ON | | | DEVICES RATED OVER 800AMPS SHALL MEET OR EXCEED THIS | | | RATING. PLEASE ADJUST CONDUCTORS OR PLACE OVER CURRENT | | | PROTECTION BACK ON GENERATOR. | | | ** NEW COMMENT BASED ON CHANGES MADE TO DESIGN. | | | | | | 5) NOTE: THE PREVIOUS REVIEWS REQUESTED THE SPECS FOR | | | THE ATS. THESE WERE SUBMITTED AND THE GENERAL SHEET | | | INDICATES SWITCHES RATED UP TO 4000AMPS.HOWEVER THE | | | MANUFACTURES SPECS INSIDE THE PACKAGE DOES NOT INDICATE | | | ANY 1600AMP ATS UNITS AS SHOWN ON PLANS. THEY LIST | | | 1200AMP BUT NOT THE OTHER. PLEASE PROVIDE COORDINATING | | | MANUFACTURE SPECS. THIS MAY AFFECT AIC WITHSTAND | | | RATINGS ETC. | | | 90.7, 110.3. | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION AND | | | COORDINATION. | | | **PREVIOUS COMMENTS AND NEW COMMENT. | | | | | | 6) NOTE: PLEASE KNOW THE RESPONSE FOR SLAB ELEVATION | | | DOES NOT CLEARLY GIVE ANY INFORMATION ON FLOOD ZONE. | | | PLEASE KNOW THIS CAN BE A PROVISO AS THIS IS STRICTLY | | | AN OPTIONAL STAND-BY SYSTEM HOWEVER THE EQUIPMENT IS | | | STILL REQUIRED TO BE MOUNTED A MINIMUM OF 6INCHES ABOVE | | | THE FLOOD LEVEL. A CERTIFICATION BY A LICENSED | | | SURVEYOR, ENGINEER OR ARCHITECT WILL BE REQUIRED FOR | | | ELEVATION VERIFICATION AND CERTIFICATION OF THE SLAB | | | ONCE INSTALLED. | | | ** THIS WAS ON PREVIOUS REVIEW AND AS NOTED CAN BE DONE | | | AS A *PROVISO*. | | | | | | 7) NOTE: PLEASE SEE THE LIGHTING SHOWN THE UPPER AREA | | | OF THE FIRST FLOOR MECHANICAL ROOM ON SHEET E-104 IS | | | NOT THE SAME AS THE LIGHTING IN THE SAME ROOM AS SHOWN | | | ON E-103. | | | PLEASE COORDINATE. | | | FBC 106.1.2 | | | ** NEW COMMENT AS ROOMS ARE NOW LABELED. | | | | | | 8) NOTE: PLEASE KNOW AS THE EGRESS FROM THE SECOND | | | LEVEL MECHANICAL ROOM IS NOW CLEAR AS DISCUSSED WITH | | | OTHER REVIEWERS IT APPEARS THE EGRESS FROM MECHANICAL | | | ROOM #2 IS OUTSIDE AND ACROSS THE ROOF BACK INTO | | | MECHANICAL ROOM #1 AND THEN DOWN LADDER. PLEASE KNOW | | | EGRESS LIGHTING FOR NORMAL AND EMERGENCY CONDITIONS | | | SHALL BE PROVIDED AT THIS ROOF AREA BETWEEN THE DOORS | | | ON THE SECOND ROOM BACK INTO THE FIRST ROOM. NFPA-101 | | | 7.8, 7.9. | | | ** NEW COMMENT | | | | | | 9) NOTE: PLEASE PLACE NOTE ON PLANS FOR BONDING OF | | | METAL FRAMING PER 2704.1. THIS WAS CONFIRMED RECENTLY | | | ON A STATE LEVEL THIS NOTE SHOULD BE ON PLANS. | | | ** NEW COMMENT | | | | | | 10) NOTE: THE PREVIOUS REVIEW REQUESTED TO SHOW | | | COMPLIANCE FOR SOUND LEVELS OF FIRE ALARM HORN DEVICES | | | PER FBC 11-4.28.2. RESPONSE MENTIONS TO SEE NOTE ADDED | | | TO FA RISER. THE NOTE QUOTES THE SAME CODE SECTION AS | | | GIVEN IN REVIEW. THE CODE MAY NOT BE QUOTED IN GENERAL | | | IN LIEU OF GIVING SPECIFIC DETAILS. THE LEVEL(S) NEED | | | TO BE SHOWN OR NOTED AS REQUIRED IN THE SECTION OF THE | | | CODE. THE NOTE ALSO STATES LEVELS ARE REQUIRED DURING | | | TESTING. THE LEVELS OF HORN DEVICES DURING INITIAL | | | TESTING WOULD ACTUALLY BE LOUDER THAN LEVELS ACTUALLY | | | HEARD DURING BUILDING OCCUPANCY. THE CODE REQUIRES THE | | | LEVELS TO BE ABOVE THE OTHER MAXIMUM SOUND LEVELS IN | | | ANY ONE AREA ETC. PLEASE SEE THE FOLLOWING TEXT IS | | | EXTRACTED FROM THE CODE FOR CLARITY OF COMMENTS SO THE | | | NOTES, DEVICES AND SOUND LEVELS OF DEVICES CAN BE | | | ADJUSTED, SHOWN OR NOTED. | | | **IF PROVIDED, AUDIBLE EMERGENCY ALARMS SHALL PRODUCE A | | | SOUND THAT EXCEEDS THE PREVAILING EQUIVALENT SOUND | | | LEVEL IN THE ROOM OR SPACE BY AT LEAST 15 DBA OR | | | EXCEEDS ANY MAXIMUM SOUND LEVEL WITH A DURATION OF 60 | | | SECONDS BY 5 DBA, WHICHEVER IS LOUDER. SOUND LEVELS FOR | | | ALARM SIGNALS SHALL NOT EXCEED 120 DBA.** | | | | | | 11) NOTE: THE PREVIOUS REVIEW GAVE SEVERAL NOTES WITH | | | RESPECT TO CIRCUITING AND EVEN GAVE SOME EXAMPLES. | | | PLEASE SEE 210.52B1 AS THE MINIMUM OF TWO SMALL | | | APPLIANCE CIRCUITS ARE REQUIRED ON PLANS. THESE SHALL | | | NOT CONTAIN ANY OTHER ITEMS ON THESE CIRCUITS WITH THE | | | EXCEPTION OF THE ITEMS LISTED IN THE 210.52B1. LIGHTING | | | IS NOT PERMITTED TO BE ON THE SMALL APPLIANCE | | | CIRCUITS. | | | PLEASE SEE SHEET E-102 AS THE LIGHTING CIRCUITS SHOWN | | | ARE CIRCUITS P4-1, P4-3 AND P4-5. PLEASE SEE THE PANEL | | | SCHEDULE ON SHEET WHICH SHOWS ONLY TWO OF THESE | | | LIGHTING CIRCUITS. CIRCUIT SHOWN AS P4-5 IS ACTUALLY | | | *BLANK* ON SCHEDULE AS THIS IS NOTED AS *SPARE*. PLEASE | | | ALSO SEE SHEET E-202 AS THIS CLEARLY SHOWS THE LIGHTING | | | STILL BEING CIRCUITED TO THE SMALL APPLIANCE CIRCUITS | | | AS THE SMALL APPLIANCE CIRCUITS ON THIS SHEET E-202 IS | | | SHOWING P4-1 AND P4-3 AS THE SMALL APPLIANCE CIRCUITS. | | | PLEASE SEE THE FOLLOWING TEXT WHICH IS EXTRACTED FROM | | | THE CODE WHICH INDICATES WHICH ITEMS MAY ON THE SAME | | | CIRCUITS AS THE SMALL APPLIANCE CIRCUITS. | | | **(B) SMALL APPLIANCES | | | (1) RECEPTACLE OUTLETS SERVED IN THE KITCHEN, PANTRY, | | | BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREA OF A | | | DWELLING UNIT, THE TWO OR MORE 20-AMPERE | | | SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY | | | 210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE | | | OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP OUTLETS | | | COVERED BY 210.52(C), AND RECEPTACLE OUTLETS FOR | | | REFRIGERATION EQUIPMENT.** | | | THIS CAN BE FOR RECEPTACLE OUTLETS ONLY IN THESE AREAS, | | | NO OTHER OUTLETS ARE PERMITTED. PLEASE ADJUST. | | | ** PREVIOUS REVIEWS. | | | | | | 12) NOTE: THE PREVIOUS REVIEW GAVE SEVERAL NOTES WITH | | | RESPECT TO CIRCUITING AND EVEN GAVE SOME EXAMPLES. | | | PLEASE SEE THE PREVIOUS REVIEWS WITH RESPECT TO | | | REQUIRED ARC FAULT PROTECTION REQUIRED ON ALL OUTLETS | | | IN BEDROOMS PER 210.12. THE PREVIOUS PANEL SCHEDULE | | | ALONG WITH THE CURRENT REVISED PANEL SCHEDULE SUBMITTED | | | CONTAINS TWO ASTERISK ( **) AT THE TOP OF THE PANEL | | | SCHEDULE WHICH STATES THE CIRCUITS NOTED WITH THE TWO | | | ASTERISK (**) ARE TO CONTAIN AFCI BREAKERS/ARC FAULT | | | PROTECTION. PLEASE SEE THE PREVIOUS REVIEW GAVE | | | SPECIFIC NOTE THAT NOT ALL CIRCUITS WHICH REQUIRED AFCI | | | PROTECTION SHOWED THE ASTERISK (**). THE RESPONSE | | | MENTIONS THE TWO CIRCUITS WHICH REQUIRE ARC FAULT | | | PROTECTION PER THE 2005 NEC DOES SHOW THE PROTECTION. | | | ** PLEASE SEE THE 2002 AS WELL AS THE 2005 NEC REQUIRES | | | ARC FAULT PROTECTION FOR *ALL OUTLETS* INSIDE THE | | | SLEEPING ROOMS. THIS PROTECTION IS NOT FOR RECEPTACLES | | | ONLY. THIS IS FOR RECEPTACLES, LIGHTS, SMOKE ALARMS | | | (WHEN 120V) , FANS ETC. | | | PLEASE SEE THE PLANS STILL DO NOT SHOW ANY PROTECTION | | | FOR THE OTHER OUTLETS IN THESE ROOMS. THE CIRCUITS | | | WHICH INDICATE PROTECTION STILL ONLY SHOW THIS FOR | | | *RECEPTACLES*. PLEASE SEE CIRCUITS NOTED AS P4-1 AND | | | P4-5 DO NOT INDICATE PROTECTION. | | | PLEASE SEE E-102 AND E-303. AS NOTED ABOVE IN NOTE #11 | | | CIRCUITS ALSO DO NOT CORRELATE. | | | PLEASE COORDINATE PLANS, PLEASE ADJUST FOR CODE | | | COMPLIANCE AND PLEASE LIST ALL REQUIRED BRANCH CIRCUITS | | | WITH AFCI PROTECTION AS REQUIRED PER 2005 NEC. | | | ** PREVIOUS REVIEWS | | | | | | 13) NOTE: DINING ROOM WALL APPEARS TO REQUIRE A SECOND | | | RECEPTACLE TO MEET WALL SPACING REQUIREMENTS PER | | | 210.52. WALL SPACE IS UNCLEAR AND IS BEING NOTED AS THE | | | INDENTION IN WALL MAY OR MAY NOT BE CABINETS. AS THIS | | | IS DOES NOT SHOW CABINETS AND APPEARS TO BE WALL, | | | PLEASE ADD RECEPTACLE AS TOTAL LENGTH OF WALL FROM | | | DOORWAY OF LAUNDRY ROOM TO DOORWAY AT FRONT DOOR | | | APPEARS TO BE 12FT OR MORE. | | | ** NEW COMMENT. | | | | | | 14) NOTE: PLEASE SUBMIT THE MANUFACTURE SPECS/CUT SHEET | | | SHOWING THE 42CIRCUIT PANELS AS 100AMP RATED. AS NOTED | | | PREVIOUSLY PANELS AT 100AMP RATED AND 60AMP RATED ARE | | | NOT KNOWN TO BE 42CIRCUIT. PLEASE SUBMIT SPEC/CUT | | | SHEET. A SEARCH OF A FEW OF THE STANDARD MANUFACTURE | | | DID NOT PRODUCE ANY LISTED 42CIRCUIT PANEL BOARDS WHICH | | | WERE ONLY 100AMP RATED. | | | NEC 110.3, 90.7 | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 15) NOTE: PLEASE PLACE NOTE ON PLANS FOR COLOR CODING | | | OF CONDUCTORS. THE SPECIFICATION DIVISION SPECS ARE NOT | | | PART OF THE RECORD PLANS AND ARE NOT TYPICALLY USED | | | DURING INSPECTIONS. THESE ARE NOT PART OF REVIEW FOR | | | MINIMUM CODE COMPLIANCE. PLEASE PLACE NOTE ON | | | RISER/ALONG WITH CONDUCTORS FOR BROWN, PURPLED AND | | | YELLOW. 277/480V. | | | 90.4, 310.11,310.12 ETC | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION AND | | | COORDINATION. | | | ** PREVIOUS COMMENTS. | | | | | | 16) NOTE: PLEASE SEE PREVIOUS REVIEW NOTES WHICH | | | MENTIONED THE RECEPTACLE WHICH APPEARED TO BE SHOWN | | | ABOVE THE CEILING FOR WATER COOLERS. THE SECTION OF | | | CODE GIVEN WAS THAT NO CORDS ARE PERMITTED ABOVE THE | | | CEILING. THE RESPONSE COMMENT MENTIONED THESE | | | RECEPTACLES ARE FOR REMOTE CHILLER UNIT ABOVE CEILINGS. | | | THESE ARE NOT PERMITTED TO BE CORD AND PLUG CONNECTED. | | | PLEASE SEE 400.8 AND PLEASE REVISE DESIGN. | | | FBC 106.1.2. | | | | | | 17) NOTE: PLEASE SEE PREVIOUS REVIEW GAVE NOTICE TO | | | FLORIDA STATUTES 553.80(2)(B) WITH RESPECT TO REPEAT | | | COMMENTS FOR CODE COMPLIANCE. THERE ARE SEVERAL CODE | | | SECTIONS WHICH HAVE BEEN REPEATED FOR THE THREE | | | REVIEWS. THE FEE IS A STATUTORY REQUIRED FEE AND IS NOT | | | A LOCAL ORDINANCE, FINE OR REQUIRED BY THE LOCAL LEVEL. | | | THE FEE IS ASSESSED TO THE DESIGN TEAM AS REQUIRED BY | | | THE STATUTE. THE FEE IS THE PORTION OF THE BASE FEE | | | ATTRIBUTED TO PLAN REVIEW TIMES FOUR. THE BASE PERMIT | | | FEE OF THIS PROJECT IS $52,000. THE PORTION OF THAT FEE | | | WHICH IS ATTRIBUTED TO PLAN REVIEW IS 30% OF THE BASE | | | PERMIT FEE WHICH IS $15,600. THIS IS THE AMOUNT TIMES | | | FOUR WHICH IS ASSESSED. THIS AMOUNT IS $62,400. THIS IS | | | A STATUTE REQUIRED FEE WHICH IS REQUIRED TO BE PAID | | | BEFORE PLANS ARE RESUBMITTED FOR THE FOLLOWING REVIEW. | | | PLEASE KNOW THAT ONE SET OF ELECTRICAL PLANS ALONG WITH | | | ENERGY CALCULATIONS AND OTHER POSSIBLE DOCUMENTS ARE | | | BEING RETAINED BY THIS OFFICE. | | | IT IS RECOMMENDED IF THERE ARE QUESTIONS TO PLEASE | | | CONTACT THIS OFFICE/REVIEWER. | | | | | | *** PLEASE KNOW THERE MAY VERY WELL BE NEW COMMENTS ON | | | THE NEXT REVIEW WHICH CAN NOT BE MADE AT THIS TIME DUE | | | TO INFORMATION ETC NOT YET IN DESIGN OR ON PLANS. | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-02-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-02-07 |
Time |
20:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-02-06 |
Time |
19:31 |
Sent To |
|
|
| Notes |
| 2008-02-07 20:07:48 | 2008-02-07 20:07:48 | | | | | | *** DENIED 2ND REVIEW*** | | | | | | | | | NEW GRACE PAVILION | | | PEGGY ADAMS ANIMAL RESCUE LEAGUE. | | | | | | *** PLEASE SEE THERE ARE ITEMS FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING. PLEASE ALSO SEE | | | THERE ARE ALSO NEW NOTES DUE TO CHANGES, NEW ITEMS OR | | | NOTES BASED ON NEW DOCUMENTS NOT PREVIOUSLY SUBMITTED, | | | ** AS MENTIONED ON PREVIOUS REVIEW ALL ITEMS COULD NOT | | | BE REVIEWED AND THERE MAY BE NEW COMMENTS WHICH COULD | | | NOT HAVE BEEN MADE. | | | | | | 1) NOTE: PLEASE SEE PREVIOUS REVIEW NOTES WHICH | | | MENTIONED TO SEE CODE REFLECTED ON PLANS NEED TO BE | | | CHANGED TO THE CURRENT CODE IN WHICH THE PROJECT WAS | | | UNDER FOR DESIGN. A COUPLE OF EXAMPLES WERE GIVEN AND | | | STILL NEED TO ADDRESS THESE. | | | PLEASE SEE WITH THE EXCEPTION OF THE CORRECTION FOR | | | CODES REFLECTED ON THE BOTTOM OF PANEL P1-S2, ALL OTHER | | | PANELS STILL SHOW CODE FROM THE 1999 NFPA-70. PLEASE | | | SEE THIS SAME CODE 220.13 IS STILL ALSO BEING REFLECTED | | | ON THE PANEL P4 EVEN AS THIS DOES NOT APPLY TO THIS | | | RESIDENTIAL UNIT. PLEASE ADJUST. | | | PLEASE SHEET E-301 OCTAGONAL NOTE #6 WHICH REFLECTS | | | 250.81C WHICH IS FROM THE 1996 NFPA-70. PLEASE BE SURE | | | TO GO OVER PLANS AND ADJUST ANY CODE REFERENCED. FBC | | | 106.1.2 FOR COORDINATION. | | | | | | 2) NOTE: PLEASE CLARIFY WHY THE RESPONSE NOTES CONTAIN | | | A BOOKLET FOR CAPRI ENGINEERING IN THE MIDDLE OF NOTES | | | SHOWING PROJECTS ETC. IF THIS PROJECT IS BEING | | | SUBMITTED AS PRIVATE PROVIDER PLEASE FOLLOW | | | REQUIREMENTS OF FS 553.791. AS THIS PROJECT HAS NOT | | | BEEN SUBMITTED PREVIOUSLY UNDER FS 553.791 WITH ALL | | | DOCUMENTS REQUIRED IT IS UNCLEAR WHY OTHER DOCUMENTS | | | WERE SUBMITTED. | | | PLEASE ALSO VERIFY CURRENT DOCUMENTS FROM CAPRI | | | ENGINEERING AS THESE MAY BE UPDATED. | | | | | | 3) NOTE: PLEASE BE SURE TO MAKE SURE ADDRESSING ON ALL | | | DOCUMENTS SUBMITTED IS REFLECTED TO THE NEW ADDRESS | | | ASSIGNED BY THE ADDRESSING REVIEWER. | | | PLEASE SEE FOR EXAMPLE: PLANS SHOW 3100, PERMIT | | | APPLICATION SHOWS 3200 AND ENERGY CALCULATIONS SHOW | | | 3200. | | | FBC ADMIN SECTION 106.1.2, 106.5 | | | FAC 61G1-16.004, 61G15-23.002 | | | | | | 4) NOTE: PLEASE SEE NOTES FROM OTHER TRADES FOR ANY | | | REFERENCES TO THE GENERATOR, LOCATION, SCREENING ETC. | | | PLEASE SUBMIT CALCULATIONS FOR BUILDING REVIEW OF SLAB | | | DETAIL. PLEASE KNOW IF IN A FLOOD ZONE, THE UNIT SHALL | | | BE REQUIRED TO BE A MINIMUM OF 6INCHES ABOVE GRADE. | | | PLEASE SEE THE PLANS SHOW A SLAB THICKNESS OF ONLY | | | 4INCHES FOR THIS 1000KW GENERATOR. PLEASE KNOW THE | | | INSTALLATION SHALL MEET NFPA-110CHAPTER 7 AND MINIMUM | | | INSTALLATION REQUIREMENTS AS SET-FORTH BY THE GENERATOR | | | MANUFACTURE. | | | PLEASE BE SURE TO SEE ANY POSSIBLE COMMENTS FROM OTHER | | | REVIEWERS WITH RESPECT TO THE GENERATOR ON THE OTHER | | | TRADE PLANS SUCH AS ARCHITECTURAL SITE PLANS, LANDSCAPE | | | ETC. THIS IS GIVEN FOR INFORMATION ONLY BY THIS | | | REVIEWER AS THIS INFORMATION WAS FORWARDED TO OTHER | | | TRADES TO PLACE IN COMMENTS AS APPLICABLE. | | | PLEASE SUBMIT THE MANUFACTURE SPECS/CUT SHEETS ON THIS | | | UNIT AND FUEL TANK. THE FUEL TANK WILL BE REVIEWED BY | | | MECHANICAL AND FIRE REVIEW AND PLEASE SEE NOTES FROM | | | THOSE TRADES WITH RESPECT TO DERM STAMPS REQUIRED BASED | | | ON THE SIZE OF FUEL CAPACITY. | | | FBC 106.1.2 | | | NEC 110.3, 90.7 | | | | | | 5) NOTE: PLEASE SEE THE RISER SHOWS GFP (GROUND FAULT | | | PROTECTION) ON THE GENERATOR UNIT ITSELF. IS THIS NOT | | | TO READ GFS, (GROUND FAULT SENSING) OR GFA (GROUND | | | FAULT ALARM) ? THE CODE REQUIRES THE GFP PROTECTION ON | | | THE NORMAL SIDE OF THE SERVICE EQUIPMENT, BUT NOT ON | | | THE EMERGENCY SIDE. THE CODE DOES REFERENCE GROUND | | | FAULT SENSING. | | | PLEASE SUBMIT THE MANUFACTURES SPECS/CUT SHEETS FOR | | | THIS UNIT AS NOTED ABOVE AND FOR THE ATS DEVICE. 110.3, | | | 90.7 | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | THE RISER STATES TO SEE SPECS FOR THE ATS YET COULD NOT | | | LOCATE ANY SUBMITTED IN PACKAGE. | | | | | | 6) NOTE: PLEASE SEE THE RISER HAS THIS GENERATOR AS A | | | SEPARATELY DERIVED UNIT WHICH IS CODE COMPLIANT AND | | | CORRECT HOWEVER PLEASE SEE THE RISER DOES NOT SHOW ANY | | | GROUNDING ELECTRODE SYSTEM FOR THIS UNIT. PLEASE SEE | | | 250.20, 250.30, 250.50. | | | PLEASE SEE NFPA-110 6.2.1.5 | | | | | | 7) NOTE: PLEASE SEE THE RAISED SEAL FROM THE ENGINEER | | | ON THE SEVERAL SHEETS AND SUPPORTING DOCUMENTS ARE ONCE | | | AGAIN FAINT ON MANY SHEETS WHERE THE LICENSE | | | INFORMATION CAN NOT BE SEEN. THIS WAS A COMMENT ON | | | PREVIOUS REVIEW AND RESPONSE WAS THIS WILL BE | | | ADDRESSED. MOST SHEETS ARE OK, HOWEVER SOME ARE STILL | | | NOT READABLE. PLEASE SEE ENERGY CALCULATIONS FOR | | | EXAMPLE AS ONE OF THE SETS COULD NOT BE READ. PLEASE | | | SEE FAC 61G15-23.001 WHICH REQUIRES ALL INFORMATION TO | | | BE CLEAR AND VISIBLE. | | | | | | 8) NOTE: PLEASE SUBMIT COMPLETE ENERGY CALCULATIONS FOR | | | REVIEW AND BE SURE TO COORDINATE ALL INFORMATION ON THE | | | INPUT DATA REPORT WITH THE LIGHTING ON PLANS AND THE | | | FIXTURE LEGEND. 13-415.1.A, 13-415.1.AB, 13-415.2 THE | | | INPUT DATA REPORT IN THE REST OF THIS COMMENT WILL BE | | | REFLECTED AS IDR. | | | | | | A) ** PLEASE BE SURE TO GO THROUGH ALL ITEMS ON THE | | | INTERIOR LIGHTING SHOWN ON THE IDR AND COORDINATE WITH | | | PLANS. PLEASE SEE THERE ARE DIFFERENCES IN THE AMOUNT | | | OF FIXTURES, THE WATTAGES/TOTALS AND THE METHOD OF | | | CONTROLS. | | | PLEASE SEE FOR EXAMPLE: LOBBY AREA LIGHTING ON PLANS | | | DOES NOT MATCH WITH THE AMOUNT AND TYPE OF FIXTURES ON | | | THE IDR. | | | PLEASE SEE FOR EXAMPLE: THE METHODS OF CONTROL FOR SOME | | | ARE BEING SHOWN AS *MANUAL ON/OFF* YET THE METHOD OF | | | CONTROL IS AN AUTOMATED MEANS. PLEASE GO OVER ALL | | | FIXTURES ON PLANS AND COORDINATE WITH THE IDR. THIS | | | OFFICE CAN NOT EMPHASIZE ENOUGH THE IMPORTANCE. THE | | | ENERGY CALCULATIONS SUBMITTED DATED JUNE 07 AND DEC 07 | | | ARE NOT CHANGED. | | | | | | B) ** PLEASE BE SURE TO GO OVER PLANS AND THE SQUARE | | | FOOTAGE INFORMATION ON THE CALCULATIONS SUBMITTED. | | | PLEASE SEE THE PERMIT APPLICATION STATES A SQ FT LESS | | | THAN CALCULATIONS AND THE CALCULATIONS COVER SHEET IS | | | LESS THAN THATOF THE SQ FT SHOWN ON THE ARCHITECTURAL | | | PLANS. | | | 13-415.1.A, 13-400.3.A | | | | | | C) ** PLEASE BE SURE ALL INFORMATION ON PLANS FOR | | | EXTERIOR LIGHTING COORDINATES WITH THE IDR AND THE | | | FIXTURE LEGEND. PLEASE SEE FOR AN EXAMPLE: THE IDR FOR | | | EXTERIOR LIGHTING SHOWS A TOTAL OF 24 -40WATT FIXTURES. | | | HOW IS THIS POSSIBLE WHEN NOT ONLY THE PLANS SHOWS | | | DOZENS MORE FIXTURES FOR EXTERIOR LIGHTING FIXTURES BUT | | | THE FIXTURE WATTAGES ON PLANS ARE SUBSTANTIALLY HIGHER | | | THAN THE STATED 40WATTS ON THE IDR. | | | PLEASE SEE SOME OF THESE FOR EXAMPLE ARE 400W FIXTURES, | | | 70W, 50W ETC ETC. PLEASE SEE THE FIXTURE LEGEND FOR | | | TYPES, P, D1, S-1, L, H ETC . THIS IS NOTED ONLY FOR A | | | FEW. | | | | | | D) ** PLEASE SEE THE CLASSIFICATION OF THE EXTERIOR | | | LIGHTING FIXTURES ON THE IDR MENTIONS * LIGHTING THAT | | | IS SPECIFICALLY DESIGNATED AS REQUIRED BY A HEALTH OR | | | LIFE SAFETY, STATUE, ORDINANCE, OR REGULATION*. PLEASE | | | PROVIDE INFORMATION ON ANY OF THESE AS THERE ARE KNOWN | | | STATUTES, ORDINANCES, LIFE SAFETY CODES ETC WHICH | | | REQUIRES ANY OF THESE EXTERIOR LIGHT FIXTURES. PLEASE | | | ADJUST DESIGNATIONS. | | | | | | E) ** PLEASE BE SURE THE ENERGY CALCULATIONS ARE | | | SIGNED, DATED AND SEALED WITH RAISED SEAL AS NOTED | | | ABOVE AND REQUIRED PER FAC 61G15-23.002, FS 471.025 AND | | | FBC 13-103.1.1.1. | | | PLEASE BE SURE THE OWNER AGENT IS ALSO SIGNED ON NEW | | | CALCULATIONS. | | | | | | 9) NOTE: PLEASE SUBMIT AND SHOW ALL MAXIMUM TIMES FOR | | | ALL LIGHTING CONTROL DEVICES PER 13-415.1.ABC.1.1, .1.2 | | | AND .1.3 | | | | | | 10) NOTE: PLEASE BE SURE TO SHOW AND LABEL ALL ROOM AND | | | AREA DESIGNATIONS ON PLANS. PLEASE SEE FOR EXAMPLE | | | ROOMS OFF OF LOADING DOCKS/BAY AREAS WHICH DOE NOT | | | CONTAIN ANY DESIGNATIONS. | | | PLEASE SEE FOR EXAMPLE: THE ROOM NORTH OF STORAGE AND | | | WEST OF MECHANICAL ROOM. PLEASE KNOW AS THESE ROOMS ARE | | | NOT DESIGNATE * STORAGE 101* ETC THE CIRCUITING CAN NOT | | | BE VERIFIED. | | | FBC 106.3.5.1.2, 106.1.2 FOR COORDINATION AND | | | ADDITIONAL INFORMATION. | | | NEC 408.4 ETC | | | | | | 11) NOTE: PLEASE CORRELATE ALL CIRCUITING ON PLANS WITH | | | THAT OF THE PANEL SCHEDULES SUBMITTED OR TO BE | | | SUBMITTED. | | | PLEASE SEE SOME EXAMPLES BELOW: | | | | | | A) ** THE WP GFI CIRCUITED FOR THE ROOF-TOP UNITS | | | INDICATE A P-78, YET NO *P* PANEL IS ON RISER OR | | | SUBMITTED WITH SCHEDULES. THIS IS ASSUMED AS MISPRINT. | | | | | | B) **PLEASE SEE PANEL P4 WHICH CONTAINS MANY CIRCUITS | | | WHICH DO NOT CORRELATE. PLANS SHOW LAUNDRY ROOM | | | RECEPTACLE ON CIRCUIT 4, YET THE PANEL SCHEDULE SHOWS | | | 6. | | | | | | C) ** PLEASE SEE PLANS SHOWS WASHER ON CIRCUIT P-14, | | | YET THE PANEL SCHEDULE SHOWS P-12. THIS AFFECTS THE | | | DRYER AND OTHER CIRCUITS. | | | | | | D) ** PLEASE SEE P4-16 AS THIS IS BEDROOM ON PLANS AND | | | BATH ROOM ON SCHEDULE. | | | | | | ** THESE ARE SOME EXAMPLES OF THE PLANS FOR ALL. PLEASE | | | SEE THERE ARE OTHERS ALSO AND SOME ARE NOTED BELOW WITH | | | RESPECT TO OTHER CODES AFFECTED BY MANY NOT CIRCUITED | | | CORRECTLY. | | | 408.4, 240.4, 310.16, ETC | | | FBC 106.3.5.4, 106.3.5.1.2, 106.1.2 FOR COORDINATION. | | | | | | 12) NOTE: PLEASE SEE NFPA-70 210.11C3 WHICH REQUIRES | | | DEDICATE BATH CIRCUIT(S) IN ONLY TWO SCENARIOS. PLEASE | | | KNOW WHEN THE GFI IS FED IN ONE BATH ROOM AND FEEDS | | | OTHER ITEMS IN THAT *SAME* BATH, IT MAY NOT FEED ANY | | | OTHER ROOMS, BATHROOMS OR APPLIANCES. | | | PLEASE SEE FOR EXAMPLE: THE CIRCUIT SHOWN ON PLANS FOR | | | P4-18 SHOWS THE GFI BEING FED AND THEN THE PANEL | | | SCHEDULE ALSO NOTES THIS AS FEEDING NOT ONLY THE | | | EXHAUST FAN IN THE SAME BATHROOM WHICH IS OK, BUT THE | | | PANEL SCHEDULE ALSO SHOWS THIS FEEDING EF-82 AND83 | | | WHICH IS NOT PERMITTED PER CODE SECTION NOTED ABOVE. | | | PLEASE ALSO SEE FOR EXAMPLE: THE PANEL SCHEDULE SHOWS | | | THE P4-6 AS FEEDING BATH AND LAUNDRY ROOM COMMON | | | RECEPTACLE WHICH IS NOT PERMITTED. THE PLANS ACTUALLY | | | SHOW THE LAUNDRY ROOM RECEPTACLE ON WITH THE BEDROOM. | | | | | | 13) NOTE: PLEASE SEE THE PANEL SCHEDULE SHOWS PANEL P4 | | | WITH THREE SMALL APPLIANCE CIRCUITS YET THE LOAD | | | CALCULATIONS ONLY INDICATE TWO. | | | PLEASE ALSO SEE THE PLANS ARE MISSING THE THIRD CIRCUIT | | | ALSO: (15). | | | PLEASE SEE 210.52B1, 210.11C1, 220.52 | | | | | | 14) NOTE: PLEASE SEE COUNTER SPACE IN BETWEEN RANGE AND | | | WALL TOWARDS ELECTRICAL PANEL APPEARS TO BE MISSING A | | | GFI RECEPTACLE PER 210.52C1 FOR 12 INCHES OR MORE OF | | | COUNTER SPACE BASED ON SCALE ON PLANS. | | | | | | 15) NOTE: PLEASE SEE ARC FAULT PROTECTION IS NOT SHOWN | | | FOR ALL OUTLETS IN THE BEDROOMS AS REQUIRED PER 210.12 | | | OF THE 2005 NEC> | | | PLEASE KNOW THIS REQUIRES ALL RECEPTACLES, FANS, LIGHTS | | | ETC | | | PLEASE SEE FOR EXAMPLE: CIRCUIT # 16 DOES NOT INDICATE | | | ANY DOUBLE ** ASTERISK AS NOTED ON PANEL FOR AFCI | | | BREAKER. | | | PLEASE ADJUST. | | | | | | 16) NOTE: PLEASE VERIFY SOUNDING LEVELS FOR ADA | | | COMPLIANCE ON PLANS PER FBC 11-4.28.2. | | | | | | 17) NOTE: PLEASE CLARIFY THE NOTE AND LOCATIONS OF | | | LIGHTING ON SHEET E-104. THE TITLE ON THIS SHEET | | | MENTIONS MECHANICAL SPACE STILL YET THE RESPONSE TO ONE | | | OF THE PREVIOUS COMMENTS IS THAT MECHANICAL EQUIPMENT | | | IS ON ROOF. | | | PLEASE SEE THE RESPONSE TO NOTE #15 STILL MENTIONS A | | | MEZZANINE LEVEL HOWEVER LIGHTING CONTROLS PER FBC | | | 13-415.1.ABC.1.1 AND .1.2 ARE NOT LOCATED ON THIS | | | SHEET. | | | THERE IS A NOTE ON LIGHTING PLANS E-103 WHICH MENTIONS | | | TO INDIRECT LIGHTING ABOVE. ARE THE FIXTURES ON E-104 | | | OPEN AND ABOVE FIRST FLOOR AREA? | | | ARE THESE SEPARATE AREAS? SEE NOTES FORM OTHER TRADES. | | | NO FINAL DETERMINATION CAN BE DONE AT THIS TIME. | | | | | | 18) NOTE: PLEASE SEE THE COLOR CODING FOR THE 277/480V | | | SYSTEM CONDUCTORS WILL BE REQUIRED TO BE BROWN, PURPLE, | | | AND YELLOW. | | | PLEASE KNOW FOR SEVERAL DECADES ALL OF PALM BEACH | | | COUNTY ALONG WITH THE CITY OF WEST PALM BEACH CONTAINED | | | TECHNICAL AMENDMENTS TO THE CODE FOR COLOR CODING OF | | | CONDUCTORS AS NFPA-70 DOES NOT PROVIDE COLOR CODING OF | | | SYSTEM VOLTAGES. AS THE TECHNICAL AMENDMENTS ARE NO | | | LONGER IN EFFECT AND KEEPING WITH THE CONSISTENCY OF | | | SAFE INSTALLATION PRACTICES WITHIN THE CITY THIS IS | | | REQUIRED ON A LOCAL LEVEL. THE COLOR ORANGE AS STATED | | | IN DIVISION SPECS IS CLEARLY REQUIRED FOR *HIGH-LEG* | | | DELTA SYSTEMS IN THE NEC AND WOULD NOT APPLY FOR | | | 277/480V SYSTEMS. | | | PLEASE ADJUST COLOR CODING AS NOTED ABOVE. PLEASE ALSO | | | SEE PAGE #4 IN 16120 3.01. | | | 90.4 | | | | | | 19) NOTE: PLEASE CLARIFY EMERGENCY BACK UP LIGHTING. | | | THE RESPONSE MENTIONS THAT HALF SHADED FIXTURES WILL BE | | | BATTERY BACK UP AND DETAILS ON LIGHTING PLANS SHOW THAT | | | BATTERIES ARE PART OF THE FIXTURE WIRING HOWEVER THE | | | FIXTURE SCHEDULE DOES NOT CONTAIN ANY NOTES FOR BACK UP | | | BALLAST/BATTERIES. PLEASE ALSO SEE THE SHADED FIXTURES | | | ON THE ELECTRICAL SYMBOL LEGEND ONLY SHOWS FIXTURES | | | *B*. | | | PLEASE ADJUST AND COMPLETE FIXTURE LEGENDS FOR ALL NEW | | | FIXTURES AS NOTED. | | | LS -101 7.8, 7.9 | | | | | | 20) NOTE: **ONLY NOTED** ANY PROPOSED INSTALLED | | | LIGHTNING PROTECTION SYSTEM WILL BE UNDER SEPARATE | | | PLANS, PERMIT AND MOST IMPORTANTLY SHALL MEET | | | NFPA-780. | | | | | | 21) NOTE: PLEASE CLARIFY J-BOX BEING SHOWN ABOVE | | | CEILINGS FOR WATER COOLERS. | | | PLEASE KNOW NO CORDS ARE PERMITTED ABOVE CEILINGS FOR | | | CORD AND PLUG CONNECTED UNITS. | | | PLEASE KNOW THIS CAN BE REDLINED BUT WILL STILL NEED TO | | | SHOW FINAL CONNECTIONS PER NEC. | | | THIS CAN BE DONE AT THIS TIME OR WILL BE NEED TO BE | | | REVISED AT A LATER DATE. | | | 400.8 | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 22) NOTE: PLEASE KNOW THE REQUIRED CALCULATIONS FOR | | | SITE LIGHTING POLES MAY BE PART OF A *PROVISO* WHICH | | | WILL REQUIRE THESE TO BE SUBMITTED BEFORE INSTALLATION. | | | THIS IS GIVEN FOR INFORMATION AT THIS TIME. IF WIND | | | LOAD CALCULATIONS ARE PROVIDED AT THIS TIME, THERE WILL | | | BE NO NEED FOR PROVISO. | | | | | | 23) NOTE: PLEASE SEE THERE IS A LOSS IN TRANSLATION FOR | | | THE CLARIFICATION OF THE PANEL RATINGS. THE PREVIOUS | | | REVIEW NOTES MENTIONED THERE WERE SEVERAL PANELS SHOWN | | | AS 60AMP RATED MAIN LUG ONLY PANELS AND 30 CIRCUITS. | | | THE COMMENT MENTIONED THAT THIS OFFICE WAS NOT AWARE OF | | | 30CIRCUIT 60AMP RATED MLO PANELS AND TO VERIFY. THE | | | PLANS HAVE NOW COME BACK WITH 42CIRCUIT 60AMP RATED MLO | | | PANELS. | | | IF THE PANEL IS FED FROM A 60AMP BREAKER THIS WOULD NOT | | | BE A 60AMP RATED MLO PANEL. IT WOULD STILL BE RATED AT | | | THE AMPERAGE RATING OF THE PANEL. IE; 150A RATED, 200 | | | AMP RATED, 225AMP RATED MLO. | | | PLEASE SUBMIT THE MANUFACTURES SPECS/CUT SHEETS FOR ANY | | | 60AMP RATED 42 CIRCUIT PANELS. | | | 110.3, 90.7. | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION | | | | | | 24) NOTE: PLEASE CLARIFY THE AIC RATINGS OF ALL THE | | | PANELS AND EQUIPMENT. PLEASE SEE FOR EXAMPLE THE SAME | | | PANELS AS NOTED ABOVE IN NOTE #23 ARE BEING SHOWN WITH | | | A 22,000 RATING. IS THIS FOR THE PANEL? THE BRANCH | | | BREAKERS? OR BOTH? | | | PLEASE SEE THE MSB IS SHOWN AS 42,000 AIC RATED ON | | | SCHEDULE YET THE NOTES ON RISER ON SHEET E-301 MORE | | | SPECIFICALLY MSB NOTES 2A INDICATES 100,000 AIC RATED | | | MAIN. WHICH ONE IS THIS? | | | PLEASE INDICATE THE RATINGS OF PANELS AND BRANCH | | | BREAKERS AND ANY MAIN BREAKERS. | | | IF THE AIC RATING IS SHOWN AS 22K, THEN THIS IS WHAT | | | WILL BE REQUIRED TO BE INSTALLED. | | | 110.9, 110.3, 90.7 | | | FBC 106.1.2 FOR ADDITIONAL INFORMATION. | | | | | | 25) NOTE: PLEASE SEE THE CEILING FANS IN THE | | | RESIDENTIAL UNIT WILL REQUIRE LIGHT KITS OR OTHER MEANS | | | OF TURNING ON LIGHTING IN ROOMS PER 210.70 SHALL BE | | | SUPPLIED. THIS CAN BE DONE WITH SWITCHED RECEPTACLE OR | | | OTHER LIGHTING MEANS. THE FIXTURE LEGEND FOR FANS | | | INDICATES NO LIGHTING TO BE A PART OF THE FANS. IN FACT | | | IT IS BLANK. | | | LS 101 7.8 | | | | | | 26) NOTE: PLEASE KNOW AS MENTIONED ON PREVIOUS REVIEW | | | AND IN MEETING HELD AFTER THE FIRST REVIEW, IF THE | | | DISCONNECTING MEANS ON THE GENERATOR DOES NOT MEET THE | | | *EXCEPTIONS* IN THE CODE MORE SPECIFICALLY 702.11. A | | | DISCONNECT RATED FOR THE LOAD SERVED SHALL BE REQUIRED | | | AT THE BUILDING PER 225.31-225.39. THIS DISCONNECT AS | | | PREVIOUSLY MENTIONED DOES NOT REQUIRE OVER CURRENT | | | PROTECTION. THIS ONLY REQUIRES DISCONNECT TO BE RATED | | | FOR THE LOAD SERVED. THE SHUNT/BUTTON SHOWN ON RISER | | | DOES NOT MEET CODE FOR THIS REQUIREMENT. | | | | | | 27)NOTE: PLEASE SEE NOTICE TO FLORIDA STATUTES | | | 553.80(2)(B) IS BEING GIVEN WITH RESPECT TO REPEAT | | | COMMENTS FOR CODE COMPLIANCE. THIS IS ONLY GIVEN AS A | | | NOTICE AT THIS TIME. | | | PLEASE KNOW THAT ONE SET OF ELECTRICAL PLANS MAY BE | | | RETAINED BY THIS OFFICE ALONG WITH ONE SET OF THE | | | ENERGY CALCULATIONS. | | | | | | 28) NOTE: PLEASE CONFIRM THE LOCATION OF THE FACP WHICH | | | IS NOW IN THE TELECOM ROOM. | | | PLEASE BE SURE TO CONTACT THE FIRE MARSHAL AS THIS WILL | | | HAVE AN AFFECT ON THE ELECTRICAL PLANS AND ANY | | | RELOCATION NEEDED. | | | | | | ** AS THERE ARE ITEMS NOT YET SUBMITTED, OR ITEMS FROM | | | OTHER TRADES WHICH MAY AFFECT PROJECT DESIGN, PLEASE | | | KNOW THAT ANY CHANGES ETC WHICH ARE NOT PART OF THIS | | | SUBMITTED PACKAGE COULD NOT BE REVIEWED AT THIS TIME. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2008-02-06 19:31:37 | 2008-02-06 19:31:37 | | | | | | ONE SET OF PLANS AND SPECS IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-03 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-02 |
Time |
18:36 |
Sent To |
I |
|
| Notes |
| 2007-07-03 11:51:13 | 2007-07-03 11:51:13 | | | | | | *** UNSAT *** | | | | | | | | | NEW GRACE PAVILION | | | PEGGY ADAMS ANIMAL RESCUE LEAGUE. | | | | | | ** PLEASE KNOW AS THERE ARE MANY ITEMS NOT YET | | | SUBMITTED FOR REVIEW, WHEN PLANS AND DOCUMENTS ARE | | | SUBMITTED FOR REVIEW ON THE NEXT RE-SUB THEY WILL BE | | | THE FIRST TIME IN FOR REVIEW. THERE MAY BE NEW COMMENTS | | | ONCE ADDITIONAL INFORMATION IS SUBMITTED. | | | | | | | | | 1) NOTE: PLEASE SEE THE SUBMITTED DOCUMENTS REQUIRE THE | | | CODES TO BE STATED ON PLANS. PLEASE SEE THE FOLLOWING | | | ARE REQUIRED FOR ELECTRICAL AND OTHERS WILL BE REQUIRED | | | FOR OTHER TRADES. PLEASE KNOW AS OF DECEMBER 8TH, 2006 | | | THE STATE ADOPTED THE 2006 REVISIONS TO THE 2004 FBC. | | | PLEASE SEE SOME OF THE CORRECT CODES ARE REFLECTED ON | | | PLANS BUT NOT ALL. PLEASE SEE SOME PREVIOUS CODES NO | | | LONGER IN EFFECT ARE STATED. PLEASE SEE SOME CODE | | | SECTIONS WHICH ARE STATED ON PLANS ARE NOT FROM THE | | | CURRENT NEC. | | | PLEASE LIST THE FOLLOWING: | | | 2004 FBC W/ 2006 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | 2002 NFPA-110 | | | | | | 2) NOTE: PLEASE SEE MISSING INFORMATION ON TITLE BLOCKS | | | FOR THE CIVIL ENGINEERING FIRM PER FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 AND FLORIDA STATUTES | | | 471.023. | | | PLEASE SEE THE MISSING CERTIFICATE OF AUTHORIZATION | | | NUMBER. | | | ** THIS IS REQUIRED FOR ALL *C* SHEETS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 3) NOTE: PLEASE SEE MISSING TITLE BLOCK INFORMATION FOR | | | LANDSCAPE ARCHITECTURAL FIRM AS REQUIRED PER FAC | | | 61G1-16.004 AND FS 481.219. | | | PLEASE SEE MISSING CERTIFICATE OF AUTHORIZATION NUMBER | | | ALSO KNOWN AS THE FIRM LICENSE NUMBER. | | | ** PLEASE SEE THIS IS REQUIRED FOR ALL SHEETS WHETHER | | | OR NOT COMMENT IS MADE BY OTHER TRADES. | | | | | | 4) NOTE: PLEASE SEE THE ELECTRICAL SHEETS ARE MISSING | | | TITLE BLOCKS FOR THE MEP FIRM AS SHOWN ON OTHER | | | SHEETS. | | | | | | PLEASE COMPLETE THESE SHEETS WITH THE INFORMATION AS | | | REQUIRED PER FAC 61G15-23.002. | | | | | | 5) NOTE: PLEASE SEE THE RAISED SEAL FROM THE ENGINEER | | | ON THE ELECTRICAL AND FP SHEETS ARE EXTREMELY FAINT. | | | THE INFORMATION ON SAID SEALS ARE NOT VISIBLE OR EASILY | | | READ. PLEASE SEE FAC 61G15-23.001 WHICH REQUIRES ALL | | | INFORMATION TO BE CLEAR AND VISIBLE. | | | ** PLEASE SEE THIS IS REQUIRED OF ALL TRADES AND FOR | | | ALL SHEETS, ALTHOUGH IT IS MAINLY ON THE E AND FP | | | SHEETS. | | | | | | 6) NOTE: PLEASE SUBMIT COMPLETE ENERGY CALCULATIONS FOR | | | REVIEW. PLEASE SEE FBC CHAPTER 13, 13-415.1.AB.1.1, | | | 13-415.1.C, AND PERFORMANCE CALCULATIONS PER 13-415.2. | | | AS NO INFORMATION WAS SUBMITTED, NO REVIEW OF THESE | | | COULD BE DONE. | | | PLEASE BE SURE TO SEE 13-103.1.1.1 FOR SIGNED, DATED | | | AND SEALED SHEETS. | | | ** PLEASE CHECK WITH FLA-COM FOR LATEST VERSION AS | | | EFFECTIVE DATE OF DECEMBER 8TH, 2006 WHEN THE LATEST | | | CODE CHANGE WENT INTO EFFECT. | | | | | | 7) NOTE: PLEASE INDICATE THE WORST CASE SCENARIOS FOR | | | VOLTAGE DROP OF CIRCUITS FOR FEEDERS AND BRANCH | | | CIRCUIT(S). 13-413.1.ABC.1 | | | | | | 8) NOTE: PLEASE SEE THERE ARE AREAS WHICH DO NOT SHOW | | | ANY AUTOMATED DEVICES FOR LIGHTING CONTROLS OR SHUT | | | OFFS. PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3 OF THE | | | 2004 FBC W/2006 REVISIONS. | | | PLEASE BE SURE ALL MAXIMUM TIMES ON DEVICES ARE NOTED | | | AND SHOWN. | | | PLEASE SEE AS THERE ARE AREAS WHICH DO NOT SHOW CONTROL | | | AT THIS TIME INCLUDING UPPER LEVELS, SOME ITEMS CAN NOT | | | BE REVIEWED AT THIS TIME. | | | | | | 9) NOTE: PLEASE KNOW ALL LOW VOLTAGE SYSTEMS WILL BE | | | REQUIRED TO BE UNDER SEPARATE PERMITS. THESE SUBMITTED | | | PLANS MAY BE USED TO REFERENCE HOWEVER SEPARATE PERMIT | | | APPLICATIONS, AND FEES WILL BE DUE FOR THAT SCOPE OF | | | WORK SUCH AS LV CATV< PHONE, DATA, ETC. IF THESE ARE | | | ALL DONE BY THE SAME CONTRACTOR, ALL CAN BE ON ONE | | | PERMIT. | | | PLEASE KNOW THAT LOW VOLTAGE PERMITS FOR FIRE ALARM | | | SYSTEMS ARE SEPARATE AND REQUIRE PLANS ALONG WITH | | | PERMIT APPLICATION. | | | ** NO CHANGES NEED TO BE MADE TO PLANS; THIS IS BEING | | | NOTED FOR INFORMATIONAL PURPOSE ONLY. | | | | | | 10) NOTE: PLEASE SEE THE MAIN ELECTRICAL ROOM SHOWS THE | | | MDF WHICH IS PART OF THE IT EQUIPMENT. PLEASE SEE THIS | | | ROOM IS A HIGH VOLTAGE ELECTRICAL ROOM AND ACCESS TO | | | THIS ROOM SHOULD BE LIMITED TO *QUALIFIED PERSONNEL* AS | | | STATED IN THE NEC. PLEASE SEE THAT MANY TIME THIS | | | EQUIPMENT ON THE MDF REQUIRES ACCESS TO OTHER THAN | | | *QUALIFIED PERSONNEL*. PLEASE SEE THAT CONSIDERATION TO | | | THE LOCATION OF THIS EQUIPMENT SHOULD BE TAKEN AND | | | RELOCATED OR SEPARATE FROM THE MAIN ELECTRICAL ROOM AND | | | EQUIPMENT. | | | 110.26, 110.27, 110.16, 110.18 | | | | | | 11) NOTE: PLEASE SUBMIT WIND LOAD CALCULATIONS FOR THE | | | SITE LIGHTING POLES. PLEASE KNOW THESE ARE ALREADY | | | STATED ON SITE PLANS MEETING THE FBC FOR WIND | | | REQUIREMENTS HOWEVER THE CALCULATIONS ARE STILL NEEDED | | | FOR REVIEW. THESE ARE REQUIRED TO CONTAIN THE TITLE | | | BLOCKS FROM THE DESIGN PROFESSIONAL AND TO BE SIGNED, | | | DATED AND SEALED. | | | FBC 106.1.2 | | | | | | 12) NOTE: PLEASE CLARIFY LIGHTING FIXTURES ON PLANS. | | | THE FIXTURE SCHEDULE DOES NOT INDICATE ANY BATTERY BACK | | | UP LIGHT FIXTURES EVEN THOUGH MANY OF THE FIXTURES ARE | | | HALF SHADED WHICH TYPICALLY STANDS FOR BATTERY BACK UP | | | LIGHT FIXTURES. | | | PLEASE ADJUST AND INDICATE BATTERY BACK UP FIXTURES ARE | | | THE MINIMUM AMOUNT OF BATTERY BACK UP FIXTURES WILL BE | | | REQUIRED TO MEET THE MINIMUM FOOT CANDLES IN EGRESS | | | PATHS TO THE PUBLIC RIGHT OF WAY OUTSIDE OF THE | | | BUILDING. PLEASE SEE NFPA-101 7.8 AND 7.9. | | | PLEASE ALSO SEE THE MAIN ELECTRICAL ROOM WILL ALSO BE | | | REQUIRED TO CONTAIN AN BATTERY BACK UP LIGHT OF SOME | | | KIND. | | | PLEASE SEE 700.12F FOR CIRCUITING AND 700.16. | | | | | | 13) NOTE: PLEASE BE SURE TO STATE ALL ROOM AND AREA | | | DESIGNATIONS ON PLANS AND BE SURE THESE CORRELATE WITH | | | THE PANEL SCHEDULES AS SUBMITTED ON PLANS. MOST ARE | | | DONE HOWEVER SOME ARE MISSING. | | | FBC 106.1.2, 106.3.5.1.2 | | | NEC 408.4 | | | | | | 14) NOTE: PLEASE CLARIFY UPPER LEVEL PLANS FOR LIGHTING | | | AND POWER. PLEASE SEE THERE ARE ELECTRICAL AND | | | MECHANICAL ON PLANS HOWEVER NO CIRCUITING, NO ROOM | | | DESIGNATIONS, ETC. PLEASE SEE THE SHADED AREAS ON THE | | | LOWER RIGHT HAND CORNER OF PLANS ON E104 AND 204 WHICH | | | INDICATES THE AREA OF THE BUILDING IN WHICH THESE AREAS | | | ARE LOCATED HOWEVER THE SHADED ARE ENCOMPASSES THE | | | ENTIRE BUILDING AS SHOWN. AS THESE AREAS ARE CLEAR OF | | | USE, HOW AREA IS ACCESSED, CIRCUITING, LIGHTING | | | CONTROLS ETC REVIEW FOR MANY ITEMS CAN NOT BE DONE AT | | | THIS TIME. | | | PLEASE SE FBC ADMIN SECTION 106.1.2 AND 106.3.5.1.2 FOR | | | ADDITIONAL INFORMATION NEEDED. | | | PLEASE SEE NEC 408.4, AND THE FOLLOWING WHICH IS TAKEN | | | FROM THE NEC COMMENTARY. | | | | | | 15) NOTE: PLEASE CLARIFY ANY ROOF-TOP GFI RECEPTACLES | | | REQUIRED FOR A/C EQUIPMENT. PLEASE SEE 210.63, 210.8B3. | | | AT THIS TIME THE LOCATION OF ALL EQUIPMENT IS NOT | | | CERTAIN. | | | | | | 16) NOTE: PLEASE SEE THE APARTMENT/RESIDENTIAL UNIT AS | | | SHOWN ON PLANS WILL BE REQUIRED TO MEET THE NEC FOR A | | | DWELLING UNIT. | | | PLEASE SEE MISSING THE TWO MINIMUM REQUIRED SMALL | | | APPLIANCE CIRCUITS. 210.52B1, 210.11C1, 220.52 PLEASE | | | SEE THE DINGING ROOM RECEPTACLES ARE SHOWN CIRCUITED TO | | | THE LIVING ROOM WHICH IS NOT PERMITTED. SAME CODE | | | SECTION. | | | PLEASE SEE THE MINIMUM VA FOR THESE REQUIRED CIRCUITS. | | | PLEASE SEE THE MINIMUM REQUIRED FOR WASHER IS NOT | | | CORRECT.210.11C2, 220.52 | | | PLEASE SEE THE MINIMUM FOR THE DRYER IS NOT CORRECT. | | | 220.54 | | | PLEASE SEE MISSING ARC FAULT PROTECTION PER 210.12 TO | | | BE LISTED ON PANEL SCHEDULE. | | | PLEASE SEE MISSING THE REQUIRED DEDICATED BATH | | | CIRCUIT(S) PER 210.11C3.(THESE ARE SHOWN SHARING WITH | | | OTHER DEVICES IN OTHER ROOMS AS LISTED ON PANEL | | | SCHEDULE. | | | PLEASE SEE MISSING GFI RECEPTACLE/PROTECTION REQUIRED | | | FOR WASHING MACHINE. THIS IS NOW WITHIN 6FT OF A | | | LAUNDRY TUB. IT DOES NOT MATTER IF THIS DEDICATED | | | DEVICE/OUTLET UNDER THE NEW CODE. 210.8A7 | | | PLEASE VERIFY THE LOAD SHOWN FOR THE RANGE AS IT | | | APPEARS LOW. | | | PLEASE SUBMIT LOAD CALCULATIONS FOR A DWELLING FOR THIS | | | PANEL. | | | PLEASE SEE THE CODE SECTION AS REFLECTED TO 220.13 IS | | | NOT UNDER THE 2005 NEC AND WOULD NOT APPLY. | | | PLEASE SEE NEC 220, FBC 106.3.5.4 | | | | | | 17) NOTE: PLEASE SUBMIT ALL MANUFACTURES SPECS/CUT | | | SHEETS FOR THE GENERATOR, ATS, SUB-BASE FUEL TANK ETC | | | FOR REVIEW. | | | PLEASE SEE THE MECHANICAL REVIEW AS THE PLANS WILL BE | | | REQUIRED TO BE REVIEWED AND STAMPED BY DERM DUE TO THE | | | SIZE OF THE TANK. | | | ** PLEASE SEE THE SITE, SURVEY, CIVIL, LANDSCAPE AND | | | OTHER PLANS DO NOT INDICATE ANY GENERATOR UNIT. THIS | | | NOTE WILL BE FORWARDED TO OTHER TRADES AS THERE WILL BE | | | COMMENTS FROM OTHER TRADES SUCH AS ELEVATION, LOCATION, | | | SETBACKS, ETC. | | | 110.3, 90.7 | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 18) NOTE: PLEASE SEE THE SERVICE IS BEING SHOWN AS GFI | | | PROTECTED ALONG WITH GFI PROTECTION ON THE GENERATOR? | | | PLEASE SEE THE REQUIRED PROTECTION PER 230.95, 240.13 | | | ETC IS FOR *GFP* PROTECTION WHICH IS NOT THE SAME AS | | | CLASS A GFI PROTECTION FOR PERSONNEL. | | | PLEASE ADJUST THE DESIGNATION. | | | PLEASE ALSO SEE THE FOLLOWING AS GFP ON THE EMERGENCY | | | SECONDARY SIDE IS NOT REQUIRED AND IN FACT ON ANY | | | SYSTEMS WHICH ARE CONSIDERED LEGALLY REQUIRED OR | | | EMERGENCY SYSTEMS ARE NOT RECOMMENDED BY THE CODE TO | | | CONTAIN SUCH PROTECTION. PLEASE KNOW BASED ON THE | | | INTEREST OFLIFE SAFETY THIS AHJ WILL NOT PERMIT THIS | | | AS IT CREATES THIS HAZARD TO OCCUPANTS. | | | PLEASE ALSO SEE THE ATS IS BEING SHOWN AS 3-POLE AND | | | NOT 4-POLE WHEN A 4-POLE SWITCH WOULD BE NEED WHEN | | | THERE IS GFP PROTECTION ON THE MAIN. | | | PLEASE SEE NFPA-110 6.2.15** ISOLATION OF NEUTRAL | | | CONDUCTORS. PROVISIONS SHALL BE INCLUDED FOR ENSURING | | | CONTINUITY, TRANSFER, AND ISOLATION OF THE PRIMARY AND | | | THE EPS NEUTRAL CONDUCTORS WHEREVER THEY ARE SEPARATELY | | | GROUNDED TO ACHIEVE GROUND-FAULT SENSING. | | | PLEASE SEE AN ATTACHED BRIEF EXPLANATION FROM "ASCO" | | | WHITE PAPER: THERE ARE NUMEROUS OTHER NOTED DOCUMENTS | | | FROM MULTIPLE MANFACTURES WHICH STATE ROUGHLY THE | | | SAME: | | | * WHERE GROUND FAULT PROTECTION IS TRIGGERED BY THE | | | CODE AND AN ALTERNATE POWER SUPPLY IS INCLUDED, | | | SWITCHING OF THE NEUTRAL BECOMES NECESSARY. THE CIRCUIT | | | SHOWN ABOVE ILLUSTRATES SUCH A CIRCUMSTANCE. THE | | | SERVICE IS LARGER THAN 1,000 AMPS. CONSEQUENTLY, GROUND | | | FAULT PROTECTION IS REQUIRED AT THE MAIN SERVICE | | | DISCONNECT AT A MINIMUM. IF IT IS INSTALLED THERE AND | | | THE GENERATOR NEUTRAL GROUNDING WAS THROUGH A SOLID | | | CONNECTION TO THE MAIN SERVICE NEUTRAL, A GROUND FAULT | | | WHEN THE GENERATOR IS FEEDING THE LOAD WILL CAUSE THE | | | MAIN SERVICE DISCONNECT TO OPEN. THIS WILL NOT | | | DISCONNECT THE ARCING FAULT FROM THE GENERATOR. | | | COORDINATION IS THUS LOST.* | | | PLEASE KNOW BASED ON THE INFORMATION FROM SEVERAL | | | MANUFACTURES AND THE CODE PLEASE ADJUST AS REQUIRED. | | | PLEASE ALSO SEE GENERATOR GROUNDING DETAIL WILL BE | | | REQUIRED TO BE REVISED. | | | PLEASE SEE 250.20, 250.30, 250.66, 240.13, 230.95, | | | 700.7D, 700.26 | | | | | | 19) NOTE: PLEASE INDICATE ALL TRANSFORMER GROUNDING | | | ATTACHMENTS ON THE RISER AND SIZES OF CONDUCTORS. | | | 250.20, 250.50, 250.66, 250.58 | | | | | | 20) NOTE: PLEASE PROVIDE AN ENLARGED VIEW OF THE MAIN | | | ELECTRICAL ROOM WITH EXACT SCALE FOR REVIEW OF | | | ELECTRICAL EQUIPMENT. | | | 110.26 | | | FBC 106.1.2 | | | | | | 21) NOTE: PLEASE CORRELATE PLANS AND RISER FOR THE | | | SIZES OF THE TRANSFORMER. PLEASE SEE RISER SHOWS 30KVA | | | AND THE PLAN SHOWS 45 KVA. | | | PLEASE SEE THIS MAY BE THE REASON FOR THE FOLLOWING | | | COMMENT IS THE TRANSFORMER IS INDEED A 45KVA UNIT. FBC | | | 106.1.2 COORDINATION. | | | | | | 22) NOTE: PLEASE SEE THE OVER CURRENT PROTECTION SHOWN | | | FOR THE BREAKER TO THE 30KW TRANSFORMER ON RISER IS TOO | | | HIGH AS LISTED IN THE MSB PANEL SCHEDULE AND RISER. | | | PLEASE SEE 450.3 AND THE MAXIMUM OF 125%.(UNLESS | | | MEETING EXCEPTION, IF SO, PLEASE PROVIDE ALL | | | INFORMATION FOR THE TRANSFORMER. | | | | | | 33) NOTE: PLEASE SEE THERE ARE SEVERAL PANELS ON RISER | | | AND PANEL SCHEDULES WHICH INDICATE 60AMP MLO AND PANEL | | | BEING ACTUALLY A HIGHER RATED PANEL. PLEASE KNOW IF | | | PANEL HAS A 60AMP/100AMP FEED ETC AND THE PANEL IS A | | | 100AMP/150AMP OR 200AMP RATED PANEL PLEASE INDICATE THE | | | ACTUAL PANEL RATING. THERE IS NO 60AMP RATED PANELS | | | WHICH ARE 30CIRCUIT KNOWN TO THIS OFFICE. | | | PLEASE SEE SEVERAL COMMENTS BELOW FOR COORDINATION OF | | | PANELS, RISER, AMPERAGES, AND WHETHER OR NOT PANELS | | | CONTAIN MLO OR MCB. | | | FBC 106.1.2 FOR COORDINATION. | | | | | | 34) NOTE: PLEASE SEE H3 WHICH IS SHOWN AS 60AMP MLO ON | | | RISER AND SHOWN AS 400AMP MCB ON PANEL SCHEDULE. PLEASE | | | CORRELATE. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 35) NOTE: PLEASE SEE PANEL P4 WHICH IS SHOWN A S 60AMP | | | MLO, YET CONTAINS 30CIRCUITS. | | | PLEASE CORRELATE. | | | FBC 106.1.2 | | | | | | 36) NOTE: PLEASE SEE PANEL C3 WHICH IS SHOWN AS 60AMP | | | MCB ON PANEL SCHEDULE AND 60AMP MLO ON RISER. PLEASE | | | CORRELATE. | | | FBC 106.1.2 | | | | | | 37) NOTE: PLEASE SEE PANEL C1 WHICH IS SHOWN AS 100AMP | | | MCB ON RISER AND 60AMP MCB ON PANEL SCHEDULE. PLEASE | | | CORRELATE. | | | FBC 106.1.2 | | | | | | 38) NOTE: PLEASE SEE C2 AS THIS IS SHOWN AS 60AMP MCB | | | AND MLO ON RISER. | | | PLEASE CORRELATE. | | | FBC 106.1.2 | | | | | | 39) NOTE: PLEASE SEE RISER INDICATES BOTH PANEL C2 AND | | | C3 BEING FED FROM PANEL C1, HOWEVER PANEL C1 SCHEDULE | | | DOES NOT INDICATE EITHER OF THESE TWO PANELS? PLEASE | | | CORRELATE AND ADJUST LOAD CALCULATIONS ETC. THIS WILL | | | AFFECT SEVERAL ITEMS. | | | FBC 106.1.2, 106.3.5.1.2 | | | NEC 240.4, 310.16, 408.4, 215.5 ETC. | | | | | | 40) NOTE: PLEASE SEE PANEL H2 IS SHOWN AS 150AMP MLO ON | | | RISER AND 200AMP MLO ON SCHEDULE. | | | PLEASE ADJUST AND CORRELATE. | | | FBC 106.1.2 | | | | | | 41) NOTE: PLEASE SEE CODE SECTION NOTED BELOW ALL PANEL | | | SCHEDULES WHICH INDICATES NEC 220.13? PLEASE SEE ANY | | | SECTIONS OF THE NEC TO BE NOTED MUST BE FROM THE 2005 | | | NEC> | | | PLEASE ADJUST. FBC 106.1.2 | | | | | | 42) NOTE: PLEASE SEE LOAD CALCULATIONS WILL NEED | | | ADJUSTMENTS ONCE OTHER CALCULATIONS HAVE BEEN | | | CORRECTED. | | | PLEASE SEE THE CONTINUOUS LOADS WHICH ARE NOTED ON MANY | | | OF THE PANEL SCHEDULES ARE NOT SHOWN FIGURED INTO THE | | | MAIN SERVICE AND THE MSB DOES NOTE OR SHOW ANY | | | CONTINUOUS LOADS AT 125%. | | | 215.3, 230.42, 220 ETC. | | | | | | 43) NOTE: PLEASE KNOW PLANS WILL BE ROUTED TO | | | ADDRESSING AS THIS IS A NEW BUILDING WHICH IS NOT THE | | | SAME AS THE EXISTING BUILDING ON THE SAME SITE. BOTH | | | BUILDINGS CAN NOT HAVE THE SAME ADDRESS. | | | PLEASE ADJUST TITLE BLOCKS AS NEEDED ONCE THE ADDRESS | | | HAS BEEN DETERMINED. | | | FAC 61G1-16.004, 61G15-23.002. | | | | | | ** PLEASE SEE ONE SET OF PLANS CONTAINS MANY AREAS | | | NOTED AND REDLINED IN AREAS OF NOTES. | | | | | | *** PLEASE KNOW AS THERE ARE SEVERAL DESIGN CHANGES | | | REQUIRED AND THERE ARE NUMEROUS ITEMS ON PLANS WHICH | | | ARE NOT COMPLETE THERE MAY VERY WELL BE NEW COMMENTSON | | | THE FOLLOWING REVIEW. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS.PLEASE KNOW ONLY | | | ONE SET OF THE OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | 2007-07-03 07:01:40 | 2007-02-03 07:01:40 | | | REVIEW CONTINUED. | | 2007-07-02 20:03:30 | 2007-07-02 20:03:30 | | | REVIEW STOPPED, REVIEW TO CONTINUE AND NOTES TO FOLLOW. | | 2007-07-02 18:38:37 | 2007-07-02 18:38:37 | | | PLANS REMOVED FROM INCOMING AND ONE ROLL IN ELEC FOR | | | REVIEW. PLANS WILL BE RETURNED BACK TO INCOMING WAITING | | | FOR COMM BOARD ONCE REVIEW HAS BEEN COMPLETED. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
6 |
Status |
N |
Date |
2009-10-23 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2009-10-23 |
Time |
07:52 |
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2009-10-23 |
Time |
07:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
N |
Date |
2009-06-16 |
|
|
Cont ID |
|
| Sent By |
dlauderm |
Date |
2009-06-16 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
dlauderm |
Date |
2009-06-16 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
N |
Date |
2009-01-14 |
|
|
Cont ID |
|
| Sent By |
efabian |
Date |
2009-01-14 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
efabian |
Date |
2009-01-14 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
N |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-08-28 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-08-28 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2008-01-09 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2008-01-03 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2008-01-09 11:21:08 | ENG PASSED. | | | ENG DRAWINGS & PACKAGE WILL BE STAMPED & SIGNED LATER | | | ALONG WITH ALL OTHER TRADES. | | | DEWEY P. JUST MENTIONED THAT DRAWINGS WILL BE REVISED | | | FOR OTHER TRADES & HE IS GOING TO CALL FOR PICK UP. | | | CIVIL DESIGN IS REQUESTED TO RESUBMIT THE ENG DWGS & | | | ALL OTHER SUPPORTING PACKAGE WITH LATEST REVISION FOR | | | FINAL STAMPS FOR ENG APPROVAL. 3 COPIES REQUESTED. | | | | | | RASIK CHOKSHI805-6723 | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-08-16 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-08-16 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2007-08-16 14:33:30 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON DRAWINGSTHE LOCATION OF DUMPSTER & | | | ITS ENCLOSURE PER CITY OF WPB, LOCATION MUST BE | | | ACCESSIBLE FOR PICKUP TRUCK. | | | 3. PLEASE SHOW IN YOUR CALCULATION HOW DID YOU | | | DETERMINR FIRST FLOOR ELEVATION, PARKING LOT ELEVATION | | | USING CENTER LINE OF ROAD , SIDEWALK ELEVATION, FLOOD | | | ZONE AREA OF THIS SITE, & 5,10, 25, 100 YEAR FLOOD | | | CRITERIATO DETERMINE THE FIRST FLOOR ELEVATION. | | | PLEASE PROVIDE CALCULATIONS. | | | 4. PLEASESHOW ON DRAWING THE TOTAL SITE AREA, | | | PERVIOUS AREA, IMPERVIOUS AREA, LAKE AREA, GREEN AREA, | | | PARKING/SIDEWALK AREA, BUILDING AREA ETC.ALSO PROVIDE | | | WATER QUALITY CALCULATIONS FOR THIS SITE | | | 4. MAKE SURE THESE SITE AREAS SHOWN ON DRAWINGS MUST | | | MATCH WITH AREAS USED IN STORM WATER QUALITY | | | CALCULATIONS. | | | 5. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM | | | WATER PIPES.PLEASE SHOW DETAIL OF THE CONTROL | | | STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, FROM YOUR CALCULATIONS.DO | | | YOU HAVE EXFILTRATION TRENCHES? . PLEASE SHOW DRY | | | DETENTION/WET DETENTION AREAS IN YOUR CALS. | | | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST AROUND | | | YOUR SITE EVENTHOUGH THEY ARE NOT IN YOUR SITE. | | | 7. PLEASE PROVIDE A COPY OF SFWMD OR NPBID PERMIT,, A | | | COPY OF GEO-TECH REPORT AND A LATESTEST COPY OF STORM | | | STORM WATER QUALITY CALCULATIONS THAT YOU PROVIDED AT | | | 45TH STREET. | | | 8. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | | SILT FENCE AROUND THE WHOLE SITE & CATCH BASINS NOT | | | PARTIALLY OPEN.HEIGHT OF FENCE SHOULD BE HIGH ENOUGH | | | PER FDEP TO STOP DUST & PARTICLES. | | | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2009-11-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-11-10 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-11-10 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2009-11-10 11:12:35 | | | | *****REVISION APPROVED***** | | | | | | | | | OF THE SUBMITTED REVISED SHEETS, A-100, A-400, FP-102, | | | AND FP-103 WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2009-07-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-07-06 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-07-06 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2009-07-06 11:10:41 | *****REVISION, DATED/PRINTED APR.'09, APPROVED***** | | | | | | | | | OF THE SUBMITTED REVISED SHEETS, A-100, A-400, AND | | | A-900 WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-01-20 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-01-20 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2009-01-20 15:05:51 | *****REVISIONS APPROVED***** | | | | | | | | | REVISED PLAN SHEETS LS-001 & LS-002, A-122, A-400, | | | FP-001 THRU FP-201, E101 THRU E104, AND E201 THRU E204 | | | WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-09-03 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-03 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2008-06-05 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-05 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-05 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2008-06-05 10:55:06 | ***DENIED*** | | | | | | IT APPEARS THAT THE PLANS ARE CODE COMPLIANT. PLEASE | | | SEE THE FOLLOWING COMMENTS: | | | | | | 6) OK | | | | | | 7) CITY OF WEST PALM BEACH PROPERTY SHALL HAVE A CITY | | | APPROVED KNOX BOX INSTALLED FOR EMERGENCY RESPONSES AS | | | CLARRIFICATION. | | | | | | 16) THIS WRITER HAS HAD NO COMMUNICATION REGARDING FLOW | | | DATA INFORMATION. IF THIS PROJECT IS IN THE CITY LIMITS | | | OF WEST PALM BEACH, A FLOW TEST SHALL BE CONDUCTED BY | | | WEST PALM BEACH FIRE RESCUE PRIOR TO PERFORMING FIRE | | | SPRINKLER WORK UNDER A SEPARATE PERMIT. | | | | | | 17) ADD COMMENT TO SEPARATE SHOP DRAWINGS WHEN APPLYING | | | FOR FIRE SPRINKLER PERMIT. | | | | | | PLANS CAN BE STAMPED WHEN RETURNED WITH CORRECTIONS FOR | | | OTHER REVIEW COMMENTS IF FIRE COMMENTS #7 AND #16 HAVE | | | BEEN SATISFIED. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-27 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-27 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2008-02-27 17:56:44 | *****DENIED***** | | | | | | THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 06.FIRE ALARM SYSTEM SHALL BE UL CERTIFIED FOR | | | CENTRAL STATION SERVICE.ADD COMMENT TO THE FIRE ALARM | | | NOTES | | | | | | 07.A KNOX-BOX WILL BE REQUIRED FOR THE BUILDING. SHOW | | | THE LOCATION OF THE KNOX BOX IN AN ACCESSIBLE LOCATION | | | ON THE APPROPIATE EXTERIOR ELEVATION..FOR | | | APPLICATIONS, CONTACT WPB FIRE PREVENTION BUREAU AT | | | 561-804-4724.ANY INQUIRIES AND/OR REQUIREMENTS TO | | | THIS MATTER SHALL BE WITH THE AHJ = CITY OF WEST PALM | | | BEACH, NOT PALM BEACH COUNTY | | | | | | 15.IN ADDITION TO THE ELECTRONIC SWITCHES FOR THE | | | DOUBLE CHECK DETECTOR ASSEMBLY (DCDA), CHAIN AND LOCK | | | WILL BE REQUIRED.ADD COMMENT TO AN APPROPIATEFP | | | SHEET | | | | | | 16.FLOW TEST DATA (03/28/07) WAS GATHERED BY PALM | | | BEACH COUNTY FIRE DEPARTMENT.IF THIS PROJECT IS TRULY | | | IN THE JURISDICTION OF THE CITY OF WEST PALM BEACH, WHY | | | WASN'T THE DATA SUPPLIED BY WEST PALM BEACH FIRE | | | RESCUE'S PREVENTION DIVISION.ANY INQUIRIES AND/OR | | | REQUIREMENTS TO THIS MATTER SHALL BE WITH THE AHJ = | | | CITY OF WEST PALM BEACH, NOT PALM BEACH COUNTY | | | | | | 17.KNOX LOCKING CAPS WILL BE REQUIRED ON THE FIRE | | | DEPARTMENT CONNECTIONS (FDC).CONTACT 561-804-4724 FOR | | | APPLICATIONS.ANY INQUIRIES AND/OR REQUIREMENTS TO | | | THIS MATTER SHALL BE WITH THE AHJ = CITY OF WEST PALM | | | BEACH, NOT PALM BEACH COUNTY | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-04 |
Time |
23:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-04 |
Time |
20:00 |
Sent To |
AD |
|
| Notes |
| 2007-09-04 23:47:02 | *****DENIED***** | | | | | | 01.ON SHEET G-001 UNDER APPLICABLE CODES, INCLUDE AS | | | LIFE SAFETY CODE:NFPA 101 2003 EDITION. | | | | | | 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.NFPA 13, STANDARD FOR THE INSTALLATION OF | | | SPRINKLER SYSTEMS, 2002 EDITION SHALL BE REFERENCED. | | | SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE FIRE | | | SPRINKLER SYSTEM INSTALLATION. | | | | | | 04.NFPA72, NATIONAL FIRE ALARM CODE, 2002 EDITION | | | SHALL BE REFERENCED.SEPARATE PLANS AND PERMIT WILL BE | | | REQUIRED FOR THE FIRE ALARM SYSTEM INSTALLATION. | | | | | | 05.FIRE ALARM SYSTEM TO BE CLASS A OR FULLY | | | ADDRESSIBLE. | | | | | | 06.FIRE ALARM SYSTEM SHALL BE UL CERTIFIED FOR | | | CENTRAL STATION SERVICE. | | | | | | 07.A KNOX-BOX WILL BE REQUIRED FOR THE BUILDING. SHOW | | | THE LOCATION OF THE KNOX BOX IN AN ACCESSIBLE LOCATION | | | ON THE APPROPIATE EXTERIOR ELEVATION..FOR | | | APPLICATIONS, CONTACT WPB FIRE PREVENTION BUREAU AT | | | 561-804-4724. | | | | | | 08.FIRE DOORS AND FIRE WINDOWS TO COMPLY WITH NFPA | | | 80. | | | | | | 09.SPECIFY THE INTERIOR WALL AND CEILING FINISH | | | MATERIALS FOR THE EXITS, EXIT CORRIDORS, AND OTHER | | | AREAS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 10.SPECIFY THE INTERIOR FLOOR FINISHES IN TERMS OF | | | CLASS I OR CLASS II. | | | | | | 11.ON THE APPROPIATE EXTERIOR ELEVATION, POST THE | | | NUMERICAL ADDRESS ON THE BUILDING VISIBLE FROM NORTH | | | MILITARY TRAIL.IT IS RECOMMENDED THAT THE FARTHER THE | | | BUILDING IS FROM THE ROADSIDE, THAT ADDRESS NUMBERS BE | | | LARGER THAN THE DIMENSION OF NO LESS THAN 6" IN HEIGHT | | | AND NO LESS THAN 1" IN WIDTH (AS REQUIRED BY WEST PALM | | | BEACH CODE) .IF A MONUMENT SIGN IS TO BE USED, | | | ADDRESS NUMBERS SHALL BE POSTED. | | | | | | 12.ON SHEET A-400, INDICATE FRONT AND REAR | | | ELEVATIONS. | | | | | | 13.UNABLE TO LOCATE ON SHEET A-500, THE OVERHEAD | | | GARAGE DOOR(S) SHOWN ON SHEET A-400'S EAST EXTERIOR | | | ELEVATION. | | | | | | 14.AS PER LOCAL REQUIREMENTS, DUCT SMOKE DETECTORS | | | SHALL INITIATE A GENERAL FIRE ALARM. | | | | | | 15.IN ADDITION TO THE ELECTRONIC SWITCHES FOR THE | | | DOUBLE CHECK DETECTOR ASSEMBLY (DCDA), CHAIN AND LOCK | | | WILL BE REQUIRED. | | | | | | 16.FLOW TEST DATA (03/28/07) WAS GATHERED BY PALM | | | BEACH COUNTY FIRE DEPARTMENT.IF THIS PROJECT IS TRULY | | | IN THE JURISDICTION OF THE CITY OF WEST PALM BEACH, WHY | | | WASN'T THE DATA SUPPLIED BY WEST PALM BEACH FIRE | | | RESCUE'S PREVENTION DIVISION. | | | | | | 17.KNOX LOCKING CAPS WILL BE REQUIRED ON THE FIRE | | | DEPARTMENT CONNECTIONS (FDC).CONTACT 561-804-4724 FOR | | | APPLICATIONS. | | | | | | 18.PLEASE EXPLAIN THE USAGE OF THE GENERATOR, THE | | | TYPE OF FUEL(S) THAT WILL BE UTILIZED, AND THE STORAGE | | | OF SUCH FUEL(S) & QUANTITIES STORED.SEPARATE PLANS | | | AND PERMIT WILL BE REQUIRED FOR ITS INSTALLATION. | | | | | | 19.STATIONARY GENERATORS FOR EMERGENCY USE OR STANDBY | | | POWER SHALL BE INSTALLED IN ACCORDANCE WITH NFPA110. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
P |
Date |
2009-08-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-20 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-20 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2009-08-20 09:45:07 | GAS REVISION OK -- P1-103 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2009-06-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-23 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-23 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2009-06-23 16:13:02 | REVISION DENIED | | | REFERENCE: | | | FBC-2004 FUEL GAS | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | 1. SHT P1-103 GAS ISOMETRIC. THE MINIMUM PIPE SIZING IS | | | NOT CORRECT ON SOME PIPES. 4" IS REQUIRED, (3,502 MBH @ | | | 125 FEET), FROM THE METER TO THE FIRST TEE. 3" IS | | | REQUIRED FOR 2,600 MBH. 2-1/2" IS REQUIRED FOR 1,300 | | | MBH. 2" IS REQUIRED FOR 902 MBH, (STILL SHOWN AS 750 | | | MBH). 2" IS REQUIRED FOR 750 MBH, (NO SIZE INDICATED). | | | TABLE 402.4(2). | | | ****RESPONSE NOTED, BUT THE REQUIREMENT FOR THE 3" PIPE | | | FOR 2,600 MBH AND THE REQUIREMENT FOR THE 2-1/2" FOR | | | THE 902 MBH HAS NOT BEEN ADDRESSED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2008-05-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-28 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-27 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2008-08-12 10:19:29 | SEPARATE GAS PERMIT REQUIRED |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-15 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-14 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2008-02-28 15:01:26 | DENIED.--SEE GAS COMMENTS ON PLUMBING PLAN REVIEW | | | STOP THIS DATE |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-23 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-23 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2007-08-23 16:28:41 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | 1. SHT P1-103 SEPARATE GAS PERMIT IS REQUIRED. THE | | | FOLLOWING REQUIREMENTS SHALL BE SUBMITTED FOR GAS | | | REVIEW: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | E. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (NOT SHOWN FOR GB1 | | | UNITS). | | | | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | G. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | H. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2009-11-18 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-11-18 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-11-18 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2009-11-18 17:05:45 | IN ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2009-09-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-02 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-02 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2009-09-02 13:33:12 | SENT TO FIRE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2009-08-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-08-14 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-14 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2009-08-14 14:18:15 | C-1, REVISION DELETING PHASE 2 FROM PHASE 1. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2009-07-29 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-07-29 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-07-29 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2009-07-29 09:29:15 | IN MECH. BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
|
Date |
2009-07-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-06 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-06-03 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2009-06-04 16:30:05 | REVISION TO C6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2009-05-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-05-27 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-05-27 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2009-05-28 16:38:32 | MECHANICAL AS-BUILTS, GAVE TO RON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2009-05-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-05-13 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-05-13 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2009-05-13 09:55:05 | INCOMINGTO MECHANICAL: SHOP DRAWINGS FOR DUCT WORK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2009-05-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-05-01 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-05-01 |
Time |
16:57 |
Sent To |
M |
|
| Notes |
| 2009-05-01 16:58:27 | | | | | | | TO RON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2009-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-02 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-02 |
Time |
10:03 |
Sent To |
B |
|
| Notes |
| 2009-02-02 10:05:36 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2009-01-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-27 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-27 |
Time |
11:13 |
Sent To |
B |
|
| Notes |
| 2009-01-27 11:13:19 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-19 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-19 |
Time |
09:26 |
Sent To |
B |
|
| Notes |
| 2008-12-19 09:28:36 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-12-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-12 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-12 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2008-12-12 15:07:55 | TO "COMM" BD#5/PLANS ON RACK/3 ROLLS/1 BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-04 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-04 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2008-08-04 13:14:33 | TO "COMM" BD#52/PLANS ON RACK, 4 ROLLS AND 1 BOX | | 2008-07-30 13:36:52 | 7/30/08 PLANS NEED TO BE SENT TO "Z" FOR LANDSCAPE | | | REVIEW.ADARROUGH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-05-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-13 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-13 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2008-05-13 16:28:49 | TO "COMM" BD#8--PLANS ON RACK/4 ROLLS, AND 1 BOX WITH | | | BINDERS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-17 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-17 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2008-01-17 11:26:08 | TO "COMM" BD#55/PLANS ON RACK--4 ROLLS, 1 BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-12-31 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-31 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-31 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2007-12-31 09:36:03 | TO COMM BOARD # 22 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-05 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-24 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2007-07-09 14:34:10 | TO "COMM"BD#22/PLANS ON RACK--3 ROLLS | | 2007-06-24 12:57:45 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
5 |
Status |
P |
Date |
2009-11-20 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-11-20 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-11-20 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
4 |
Status |
P |
Date |
2009-10-20 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-10-20 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-10-20 |
Time |
13:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-06-09 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-06-09 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-08-06 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-08-06 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-02-19 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-02-19 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2008-02-19 15:24:04 | 1. A NOTE INDICATING THAT ALL PROHIBITED PLANT SPECIES | | | SHALL BE REMOVED FROM THE DEVELOPMENT SITE SHALL APPEAR | | | ON THE LANDSCAPE PLAN. | | | | | | 2. PURSUANT TO SECTION 94-442(D), PRIVATE LAND AND | | | PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK | | | SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN | | | SPACE SHALL BE PLANTED WITH GRASS. THIS APPLIES TO ALL | | | RIGHTS-OF-WAY THAT ARE ADJACENT TO THE SITE. A NOTE | | | SHALL APPEAR ON THE LANDSCAPE PLAN. | | | | | | 3. ALL FENCING ADJACENT TO A RIGHT-OF-WAY SHALL BE | | | INSTALLED ALONG THE INSIDE PERIMETER OF THE LANDSCAPE | | | SETBACK WITH THE LANDSCAPING INSTALLED ON THE STREET | | | SIDE OF THE FENCE. THIS APPLIES TO 12TH STREET AND | | | MILITARY TRAIL. | | | | | | 4. SITE LIGHTING SHALL BE CENTERED BETWEEN PROPOSED | | | TREES. ALL CONFLICTS BETWEEN PROPOSED STREET LIGHTS AND | | | TREES SHALL BE RESOLVED PRIOR TO PERMITTING. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
12 |
Status |
P |
Date |
2009-11-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-11-04 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-11-04 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2009-11-04 09:28:51 | REVISED M1-102 DELTA 10, M1-103 DELTA 11, M1-105 DELTA | | | 10, M1-106 DELTA 10 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
11 |
Status |
P |
Date |
2009-08-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-04 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-04 |
Time |
16:44 |
Sent To |
PC |
|
| Notes |
| 2009-08-04 16:44:59 | REVISED M1-105 DELTA 9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
P |
Date |
2009-07-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-20 |
Time |
20:36 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-20 |
Time |
20:35 |
Sent To |
PC |
|
| Notes |
| 2009-07-20 20:36:46 | REVISED M1-101 THRU M1-106, M2-101, M3-101, M5-103 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-14 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-14 |
Time |
13:19 |
Sent To |
PC |
|
| Notes |
| 2009-07-14 13:20:44 | REVISION M1-101, M1-102, M1-103, M1-201 DELTA 9... | | | REVISION M1-104, M1-105, M1-106 DELTA 8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2009-06-03 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-06-03 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-06-03 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2009-06-03 16:04:15 | ACCEPTED INTERIM RECORD OF "AS-BUILT" CONDITION FOR USE | | | IN CONDUCTING ROUGH INSPECTIONS WITH THE FOLLOWING | | | PROVISIONS: | | | 1. APPLICANT IS RESPONSIBLE TO PROVIDE A MATCHING | | | REVISION WHICH IS SIGNED AND SEALED BY THE EOR FOR | | | REVIEW AND ACCEPTANCE PRIOR TO REQUESTING A FINAL | | | MECHANICAL INSPECTION. | | | 2. INTERIM PLAN SHALL BE VALID FOR ONLY ROUGH | | | INSPECTIONS | | | 3. APPLICANT AGREED TO PROCEED AT THEIR OWN RISK AND | | | WILL CORRECT ANY DISCREPANCIES WHICH ARE NOT APPROVED | | | BY THE EOR. | | | 4. AN APPROVED CITY COPY OF THE EOR REVISION SHALL BE | | | ON SITE FOR FINAL MECHANICAL INSPECTION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2009-05-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-29 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-29 |
Time |
08:18 |
Sent To |
PC |
|
| Notes |
| 2009-05-29 10:37:19 | M1-101, M1-102, M1-103, M2-101 REVISION 8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2009-05-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-05-05 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-05-05 |
Time |
09:38 |
Sent To |
PC |
|
| Notes |
| 2009-05-05 09:44:27 | REVIEW #: REVISION | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2007 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | PLANS SUBMITTED ARE LABELED AND STAMPED AS "SHOP | | | DRAWINGS." HOWEVER, THESE DRAWINGS INDICATE SEVERAL | | | CHANGES FROM THE PREVIOUSLY APPROVED CONSTRUCTION | | | DOCUMENTS (PERMIT SET OF PLANS). WORK SHALL BE | | | INSTALLED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION | | | DOCUMENTS, AND ANY CHANGES MADE DURING CONSTRUCTION | | | THAT ARE NOT IN COMPLIANCE WITH THE APPROVED | | | CONSTRUCTION DOCUMENTS SHALL BE RESUBMITTED FOR | | | APPROVAL AS AN AMENDED SET OF CONSTRUCTION DOCUMENTS IN | | | ACCORDANCE WITH FBC-B 106.4. PLEASE SUBMIT A REVISED | | | SET OF PLANS SIGNED AND SEALED BY THE DESIGNER OF | | | RECORD TO DOCUMENT THESE CHANGES. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2009-01-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-01-20 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-01-20 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2009-01-20 08:04:17 | REVISED ENTIRE SET OF MECHANICAL PLANS. REV 6. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-25 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-22 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2008-08-25 09:22:56 | *************PROVISO************** | | | | | | DOCUMENTATION FROM APPLIANCE MANUFACTURER SHALL BE | | | PROVIDED SHOWING ALL OUTDOOR APPLIANCES WHICH ARE | | | EXPOSED TO WIND ARE DESIGNED TO RESSIST WIND PRESSURES | | | IN ACCORDANCE WITH FBCM SECTION 301.13. THIS | | | INFORMATION SHALL BE SUBMITTED FOR PLAN REVIEW PRIOR TO | | | INSTALLATION OF OUTDOOR APPLIANCES. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-29 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-28 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2008-05-29 14:14:35 | REVIEW #: 3RD | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1-5: OK | | | | | | 6A ? 6C: OK | | | | | | 6D: A SYSTEM SIZING SUMMARY HAS BEEN PROVIDED IN LIEU | | | OF COOLING LOAD CALCULATIONS AS ALLOWED UNDER EXCEPTION | | | #1 OF FBCB 13-407.1.ABC.1. HOWEVER, THIS EXCEPTION | | | REQUIRES THAT THE SYSTEM SIZING SUMMARY BE SIGNED AND | | | SEALED BY THE DESIGN PROFESSIONAL. THE SYSTEM SIZING | | | SUMMARY WHICH WAS SUBMITTED IN RESPONSE TO THIS COMMENT | | | WAS NOT SIGNED AND SEALED. PLEASE CORRECT AND | | | RESUBMIT. | | | | | | 7. OK. LOUVERS INCLUDED IN PRODUCT APPROVAL PACKAGE AND | | | WILL BE REVIEWED BY BUILDING PLAN REVIEWER. | | | | | | 8-15: OK | | | | | | 16. FAN SCHEDULE ON PAGE M3-103 STILL CALLS FOR EF81 | | | AND EF 83 TO BE CONTROLLED BY LIGHT SWITCH RATHER THAN | | | INTERLOCKED WITH AH4 AS INDICATED IN WRITTEN RESPONSE | | | (DATED 3/14/08) TO PREVIOUS REVIEW COMMENT (DATED | | | 2/7/08) . PLEASE CORRECT AND RESUBMIT. FBCM 403.2.1. | | | | | | 17. OK | | | | | | 18. FAN SCHEDULE ON M3-103 STILL CALLS FOR EF84 TO BE | | | CONTROLLED BY WALL SWITCH RATHER THAN RUN CONTINUOUS AS | | | STATED IN WRITTEN RESPONSE (DATED 3/14/08) TO PREVIOUS | | | REVIEW COMMENT (DATED 2/7/08). FBCM 404. | | | | | | 19. OK | | | | | | 20. ATTACHMENT DETAILS WITH SUPPORTING CALCULATIONS | | | HAVE BEEN PROVIDED AND WILL BE REVIEWED BY THE BUILDING | | | PLAN REVIEWER. HOWEVER, NO INFORMATION WAS PROVIDED, AS | | | PREVIOUSLY REQUESTED, DEMONSTRATING THAT THE OUTDOOR | | | APPLIANCES ARE DESIGNED TO WITHSTAND ANTICIPATED WIND | | | PRESSURES IN ACCORDANCE WITH FBCM 301.13. | | | | | | 21 AND 22: OK | | | | | | 23. THE THROUGH-PENETRATION FIRESTOP DETAILS PROVIDED | | | ON PAGE M4-104 DO NOT INCLUDE ANY PENETRATING PIPES | | | WHICH ARE INSULATED. WHAT SYSTEM IS TO BE USED FOR | | | INSULATED PIPE? | | | | | | 24. OK | | | | | | 25. GENERATOR INFORMATION: PAGE E-203 INDICATES AN 840 | | | GALLON IN-BASE FUEL TANK IS TO BE USED. THE FOLLOWING | | | ISSUES NEED TO BE ADDRESSED: | | | A) AS STATED IN FIRST AND SECOND REVIEWS, PROPOSED | | | ABOVE GROUND FUEL STORAGE TANKS WITH A FUEL STORAGE | | | CAPACITY IN EXCESS OF 550 GALLONS SHALL BE SUBMITTED TO | | | PALM BEACH COUNTY DERM FOR APPROVAL PRIOR TO PERMIT | | | ISSUANCE. NO INFORMATION WAS PROVIDED WITH THIS | | | SUBMITTAL INDICATING THAT THE PROPOSED FUEL TANK AND | | | LOCATION HAVE BEEN APPROVED BY DERM. PBC DERM APPROVED | | | PLANS SHALL BE INCLUDED WITH EACH SET OF PLANS | | | SUBMITTED TO THIS JURISDICTION FOR PERMIT. SEE ORIGINAL | | | COMMENT #25 (DATED 7/23/07) FOR PBC DERM CONTACT | | | INFORMATION. | | | | | | B) THE SUBMITTAL PROVIDED FOR THE GENERATOR FUEL TANK | | | INDICATES THAT THE MAXIMUM CAPACITY FOR AN IN-BASE FUEL | | | TANK (WHICH IS SHOWN ON E-203) 77 GALLONS. THERE IS NO | | | 840 GALLON IN-BASE TANK OPTION, AS INDICATED ON PLANS, | | | IN THE SUBMITTAL FROM THE MANUFACTURER. PLEASE VERIFY | | | THE TYPE OF TANK TO BE USED AS WELL AS A CAPACITY FOR | | | THE TANK WHICH CORRESPONDS WITH THE MANUFACTURER?S | | | SUBMITTAL DATA. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-02-13 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-02-13 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-02-11 |
Time |
18:28 |
Sent To |
|
|
| Notes |
| 2008-02-13 07:43:31 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1 THROUGH 5: OK | | | | | | 6. THIS IS THE FIRST REVIEW OF THE ENERGY CALCULATIONS | | | AS THEY WERE NOT INCLUDED WITH THE ORIGINAL SUBMITTAL. | | | THE FOLLOWING DISCREPANCIES WERE FOUND IN THE ENERGY | | | CALCULATIONS: | | | A) THE DESIGN IPLV ON THE PLANT PORTION OF THE INPUT | | | DATA REPORT (IDR) DOES NOT CORRESPOND WITH THE IPLV ON | | | THE EQUIPMENT SCHEDULE. ADDITIONALLY, THE DATA IN THE | | | EQUIPMENT SCHEDULE DOES NOT CORRESPOND WITH THE | | | MANUFACTURER?S DATA FROM THEIR WEBSITE (WWW.TRANE.COM). | | | | | | B) THE IDR CALLS FOR 1.5 INCH THICK INSULATION ON | | | DOMESTIC HOT WATER PIPING, BUT THE SPECIFICATIONS | | | (SEC.15250) CALL FOR 1 INCH THICK INSULATION. | | | C) THE IDR CALLS FOR 2 INCH THICK INSULATION ON 2 INCH | | | CHILLED WATER HVAC PIPING AND THE SPECIFICATIONS | | | (SEC.15250) CALL FOR 1.5 INCH THICK INSULATION. | | | THE VALUES IN THE IDR SHALL MATCH THE VALUES ON THE | | | PLANS AND SPECIFICATIONS IN ACCORDANCE WITH FBC | | | 13-103.2 | | | D) COOLING LOAD CALCULATIONS FOR THE PURPOSE OF SYSTEM | | | SIZING SHALL BE APPENDED TO THE ENERGY CALCULATIONS IN | | | ACCORDANCE WITH FBC 13-407.1.ABC.1. | | | | | | 7. NO CUT SHEETS WERE FOUND IN THE PACKAGE SUBMITTED. | | | ALSO, NO LOUVERS WERE PROVIDED IN THE PRODUCT APPROVAL | | | BOOKLET. WALL LOUVERS ARE DEFINED AS PANEL WALLS PER | | | FAC RULE 9B-72 AND ARE SUBJECT TO THE FLORIDA PRODUCT | | | APPROVAL SYSTEM. PRODUCT APPROVALS SHALL BE APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD AND SUBMITTED PRIOR | | | TO PERMIT IN ACCORDANCE WITH FBC 106.3.3 | | | | | | 8 ? 13: OK | | | | | | 14. A 100% OUTSIDE AIR DUCT HAS BEEN ADDED TO AREA | | | SERVED BY BC-1. HOWEVER, THERE IS AN 8 INCH FLEX DUCT | | | SHOWN ON FLOOR PLAN, PAGE M1-102, WHICH IS PENETRATING | | | A TWO-HOUR FIRE RESISTANCE RATED WALL. SEE PAGE | | | LS-001SHOW HOW THIS PENETRATION IS TO BE PROTECTED IN | | | ACCORDANCE WITH FBC, M 607.5.2. | | | | | | 15. OK | | | | | | 16. THERE IS NO INDICATION ON PLANS AS TO HOW THIS | | | COMMENT WAS ADDRESSED. FAN SCHEDULE ONLY CALLS FOR | | | INTERLOCK WITH THE LIGHT SWITCH. WHAT PROVISIONS ARE | | | MADE TO ENSURE THE EFS ARE RUNNING WHENEVER BC-1 IS | | | RUNNING? SHOW COMPLIANCE WITH FBC, M 403.2.1(3). | | | | | | 17. THERE IS STILL A DETAIL FOR A DRYWELL ON PAGE | | | M4-101. WILL THERE STILL BE A DRYWELL AS PART OF THE | | | CONDENSATE DISPOSAL SYSTEM? | | | | | | 18. FAN SCHEDULE CALLS FOR EF84 TO BE CONTROLLED BY | | | WALL SWITCH. MECHANICAL VENTILATION SYSTEMS FOR | | | ENCLOSED PARKING GARAGES ARE NOT REQUIRED TO OPERATE | | | CONTINUOUSLY WHERE THE SYSTEM IS ARRANGED TO OPERATE | | | AUTOMATICALLY UPON DETECTION OF A CONCENTRATION OF | | | CARBON MONOXIDE OF 25 PARTS PER MILLION (PPM) BY | | | APPROVED AUTOMATIC DETECTION DEVICES IN ACCORDANCE WITH | | | FBC, M 404.1. IN LIEU OF BEING CONTROLLED BY APPROVED | | | CARBON MONOXIDE SENSOR(S) THE VENTILATION FAN FOR THE | | | SALLY PORT SHALL OPERATE CONTINUOUSLY AT A MINUM RATE | | | OF 1.5 CFM PER SQUARE FOOT IN ACCORDANCE WITH THIS | | | SECTION. AUTOMATIC OPERATION OF THE SYSTEM SHALL NOT | | | REDUCE THE CONTINUOUS VENTILATION RATE BELOW0.05 CFM | | | PER SQUARE FOOT OF THE FLOOR AREA AND THE SYSTEM SHALL | | | BE CAPABLE OF PRODUCING A VENTILATION RATE OF 1.5 CFM | | | PER SQUARE FOOT OF FLOOR AREA IN ACCORDANCE WITH FBC, M | | | 404.2 SHOW HOW THE CONTINUOUS OR VARIABLE RATES ARE TO | | | BE PROVIDED. IF A CARBON MONOXIDE DETECTION SYSTEM IS | | | EMPLOYED, SHOW LOCATION(S) OF DETECTOR(S) AND PROVIDE | | | MANUFACTURER?S SUBMITTAL AND INSTALLATION INSTRUCTIONS | | | FOR REVIEW. FBC 106.1.2. | | | | | | 19. OK | | | | | | 20. NO INFORMATION COULD BE FOUND IN STRUCTURAL PLANS | | | RELATED TO WIND LOADS OR ATTACHMENTS FOR MECHANICAL | | | EQUIPMENT AND APPLIANCES. MECHANICAL EQUIPMENT, | | | APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL | | | BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES | | | ON THE EQUIPMENT AND THE SUPPORTS AS DETERMINED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING PER | | | FBC, M 301.13. PLEASE NOTE THAT THIS CODE REQUIREMENT | | | NOT ONLY APPLIES TO ATTACHMENTS BUT TO THE EQUIPMENT | | | AND APPLIANCES THEMSELVES. IT INCLUDES BUT IS NOT | | | LIMITED TO ERUS, EXHAUST FANS, OUTSIDE AIR INTAKES AND | | | CHILLERS. PROVIDE DATA SHOWING EQUIPMENT, APPLIANCES | | | AND INSTALLATION METHODS SUFFICIENT TO WITHSTAND | | | ANTICIPATED WIND PRESSURES WITH SUPPORTING CALCULATIONS | | | TO DEMONSTRATE COMPLIANCE WITH THIS SECTION. | | | | | | 21 AND 22: OK | | | | | | 23. NO DETAIL OF ANY THROUGH-PENETRATION FIRESTOP | | | SYSTEM FOR PIPE PENETRATIONS OF FIRE-RESISTANCE RATED | | | ASSEMBLIES COULD BE FOUND ON PG P4-101 AS SPECIFIED IN | | | DESIGNER?S WRITTEN RESPONSE. THIS COMMENT HAS NOT BEEN | | | ADDRESSED. SHOW COMPLIANCE WITH FBC 712.3 AND 712.4. | | | | | | 24. OK | | | | | | 25. THIS COMMENT REMAINS ESSENTIALLY UNADDRESSED. AS | | | LONG AS THE GENERATOR IS SHOWN AS PART OF THIS PERMIT | | | APPLICATION, ALL RELEVANT INFORMATION (SEE PREVIOUS | | | REVIEW COMMENT #25) SHALL BE PROVIDED PRIOR TO PERMIT | | | ISSUANCE. | | | NOTE: ADDITIONAL COMMENTS ARE POSSIBLE DUE TO THE LACK | | | OF INFORMATION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-07-26 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-07-23 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2007-07-25 17:59:10 | --------------DENIED--------------- | | | | | | FBC 2004 CODE FAMILY WITH 2005 AND 2006 REVISIONS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | NOTE: LOCATIONS ON PLANS RELATED TO THE FOLLOWING | | | COMMENTS WERE MARKED ON ONE SET OF PLANS, WHEN | | | PRACTICAL, TO HELP CLARIFY THE NATURE AND LOCATION OF | | | THE COMMENTS. | | | | | | 1. M0-101: GENERAL NOTE 1(M) REFERENCES ASHRAE 62-01. | | | AS OF DECEMBER 8,2006 THE CORRECT STANDARD IS ASHRAE | | | 62.1-2004. FBC,M CH.15. PLEASE CORRECT. | | | | | | 2. M0-101: GENERAL NOTE 7 IS IN CONFLICT WITH | | | CONDENSATE DRAIN TRAP DETAIL ON M4-101. IS TRAP TO BE | | | AT STATIC +1" OR STATIC +2"? CONDENSATE DRAINS SHALL BE | | | TRAPPED AS REQUIRED BY THE EQUIPMENT OR APPLIANCE | | | MANUFACTURER. FBC,M 307.2.4 | | | | | | 3. M0-101: HVAC LEGEND SHOWS AN "OPTION" FOR FIRE | | | DAMPERS. FIRE DAMPER EXCEPTIONS HAVE CHANGED AND THE "5 | | | FOOT RULE" NO LONGER APPLIES. SEE FBC,M 607.5 FOR | | | REQUIREMENTS. THE UPDATED EXCEPTIONS DO NOT APPLY TO | | | 2-HOUR ASSEMBLIES AS ARE INDICATED ON LIFE SAFETY PLAN. | | | ALSO, PLANS SHALL CLEARLY INDICATE WHERE FIRE DAMPERS | | | ARE TO BE INSTALLED PER FBC,M 607.8. PLEASE REMOVE | | | "OPTIONAL" NOTES FROM PLANS AND INSTEAD SHOW ON PLANS | | | WHERE FIRE DAMPERS ARE REQUIRED AND TO BE INSTALLED. | | | ALSO SEE FBC 106.1.1. | | | | | | 4. M0-102: ASHRAE 62-2001 IS NOT CORRECT. SEE COMMENT | | | #1. | | | | | | 5. M0-102: AH1-AH4 AND AH7, PLEASE PROVIDE MISSING | | | INFORMATION ON SCHEDULES REGARDING ACTUAL REQUIRED | | | QUANTITIES (CFM/PERSON OR CFM/SQ FT WITH TOTAL FOR EACH | | | SPACE) OF OUTDOOR AIR, EVEN IF THE SYSTEM IS DESIGNED | | | TO SUPPLY FAR IN EXCESS OF THE MINIMUM REQUIREMENT. THE | | | SCHEDULES, AS SHOWN, DO OT CONTAIN ACCURATE | | | INFORMATION. EXAMPLE: AH7 IN LOBBY 301, SCHEDULE | | | INDICATES 8070 CFM OUTDOOR AIR IS REQUIRED. | | | NOTE: 13-409.1.ABC.1.1 VENTILATION SYSTEMS SHALL BE | | | DESIGNED TO BE CAPABLE OF REDUCING THE SUPPLY OF | | | OUTDOOR AIR TO THE MINIMUM VENTILATION RATES REQUIRED | | | BY SECTION 6.1.3 OF ASHRAE 62. SYSTEMS MAY BE DESIGNED | | | TO SUPPLY OUTSIDE AIR QUANTITIES EXCEEDING MINIMUM | | | LEVELS, BUT THEY SHALL BE CAPABLE OF OPERATING AT NO | | | MORE THAN MINIMUM LEVELS THROUGH THE USE OF RETURN | | | DUCTS, MANUALLY OR AUTOMATICALLY OPERATED CONTROL | | | DAMPERS, FAN VOLUME CONTROLS, OR OTHER DEVICES. | | | | | | 6. PROVIDE ENERGY CALCULATIONS AND ALL REQUIRED | | | ACCOMPANYING DOCUMENTATION. FBC 106.3.5, FBC | | | 13-400.0.ABC, FBC 13-400.3.ABC.2 | | | | | | 7. PROVIDE ALL REQUIRED SUBMITTALS FOR LISTED AND | | | LABELED EQUIPMENT AND MATERIALS SUCH AS AHUS, CHILLERS, | | | VAVS, FANS, PUMPS, ERVS, VALVES, FITTINGS, HEAT COILS. | | | PRODUCT APPROVAL IS REQUIRED FOR LOUVERS PER FAC RULE | | | 9B-72. | | | | | | 8. M1-101: DUCT SIZES ARE MISSING ON TWO EXHAUST DROPS | | | ON ERU 81. PLEASE CORRECT. | | | | | | 9. M1-101: ARE ERU81 AND ERU82 BOTH FEEDING AH7 THROUGH | | | THE SAME DUCT? IT APPEARS THAT THE OA RISER DUCT FOR | | | ERU82 IS INCORRECTLY MARKED AS THE RETURN/EXHAUST GRILL | | | IN THE CEILING ABOVE THE RECEPTION DESK. | | | | | | 10. M1-101: ERU81 AND 82 ARE BOTH FEEDING AH7. | | | ACCORDING TO CONTROL SEQUENCE DIAGRAM ON M5-101, AH AND | | | ERU DESIGNATION NUMBERS SHOULD CORRELATE. IT IS UNCLEAR | | | WHETHER AH7 AND AH* OR ERU81 AND ERU 82 ARE MISLABELED. | | | CONTROL DIAGRAM IDENTIFIES AH8 AS A 100% OA UNIT IN ONE | | | PLACE BUT INDICATES AH7 AS THE SAME IN ANOTHER. PLEASE | | | COORDINATE ALL THESE ISSUES SO PLANS, SCHEDULES AND | | | CONTROL DIAGRAMS CORRELATE. | | | | | | 11. M1-102: ON FLOOR PLANS, AH6 IS IN A MECHANICAL ROOM | | | ON FIRST FLOOR AND AH8 IS IN A STORAGE ROOM. HOWEVER, | | | ON EQUIPMENT SCHEDULE, BOTH ARE SHOWN TO BE ON THE | | | MEZANNINE LEVEL. PLEASE COORDINATE FLOOR PLANS AND | | | SCHEDULES. | | | | | | 12. M1-102: AH6 SUPPLY DUCT, LOCATION OF TRANSITION | | | BETWEEN 34X18 AND 34X16 DUCT IS NOT SHOWN. PLEASE | | | CLARIFY. | | | | | | 13. SMOKE DETECTORS ARE REQUIRED ON ALL SUPPLY, OUTSIDE | | | AIR AND EXHAUST DUCTS RELATED TO AH1, AH2, AH3, AH4 AND | | | AH7 PER FBC,M 607.2.2. ALSO ON SUPPPLY SIDE OF AH5, AH6 | | | AND BC-1 PER FBC,M 606.2.1. SOME ARE SHOWN ON PLANS AND | | | OTHERS ARE NOT. PLEASE SHOW LOCATION OF ALL DUCT SMOKE | | | DETECTORS. FBC 106.1.1 | | | | | | 14. PROVIDE VENTILATION INFORMATION FOR AREA BEING | | | SERVED BY BC-1 (DWELLING UNIT?) FBC 401.2. | | | | | | 15. SSHOW MEANS AND LOCATION OF DRYER EXHAUST PER FBC,M | | | 504.4. ALSO, VERIFY IF MAKE-UP AIR IS REQUIRED PER | | | FBC,M 504.5. | | | | | | 16. M1-102: EF 71 AND EF 73 SHALL BE INTERLOCKED WITH | | | BC-1 PER FBC,M 403.2.1(3) AND WITH BATHROOM LIGHTS PER | | | FBC,M 401.3. | | | | | | 17. PLEASE SHOW MEANS AND LOCATION OF ALL CONDENSATE | | | DISPOSAL, INCLUDING THE LOCATION OF DRYWELLS. FBC | | | 307.2.1 | | | | | | 18. "SALLY PORT" AREA SHALL BE VENTILATED PER FBC,M | | | TABLE 403.3 AND SEC 404. | | | | | | 19. NO INFORMATION COULD BE FOUND ON PLANS FOR VENTING | | | OR COMBUSTION AIR FOR GAS APPLIANCES IN THE MECHANICAL | | | ROOM ASIDE FROM GENERIC DETAIL FOR A WATER HEATER. IS | | | THE MECHANICAL ROOM A CONFINED SPACE? IF SO, PROVIDE | | | COMBUSTION AIR FOR A TOTAL OF 335,000 BTU/H PER FBC,FG | | | 304.5 AND SHOW SPECIFIC MEANS AND LOCATION OF VENTING | | | PER FBC,FG 503.2. | | | | | | 20. M4-101: ROOF EQUIPMENT SUPPORT DETAIL, PROVIDE | | | COMPLETE DETAIL FOR FASTENING OF CURBS AND SUPPORTS TO | | | STRUCTURE AS WELL AS ATTACHMENTS OF EQUIPMENT TO CURBS | | | AND SUPPORTS. PROVIDE WIND LOAD CALCULATIONS FOR | | | BUILDING PLAN REVIEW SHOWING THAT ALL ATTACHMENTS ARE | | | DESIGNED TO THE 140 MPH WIND ZONE PER FBC,M 301.13 AND | | | FBC CH.16. | | | | | | 21.M4-101: IF PATE CURBS ARE USED AS SUPPORTS, AND | | | ROOFING MATERIAL EXTENDS UNDER THE EQUIPMENT (INCLUDING | | | DUCTWORK), CLEARANCES ABOVE FINISHED ROOF SHALL BE IN | | | ACCORDANCE WITH FBC TABLE 1509.7, NOT NECESSARILY 14" | | | AS SHOWN ON DETAIL. | | | | | | 22. M4-101: FIRE DAMPERS SHALL BE INSTALLED IN | | | ACCORDANCE WITH THEIR LISTING AND MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS. FBC 607.2 | | | | | | 23. M4-102: PIPE PENETRATIONS OF RATED FLOOR/CEILING | | | ASSEMBLIES SHALL COMPLY WITH FBC 712.4. PIPE | | | PENETRATIONS OF RATED WALLS SHALL COMPLY WITH 712.3. | | | PROVIDE UL ASSEMBLY DETAILS AS REQUIRED. | | | | | | 24. BOTH OUTDOOR AIR SUPPLY AND EXHAUST SYSTEMS SHALL | | | BE EQUIPPED WITH MOTORIZED DAMPERS THAT WILL | | | AUTOMATICALLY SHUT WHEN THE SYSTEMS OR SPACES SERVED | | | ARE NOT IN USE. VENTILATION OUTSIDE AIR DAMPERS SHALL | | | BE CAPABLE OF AUTOMATICALLY SHUTTING OFF DURING | | | PREOCCUPANCY BUILDING WARMUP, COOLDOWN, AND SETBACK, | | | EXCEPT WHEN VENTILATION REDUCES ENERGY COSTS (E.G., | | | NIGHT PURGE) OR WHEN VENTILATION MUST BE SUPPLIED TO | | | MEET CODE REQUIREMENTS. FBC 13-409.1.ABC.3.3 | | | | | | 25. NO INFORMATION WAS PROVIDED REGARDING EMERGENCY | | | GENERATOR AS SHOWN ON E-301. PLEASE PROVIDE PLANS, | | | SPECIFICATIONS, LOCATION ON SITE PLAN FOR GENERATOR AND | | | FUEL TANK. SHOW DISTANCE FROM PROPERTY LINES, ADJACENT | | | BUILDINGS AND ANY OPENINGS INTO BUILDINGS WITHIN 10' OF | | | GENERATOR EXHAUST. ALL ABOVE GROUND FUEL TANKS OF 550 | | | GALLONS OR MORE REQUIRE PALM BEACH COUNTY DERM APPROVAL | | | PRIOR TO PERMITTING BY THE CITY OF WEST PALM BEACH. FOR | | | MORE INFORMATION CONTACT DERM DIRECTLY AT 561-233-2400 | | | OR VISIT WWW.PBCGOV.COM/ERM. | | | | | | NOTE: ADDITIONAL COMMENTS MAY BE GENERATED BASED ON THE | | | NATURE AND COMPLETENESS OF INFORMATION WHICH IS TO BE | | | PROVIDED IN RESPONSE TO THIS REVIEW. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
3 |
Status |
P |
Date |
2009-08-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-20 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-20 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2009-08-20 13:56:39 | REVISION SUBMITTED 8-13-09 OK |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
2 |
Status |
P |
Date |
2009-06-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-23 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-23 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2009-06-23 15:55:36 | | | | | | | | | | SEPARATE MED-GAS PERMIT REQUIRED. | | | OXYGEN SHALL BE INSTALLED PER LEVEL 3 GAS REQUIREMENTS | | | OF NFPA 99C-99. | | | | | | | | | . |
|
|
| Review Stop |
MEDGAS |
MEDICAL GAS |
| Rev No |
1 |
Status |
F |
Date |
2009-01-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-27 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-27 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2009-01-27 08:07:21 | DENIED | | | REFERENCE: | | | NFPA 99C MED-GAS | | | | | | NEW SHEET ADDED: SEPARATE MED-GAS PERMIT REQUIRED. | | | | | | 1. SHT P8-101 PLEASE INDICATE THE LOCATION OF THE VENT | | | FOR THE VACUUM SYSTEM. SECTIONS 4-5.2.1.4 & 4-5.2.1.5. | | | CLEANOUTS ARE REQUIRED PER SECTION 4-5.2.2.3. PLEASE | | | INDICATED ON RISER DIAGRAM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
F |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-28 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-28 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2009-10-28 16:27:33 | REVISIONS DENIED FOR SHTS IR-1, IR-2 & IR-3. REVISIONS | | | SUBMITTED HAVE LATEST REVISION AS REVISION #6 DATED | | | DEC. 21 2007 BUT SHEETS ON FILE FOR PUBLIC RECORD HAVE | | | LATEST REVISION AS REVISION #7 DATED JULY 6, 2009. | | | IRRIGATION SHTS TO BE RETURNED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
P |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-28 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-28 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2009-10-28 16:23:42 | REVISIONS OK -- SHTS P1-102, P1-105, P2-101, P3-101 & | | | P6-101. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
P |
Date |
2009-09-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-08 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-08 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2009-09-08 08:56:00 | REVISION OK -- SHTS IR-1, IR-2 & IR-3. (REVISION 7). |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2009-08-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-20 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-20 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2009-08-20 13:55:19 | DENIED | | | REFERENCE: | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P1-102 ON FILE FOR PUBLIC RECORD SHOWS REVISION | | | #6 DATED 11-7-2008. THE NEW REVISED SHEET SUBMITTED | | | 8-13-2009 SHOWS REVISION 6 DATED 9-4-2008. A REVISION | | | #6 IS ALREADY ON FILE. NEW REVISION NUMBERS ARE | | | REQUIRED FOR EACH NEW REVISION AND THE REVISION HISTORY | | | SHALL REMAIN THRU THE LIFE OF THE PROJECT. SECTION | | | 106.1.3. NO CHANGES TO THE PLUMBING WAS NOTED ON THIS | | | SHEET. PLEASE CLARIFY. | | | | | | 2. SHT P1-105 ON FILE FOR PUBLIC RECORD SHOWS REVISION | | | #3 DATED 12-27-2007 & REVISION #6 DATED 11-7-2008. THE | | | REVISED NEW SHEET SUBMITTED 8-13-09 ONLY SHOWS | | | REVISIONS 1 & 2 WHICH ARE ALREADY ON FILE. PLEASE | | | INDICATE NEW REVISIONS WITH CLOUDS AND NEW REVISION | | | NUMBERS. THE REVISION HISTORY SHALL REMAIN THRU THE | | | LIFE OF THE PROJECT. SECTION 106.1.3. NO CHANGES TO THE | | | PLUMBING WAS NOTED ON THIS SHEET. PLEASE CLARIFY. | | | | | | 3. SHT P2-101 ON FILE FOR PUBLIC RECORD SHOWS REVISION | | | #6 DATED 11-7-2008. THE NEW REVISED SHEET SUBMITTED | | | 8-13-2009 SHOWS REVISION #6 DATED 9-4-2008. PLEASE | | | INDICATE NEW REVISIONS WITH CLOUDS AND NEW REVISION | | | NUMBERS. THE REVISION HISTORY SHALL REMAIN THRU THE | | | LIFE OF THE PROJECT. SECTION 106.1.3. NO CHANGES TO THE | | | PLUMBING WAS NOTED ON THIS SHEET. PLEASE CLARIFY. | | | | | | 4. SHT P3-101 ON FILE FOR PUBLIC RECORD SHOWS REVISION | | | #6 DATED 11-7-2008. THE NEW REVISED SHEET SUBMITTED | | | 8-13-2009 SHOWS REVISION 6 DATED 9-4-2008. PLEASE | | | INDICATE NEW REVISIONS WITH CLOUDS AND NEW REVISION | | | NUMBERS. THE REVISION HISTORY SHALL REMAIN THRU THE | | | LIFE OF THE PROJECT. SECTION 106.1.3. NO CHANGES TO THE | | | PLUMBING WAS NOTED ON THIS SHEET. PLEASE CLARIFY. | | | | | | 5. SHT P6-101 ON FILE FOR PUBLIC RECORD SHOWS REVISION | | | #6 DATED 11-7-2008. THE NEW REVISED SHEET SUBMITTED | | | 8-13-2009 SHOWS REVISION 6 DATED 9-4-2008. PLEASE | | | INDICATE NEW REVISIONS WITH CLOUDS AND NEW REVISION | | | NUMBERS. THE REVISION HISTORY SHALL REMAIN THRU THE | | | LIFE OF THE PROJECT. SECTION 106.1.3. NO CHANGES TO THE | | | PLUMBING WAS NOTED ON THIS SHEET. PLEASE CLARIFY. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2009-06-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-18 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-18 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2009-06-18 16:57:16 | REVISION DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | NFPA 99C MED-GAS | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | 1. SHT P1-103 GAS ISOMETRIC. THE MINIMUM PIPE SIZING IS | | | NOT CORRECT ON SOME PIPES. 4" IS REQUIRED, (3,502 MBH @ | | | 125 FEET), FROM THE METER TO THE FIRST TEE. 3" IS | | | REQUIRED FOR 2,600 MBH. 2-1/2" IS REQUIRED FOR 1,300 | | | MBH. 2" IS REQUIRED FOR 902 MBH, (STILL SHOWN AS 750 | | | MBH). 2" IS REQUIRED FOR 750 MBH, (NO SIZE INDICATED). | | | TABLE 402.4(2). | | | ****RESPONSE NOTED, BUT THE REQUIREMENT FOR THE 3" PIPE | | | FOR 2,600 MBH AND THE REQUIREMENT FOR THE 2-1/2" FOR | | | THE 902 MBH HAS NOT BEEN ADDRESSED. | | | | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-26 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-26 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2009-01-26 16:58:15 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | NFPA 99C MED-GAS | | | | | | 1. SHT P1-103 GAS ISOMETRIC. THE MINIMUM PIPE SIZING IS | | | NOT CORRECT ON SOME PIPES. 4" IS REQUIRED, (3,502 MBH @ | | | 125 FEET), FROM THE METER TO THE FIRST TEE. 3" IS | | | REQUIRED FOR 2,600 MBH. 2-1/2" IS REQUIRED FOR 1,300 | | | MBH. 2" IS REQUIRED FOR 902 MBH, (STILL SHOWN AS 750 | | | MBH). 2" IS REQUIRED FOR 750 MBH, (NO SIZE INDICATED). | | | TABLE 402.4(2). | | | | | | 2. SHT P1-103 REVISIONS 4 & 5 NOT FOUND OR APPROVED. | | | PLEASE INDICATE WHERE THESE REVISIONS CAN BE FOUND BY | | | CLOUDING THE REVISIONS AND INDICATING WITH REVISION | | | NUMBERS. SECTION 106.1.3. | | | | | | 3. SHT P1-104 INDICATES REVISIONS 3, 4, 5 & 6. THIS | | | SHEET ON FILE FOR PUBLIC RECORD SHOWS REVISIONS 1 & 2 | | | ONLY. NO REVISION CLOUDS OR REVISION NUMBERS ARE | | | INDICATED ON THE SHEET SUBMITTED FOR REVIEW. PLEASE | | | CLOUD AND NUMBER ALL REVISIONS AFTER REVISION 2. | | | SECTION 106.1.3. | | | | | | 4. SHT P 4-101 INDICATES REVISIONS 5 & 6. THIS SHEET ON | | | FILE FOR PUBLIC RECORD SHOWS REVISIONS 1, 2, 3 & 4. NO | | | REVISION CLOUDS OR REVISION NUMBERS ARE INDICATED ON | | | THE SHEET SUBMITTED FOR REVIEW. PLEASE CLOUD AND NUMBER | | | ALL REVISIONS AFTER REVISION 2. SECTION 106.1.3. | | | | | | 5. SHT P5-101 INDICATES REVISIONS 3, 4, 5 & 6. THIS | | | SHEET ON FILE FOR PUBLIC RECORD SHOWS REVISIONS 1 & 2 | | | ONLY. NO REVISION CLOUDS OR REVISION NUMBERS ARE | | | INDICATED ON THE SHEET SUBMITTED FOR REVIEW. PLEASE | | | CLOUD AND NUMBER ALL REVISIONS AFTER REVISION 2. | | | SECTION 106.1.3. | | | | | | 6. SHT P7-101 INDICATES REVISIONS 3, 4, 5 & 6. THIS | | | SHEET ON FILE FOR PUBLIC RECORD SHOWS REVISIONS 1 & 2 | | | ONLY. NO REVISION CLOUDS OR REVISION NUMBERS ARE | | | INDICATED ON THE SHEET SUBMITTED FOR REVIEW. PLEASE | | | CLOUD AND NUMBER ALL REVISIONS AFTER REVISION 2. | | | SECTION 106.1.3. | | | | | | 7. SHT P8-101 PLEASE INDICATE THE LOCATION OF THE VENT | | | FOR THE VACUUM SYSTEM. SECTIONS 4-5.2.1.4 & 4-5.2.1.5. | | | CLEANOUTS ARE REQUIRED PER SECTION 4-5.2.2.3. PLEASE | | | INDICATE ON RISER DIAGRAM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2009-01-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-01-26 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-01-23 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2009-01-26 16:38:49 | REVISIONS OK -- SHTS P0-1-1 (REVISIONS 3,4 & 5 NOT | | | FOUND OR APPROVED), P1-101 (REVISIONS 3,4 & 5 NOT FOUND | | | OR APPROVED), P1-102 (REVISIONS 3,4 & 5 NOT FOUND OR | | | APPROVED), P1-105 (REVISIONS 4 & 5 NOT FOUND OR | | | APPROVED), P2-101 (REVISION 5 NOT FOUND OR APPROVED), | | | P3-101 (REVISION 5 NOT FOUND OR APPROVED), P4-102 (NEW | | | SHEET), P6-101 (REVISION 5 NOT FOUND OR APPROVED). |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-12 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-12 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2008-08-12 10:20:03 | SEPARATE PLUMBING & IRRIGATION PERMITS REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-05-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-05-28 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-05-27 |
Time |
12:38 |
Sent To |
|
|
| Notes |
| 2008-05-28 15:09:13 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | CITY WPB MUNICIPAL CODE | | | | | | ****FROM PREVIOUS REVIEW: (2ND REVIEW) | | | | | | ******FROM PREVIOUS REVIEWS: (3RD REVIEW) | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | 9. OK | | | 10. OK | | | 11. OK | | | 12. OK | | | 13. OK | | | | | | 14. SHT A-709 DETAILS 79 & 81. SHOW COMPLIANCE WITH | | | SECTION 11-4.24 & ALL SUBSECTIONS. NOTE: FORWARD | | | APPROACH REQUIRED ON CLEAR FLOOR SPACE AND CABINET | | | DOORS ARE NOT APPROVED IN THE CLEAR FLOOR SPACE. | | | ****RESPONSE NOTED, BUT SHT A-709 DETAILS 79 & 81 SHOW | | | THE FLOOD RIM LEVEL, (COUNTER TOP), AT 3'0". PER CODE | | | 34" IS MAXIMUM HEIGHT ALLOWED. SECTION 11-4.24.2. ALSO | | | NOT SHOWN IS THE SINK DEPTH, SECTION 11-4.24.4, THE | | | CLEAR FLOOR SPACE, SECTION 11-4.24.5, OR COMPLIANCE FOR | | | THE FAUCET, SECTION 11-4.24.7. | | | ******RESPONSE NOTED, BUT THE FOLLOWING IS STILL NOT | | | SHOWN: THE SINK DEPTH, SECTION 11-4.24.4, THE CLEAR | | | FLOOR SPACE, SECTION 11-4.24.5, OR COMPLIANCE FOR THE | | | FAUCET, SECTION 11-4.24.7. ALSO INDICATE THE CLEARANCE | | | REQUIRED BY SECTION 11-4.24.3. | | | | | | 15. OK | | | 16. OK | | | 17. OK | | | 18. OK | | | | | | 19. SHT P1-101 SUBMIT A DETAIL FOR THE CANINE | | | PRE-OP/POST-OP KENNELS. SHOW A DETAIL FOR THE WATER | | | BACKFLOW PROTECTION AND CONNECTION TO THE DOG BOWLS. | | | SECTION 608. SHOW THE CONNECTION TO THE TRENCH DRAINS | | | AND THE SN-1 FIXTURES. SECTION 106.1.2. (SN-1 FIXTURES | | | NOT SHOWN ON THE ISOMETRIC RISER DIAGRAM. CLARIFY). | | | ****RESPONSE NOTED, BUT IT WAS A SELECTIVE RESPONSE. NO | | | DETAIL FOR THE CANINE PRE-OP/POST-OP KENNELS WERE | | | SUBMITTED. ALSO NO DETAIL FOR THE BACKFLOW PROTEDTION | | | TO THE CONNECTION TO THE DOG BOWLS IS INDICATED ON SHT | | | P2-101. THE ONLY BACKFLOW PROTECTION SHOWN IS FOR THE | | | P-16 FIXTURES. INDICTE MANUFACTURE AND MODEL OF | | | BACKFLOW PER TABLE 608.1. | | | ******RESPONSE NOTED, BUT BACKFLOW PREVENTERS SHALL BE | | | INSTALLED MAXIMUM 4 FEET ABOVE THE FLOOR FOR SERVICING | | | AND TESTING. THE BACKFLOW PREVENTER IN THE RECESSED | | | SHALL BE ACCESSIBLE FOR SERVICING & TESTING ALSO. | | | | | | 20. SHT P1-103 SEPARATE GAS PERMIT IS REQUIRED. THE | | | FOLLOWING REQUIREMENTS SHALL BE SUBMITTED FOR GAS | | | REVIEW: | | | | | | A. OK | | | B. OK | | | C. OK | | | D. OK | | | E. OK | | | F. OK | | | G. N/A | | | H. N/A | | | | | | 21. OK | | | 22. OK | | | 23. OK | | | 24. OK | | | 25. OK | | | 26. OK | | | | | | 27. SHT P3-101 SHOW ALL PIPE SIZES AND INDICATED ON THE | | | SANITARY ISOMETRIC RISER DIAGRAM THE DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM. TABLES 709.1, 710.1(1) & | | | 710.1(2). | | | ****RESPONSE NOTED, BUT THE DFU'S ARE NOT INDICATED AS | | | THEY ACCUMULATE IN THE SYSTEM. | | | ******RESPONSE NOTED, BUT MANY PIPE SIZES ARE NOT | | | SHOWN. (EXAMPLE: ALL PIPING TO THE CAGES FOR PRE-OP & | | | POST-OP). | | | | | | 28. OK | | | 29. OK | | | 30. OK | | | 31. OK | | | 32. OK | | | 33. OK | | | 34. OK | | | | | | 35. SUBMIT STORM RISER DIAGRAMS . SHOW ALL PIPE SIZES & | | | INDICATE SQUARE FOOTAGE AS IT ACCUMULATES IN THE | | | SYSTEM. ALSO SHOW ALL CLEANOUTS REQUIRED BY SECTION | | | 1101.8. (ALSO SHOW CLEANOUTS ON SHT P1-105). | | | 106.3.5.1.3(7)(13). | | | ****RESPONSE NOTED, BUT THE SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM IS NOT INDICATED. | | | ******RESPONSE NOTED, BUT THE SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM IS STILL NOT INDICATED ON THE | | | RISER DIAGRAM. ALSO PER TABLE 1106.3, MINIMUM 6" PIPE | | | IS REQUIRED FOR 1625SF @ 1/8"/FT. | | | | | | 36. OK | | | 37. OK | | | | | | 38. SHT P4-101 PACKAGED WATER HEATER-STORAGE | | | RECIRCULATION SYSTEM GWH-1. THE COLD WATER SUPPLY TURNS | | | INTO HOT WATER SUPPLY AFTER THE DROP. PLEASE CLARIFY. | | | --THE COLD WATER SUPPLY IS SHOWN TO THE STORAGE TANK. | | | PLEASE EXPLAIN.--HOT & COLD INLETS TO THE STORAGE | | | TANK? CLARIFY. SECTION 106.1.1.--A VACUUM RELIEF | | | VALVE IS REQUIRED FOR ALL BOTTOM FED WATER HEATERS. | | | SECTION 504.2.--THE FLOOR DRAIN IS NOT AN APPROVED | | | INDIRECT WASTE RECEPTOR. A FLOOR SINK OR A HUB DRAIN IS | | | REQUIRED. SECTIONS 802.3 & 802.3.2. | | | ****RESPONSE NOTED, BUT NO CLARIFICATION OF HOW THE | | | COLD WATER SUPPLY TURNS INTO THE HOT WATER SUPPLY. | | | ******RESPONSE NOTED, BUT THE COLD WATER IS STILL SHOWN | | | AS COLD WATER TO THE WATER HEATER, BUT HOT WATER TO THE | | | STORAGE TANK. ALSO THE PUMP IS INDICATED AS PUMPING THE | | | HOT WATER FROM THE STORAGE TANK AND INTO THE HOT WATER | | | HEATER. PLEASE SHOW THE PUMP AS PUMPING FROM THE WATER | | | HEATER AND INTO THE STORAGE TANK AND INDICATE DIRECTION | | | OF FLOW.--THE MANUF. PIPING DIAGRAM STATES "THIS | | | ILLUSTRATION IS FOR CONCEPT ONLY AND SHOULD NOT BE USED | | | FOR ACTUAL INSTALLATION WITHOUT ENGINEERING OR | | | TECHNICAL ADVICE FROM A LICENSED ENGINEER." | | | | | | 39. OK | | | | | | | | | **********NEW COMMENT********** | | | | | | 1B. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | ****NO RESPONSE FOR THE REQUEST TO SUBMIT ONE SET OF | | | OLD/VOID SHEETS TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-02-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-15 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-14 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2008-02-15 10:37:01 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | CITY WPB MUNICIPAL CODE | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | 2. OK | | | | | | 3. CIVIL DRAWINGS. THE ADDRESS FOR THE ENGINEERING | | | CONPANY IN THE TITLE BLOCK DOES NOT REFLECT THE ADDRESS | | | INDICATED ON THE FLORIDA STATE DBPR WEBSITE. PLEASE | | | UPDATE THE WEBSITE OR THE TITLE BLOCKS PRIOR TO | | | RESUBMITTING. ALSO THE ENGINEER SHALL LEGIBLY INDICATE | | | HER ADDRESS IN THE TITLE BLOCK.FAC 61G15-23.002(2) & | | | FS 471.025. PLEASE INDICATE ENGINEER'S ADDRESS. | | | ****RESPONSE NOTED, BUT THE ADDRESS INDICATED IN THE | | | DBPR WEBSITE IS 6380 SANDY HILL WAY LAKE WORTH FLA | | | 33463, NOT 120 S. OLIVE AVE. ETC. AS INDICATED IN THE | | | TITLE BLOCK. BUSINESS LICENSE NUMBER IS 9664 AS SHOWN | | | ON THE TITLE BLOCK THE CORPORATION NUMBER IS OF NO | | | RELEVANCE TO THIS COMMENT. | | | | | | 4. OK | | | | | | 5. ALL ARCHITECTURAL SHEETS. THE SIGNATURE IS REQUIRED | | | FOR THE ARCHITECT. IT APPEARS THAT INITIALS HAVE BEEN | | | USED. IF THIS IS INDEED THE LEGAL SIGNATURE OF THE | | | ARCHITECT, THEN A SIGNED, SEALED, DATED, NOTORIZED | | | LETTER INDICATING THE LEGAL SIGNATURE OF THE ARCHITECT | | | SHALL BE SUBMITTED FOR OUR FILES. FAC 61G1-16.003, | | | 61G1-16.004(5) & FS 481.2055. | | | ****RESPONSE NOTED, BUT THE SEAL IS STILL SIGNED WITH | | | WHAT APPEARS TO BE INITIALS AND NO LETTER HAS BEEN | | | SUBMITTED. | | | | | | 6. OK | | | 7. OK | | | 8. OK | | | 9. OK | | | 10. OK | | | 11. OK | | | | | | 12. SHT A-300 UPPER ROOF AT N.E. CORNER INDICATES R5 AS | | | AN O.S. PLEASE CLARIFY.--LOWER ROOF DRAINS ARE | | | INDICATED AS O.S., NOT PRIMARY SCUPPER DRAINS. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | ****RESPONSE NOTED, BUT DETAIL R7/A302 DOES NOT REFLECT | | | THE PARAPET FOR THE UPPER ROOF. SECONDARY ROOF DRAIN | | | REQUIRED. (SEE DETAIL R4/A-301). | | | | | | 13. SHT A-300 INDICATES R15 FOR THE SCUPPER WITH | | | DOWNSPOUT & O.S. R15 SHOWS NO COLLECTOR HEAD OR | | | DOWNSPOUT. ALSO SHEET A-400 SHOWS NO DOWNSPOUTS. PLEASE | | | CLARIFY AND INDICATE THE SIZE OF THE DOWNSPOUTS AND | | | SHOW COLLECTOR HEAD WITH DIMENSIONS. TABLES 1106.3 & | | | 1106.7.--ALSO INDICATE HOW THE PRIMARY DRAIN & O.S. | | | CAN BE AT THE ROOF LEVEL. SECTIONS 1503.4.2 & | | | 1503.4.3. | | | ****RESPONSE NOTED, BUT COMMENT NOT ADDRESSED. DETAIL | | | R15 STILL DOES NOT SHOW A COLLECTOR HEAD OR | | | DOWNSPOUTS. | | | | | | 14. SHT A-709 DETAILS 79 & 81. SHOW COMPLIANCE WITH | | | SECTION 11-4.24 & ALL SUBSECTIONS. NOTE: FORWARD | | | APPROACH REQUIRED ON CLEAR FLOOR SPACE AND CABINET | | | DOORS ARE NOT APPROVED IN THE CLEAR FLOOR SPACE. | | | ****RESPONSE NOTED, BUT SHT A-709 DETAILS 79 & 81 SHOW | | | THE FLOOD RIM LEVEL, (COUNTER TOP), AT 3'0". PER CODE | | | 34" IS MAXIMUM HEIGHT ALLOWED. SECTION 11-4.24.2. ALSO | | | NOT SHOWN IS THE SINK DEPTH, SECTION 11-4.24.4, THE | | | CLEAR FLOOR SPACE, SECTION 11-4.24.5, OR COMPLIANCE FOR | | | THE FAUCET, SECTION 11-4.24.7. | | | | | | 15. OK | | | 16. OK | | | 17. OK | | | | | | 18. SHT P1-101. SUBMIT THE MANUF. SPECIFICATION SHEETS | | | FOR THE SN-1 FIXTURE INCLUDING INSTALLATION | | | INSTRUCTIONS. SECTION 106.1.2. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. TABLE 604.3 | | | & 604.5, SECTION 608.2. | | | | | | 19. SHT P1-101 SUBMIT A DETAIL FOR THE CANINE | | | PRE-OP/POST-OP KENNELS. SHOW A DETAIL FOR THE WATER | | | BACKFLOW PROTECTION AND CONNECTION TO THE DOG BOWLS. | | | SECTION 608. SHOW THE CONNECTION TO THE TRENCH DRAINS | | | AND THE SN-1 FIXTURES. SECTION 106.1.2. (SN-1 FIXTURES | | | NOT SHOWN ON THE ISOMETRIC RISER DIAGRAM. CLARIFY). | | | ****RESPONSE NOTED, BUT IT WAS A SELECTIVE RESPONSE. NO | | | DETAIL FOR THE CANINE PRE-OP/POST-OP KENNELS WERE | | | SUBMITTED. ALSO NO DETAIL FOR THE BACKFLOW PROTEDTION | | | TO THE CONNECTION TO THE DOG BOWLS IS INDICATED ON SHT | | | P2-101. THE ONLY BACKFLOW PROTECTION SHOWN IS FOR THE | | | P-16 FIXTURES. INDICTE MANUFACTURE AND MODEL OF | | | BACKFLOW PER TABLE 608.1. | | | | | | 20. SHT P1-103 SEPARATE GAS PERMIT IS REQUIRED. THE | | | FOLLOWING REQUIREMENTS SHALL BE SUBMITTED FOR GAS | | | REVIEW: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | ****RESPONSE NOTED, BUT NOT ALL SECTIONS OF PIPE SHOW | | | THE CORRESPONDING LENGHTS AS REQUIRED. ALSO THE PIPING | | | IS NOT CLEAR AT THE GB1 APPLIANCES. (DELETE BACKGROUND | | | FLOOR PLAN & GAS APPLIANCES). | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. ****RESPONSE | | | NOTED, BUT SPECIFICATION 15483 IS REFERENCED AS BEING | | | DESIGNED BY FBC-2001. THE ADOPTED CODE IS FBC-2004. | | | PLEASE CHECK THE INFORMATION IS THE SPECIFICATION BOOKS | | | AS THEY WILL BE REVIEWED COMPLETLY UPON RESUBMISSION | | | AND THEY SHALL BE REQUIRED TO REFLECT THE PLANS TO BE | | | APPROVED. | | | | | | C. OK | | | D. OK | | | E. OK | | | | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ****RESPONSE NOTED, BUT THE GAS PLANS WILL NOT BE | | | APPROVED UNTIL THE COMMENT IS COMPLIED WITH. COMMENT | | | NOT ADDRESSED. | | | | | | G. N/A | | | H. N/A | | | | | | 21. OK | | | | | | 22. SHT P1-105 A RELIEF VENT, (GOOSE-NECK) FITTING | | | SHALL BE INSTALLED IN THE CONDENSATE DRAIN LINE AS IT | | | EXITS THE BUILDING. | | | ****RESPONSE NOTED, BUT P1-105 DOES NOT REFLECT THE | | | RISER DIAGRAM ON SHT P1-101. PLEASE CORRELATE. SECTION | | | 106.1.1. | | | | | | 23. OK | | | 24. OK | | | 25. OK | | | 26. OK | | | | | | 27. SHT P3-101 SHOW ALL PIPE SIZES AND INDICATED ON THE | | | SANITARY ISOMETRIC RISER DIAGRAM THE DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM. TABLES 709.1, 710.1(1) & | | | 710.1(2). | | | ****RESPONSE NOTED, BUT THE DFU'S ARE NOT INDICATED AS | | | THEY ACCUMULATE IN THE SYSTEM. | | | | | | 28. OK | | | 29. OK | | | 30. OK | | | 31. OK | | | 32. OK | | | 33. OK | | | 34. OK | | | | | | 35. SUBMIT STORM RISER DIAGRAMS . SHOW ALL PIPE SIZES & | | | INDICATE SQUARE FOOTAGE AS IT ACCUMULATES IN THE | | | SYSTEM. ALSO SHOW ALL CLEANOUTS REQUIRED BY SECTION | | | 1101.8. (ALSO SHOW CLEANOUTS ON SHT P1-105). | | | 106.3.5.1.3(7)(13). | | | ****RESPONSE NOTED, BUT THE SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM IS NOT INDICATED. | | | | | | 36. OK | | | 37. OK | | | | | | 38. SHT P4-101 PACKAGED WATER HEATER-STORAGE | | | RECIRCULATION SYSTEM GWH-1. THE COLD WATER SUPPLY TURNS | | | INTO HOT WATER SUPPLY AFTER THE DROP. PLEASE CLARIFY. | | | --THE COLD WATER SUPPLY IS SHOWN TO THE STORAGE TANK. | | | PLEASE EXPLAIN.--HOT & COLD INLETS TO THE STORAGE | | | TANK? CLARIFY. SECTION 106.1.1.--A VACUUM RELIEF | | | VALVE IS REQUIRED FOR ALL BOTTOM FED WATER HEATERS. | | | SECTION 504.2.--THE FLOOR DRAIN IS NOT AN APPROVED | | | INDIRECT WASTE RECEPTOR. A FLOOR SINK OR A HUB DRAIN IS | | | REQUIRED. SECTIONS 802.3 & 802.3.2. | | | ****RESPONSE NOTED, BUT NO CLARIFICATION OF HOW THE | | | COLD WATER SUPPLY TURNS INTO THE HOT WATER SUPPLY. | | | | | | 39. OK | | | | | | | | | **********NEW COMMENT********** | | | | | | 1B. INFORMATIONAL: THE CERTIFICATIONS AND WELDING | | | PROCEDURE WILL BE REQUIRED AT THE TIME OF GAS PERMIT | | | APPLICATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | ****NO RESPONSE FOR THE REQUEST TO SUBMIT ONE SET OF | | | OLD/VOID SHEETS TO HELP EXPEDITE THE REVIEW PROCESS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-23 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-11 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2007-08-23 11:59:28 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | CITY WPB MUNICIPAL CODE | | | | | | 1. SHT G-001 OCCUPANCY DATA. PLEASE CLARIFY SQUARE | | | FOOTAGE FOR THE BUSINESS AND STORAGE OCCUPANCY. PER | | | DATA INDICATED IT SEEM THAT THE AREA FOR THE STORAGE IS | | | APPROXIMATLY TWICE THAT OF THE BUSINESS AREA. LOOKING | | | AT THE FLOOR PLAN THIS DOES NOT SEEM TO BE THE CASE. | | | PLEASE INDICATE EACH AREA TO BE INDICATED AS STORAGE | | | WITH THE SQUARE FOOTAGE FOR EACH AREA. ALSO INDICATE | | | EACH AREA TO BE BUSINESS OCCUPANCY AND SHOW SQUARE | | | FOOTAGE OF EACH AREA. SECTION 106.3.5.1.1(2). THIS WILL | | | HELP VERIFY OCCUPANCY DATA. | | | | | | 2. SHT G-001 BUILDING DATA INDICATES 37,772SF, BUT THE | | | APPLICATION INDICATES 27,308SF. PLEASE CORRELATE | | | INFORMATION ON PLANS WITH THE APPLICATION. SECTION | | | 106.1.1. | | | | | | 3. CIVIL DRAWINGS. THE ADDRESS FOR THE ENGINEERING | | | CONPANY IN THE TITLE BLOCK DOES NOT REFLECT THE ADDRESS | | | INDICATED ON THE FLORIDA STATE DBPR WEBSITE. PLEASE | | | UPDATE THE WEBSITE OR THE TITLE BLOCKS PRIOR TO | | | RESUBMITTING. ALSO THE ENGINEER SHALL LEGIBLY INDICATE | | | HER ADDRESS IN THE TITLE BLOCK.FAC 61G15-23.002(2) & | | | FS 471.025. PLEASE INDICATE ENGINEER'S ADDRESS. | | | | | | 4. SHTS L-1 THRU L-6 THEFIRM LICENSE NUMBER, | | | (CERTIFICATE OF AUTHORIZATION), IS REQUIRED IN THE | | | TITLE BLOCK PER FAC 61G1-16.004(2) & FS 481.219, | | | 481.2055. PLEASE SHOW FIRM LICENSE NUMBER IN TITLE | | | BLOCK. | | | | | | 5. ALL ARCHITECTURAL SHEETS. THE SIGNATURE IS REQUIRED | | | FOR THE ARCHITECT. IT APPEARS THAT INITIALS HAVE BEEN | | | USED. IF THIS IS INDEED THE LEGAL SIGNATURE OF THE | | | ARCHITECT, THEN A SIGNED, SEALED, DATED, NOTORIZED | | | LETTER INDICATING THE LEGAL SIGNATURE OF THE ARCHITECT | | | SHALL BE SUBMITTED FOR OUR FILES. FAC 61G1-16.003, | | | 61G1-16.004(5) & FS 481.2055. | | | | | | 6. SHT A-104 DETAILS 1 THRU 4. SHOW THE 5' TURNING AREA | | | REQUIRED IN THE TOILET ROOMS PER SECTION 11-4.22.3. | | | | | | 7. SHT A-104 DETAIL 4 SHOW THE CLEAR FLOOR SPACE FOR | | | ALL REQUIRED ACCESSIBLE FIXTURES PER SECTIONS | | | 11-4.16.2, 11-4.19.3 & 11-4.21.2.--A TURNING AREA | | | IS REQUIRED FOR THE SHOWER ROOMS PER SECTION 11-4.2.3. | | | PLEASE SHOW ON DETAIL.--DOORS SHALL NOT SWING INTO | | | THE CLEAR FLOOR SPACE REQUIRED FOR ANY FIXTURE. SECTION | | | 11-4.23.2. THIS WILL INCLUDE THE SHOWERS AND THE LAVS | | | OUTSIDE THE SHOWERS. | | | | | | 8. SHT A-104 DETAIL 4. SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | ___FOR W/C'S: | | | A. 11-4.16.5 FLUSH CONTROLS | | | ___FOR LAVS: | | | A. 11-4.19.2 CLEARANCES | | | B. 11-4.19.4 EXPOSED PIPES & SURFACES | | | C. 11-4.19.5 FAUCETS | | | ___FOR SHOWERS: | | | A. 11-4.21.2 SIZE & CLEARANCES | | | B. 11-4.21.3 SEAT | | | C. 11-4.21.4 GRAB BARS | | | D. 11-4.21.5 CONTROLS | | | E. 11-4.21.6 SHOWER UNIT | | | F. 11-4.21.7 CURBS | | | | | | 9. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING | | | FOUNTAINS. SHOW COMPLIANCE WITH THE SECTION 11-4.15 AND | | | ALL SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A) | | | PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | | | | 10. SHT A-300 SUBMIT CALCULATIONS FOR PRIMARY & | | | SECONDARY ROOF DRAINS PER SECTIONS 1106 & 1107 WITH ALL | | | SUBSECTIONS & TABLES. SHOW THE SQUARE FOOT AREA OF EACH | | | ROOF DRAIN WITH 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS AS WELL AS THE SQUARE FOOTAGE OF ALL | | | ROOFS THAT DRAIN ONTO EACH AREA FROM ABOVE ADDED IN THE | | | CALCULATIONS. | | | | | | 11. SHT A-300 LOWER ROOF ON THE WEST SIDE OF THE | | | BUILDING INDICATES R5 TYP FOR O.S. DETAIL R5 INDICATES | | | A PARAPET WALL. SECONDARY ROOF DRAIS REQUIRED PER | | | SECTION 1107.2. IS THE DRAIN SHOWN A SCUPPER DRAIN OR | | | AN OVERFLOW SCUPPER DRAIN? PLEASE CLARIFY AND INDICATE | | | SECONDARY DRAIN. SECTION 106.1.1. | | | | | | 12. SHT A-300 UPPER ROOF AT N.E. CORNER INDICATES R5 AS | | | AN O.S. PLEASE CLARIFY.--LOWER ROOF DRAINS ARE | | | INDICATED AS O.S., NOT PRIMARY SCUPPER DRAINS. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | | | | 13. SHT A-300 INDICATES R15 FOR THE SCUPPER WITH | | | DOWNSPOUT & O.S. R15 SHOWS NO COLLECTOR HEAD OR | | | DOWNSPOUT. ALSO SHEET A-400 SHOWS NO DOWNSPOUTS. PLEASE | | | CLARIFY AND INDICATE THE SIZE OF THE DOWNSPOUTS AND | | | SHOW COLLECTOR HEAD WITH DIMENSIONS. TABLES 1106.3 & | | | 1106.7.--ALSO INDICATE HOW THE PRIMARY DRAIN & O.S. | | | CAN BE AT THE ROOF LEVEL. SECTIONS 1503.4.2 & | | | 1503.4.3. | | | | | | 14. SHT A-709 DETAILS 79 & 81. SHOW COMPLIANCE WITH | | | SECTION 11-4.24 & ALL SUBSECTIONS. NOTE: FORWARD | | | APPROACH REQUIRED ON CLEAR FLOOR SPACE AND CABINET | | | DOORS ARE NOT APPROVED IN THE CLEAR FLOOR SPACE. | | | | | | 15. ALL PLUMBING, MECHANICAL, ELECTRICAL & FIRE | | | PROTECTION SHEETS. THE ENGINEER SHALL LEGIBLY INDICATE | | | THEIR ADDRESS. FAC 61G15-23.002(2) & FS 471.025. | | | | | | 16. SHT P0-1-1 IS INDICATED AS HVAC LEGEND, SCHEDULE & | | | GENERAL NOTES IN THE SHEET TITLE. PLEASE CHANGE | | | REFERENCE TO IDENTIFY INFORMATION ON SHEET. SECTION | | | 106.1.1. | | | | | | 17. SHT P0-101 THE MAXIMUM DISTANCE OF THE FIXTURE TRAP | | | FROM THE VENT SHALL COMPLY WITH TABLE 906.1. SOME FLOOR | | | DRAINS APPEAR TO EXCEED THE LIMIT, BUT NO PIPE/TRAP | | | SIZE IS INDICATED. PLEASE CHECK THE DISTANCE FROM THE | | | VENT AND INDICATE PIPE/TRAP SIZE. TABLE 709.1. | | | | | | 18. SHT P1-101. SUBMIT THE MANUF. SPECIFICATION SHEETS | | | FOR THE SN-1 FIXTURE INCLUDING INSTALLATION | | | INSTRUCTIONS. SECTION 106.1.2. | | | | | | 19. SHT P1-101 SUBMIT A DETAIL FOR THE CANINE | | | PRE-OP/POST-OP KENNELS. SHOW A DETAIL FOR THE WATER | | | BACKFLOW PROTECTION AND CONNECTION TO THE DOG BOWLS. | | | SECTION 608. SHOW THE CONNECTION TO THE TRENCH DRAINS | | | AND THE SN-1 FIXTURES. SECTION 106.1.2. (SN-1 FIXTURES | | | NOT SHOWN ON THE ISOMETRIC RISER DIAGRAM. CLARIFY). | | | | | | 20. SHT P1-103 SEPARATE GAS PERMIT IS REQUIRED. THE | | | FOLLOWING REQUIREMENTS SHALL BE SUBMITTED FOR GAS | | | REVIEW: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | | | | D. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | | | | E. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (NOT SHOWN FOR GB1 | | | UNITS). | | | | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | | | | G. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | | | H. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES | | | PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | 21. SHT P1-103 DETAIL (2) GB1(1300MBTH) NOT INDICATED | | | ON THE PLUMBING EQUIPMENT SCHEDULE ON SHT P5-101. | | | PLEASE IDENTIFY THESE FIXTURES. SECTION 106.1.2. | | | | | | 22. SHT P1-105 A RELIEF VENT, (GOOSE-NECK) FITTING | | | SHALL BE INSTALLED IN THE CONDENSATE DRAIN LINE AS IT | | | EXITS THE BUILDING. | | | | | | 23. SHT P2-101 WATER HAMMER ARRESTORS ARE REQUIRED ON | | | ALL QUICK CLOSING VALVES PER SECTION 604.9. (ICE | | | MAKERS, DISH WASHERS, WASH MACHINES ETC.). PLEASE SHOW | | | ON THE WATER ISOMETRIC RISER DIAGRAM. WHA'S TO BE | | | LOCATED NEAR THE FIXTURE, NOT IN THE CEILING. PDI-WH | | | 201. | | | | | | 24. SHT P2-101 2" WATER SUPPLY LINE DOES NOT CONNECT TO | | | THE WATER SUPPLY LINE IN THE CEILING ABOVE THE | | | VESTIBLUE FOR THE MEN'S LOCKER ROOM. (ALSO SEE SHT | | | P1-103). SECTION 106.1.1. PLEASE INDICATE WHERE THE 2" | | | CW CONNECTS. | | | | | | 25. SHT P2-101 PLEASE IDENTIFY THE FIXTURE THAT | | | CONNECTS TO THE COLD WATER SUPPLY LINE THEN INDICATES | | | HOT WATER LINE CONNECTING TO THE 3/8TH" STAINLESS STEEL | | | TUBING INDICATED AS A COLD WATER LINE. THIS IS ABOVE | | | ROOM #174. PLEASE CLARIFY SECTION 106.1.2. | | | | | | 26. SHT P2-101 SHOW ALL PIPE SIZES. SECTIONS 106.2.1 & | | | 604. | | | | | | 27. SHT P3-101 SHOW ALL PIPE SIZES AND INDICATED ON THE | | | SANITARY ISOMETRIC RISER DIAGRAM THE DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM. TABLES 709.1, 710.1(1) & | | | 710.1(2). | | | | | | 28. SHT P3-101 INDICATE HOW THE VENT CONNECTS TO THE | | | BRANCH LINE BEHIND THE W/C IN TOILET ROOM 183. SECTIONS | | | 905.3 & 905.4. (ALSO SEE SHT P1-101). | | | | | | 29. SHT P3-101 A TRAP AND A VENT ARE REQUIRED FOR THE | | | SINK IN ROOM 172. SECTIONS 901.2.1 & 1002.1. (ALSO SEE | | | SHT P1-101). | | | | | | 30. SHT P3-101 NOT ALL KENNELS SHOW A TD1. PLEASE | | | CLARIFY. (ALSO SEE SHT P1-101). SECTION 106.2.1. | | | | | | 31. SHT P3-101 TRAPS FOR TD1'S ON SANITARY RISER | | | ISOMETRIC DIAGRAM ARE NOT LEGIBLE. PLEASE CLARIFY HOW | | | THE TRAPS ARE TO BE CONNECTED TO THE BRANCH LINE. | | | SECTION 106.1.1. | | | | | | 32. SHT P3-101 NOTE "PROVIDE FUNNEL" FOR RESIDENTIAL | | | AREA CONDENSATE NOT APPROVED. CONDENSATE SHALL NOT | | | DRAIN INTO THE SANITARY SYSTEM. CONDENSATE SHALL DRAIN | | | SEPARATELY OUT OF THE BUILDING AND TERMINATE INTO THE | | | STORM, A CATCH BASIN, DRWELLL, OR PLANTED AREA A | | | MINIMUM 1 FOOT FROM THE STRUCTURAL WALL.MUNICIPAL | | | CODE ARTICLE III SECTION 90-125(5). PLEASE INDICATE HOW | | | CONDENSATE TO BE DRAINED FROM RESIDENTIAL AREA. SECTION | | | 106.1.2. | | | | | | 33. SHT P3-101 THE WASH MACHINES REQUIRE A STANDPIPE, | | | MINIMUM 18" AND A CLEANOUT, MINIMUM 4FT ABOVE THE | | | FLOOR. SECTIONS 708.9 & 802.4. PLEASE SHOW ON THE SANT. | | | RISER DIAGRAM. | | | | | | 34. SHT P3-101 CLEANOUTS REQUIRED PER SECTIONS 708.3.1 | | | & 708.3.5. PLEASE INDICATE ON THE SANT. RISER DIAGRAM & | | | ON THE FLOOR PLANS SHTS P1-101, P1-102 & P1-103. | | | | | | 35. SUBMIT STORM RISER DIAGRAMS . SHOW ALL PIPE SIZES & | | | INDICATE SQUARE FOOTAGE AS IT ACCUMULATES IN THE | | | SYSTEM. ALSO SHOW ALL CLEANOUTS REQUIRED BY SECTION | | | 1101.8. (ALSO SHOW CLEANOUTS ON SHT P1-105). | | | 106.3.5.1.3(7)(13). | | | | | | 36. SUBMIT A CONDENSATE RISER DIAGRAM. INDICATE ALL | | | PIPE SIZES AND SHOW PIPES FROM A/C UNIT THRU | | | TERMINATION. INDICATE MATERIAL FOR CONDENSATE PIPING. | | | SECTION 106.3.5.1.3(13). | | | | | | 37. SHT P4-1-1 WATER HAMMER ARRESTOR DETAIL. THE | | | LOCATION OF THE WATER HAMMER ARRESTORS SHALL BE NEAR | | | THE FIXTURE, IN AN "EFFECTIVE RANGE" NOT IN THE CEILING | | | AS SHOWN. PDI-WH 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS. | | | | | | 38. SHT P4-101 PACKAGED WATER HEATER-STORAGE | | | RECIRCULATION SYSTEM GWH-1. THE COLD WATER SUPPLY TURNS | | | INTO HOT WATER SUPPLY AFTER THE DROP. PLEASE CLARIFY. | | | --THE COLD WATER SUPPLY IS SHOWN TO THE STORAGE TANK. | | | PLEASE EXPLAIN.--HOT & COLD INLETS TO THE STORAGE | | | TANK? CLARIFY. SECTION 106.1.1.--A VACUUM RELIEF | | | VALVE IS REQUIRED FOR ALL BOTTOM FED WATER HEATERS. | | | SECTION 504.2.--THE FLOOR DRAIN IS NOT AN APPROVED | | | INDIRECT WASTE RECEPTOR. A FLOOR SINK OR A HUB DRAIN IS | | | REQUIRED. SECTIONS 802.3 & 802.3.2. | | | | | | 39. SHT P4-101 GAS WATER HEATER FLUE DETAIL SHOWS 2 | | | VENTS. IS THE CAT 1, CLASS B VENT TO THE WALL A DIRECT | | | VENT? PLEASE CLARIFY. (IF DIRECT VENT, CLASS B NOT | | | REQUIRED). SECTION 106.1.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. RESUBMIT | | | MARKED UP PLUMBING SHEETS TO ALLSO HELP EXPEDITE PLAN | | | REVIEW. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
11 |
Status |
P |
Date |
2009-10-21 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-10-21 |
Time |
11:05 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2009-10-21 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2009-10-21 11:05:46 | PASSED | | | | | | PLANS FROM 9/23/09 MINOR AMENDMENT SUBMITTED WITH THIS | | | REVISION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
10 |
Status |
F |
Date |
2009-09-16 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-09-16 |
Time |
17:13 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2009-09-16 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2009-09-16 17:22:50 | FAILED | | | | | | 1) STAFF IS PROCESSING A MINOR AMENDMENT TO THE SITE, | | | LANDSCAPE AND CIVIL PLANS THAT IS NOT REFLECTED | | | CORRECTLY ON SHEETS A-010 AND A-012 THAT HAVE BEEN | | | SUBMITTED WITH THIS REVISION. | | | | | | 2) NO REVISED LANDSCAPE AND CIVIL PLANS WERE SUBMITTED | | | WITH THIS REVISION. THE LATEST STAMPED CIVIL AND | | | LANDSCAPE PLANS DO NOT MATCH THOSE INCLUDED WITH THE | | | MINOR AMENDMENT NOR DO THEY MATCH THE SITE PLANS | | | SUBMITTED WITH THIS REVISION. | | | | | | 3) THIS PERMIT IS FOR PHASE I REVISIONS, YET IT SHOWS | | | CHANGES THAT ARE TO OCCUR IN PHASE II, BUT IT DOES NOT | | | SHOW WHAT PHASE I WILL LOOK LIKE PRIOR TO THE WORK | | | COMMENCING ON PHASE II. | | | | | | CONTACT ERIC SCHNEIDER @ (822-1446). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
9 |
Status |
F |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-07-14 |
Time |
13:16 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2009-07-14 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2009-07-14 13:18:24 | FAILED IN PART REVISION SUBMITTED ON JUNE 25, 2009. | | | | | | THE FOLLOWING SHEET IS NOT PASSED: | | | | | | L-1 | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
8 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-07-14 |
Time |
13:15 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2009-07-14 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2009-07-14 13:15:08 | PASSED IN PART REVISION SUBMITTED ON JUNE 25, 2009. | | | | | | THE FOLLOWING SHEETS ARE PASSED: | | | | | | C 2.1 | | | C 3.1 | | | C 5.1 | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
7 |
Status |
F |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-06-09 |
Time |
11:52 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2009-06-09 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2009-06-09 11:56:49 | FAILED IN PART REVISION SUBMITTED 6-3-09 | | | | | | 1) THE FOLLOWING SHEETS SUBMITTED AS PART OF THE | | | REVISION HAVE FAILED AS THEY DO NOT MATCH THE APPROVED | | | SITE AND LANDSCAPE PLANS - LOCATION OF TRANSFORMER PAD, | | | FENCE LOCATION AND WIDTH OF THE SIDEWALK ADJACENT TO | | | THE GENERATOR PAD: | | | | | | C 2.1 | | | C 3.1 | | | C 5.1 | | | | | | 2) SHEET L-1 SHOWING THE LATEST REVISIONS IS REQUIRED. | | | THE EXISTING L-1 IS VOIDED BASED ON THE REVISIONS TO | | | THE SITE. PLEASE VOID THE FIELD SET. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-06-09 |
Time |
11:25 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2009-06-09 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2009-06-09 11:52:21 | PASSED IN PART REVISION SUBMITTED 6-3-09 | | | | | | THE FOLLOWING SHEETS SUBMITTED AS PART OF THE REVISION | | | HAVE PASSED: | | | | | | A-010 | | | A-012 | | | A-100A | | | A-400 | | | L-2 | | | L-3 | | | L-4 | | | L-8 | | | L-9 | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2008-12-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-12-19 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-12-19 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2008-12-19 16:43:46 | FAILED | | | | | | 1) THE CHANGES TO THE SITE AND LANDSCAPE PLANS AND | | | ELEVATIONS REQUIRE APPROVAL BY THE PLANNING AND ZONING | | | DEPARTMENT THROUGH THE MINOR AMENDMENT PROCESS. | | | | | | 2) NO LANDSCAPE PLAN SHOWING THE CHANGES WAS SUBMITTED | | | WITH THE PERMIT. | | | | | | 3) EARLIER DISCUSSIONS WITH PLANNING STAFF INDICATED | | | THAT A TRANSFORMER WOULD BE LOCATED AT THE SOUTHERN END | | | OF THE WESTERN PARKING. IF A TRANSFORMER HAS BEEN | | | INSTALLED, IT SHALL BE SHOWN ON ALL PLANS. | | | | | | 4) THE NEW PARKING SPACE HAS CAUSED THE FIRE HYDRANT TO | | | CONFLICT WITH THE REQUIRED TERMINAL ISLAND TREE. THE | | | HYDRANT AND REQUIRED TREE CONFLICT NEEDS TO BE | | | RESOLVED. | | | | | | 5) THE NEW SECTIONS OF WALL THAT SCREEN THE GENERATOR | | | AND CHILLERS REQUIRE HEDGES ON THE EXTERIOR TO ACT AS | | | SCREENING OF THE WALLS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-08-06 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-08-06 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-05-27 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-05-27 |
Time |
18:00 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-05-27 |
Time |
18:00 |
Sent To |
|
|
| Notes |
| 2008-05-27 18:01:35 | PASSED | | | | | | NOTES: | | | | | | THE SIGNAGE AND FENCE/GATES SHALL BE UNDER SEPARATE | | | PERMITS. | | | | | | ALL RIGHT-OF-WAY AREAS ADJACENT TO THE SITE SHALL BE | | | SODDED, IRRIGATED AND MAINTAINED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-02-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2008-02-19 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2008-02-19 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2008-02-19 15:37:00 | FAILED | | | | | | PLEASE RESPOND IN WRITING TO COMMENTS: | | | | | | 1) THE FOLLOWING ITEMS FROM ORDINANCE NO. 4901 HAVE NOT | | | BEEN ADDRESSED: | | | | | | A. ALL UTILITIES ON THE PORTION OF THE CSPD THAT WILL | | | HOUSE THE GRACE PAVILION SHALL BE BURIED UNDERGROUND. | | | | | | B. THE EXISTING CHAIN LINK FENCE ON THE GRACE PAVILION | | | SITE AND ALONG THE ENTIRE MILITARY TRAIL FRONTAGE SHALL | | | BE REPLACED BY EITHER VINYL COATED CHAIN LINK OR OTHER | | | DECORATIVE FENCE, SUBJECT TO PLANNING AND ZONING | | | DEPARTMENT APPROVAL. | | | | | | D. PRIOR TO THE ISSUANCE OF ANY PERMIT, THE FOLLOWING | | | SHALL OCCUR: | | | | | | I. A TREE ALTERATION PERMIT SHALL BE OBTAINED BY THE | | | DEVELOPER FROM THE CITY?S PLANNING AND ZONING | | | DEPARTMENT. | | | | | | II. RECORD A PLAT FOR ALL OF THE PARCELS WITHIN THE | | | ANIMAL RESCUE LEAGUE COMMUNITY SERVICE PLANNED | | | DEVELOPMENT. | | | | | | III. ABANDON THE EASEMENTS THAT CONFLICT WITH THE | | | BUILDING, AS WELL AS ANY OTHER UNNECESSARY EASEMENTS. | | | | | | 2) SHEETS C4.1 AND A-011 HAVE DIFFERENT DUMPSTER | | | DETAILS.THE ONE ON C4.1 MEETS CITY CODE, BUT DOES NOT | | | INCLUDE THE RECYCLE AREA.THE ONE ON A-001 HAS THE | | | RECYCLE AREA AND LOOKS LIKE THE ONE ON THE SITE PLAN, | | | BUT DOES NOT MEET CITY STANDARDS.PLEASE REVISE | | | ACCORDINGLY. | | | | | | 3) ALL SIGNAGE, TO INCLUDE THE TEMPORARY CONSTRUCTION | | | SIGN SHALL BE UNDER SEPARATE PERMIT. | | | | | | 4) THE EASTERN PARKING LOT AND DETENTION POND LAYERS | | | ARE NOT VISIBLE ON SHEET A-010. | | | | | | 5) IRRIGATION PLANS ARE REQUIRED. | | | | | | CONTACT ERIC SCHNEIDER@ (561) 822-1435. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-07-12 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-07-12 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2007-07-12 15:49:42 | FAILED | | | | | | THIS PROJECTS REQUIRES ZONING APPROVAL PRIOR TO ANY | | | BUILDING PERMIT APPROVAL.IF THE OFFICE BUILDING IS TO | | | OPERATE AS A SEPARATE ENTITY FROM THE REMAINDER OF THE | | | ARL, THEN SHALL BE APPROVED AS A FORMAL SITE PLAN | | | REVIEW.IF IT IS TO OPERATE AS A PART OF THE MAIN | | | CAMPUS, THEN IT WILL NEED TO HAVE A SITE PLAN APPROVED | | | BY THE CITY COMMISSION. | | | | | | CONTACT ERIC SCHNEIDER @ (561) |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |