Plan Review Stops For Permit 07060690
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-24 Cont ID  
Sent By kconrad Date 2007-07-24 Time 18:29 Rev Time 0.00
Received By kconrad Date 2007-07-24 Time 16:16 Sent To I
Notes
2007-07-24 18:28:25PROJECT: 5301 SOUTH DIXIE HIGHWAY
  
 PROJECT DESCRIPTION: STRUCTURAL REINFORCEMENT OF
 EXISTING STRUCTURAL FRAMING
  
 CODE REVIEW:2004 FLORIDA EXISTING BUILDING CODE
 W/2006 REVISIONS
 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONSCITY OF
 WEST PALM BEACH/ FLORIDA BUILDING CODE/ADMINISTRATION
 AMENDMENTS, CHAPTER 1, 2004 EDITION
  
 STATUS: DENIED
  
  
 COMMENTS:
  
  
 1) REQUIRE A NOTICE OF COMMENCEMENT AS PER THE
 FOLLOWING:
  
 FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
  
 2) PLEASE DESIGNATE LEVEL OF ALTERATION AS PER THE
 FOLLOWING:
  
 301.5
 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE OR A
 COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
  
 3) INDICATE OCCUPANCY AND USE:
  
 301.4OCCUPANCY AND USE.
 WHEN DETERMINING THE APPROPRIATE APPLICATION OF THE
 REFERENCED SECTIONS OF THIS CODE, THE OCCUPANCY AND USE
 OF A BUILDING SHALL BE DETERMINED IN ACCORDANCE WITH
 CHAPTER 3 OF THEFLORIDA BUILDING CODE,
 BUILDING.
  
 4) AS PER THE EXISTING BUILDING CODE, THE FOLLOWING
 SHALL APPLY:
  
 407.3.1NEW STRUCTURAL FRAME MEMBERS.
 NEW STRUCTURAL FRAME MEMBERS USED IN THE REPAIR OF
 DAMAGED BUILDINGS, INCLUDING ANCHORAGE AND CONNECTIONS,
 SHALL COMPLY WITH THE FLORIDA BUILDING CODE, BUILDING.
  
 5) PLEASE COMPLY WITH THE FOLLOWING:
  
 2101.3 CONSTRUCTION DOCUMENTS.
 THE CONSTRUCTION DOCUMENTS SHALL SHOW ALL OF THE
 ITEMS REQUIRED BY THIS CODE INCLUDING THE FOLLOWING:
 1.SPECIFIED SIZE, GRADE, TYPE AND LOCATION OF
 REINFORCEMENT, ANCHORS AND WALL TIES.
  
 6) PLEASE SUBMIT A ROOF FRAMING PLAN. INDICATE THE
 CONTINUOUS LATERAL BRACING:
  
 2319.17.2.1.8
 ALL TRUSSES SHALL BE PROPERLY BRACED TO ACT AS A
 SYSTEM. SUCH BRACING SHALL BE INCLUDED AS PART OF THE
 DESIGN DOCUMENT.
  
 7)PLEASE SHOW THE BUILDING ELEVATIONS AND INDICATE
 THE ROOF PITCH.
  
 8)INDICATE SPECIES AND GRADE OF NEW STRUCTURAL LUMBER
 TO BE USED.
  
 9)PLEASE SPECIFY GRADE AND LENGTH OF ANCHOR BOLTS.
  
 10) PLEASE SHOW THE DIMENSIONS OF THE EXISTING
 FOUNDATION PADS.
  
 11) PLEASE SUBMIT STRUCTURAL CALCULATIONS.
  
 12) SUBMIT EPOXY SPECIFICATIONS.
  
 13) PLEASE PROVIDE GROUT AND MORTAR SPECIFICATIONS.
  
 14) SHOW ALL ACCESSIBILITY DIMENSIONS FOR THE BATHROOMS
 TO BE ADDED.
  
 15) THE INDICATED CONSTRUCTION VALUATION APPEARS TO BE
 LOW. PLEASE PROVIDE SUPPORTING DATA.
  
  
 PLAN REVIEW: KEN CONRAD
 PHONE: 561.805.6666
 E-MAIL: [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-07-26 Cont ID  
Sent By mawillia Date 2007-07-26 Time 22:20 Rev Time 0.00
Received By mawillia Date 2007-07-26 Time 22:01 Sent To  
Notes
2007-07-26 22:20:26*****DENIED*****
  
  
 1. WHAT IS THE OCCUPANCY TYPE OF THIS STRUCTURE.
  
 2.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE
 REFERENCED.
  
 3.STUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 4.COMBUSTIBLE WASTE MATERIALS AND DEBRIS IN OR AROUND
 THE STRUCTURE SHALL BE REMOVED FROM THE SITE AT NTHE
 END OF EACH SHIFT OR MORE FREQUENTLY AS NECESSARY FOR
 SAFE OPERATION.
  
 5.THE SCOPE OF WORK SHALL NOT INTERFERE OR HINDER
 EMERGENCY RESPONSE ACCESS TO THE SAID PROPERTY OR
 VICINITY THEREOF (INCLUDING STREETS, ALLEYS, FIRE
 LANES).
  
 6.ON THE APPROPIATE EXTERIOR ELEVATION WHICH FRONTS
 SOUTH DIXIE HIGHWAY, SHOW/DISPLAY THE NUMERICAL ADDRESS
 ON THE BUILDING.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-26 Cont ID  
Sent By mawillia Date 2007-07-26 Time 22:01 Rev Time 0.00
Received By mawillia Date 2007-06-22 Time 14:05 Sent To  
Notes
2007-07-13 10:53:00TO "COMM' BD#25
2007-06-22 14:05:21TO "P" BOX

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-07-10 Cont ID  
Sent By mperson Date 2007-07-11 Time 15:46 Rev Time 1.25
Received By mperson Date 2007-07-10 Time 15:46 Sent To E
Notes
2007-07-10 17:01:47DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
 ** FBC-2004 CHAPTER 11.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PLEASE INDICATE ON THE FLOOR PLAN OF THE PROPOSED
 HANDICAP BATHROOMS THEIR ROOM DEMENSIONS ON THE
 RESUBMITTAL.
  
 2. AN UNOBSTRUCTED TURNING SPACE (FIVE FEET, 5')
 COMPLYING WITH SECTION 11-4.2.3 SHALL BE PROVIDED
 WITHIN AN ACCESSIBLE TOILET ROOM.
 NOTE: PLEASE INDICATE THIS TURNING SPACE ON THE
 RESUBMITTED BATHROOM FLOOR PLANS.
  
 3. DETAIL OF THE ACCESSIBLE LAVATORIES WITH THE
 FOLLOWING INFORMATION IS REQUIRED ON THE RESUBMITTAL.
 A} 11-4.19.2, HEIGHT AND CLEARENCES [SEE FIGURE 31]. B}
 11-4.19.3, CLEAR FLOOR SPACE [SEE FIGURE 32]. C}
 11-4.19.4, EXPOSED PIPES AND SURFACES. D} 11-4.19.5,
 FAUCETS.
  
 4. DETAIL OF THE ACCESSIBLE WATER CLOSETS WITH THE
 FOLLOWING INFORMATION IS REQUIRED ON THE RESUBMITTAL.
 A} 11-4.16.2, CLEAR FLOOR SPACE [SEE FIGURE 28]. B}
 11-4.16.4, GRAB BARS [SEE FIGURE 29]. C} 11-4.16.6
 DISPENSERS [SEE FIGURE 29(B)].
  
 5. DETAIL OF THE ACCESSIBLE DRINKING FOUNTAIN WITH THE
 FOLLOWING INFORMATION IS REQUIRED ON THE RESUBMITTAL.
 A} 11-4.15.2, SPOUT HEIGHT [SEE FIGURE 27(A)]. B}
 11-4.15.3, SPOUT LOCATION. C} 11-4.15.4, CONTROLS. D}
 11-4.15.5, CLEARENCES.
 NOTE: SHOW COMPLIANCE WITH 11-4.15.(10)(A) PROVISIONS
 FOR THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING.
  
 6. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.1.3
 PLUMBING THE FOLLOWING IS REQUIRED ON THE RESUBMITTAL.
 (3) WATER SUPPLY PIPING (RISER DIAGRAM INDICATING PIPE
 SIZES, VALVE LOCATIONS, WATER HAMMER ARRESTORS). (5)
 WATER HEATERS. (8) BACK FLOW PREVENTION. (10) LOCATION
 OF THE WATER SUPPLY LINE.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-18 Cont ID  
Sent By adavila Date 2007-07-18 Time 08:30 Rev Time 0.00
Received By adavila Date 2007-07-17 Time 08:30 Sent To  
Notes
2007-07-18 08:31:00PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PROVIDE A CURRENT SURVEY OF THE PROPERTY.
  
 2. PLEASE NOTE THAT IF THE BUILDING IS DEFINED AS A
 NONCONFORMING USE PER ARTICLE XVI OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS, THAN ALL REPAIRS AND
 ALTERATIONS SHALL BE SUBJECT TO THE REGULATIONS OF
 NONCONFORMING USES.
 A. PLEASE PROVIDE THE VALUE OF THE BUILDING/STRUCTURE.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.