| Plan Review Stops For Permit 07060613 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-07-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-06-20 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2007-06-19 10:25:10 | COPY OF APPLICATION TO LILI.PER JIM WITMER,ADDRESS | | | STOP NEEDS TO BE ADDED AS THERE ARE GOING TO BE 2 | | | BATHROOM STRUCTURES AT 2 DIFFERENT LOCATIONS ON THE | | | GOLF COURSE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-10-26 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-10-26 |
Time |
06:33 |
Sent To |
PC |
|
| Notes |
| 2007-10-26 13:46:11 | TO SPALMER TO TRANSFER FEES FROM PERMIT #07060613TO | | | PERMIT #07100708 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-10-20 |
Time |
07:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-10-19 |
Time |
18:20 |
Sent To |
E |
|
| Notes |
| 2007-10-19 18:58:12 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07060613 | | | ADD: 2300 PRESIDENTIAL WAY | | | CONT: GRUBER HALL CORP INC. | | | TEL: (561)697-3401 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 3RD 10/19-20/07 | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)) 106.3.3* PRODUCT APPROVALS- 2004. THOSE PRODUCTS | | | THAT ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. PROVIDE | | | PRODUCT APPROVALS FOR ALL ROOFING MATERIALS/ BAHAMA | | | SHUTTERS. **INDICATE WHICH ITEMS ARE RELEVANT TO THE | | | INSTALLATION OF THE DOOR FROM THE FLEMING STEEL DOOR | | | PACKAGE. | | | | | | ROOFING; ONLY CHECKED ITEMS APPLY | | | ____1.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY: | | | MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / AREA OF | | | EACH ROOF TYPE | | | ***NOTE*** | | | **FBC 1507.10.1 BUILT-UP ROOFS SHALL HAVE A DESIGN | | | SLOPE OF A MINIMUM OF ? VERTICAL IN 12 HORIZONTAL FOR | | | DRAINAGE, COAL-TAR BUILT-UP ROOFS SHALL A MINIMUM SLOPE | | | LF 1/8 VERTICAL IN 12 HORIZONTAL. THE INFORMATION | | | PROVIDED STATE A ?0? SLOPE.** | | | | | | ____2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | _XX_ 3.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. FOR | | | THE ROOF TILES INDICATE WHICH FASTEN METHOD WILL BE | | | USED. | | | _XX_4.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | _XX5.)OK | | | | | | _XX 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS | | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | | CONSULTANT REQUIRED FOR ENHANCED FASTENING.**PROVIDE | | | THE RAS 117 CALCULATIONS TO MEET THE ENHANCED FASTENER | | | DENSITIES FOR THE FLAT ROOF**. | | | | | | **NOTE** PAGE 16 OF THE PRODUCT APPROVAL INDICATE THE | | | SPACING OF THE NAILS AND TIN CAPS AT 9 INCHES ON CENTER | | | IN TWO STAGGERED ROWS TO ACHIEVE -52.5 PSF. THE | | | INFORMATION SUBMITTED FOR THE ENHANCE FASTENING SHOW | | | THE SPACING OF THE NAILS AT 12 INCHES ON CENTER FOR | | | EACH ZONE AND THE PRESSURES INCREASES FORM -49.2 PSF IN | | | ZONE 1 TO -82.6 PSF IN ZONE 2 AND-124.3 PSF IN ZONE | | | 3. IF THE SPACE IS INCREASED FROM 9 INCHES TO 12 INCHES | | | HOW IS IT POSSIBLE TO ACHIEVE HIGHER PRESSURES?THE | | | PRODUCT APPROVAL SHALL BE INCLUDED IN THE CALCULATIONS | | | OF THE ENHANCED FASTENING.THE PRODUCT APPROVAL ALSO | | | STATES THAT THE CALCULATIONS SHALL BE IN COMPLIANCE | | | WITH RAS 117 NOT RAS 150.THE INFORMATION PROVIDED IS | | | NON-COMPLIANT. | | | | | | 3)OK | | | | | | 4)2303.4.1 TRUSS DESIGN DRAWINGS. | | | TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL AND SHALL BE PROVIDED TO | | | THE BUILDING OFFICIAL AND APPROVED PRIOR TO | | | INSTALLATION. SUBMIT THE FLAT AND HIP ROOF INFORMATION. | | | *****NOTED***** | | | | | | **NOTE** A SEPARATE PERMIT IS REQUIRED FOR EACH | | | STRUCTURE LOCATED AT DIFFERENT LOCATIONS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-26 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-09-26 |
Time |
06:24 |
Sent To |
|
|
| Notes |
| 2007-09-26 11:31:25 | BUILDING PLAN REVIEW | | | PERMIT: 07060613 | | | ADD: 2300 PRESIDENTIAL WAY | | | CONT: GRUBER HALL CORP INC. | | | TEL: (561)697-3401 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)) 106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. PROVIDE PRODUCT APPROVALS FOR | | | ALL ROOFING MATERIALS/ EXTERIOR DOORS/PRE-CAST | | | LINTEL/BAHAMA SHUTTERS AND THE ROLING STEEL DOOR. | | | **THE PRODUCT APPROVAL FOR THE PRE-CAST LINTEL IS | | | MISSING FROM THE PACKAGE.** | | | | | | ROOFING ; ONLY CHECKED ITEMS APPLY | | | ____1.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED | | | POLICY:MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / | | | AREA OF EACH ROOF TYPE | | | | | | ____2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | _XX_ 3.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. FOR | | | THE ROOF TILES INDICATE WHICH FASTEN METHOD WILL BE | | | USED. | | | | | | _XX_4.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | | | _XX5.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | | METHOD OF ATTACHMENT YOU ARE USING. **ON PAGE #4 OR #5 | | | OF THE ROOF TILE PRODUCT APPROVAL CIRCLE WHICH ITEM | | | WILL BE USED**. | | | | | | _XX 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS | | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | | CONSULTANT REQUIRED FOR ENHANCED FASTENING.**PROVIDE | | | THE RAS 117 CALCULATIONS TO MEET THE ENHANCED FASTENER | | | DENSITIES FOR THE FLAT ROOF**. | | | | | | 3)OK | | | | | | 4)2303.4.1 TRUSS DESIGN DRAWINGS. | | | TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL AND SHALL BE PROVIDED TO | | | THE BUILDING OFFICIAL AND APPROVED PRIOR TO | | | INSTALLATION. SUBMIT THE FLAT AND HIP ROOF | | | INFORMATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-18 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-17 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2007-07-17 12:58:26 | BUILDING PLAN REVIEW | | | PERMIT: 07060613 | | | ADD: 2300 PRESIDENTIAL WAY | | | CONT: GRUBER HALL CORP INC. | | | TEL: (561)697-3401 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST. | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)) 106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. PROVIDE PRODUCT APPROVALS FOR | | | ALL ROOFING MATERIALS/ EXTERIOR DOORS/PRE-CAST | | | LINTEL/BAHAMA SHUTTERS AND THE ROLING STEEL DOOR. | | | | | | ROOFING ; ONLY CHECKED ITEMS APPLY | | | ____1.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED | | | POLICY:MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / | | | AREA OF EACH ROOF TYPE | | | | | | ____2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | ____3.)FOR THE FLAT DECK, SELECT THE APPROVED | | | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER | | | IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. | | | FOR THE ROOF TILES INDICATE WHICH FASTEN METHOD WILL | | | BE USED. | | | | | | ____4.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | | | ____5.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | | METHOD OF ATTACHMENT YOU ARE USING. | | | | | | ____ 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS | | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | | CONSULTANT REQUIRED FOR ENHANCED FASTENING. | | | | | | | | | 3)THE TITLE BLOCK IS MISSING THE FIRM LICENSE NUMBER. | | | SEE FAC. 61G1-16.004. | | | | | | 4)2303.4.1 TRUSS DESIGN DRAWINGS. | | | TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL AND SHALL BE PROVIDED TO | | | THE BUILDING OFFICIAL AND APPROVED PRIOR TO | | | INSTALLATION. SUBMIT THE FLAT AND HIP ROOF | | | INFORMATION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-10-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-29 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-29 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-20 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-20 |
Time |
08:21 |
Sent To |
B |
|
| Notes |
| 2007-10-20 08:23:30 | | | | ** PLANS WILL REMAIN IN FAILED STATUS UNTIL THE PERMITS | | | AND PLANS ARE DETERMINED. | | | IT IS STILL THE UNDERSTANDING AS PREVIOUSLY MENTIONED | | | THAT TWO PERMITS AND TWO SETS OF PLANS ARE REQUIRED. | | | THIS WILL BE GONE OVER WITH BUILDING OFFICIAL. | | | ELECTRICAL PLANS ARE ALREADY STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-18 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-18 |
Time |
14:08 |
Sent To |
I |
|
| Notes |
| 2007-09-18 14:26:04 | ** NOTES. | | | | | | 1) NOTE: PLEASE SEEAS PREVIOUSLY STATED THIS SHOULD | | | BE TWO SEPARATE PERMITS AS THESE ARE TWO SEPARATE | | | STRUCTURES, IN TWO SEPARATE LOCATIONS.,TWO SEPARATE | | | ELECTRICAL SERVICES ETC. | | | INSPECTIONS ETC? | | | | | | THIS WILL REMAIN IN A FAILED STATUS UNTIL THIS IS | | | CONFIRMED. ELECTRICAL SHEETS ARE STAMPED AS OK, HOWEVER | | | STILL MAY NEED ADDITIONAL PLANS. | | 2007-09-18 14:09:42 | REMOVED FROM INCOMING DUE TO DATED ORDER OF ELECTRICAL | | | REVIEW. | | | WILL RETURN TO IMCOMING WATING FOR COMM BOARD ONCE | | | REVIEW IS DONE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-02 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-02 |
Time |
15:38 |
Sent To |
I |
|
| Notes |
| 2007-07-02 16:52:55 | 2007-07-02 16:52:55 | | | | | | *** UNSAT *** | | | | | | | | | ** PLEASE KNOW THERE MAY BE NEW COMMENTS ONCE | | | ADDITIONAL INFORMATION IS SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE THE SUBMITTED DOCUMENTS REQUIRE THE | | | CODES TO BE STATED ON PLANS. PLEASE SEE THE FOLLOWING | | | ARE REQUIRED FOR ELECTRICAL AND OTHERS WILL BE REQUIRED | | | FOR OTHER TRADES. PLEASE KNOW AS OF DECEMBER 8TH, 2006 | | | THE STATE ADOPTED THE 2006 REVISIONS TO THE 2004 FBC | | | AND THE 2005 NFPA-70. PLEASE SEE THE PLANS DENOTE THE | | | 2005 REVISIONS. | | | PLEASE LIST THE FOLLOWING: | | | 2004 FBC W/ 2006 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE NOTES FROM BUILDING AND ADDRESSING | | | REVIEWER(S) AS EACH BUILDING MAY REQUIRE SEPARATE | | | PERMIT APPLICATIONS. PLEASE ALSO SEE THE ADDRESSING OF | | | EACH WILL BE CHANGED FOR EXTENSIONS UNDER THE COMMON | | | AREA ADDRESS. | | | PLEASE ADJUST TITLE BLOCKS WITH ANY NEW ADDRESS AT | | | DETERMINED BY THIS OFFICE. | | | PLEASE KNOW, IF EACH BUILDING IS UNDER SEPARATE | | | PERMITS, TWO SETS OF PLANS WILL BE REQUIRED FOR EACH. | | | FAC 61G1-16.004 | | | FBC 106.1 | | | | | | 3) NOTE: PLEASE SEE MISSING INFORMATION ON TITLE BLOCKS | | | FOR ARCHITECTURAL FIRM AS REQUIRED PER FAC 61G1-16.004, | | | FS 481.219. | | | PLEASE SEE MISSING THE CERTIFICATE OF AUTHORIZATION | | | NUMBER ALSO KNOWN AS THE FIRM LICENSE NUMBER. | | | | | | 4) NOTE: PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS ARE | | | NOT OF SUFFICIENT SIZE PER 310.16, 240.4. | | | PLEASE SEE MINIMUM SIZE REQUIRED FOR THE 100AMP MAIN AS | | | SHOWN. | | | | | | 5) NOTE: PLEASE SEE RISER INDICATES AN *EQUIPMENT | | | GROUNDING CONDUCTOR* FROM FPL BEFORE THE FIRST MEANS OF | | | DISCONNECT WHICH IS NOT PERMITTED. PLEASE SEE 250.6 AND | | | 250.24. | | | THE EQUIPMENT GROUNDING CONDUCTOR IS ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISCONNECT. | | | | | | 6) NOTE: PLEASE SEE 2005 NEC AS OUTDOOR RECEPTACLES IN | | | 210.8B4 REQUIRE GFI PROTECTION EVEN FOR DEDICATE | | | CIRCUITS/DEVICES/APPLIANCES. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-07-02 15:36:12 | 2007-07-02 15:36:12 | | | PLANS REMOVED FROM INCOMING. PLANS WILL RETURN TO | | | INCOMING WAITING FOR COMM BOARD ONCE ELECTRICAL REVIEW | | | IS DONE. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-08-03 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-08-03 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-07-30 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-07-30 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2007-07-30 11:03:24 | PLANS APPROVED AND WILL BE STAMPED WHEN RETURNED FOR | | | OTHER CORRECTIONS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-11 |
Time |
11:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-11 |
Time |
11:44 |
Sent To |
|
|
| Notes |
| 2007-10-16 18:00:32 | | | | SENT TO JOHN ROACH FOR REVIEW.NEEDS ZONING AND | | | BUILDING ONLY BECAUSE ELECTRICAL AND PLUMBING EACH HAVE | | | THE SAME PROCEDURAL COMMENT. | | 2007-10-11 11:45:16 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-27 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-27 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2007-09-20 09:38:35 | TO "COMM" BD#63 | | 2007-09-14 08:17:23 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-08-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-21 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2007-07-09 14:11:28 | TO "COMM" BD#19 | | 2007-06-21 16:48:58 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-07-18 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-07-18 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2007-07-18 16:50:24 | MECHANICAL PERMIT REQUIRED FOR EXHAUST FANS. MECHANICAL | | | CONTRACTOR CAN SIGN ON TO THIS PERMIT AS A | | | SUBCONTRACTOR OR FILE A SEPARATE PERMIT APPLICATION | | | REFERENCING THIS PERMIT ONCE IT IS ISSUED. | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-07 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-07 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2007-12-07 09:42:03 | REVISION OK - 8-1/2" X 11" REVISION OF SHEET A-6. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-10-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-25 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-25 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-23 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-19 |
Time |
17:46 |
Sent To |
|
|
| Notes |
| 2007-10-23 07:11:51 | PLUMBING PLANS APPROVED AND STAMPED, BUT REVIEW STOP | | | SHALL REMAIN IN FAILED STATUS UNTIL THE ISSUE OF TWO | | | PERMITS IS RESOLVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-10-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-04 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-04 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2007-10-04 17:42:20 | PLUMBING PLANS APPROVED AND STAMPED, BUT REVIEW STOP | | | SHALL REMAIN IN FAILED STATUS UNTIL THE ISSUE OF TWO | | | PERMITS IS RESOLVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-17 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-17 |
Time |
08:21 |
Sent To |
|
|
| Notes |
| 2007-07-17 08:27:25 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL SHEETS. THE FIRM LICENSE NUMBER SHALL BE | | | INCLUDED IN THE TITLE BLOCK. FAC 61G1-16.002(2) & FS | | | 481.219, 481.2055.-TITLE BLOCK INDICATES A | | | CORPORATION (LC). | | | | | | 2. SUBMIT A WATER RISER DIAGRAM. SHOW ALL PIPE SIZES, | | | VALVES, AND WATER HAMMER ARRESTORS, (SEE PLUMBING | | | COMMENT #18). WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" NOT IN THE | | | CEILING PER PDI-WH 201 AND MANUF INSTALLATION | | | INSTRUCTIONS. 106.3.5.1.3(3)(10)(13). | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-10-19 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-10-19 |
Time |
15:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-09-20 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-09-20 |
Time |
17:44 |
Sent To |
|
|
| Notes |
| 2007-09-20 17:45:21 | ***FAILED*** | | | | | | 1) TWO (2) COPIES OF A CURRENT, ACCURATE SURVEY SHALL | | | BE PROVIDED SHOWING THE LOCATION OF THE PROPOSED | | | STRUCTURES.NO SURVEY WAS PROVIDED. | | | | | | 2) SURVEYS SHALL NOTE THE SETBACKS FROM THE NEAREST | | | PROPERTY LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-22 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-07-22 |
Time |
21:05 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-07-22 |
Time |
21:04 |
Sent To |
|
|
| Notes |
| 2007-07-22 21:06:43 | ***FAILED*** | | | | | | 1) TWO (2) COPIES OF A CURRENT, ACCURATE SURVEY SHALL | | | BE PROVIDED SHOWING THE LOCATION OF THE PROPOSED | | | STRUCTURES.NO SURVEY WAS PROVIDED. | | | | | | 2) SITE PLANS AND SURVEYS SHALL NOT THE SETBACKS FROM | | | THE NEAREST PROPERTY LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|