Plan Review Details - Permit 07060613
Plan Review Stops For Permit 07060613
Review Stop AD ADDRESSING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2007-07-16 Time   Rev Time 0.00
Received By lursu Date 2007-06-20 Time 08:38 Sent To  
Notes
2007-06-19 10:25:10COPY OF APPLICATION TO LILI.PER JIM WITMER,ADDRESS
 STOP NEEDS TO BE ADDED AS THERE ARE GOING TO BE 2
 BATHROOM STRUCTURES AT 2 DIFFERENT LOCATIONS ON THE
 GOLF COURSE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-10-26 Cont ID  
Sent By mjacobs Date 2007-10-26 Time 13:43 Rev Time 0.00
Received By mjacobs Date 2007-10-26 Time 06:33 Sent To PC
Notes
2007-10-26 13:46:11TO SPALMER TO TRANSFER FEES FROM PERMIT #07060613TO
 PERMIT #07100708

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-10-20 Cont ID  
Sent By mjacobs Date 2007-10-20 Time 07:05 Rev Time 0.00
Received By mjacobs Date 2007-10-19 Time 18:20 Sent To E
Notes
2007-10-19 18:58:12 
 BUILDING PLAN REVIEW
 PERMIT: 07060613
 ADD: 2300 PRESIDENTIAL WAY
 CONT: GRUBER HALL CORP INC.
 TEL: (561)697-3401
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 3RD 10/19-20/07
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)) 106.3.3* PRODUCT APPROVALS- 2004. THOSE PRODUCTS
 THAT ARE REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR
 TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. PROVIDE
 PRODUCT APPROVALS FOR ALL ROOFING MATERIALS/ BAHAMA
 SHUTTERS. **INDICATE WHICH ITEMS ARE RELEVANT TO THE
 INSTALLATION OF THE DOOR FROM THE FLEMING STEEL DOOR
 PACKAGE.
  
 ROOFING; ONLY CHECKED ITEMS APPLY
 ____1.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY:
 MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / AREA OF
 EACH ROOF TYPE
 ***NOTE***
 **FBC 1507.10.1 BUILT-UP ROOFS SHALL HAVE A DESIGN
 SLOPE OF A MINIMUM OF ? VERTICAL IN 12 HORIZONTAL FOR
 DRAINAGE, COAL-TAR BUILT-UP ROOFS SHALL A MINIMUM SLOPE
 LF 1/8 VERTICAL IN 12 HORIZONTAL. THE INFORMATION
 PROVIDED STATE A ?0? SLOPE.**
  
 ____2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
 _XX_ 3.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. FOR
 THE ROOF TILES INDICATE WHICH FASTEN METHOD WILL BE
 USED.
 _XX_4.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
 _XX5.)OK
  
 _XX 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.**PROVIDE
 THE RAS 117 CALCULATIONS TO MEET THE ENHANCED FASTENER
 DENSITIES FOR THE FLAT ROOF**.
  
 **NOTE** PAGE 16 OF THE PRODUCT APPROVAL INDICATE THE
 SPACING OF THE NAILS AND TIN CAPS AT 9 INCHES ON CENTER
 IN TWO STAGGERED ROWS TO ACHIEVE -52.5 PSF. THE
 INFORMATION SUBMITTED FOR THE ENHANCE FASTENING SHOW
 THE SPACING OF THE NAILS AT 12 INCHES ON CENTER FOR
 EACH ZONE AND THE PRESSURES INCREASES FORM -49.2 PSF IN
 ZONE 1 TO -82.6 PSF IN ZONE 2 AND-124.3 PSF IN ZONE
 3. IF THE SPACE IS INCREASED FROM 9 INCHES TO 12 INCHES
 HOW IS IT POSSIBLE TO ACHIEVE HIGHER PRESSURES?THE
 PRODUCT APPROVAL SHALL BE INCLUDED IN THE CALCULATIONS
 OF THE ENHANCED FASTENING.THE PRODUCT APPROVAL ALSO
 STATES THAT THE CALCULATIONS SHALL BE IN COMPLIANCE
 WITH RAS 117 NOT RAS 150.THE INFORMATION PROVIDED IS
 NON-COMPLIANT.
  
 3)OK
  
 4)2303.4.1 TRUSS DESIGN DRAWINGS.
 TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A
 REGISTERED DESIGN PROFESSIONAL AND SHALL BE PROVIDED TO
 THE BUILDING OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION. SUBMIT THE FLAT AND HIP ROOF INFORMATION.
 *****NOTED*****
  
 **NOTE** A SEPARATE PERMIT IS REQUIRED FOR EACH
 STRUCTURE LOCATED AT DIFFERENT LOCATIONS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-09-26 Cont ID  
Sent By mjacobs Date 2007-09-26 Time 11:31 Rev Time 0.00
Received By mjacobs Date 2007-09-26 Time 06:24 Sent To  
Notes
2007-09-26 11:31:25BUILDING PLAN REVIEW
 PERMIT: 07060613
 ADD: 2300 PRESIDENTIAL WAY
 CONT: GRUBER HALL CORP INC.
 TEL: (561)697-3401
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)) 106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. PROVIDE PRODUCT APPROVALS FOR
 ALL ROOFING MATERIALS/ EXTERIOR DOORS/PRE-CAST
 LINTEL/BAHAMA SHUTTERS AND THE ROLING STEEL DOOR.
 **THE PRODUCT APPROVAL FOR THE PRE-CAST LINTEL IS
 MISSING FROM THE PACKAGE.**
  
 ROOFING ; ONLY CHECKED ITEMS APPLY
 ____1.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED
 POLICY:MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE /
 AREA OF EACH ROOF TYPE
  
 ____2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 _XX_ 3.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS. FOR
 THE ROOF TILES INDICATE WHICH FASTEN METHOD WILL BE
 USED.
  
 _XX_4.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
  
 _XX5.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING. **ON PAGE #4 OR #5
 OF THE ROOF TILE PRODUCT APPROVAL CIRCLE WHICH ITEM
 WILL BE USED**.
  
 _XX 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.**PROVIDE
 THE RAS 117 CALCULATIONS TO MEET THE ENHANCED FASTENER
 DENSITIES FOR THE FLAT ROOF**.
  
 3)OK
  
 4)2303.4.1 TRUSS DESIGN DRAWINGS.
 TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A
 REGISTERED DESIGN PROFESSIONAL AND SHALL BE PROVIDED TO
 THE BUILDING OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION. SUBMIT THE FLAT AND HIP ROOF
 INFORMATION.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-18 Cont ID  
Sent By mjacobs Date 2007-07-18 Time 14:19 Rev Time 0.00
Received By mjacobs Date 2007-07-17 Time 10:04 Sent To  
Notes
2007-07-17 12:58:26BUILDING PLAN REVIEW
 PERMIT: 07060613
 ADD: 2300 PRESIDENTIAL WAY
 CONT: GRUBER HALL CORP INC.
 TEL: (561)697-3401
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST.
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)) 106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. PROVIDE PRODUCT APPROVALS FOR
 ALL ROOFING MATERIALS/ EXTERIOR DOORS/PRE-CAST
 LINTEL/BAHAMA SHUTTERS AND THE ROLING STEEL DOOR.
  
 ROOFING ; ONLY CHECKED ITEMS APPLY
 ____1.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED
 POLICY:MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE /
 AREA OF EACH ROOF TYPE
  
 ____2.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
  
 ____3.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 IF THE OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS.
 FOR THE ROOF TILES INDICATE WHICH FASTEN METHOD WILL
 BE USED.
  
 ____4.)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
  
 ____5.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH
 METHOD OF ATTACHMENT YOU ARE USING.
  
 ____ 6.)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
  
  
 3)THE TITLE BLOCK IS MISSING THE FIRM LICENSE NUMBER.
 SEE FAC. 61G1-16.004.
  
 4)2303.4.1 TRUSS DESIGN DRAWINGS.
 TRUSS CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A
 REGISTERED DESIGN PROFESSIONAL AND SHALL BE PROVIDED TO
 THE BUILDING OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION. SUBMIT THE FLAT AND HIP ROOF
 INFORMATION.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-10-29 Cont ID  
Sent By dpalmer Date 2007-10-29 Time 09:53 Rev Time 0.00
Received By dpalmer Date 2007-10-29 Time 09:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2007-10-20 Cont ID  
Sent By dpalmer Date 2007-10-20 Time 08:21 Rev Time 0.00
Received By dpalmer Date 2007-10-20 Time 08:21 Sent To B
Notes
2007-10-20 08:23:30 
 ** PLANS WILL REMAIN IN FAILED STATUS UNTIL THE PERMITS
 AND PLANS ARE DETERMINED.
 IT IS STILL THE UNDERSTANDING AS PREVIOUSLY MENTIONED
 THAT TWO PERMITS AND TWO SETS OF PLANS ARE REQUIRED.
 THIS WILL BE GONE OVER WITH BUILDING OFFICIAL.
 ELECTRICAL PLANS ARE ALREADY STAMPED.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-09-18 Cont ID  
Sent By dpalmer Date 2007-09-18 Time 14:22 Rev Time 0.00
Received By dpalmer Date 2007-09-18 Time 14:08 Sent To I
Notes
2007-09-18 14:26:04** NOTES.
  
 1) NOTE: PLEASE SEEAS PREVIOUSLY STATED THIS SHOULD
 BE TWO SEPARATE PERMITS AS THESE ARE TWO SEPARATE
 STRUCTURES, IN TWO SEPARATE LOCATIONS.,TWO SEPARATE
 ELECTRICAL SERVICES ETC.
 INSPECTIONS ETC?
  
 THIS WILL REMAIN IN A FAILED STATUS UNTIL THIS IS
 CONFIRMED. ELECTRICAL SHEETS ARE STAMPED AS OK, HOWEVER
 STILL MAY NEED ADDITIONAL PLANS.
2007-09-18 14:09:42REMOVED FROM INCOMING DUE TO DATED ORDER OF ELECTRICAL
 REVIEW.
 WILL RETURN TO IMCOMING WATING FOR COMM BOARD ONCE
 REVIEW IS DONE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-07-02 Cont ID  
Sent By dpalmer Date 2007-07-02 Time 16:52 Rev Time 0.00
Received By dpalmer Date 2007-07-02 Time 15:38 Sent To I
Notes
2007-07-02 16:52:552007-07-02 16:52:55
  
 *** UNSAT ***
  
  
 ** PLEASE KNOW THERE MAY BE NEW COMMENTS ONCE
 ADDITIONAL INFORMATION IS SUBMITTED.
  
 1) NOTE: PLEASE SEE THE SUBMITTED DOCUMENTS REQUIRE THE
 CODES TO BE STATED ON PLANS. PLEASE SEE THE FOLLOWING
 ARE REQUIRED FOR ELECTRICAL AND OTHERS WILL BE REQUIRED
 FOR OTHER TRADES. PLEASE KNOW AS OF DECEMBER 8TH, 2006
 THE STATE ADOPTED THE 2006 REVISIONS TO THE 2004 FBC
 AND THE 2005 NFPA-70. PLEASE SEE THE PLANS DENOTE THE
 2005 REVISIONS.
 PLEASE LIST THE FOLLOWING:
 2004 FBC W/ 2006 REVISIONS.
 2005 NFPA-70
 2003 NFPA-101
 2002 NFPA-72
  
 2) NOTE: PLEASE SEE NOTES FROM BUILDING AND ADDRESSING
 REVIEWER(S) AS EACH BUILDING MAY REQUIRE SEPARATE
 PERMIT APPLICATIONS. PLEASE ALSO SEE THE ADDRESSING OF
 EACH WILL BE CHANGED FOR EXTENSIONS UNDER THE COMMON
 AREA ADDRESS.
 PLEASE ADJUST TITLE BLOCKS WITH ANY NEW ADDRESS AT
 DETERMINED BY THIS OFFICE.
 PLEASE KNOW, IF EACH BUILDING IS UNDER SEPARATE
 PERMITS, TWO SETS OF PLANS WILL BE REQUIRED FOR EACH.
 FAC 61G1-16.004
 FBC 106.1
  
 3) NOTE: PLEASE SEE MISSING INFORMATION ON TITLE BLOCKS
 FOR ARCHITECTURAL FIRM AS REQUIRED PER FAC 61G1-16.004,
 FS 481.219.
 PLEASE SEE MISSING THE CERTIFICATE OF AUTHORIZATION
 NUMBER ALSO KNOWN AS THE FIRM LICENSE NUMBER.
  
 4) NOTE: PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS ARE
 NOT OF SUFFICIENT SIZE PER 310.16, 240.4.
 PLEASE SEE MINIMUM SIZE REQUIRED FOR THE 100AMP MAIN AS
 SHOWN.
  
 5) NOTE: PLEASE SEE RISER INDICATES AN *EQUIPMENT
 GROUNDING CONDUCTOR* FROM FPL BEFORE THE FIRST MEANS OF
 DISCONNECT WHICH IS NOT PERMITTED. PLEASE SEE 250.6 AND
 250.24.
 THE EQUIPMENT GROUNDING CONDUCTOR IS ONLY INSTALLED
 AFTER THE FIRST MEANS OF DISCONNECT.
  
 6) NOTE: PLEASE SEE 2005 NEC AS OUTDOOR RECEPTACLES IN
 210.8B4 REQUIRE GFI PROTECTION EVEN FOR DEDICATE
 CIRCUITS/DEVICES/APPLIANCES.
  
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
2007-07-02 15:36:122007-07-02 15:36:12
 PLANS REMOVED FROM INCOMING. PLANS WILL RETURN TO
 INCOMING WAITING FOR COMM BOARD ONCE ELECTRICAL REVIEW
 IS DONE.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2007-08-03 Cont ID  
Sent By rchokshi Date 2007-08-03 Time 15:38 Rev Time 0.00
Received By rchokshi Date 2007-08-03 Time 15:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-07-30 Cont ID  
Sent By mwennerg Date 2007-07-30 Time 10:56 Rev Time 0.00
Received By mwennerg Date 2007-07-30 Time 10:56 Sent To  
Notes
2007-07-30 11:03:24PLANS APPROVED AND WILL BE STAMPED WHEN RETURNED FOR
 OTHER CORRECTIONS.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-11 Cont ID  
Sent By adarroug Date 2007-10-11 Time 11:44 Rev Time 0.00
Received By adarroug Date 2007-10-11 Time 11:44 Sent To  
Notes
2007-10-16 18:00:32 
 SENT TO JOHN ROACH FOR REVIEW.NEEDS ZONING AND
 BUILDING ONLY BECAUSE ELECTRICAL AND PLUMBING EACH HAVE
 THE SAME PROCEDURAL COMMENT.
2007-10-11 11:45:16WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-09-14 Cont ID  
Sent By adarroug Date 2007-08-27 Time 08:16 Rev Time 0.00
Received By adarroug Date 2007-08-27 Time 08:16 Sent To  
Notes
2007-09-20 09:38:35TO "COMM" BD#63
2007-09-14 08:17:23WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-08-03 Time   Rev Time 0.00
Received By adarroug Date 2007-06-21 Time 16:48 Sent To  
Notes
2007-07-09 14:11:28TO "COMM" BD#19
2007-06-21 16:48:58WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-07-18 Cont ID  
Sent By rregueir Date 2007-07-18 Time 16:50 Rev Time 0.00
Received By rregueir Date 2007-07-18 Time 16:47 Sent To  
Notes
2007-07-18 16:50:24MECHANICAL PERMIT REQUIRED FOR EXHAUST FANS. MECHANICAL
 CONTRACTOR CAN SIGN ON TO THIS PERMIT AS A
 SUBCONTRACTOR OR FILE A SEPARATE PERMIT APPLICATION
 REFERENCING THIS PERMIT ONCE IT IS ISSUED.
  
 RONALD J REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 5 Status P Date 2007-12-07 Cont ID  
Sent By kstevens Date 2007-12-07 Time 09:41 Rev Time 0.00
Received By kstevens Date 2007-12-07 Time 09:41 Sent To  
Notes
2007-12-07 09:42:03REVISION OK - 8-1/2" X 11" REVISION OF SHEET A-6.

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-10-25 Cont ID  
Sent By kstevens Date 2007-10-25 Time 16:02 Rev Time 0.00
Received By kstevens Date 2007-10-25 Time 16:02 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2007-10-23 Cont ID  
Sent By kstevens Date 2007-10-23 Time 07:10 Rev Time 0.00
Received By kstevens Date 2007-10-19 Time 17:46 Sent To  
Notes
2007-10-23 07:11:51PLUMBING PLANS APPROVED AND STAMPED, BUT REVIEW STOP
 SHALL REMAIN IN FAILED STATUS UNTIL THE ISSUE OF TWO
 PERMITS IS RESOLVED.

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-10-04 Cont ID  
Sent By kstevens Date 2007-10-04 Time 17:31 Rev Time 0.00
Received By kstevens Date 2007-10-04 Time 17:31 Sent To  
Notes
2007-10-04 17:42:20PLUMBING PLANS APPROVED AND STAMPED, BUT REVIEW STOP
 SHALL REMAIN IN FAILED STATUS UNTIL THE ISSUE OF TWO
 PERMITS IS RESOLVED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-07-17 Cont ID  
Sent By kstevens Date 2007-07-17 Time 08:21 Rev Time 0.00
Received By kstevens Date 2007-07-17 Time 08:21 Sent To  
Notes
2007-07-17 08:27:25DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. ALL SHEETS. THE FIRM LICENSE NUMBER SHALL BE
 INCLUDED IN THE TITLE BLOCK. FAC 61G1-16.002(2) & FS
 481.219, 481.2055.-TITLE BLOCK INDICATES A
 CORPORATION (LC).
  
 2. SUBMIT A WATER RISER DIAGRAM. SHOW ALL PIPE SIZES,
 VALVES, AND WATER HAMMER ARRESTORS, (SEE PLUMBING
 COMMENT #18). WATER HAMMER ARRESTORS SHALL BE LOCATED
 NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" NOT IN THE
 CEILING PER PDI-WH 201 AND MANUF INSTALLATION
 INSTRUCTIONS. 106.3.5.1.3(3)(10)(13).
  
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2007-10-19 Cont ID  
Sent By jroach Date 2007-10-19 Time 15:07 Rev Time 0.00
Received By jroach Date 2007-10-19 Time 15:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2007-09-20 Cont ID  
Sent By jroach Date 2007-09-20 Time 17:44 Rev Time 0.00
Received By jroach Date 2007-09-20 Time 17:44 Sent To  
Notes
2007-09-20 17:45:21***FAILED***
  
 1) TWO (2) COPIES OF A CURRENT, ACCURATE SURVEY SHALL
 BE PROVIDED SHOWING THE LOCATION OF THE PROPOSED
 STRUCTURES.NO SURVEY WAS PROVIDED.
  
 2) SURVEYS SHALL NOTE THE SETBACKS FROM THE NEAREST
 PROPERTY LINES.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-07-22 Cont ID  
Sent By jroach Date 2007-07-22 Time 21:05 Rev Time 0.00
Received By jroach Date 2007-07-22 Time 21:04 Sent To  
Notes
2007-07-22 21:06:43***FAILED***
  
 1) TWO (2) COPIES OF A CURRENT, ACCURATE SURVEY SHALL
 BE PROVIDED SHOWING THE LOCATION OF THE PROPOSED
 STRUCTURES.NO SURVEY WAS PROVIDED.
  
 2) SITE PLANS AND SURVEYS SHALL NOT THE SETBACKS FROM
 THE NEAREST PROPERTY LINES.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.