Plan Review Details - Permit 07060565
| Plan Review Stops For Permit 07060565 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-04 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-04 |
Time |
17:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-07-31 |
Time |
07:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-07-31 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2007-07-31 07:54:48 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)SEE OPENING 1.SECTION 2, TOP AND SECTION 6, | | | BOTTOM REQUIRE A CONCRETE SUBSTRATE.YOU MUST USE THE | | | "TO MASONRY" COLUMN FOR CBS, NOT "TO CONCRETE".PLEASE | | | REVISE EITHER THE SUBSTRATE OR THE CONNECTION TYPE. | | | CHECK ALL OPENINGS AS THIS COMMENT MAY APPLY TO OTHER | | | OPENINGS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-26 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-26 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2007-06-26 11:20:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)TWO COMPLETE COLLATED LEGIBLE SETS OF PERMIT | | | DOCUMENTS REQUIRED.ONLY ONE INSTALLATION SCHEDULE WAS | | | SUBMITTED AND THE PRODUCT APPROVALS ARE DIFFICULT TO | | | READ. | | | | | | 2.)YOU'VE CIRCLED 8" SPACING ON THE PRODUCT APPROVAL | | | BUT SPECIFIED 12".ALSO NOTE THAT ANCHOR SPACING TO BE | | | REDUCED BY .86 DUE TO 3"EDGE DISTANCE, SEE PAGE 6. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-28 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-28 |
Time |
11:01 |
Sent To |
B |
|
| Notes |
| 2007-08-28 11:02:15 | TO "SHILL' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
15:23 |
Sent To |
B |
|
| Notes |
| 2007-07-30 15:24:01 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-26 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-20 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2007-06-20 09:31:58 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy