Plan Review Details - Permit 07060554
| Plan Review Stops For Permit 07060554 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-27 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-27 |
Time |
17:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-19 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-19 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2007-11-19 12:46:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | 1.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2.THE APPLICATION STATES THE WINDOWS ARE | | | IMPACT, PRODUCT APPROVALS ARE NON IMPACT.PLEASE | | | ADDRESS. | | | | | | 2ND REVIEW - RESPONSE LETTER STATES THAT THE | | | APPLICATION STATES NON IMPACT.IT APPEARS TO SAY "NEW | | | IMPACT".REGARDLESS, IMPACT PROTECTION IS STILL | | | REQUIRED REGARDLESS OF WHAT THE APPLICATION STATES, SEE | | | FBC EB507.2. | | | | | | 2.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | 2ND REVIEW - NOT ADDRESSED; PLEASE GO TO THE WEBSITE | | | AND PRINT THE FLORIDA STATE PRODUCT APPROVALS AS | | | REQUIRED. | | | 3RD REVIEW - THE WORD "LOCAL" WAS WRITTEN ON THE NOAS. | | | I LOOKED UP TM, SINGLE HUNG WINDOW, AND FOUND A FLORIDA | | | STATE PRODUCT APPROVAL.A LOCAL WILL NOT BE ISSUED IF | | | A FLORIDA STATE PRODUCT APPROVAL HAS ALREADY BEEN | | | ISSUED, PER BUILDING OFFICIAL. | | | | | | 3.PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE EXISTING | | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 505.1. | | | | | | 2ND REVIEW - PLEASE ADDRESS.CONTRACTOR WROTE A | | | STATEMENT THAT THERE WILL BE A CASEMENT IN EACH | | | BEDROOM.YOU ARE TO PROVIDE ALL INFORMATION REQUIRED, | | | INCLUDING BEDROOM LOCATIONS, WINDOW TYPES, AND SIZES. | | | 3RD REVIEW - THE FLOOR PLAN WAS PROVIDED BUT ROOM | | | DESIGNATIONS NOT SHOWN.PLEASE PROVIDE REQUIRED | | | INFORMATION. | | | | | | NEW COMMENTS: | | | | | | 4.THE INSTALLATION SCHEDULE IS INCOMPLETE. | | | | | | 5.PROVIDE THE COMPLETE PRODUCT APPROVAL INCLUDING | | | EVALUATION REPORT AND INSTALLATION INSTRUCTIONS FOR THE | | | SHUTTERS.ONLY THE FIRST FEW SHEETS WERE PROVIDED, BUT | | | THE ENGINEERING DETAILS AND ANCHOR SCHEDULE CHARTS WERE | | | NOT INCLUDED.THIS IS REQUIRED FOR PLAN REVIEW AND FOR | | | INSPECTIONS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-13 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-13 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2007-09-13 09:45:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST: | | | | | | _XX_4.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2.THE APPLICATION STATES THE WINDOWS ARE | | | IMPACT, PRODUCT APPROVALS ARE NON IMPACT.PLEASE | | | ADDRESS. | | | | | | 2ND REVIEW - RESPONSE LETTER STATES THAT THE | | | APPLICATION STATES NON IMPACT.IT APPEARS TO SAY "NEW | | | IMPACT".REGARDLESS, IMPACT PROTECTION IS STILL | | | REQUIRED REGARDLESS OF WHAT THE APPLICATION STATES, SEE | | | FBC EB507.2. | | | | | | _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | 2ND REVIEW - NOT ADDRESSED; PLEASE GO TO THE WEBSITE | | | AND PRINT THE FLORIDA STATE PRODUCT APPROVALS AS | | | REQUIRED. | | | | | | _XX_6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 505.1. | | | | | | 2ND REVIEW - PLEASE ADDRESS.CONTRACTOR WROTE A | | | STATEMENT THAT THERE WILL BE A CASEMENT IN EACH | | | BEDROOM.YOU ARE TO PROVIDE ALL INFORMATION REQUIRED, | | | INCLUDING BEDROOM LOCATIONS, WINDOW TYPES, AND SIZES. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-19 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-19 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2007-06-19 16:10:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | ***WINDOW OR DOOR PERMIT APPLICATION, ONLY CHECKED | | | ITEMS APPLY*** | | | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | ____2.PROVIDE BUILDING HEIGHT.DESIGN PRESSURES | | | FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE DESIGNED | | | USING ASCE7, FBC1609.1.1. DOCUMENTS PREPARED BY AN | | | ENGINEER AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | | SIGNED SEALED ORIGINALS FAC61G15-23.002. | | | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_4.IMPACT PROTECTION REQUIRED,FBC1609.1.4, FBC R | | | 301.2.1.2.THE APPLICATION STATES THE WINDOWS ARE | | | IMPACT, PRODUCT APPROVALS ARE NON IMPACT.PLEASE | | | ADDRESS. | | | | | | _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | _XX_6.PROVIDE A FLOOR PLAN SHOWING: WINDOW | | | LOCATIONS, SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE | | | EXISTING CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE | | | FOR BEDROOMS, FBC R310, FBC EB 505.1. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-16 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-16 |
Time |
08:18 |
Sent To |
B |
|
| Notes |
| 2007-11-16 08:18:36 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-11 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-11 |
Time |
16:46 |
Sent To |
B |
|
| Notes |
| 2007-09-11 16:47:11 | TO "SHILL' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-19 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-19 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2007-06-19 09:59:25 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy