Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-09-22 Cont ID  
Sent By amorse Date 2007-09-22 Time 12:53 Rev Time 0.00
Received By amorse Date 2007-09-22 Time 12:53 Sent To PC
Notes
2007-09-22 12:59:29 
  
 PASSED
  
 1)PLEASE NOTE THAT A 2X6 STANDARD MULLION WILL BE
 REQUIRED TO MEET THE DESIGN PRESSURES INDICATED ON THE
 DRAWING NOT THE 2X4 AS SPECIFIED IN THE NOTE UNDER THE
 WINDOW SCHEDULE. ALSO THE MAXIMUM STOREFRONT/FRENCH
 DOOR WIDTH IS 72" THEREFORE THE FIXED STOREFRONT
 WINDOWS ON EITHER SIDE MAY BE LARGER BUT SHOULD STILL
 BE WITHIN THE PRODUCT APPROVALS PARAMETERS.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-11 Cont ID  
Sent By amorse Date 2007-08-11 Time 15:04 Rev Time 0.00
Received By amorse Date 2007-08-11 Time 15:04 Sent To PC
Notes
2007-08-11 15:19:28 
  
 DENIED
  
 1)THE MIAMI-DADE NOA'S FOR THE LARGE MISSILE FIXED
 AND HORIZONTAL SLIDING WINDOWS AND THE SLIDING GLASS
 DOOR PRODUCT APPROVALS HAVE BEEN REVISED FOR THE
 STATEWIDE APPROVALS.
  
 2)THE STOREFRONT WINDOW AND DOOR PRODUCTS ARE NOT
 IMPACT RATED AS CALLED FOR ON THE DRAWINGS.
  
 3)PRODUCT APPROVALS WERE SUBMITTED FOR FRENCH DOOR
 AND STOREFRONT DOORS, ARE THESE FOR THE SAME LOCATION?
 PLEASE SUBMIT ONLY THE PRODUCT APPROVALS FOR THE DOORS
 THAT WILL BE INSTALLED.
  
 4)PROVIDE PRODUCT APPROVAL FOR METAL DOOR, # 3 ON THE
 DOOR SCHEDULE. WD/4 SHOWS NEW DOOR FOR ACCESS TO ROOF
 ON THE 5TH FLOOR.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-24 Cont ID  
Sent By amorse Date 2007-07-24 Time 18:17 Rev Time 0.00
Received By amorse Date 2007-07-24 Time 18:17 Sent To PC
Notes
2007-07-24 18:49:09 
 DENIED
  
 1)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF
 THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS
 PER 106.1 FBC PLEASE SIGN AND SEAL WIND LOAD
 CALCULATIONS.
  
 2)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS. PLEASE NOTE THAT WINDOW SCHEDULE ON A/10
 STATE COMPLIANCE WITH 2001 FBC
  
 3)PROVIDE WIND DESIGN DATA ON DRAWINGS PER
 1603.1.4 FBC
  
 4)THE PERMIT APPLICATION SHALL INCLUDE TWO
 COPIES OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA
 STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT
 LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES. ALL
 CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 5)THE CITY OF WEST PALM BEACH REQUIRES THE
 FLORIDA STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
  
 7)REMOVE ALL NON RELATED PAGES FROM THE PERMIT SETS
 SUCH AS SITE PLAN AND ROOF PLANAND INDICATE THE SCOPE
 OF WORK (WINDOW REPLACEMENT) IN THE TITLE BLOCK NOT
 CONDO CONVERSION.
  
 8)PROVIDE CURRENT PRODUCT APPROVALS FOR THE
 STOREFRONT ASSEMBLIES THAT WILL BE USED.
  
 9)THE PRODUCT APPROVAL FOR THE OUTSWING FRENCH DOORS
 HAS EXPIRED PLEASE SUBMIT CURRENT APPROVAL.
  
 10)ALL MIAMI-DADE NOA'S FOR WINDOW UNITS AND SLIDING
 GLASS DOORS HAVE BEEN REVISED.
  
 11)PROVIDE AN UPDATED WINDOW SCHEDULE WITH CORRECT
 PRODUCT APPROVAL NUMBERS, WIND PRESSURES, GLAZING
 TYPES, ETC.
  
 12)IF METAL DOORS ON THE DOOR SCHEDULE ARE BEING
 CHANGED PROVIDE PRODUCT APPROVALS IF NOT PROVIDE NOTE
 THAT EXISTING TO REMAIN.
  
 13)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-20 Cont ID  
Sent By adarroug Date 2007-09-20 Time 15:25 Rev Time 0.00
Received By adarroug Date 2007-09-20 Time 15:25 Sent To B
Notes
2007-09-20 15:28:50TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-03 Cont ID  
Sent By adarroug Date 2007-08-03 Time 15:42 Rev Time 0.00
Received By adarroug Date 2007-08-03 Time 15:42 Sent To B
Notes
2007-08-03 15:42:26TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-07-24 Time   Rev Time 0.00
Received By adarroug Date 2007-06-19 Time 15:19 Sent To  
Notes
2007-07-03 10:28:44TO "COMM" BD#4/PLANS ON RACK--FOLDED PLANS AND BINDERS
2007-06-19 15:20:05WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-07-19 Cont ID  
Sent By kstevens Date 2007-07-19 Time 16:57 Rev Time 0.00
Received By kstevens Date 2007-07-19 Time 16:57 Sent To  
Notes
2007-07-19 16:57:55NO PLUMBING WORK SHOWN THIS PERMIT


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved