| Plan Review Stops For Permit 07060502 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-26 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-09-26 |
Time |
16:54 |
Sent To |
PC |
|
| Notes |
| 2007-09-26 17:23:26 | PROCESS PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-09-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-23 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-09-23 |
Time |
08:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-09-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-01 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-31 |
Time |
14:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-25 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-22 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2007-06-25 08:39:07 | BUILDING PLAN REVIEW | | | PERMIT: 07060502 | | | ADD: 2101 OKEECHOBEE BLVD | | | CONT: PROENACK CORP. | | | TEL: (561)691-2400 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)THE CALIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* | | | | | | 3)THE WINDOW SCHEDULE UNIT 3 SHOWS WINDOW (A) AND | | | (B), ARE THESE TWO WINDOWSBEING CHANGED TO IMPACT | | | WINDOWS? IF SO, SUBMIT THE PRODUCT APPROVAL FOR WINDOW | | | (A). DOOR SCHEDULE UNIT 2 HASTHE SAME PROBLEM, SO | | | SUBMIT THE PRODUCT APPROVAL FOR THE EXTERIOR STEEL | | | DOOR. | | | | | | 4)THE CONTRACTOR SHALL PRINT AND SIGN HIS/HER NAME ON | | | THE PERMIT APPLICATION. ALL SIGNATURES MUST BE | | | ORIGINAL. | | | | | | 5)THE DRAWINGS SUBMITTED ARE NOT ON THE STATE | | | WEBSITE. THE STATE APPROVAL STAMP IS ALSO MISSING FROM | | | THE PLANS. IF THESE PLANS WERE NOT APPROVED BY THE | | | STATE, THEY WILL BE REVIEWED BY ALL THE TRADES OF THE | | | BUILDING DEPARTMENT FOR CODE COMPLIANCE AND LIFESAFETY. | | | THE PLANS ARE ALSO MISSING PAGES 3-5. | | | | | | 6)FL ENERGY EFFICIENCY CODE 400.ABCD.2 | | | THE BUILDING'S OWNER, THE OWNER'S | | | ARCHITECT, OR OTHER AUTHORIZED AGENT | | | LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY TO THE BUILDING OFFICIAL THAT | | | THE BUILDING IS IN COMPLIANCE WITH THE | | | ENERGY EFFICIENTY CODE. | | | | | | 7)A COMPLETE EXTERIOR WALL DETAIL INDICATING ALL | | | MATERIALS SHALL BE SUBMITTED. | | | | | | | | | NOTE; THERE IS FLAG IN OUR COMPUTER SYSTEM REGUARDING | | | THE FOUNDATION PERMIT AT THIS LOCATION WHICH WILL SOON | | | BE EXPIRED, SHOW HOW THIS STRUCTURE WILL MEET THE | | | REQUIRED FOUNDATION REQUIREMENTS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-18 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-18 |
Time |
09:35 |
Sent To |
I |
|
| Notes |
| 2007-09-18 09:36:26 | PLANS REMOVED FROM INCOMING, ROUTED BACK TO INCOMING | | | WHERE THEY ARE NEXT IN LINE FOR COMM BOARD. | | | *NEW SHEETS, NEW SETS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-27 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-27 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2007-08-27 10:17:07 | *** DENIED *** | | | | | | 1) NOTE: PLEASE SEE THE REVISED ENERGY CALCULATIONS | | | SUBMITTED ARE MISSING THE INPUT DATA REPORTS FOR EACH | | | SET. | | | PLEASE SEE PAGE 2 OF THE SUMMARY SHEETS WHICH CLEARLY | | | STATES THE INPUT DATA REPORT IS REQUIRED TO ACCOMPANY | | | THE CALCULATIONS. | | | 13-415.1, 13-415.2, 13-103.1.1.1. | | | | | | 2) NOTE: PLEASE KNOW THIS OFFICE IS AWARE OF THE PLANS | | | AND SUPPORTING DOCUMENTS WHICH ARE *STATE APPROVED* ARE | | | PERMITTED TO BE PHOTO-COPIES OF THE STATE STAMPED | | | SIGNED AND SEALED PLANS AS LONG AS THEY MATCH WITH THE | | | STATE PLANS ON FILE. * THIS IS BEING DONE ON SEVERAL | | | SHEETS OF THE PLANS INCLUDING THE ENERGY CALCULATIONS. | | | PLEASE SEE SOME SHEETS DO HOWEVER CONTAIN AN ORIGINAL | | | SIGNATURE AND SEAL? | | | PLEASE KNOW HOWEVER PLACING A RAISED SEAL OVER A | | | PHOTO-COPIED SIGNATURE VIOLATES FAC 61G15-23.002 AND FS | | | 471.025. | | | THIS WAS CONFIRMED BY THE FLORIDA BOARD OF ENGINEERS | | | SOME TIME AGO THAT THE ENGINEER OF RECORD MAY NOT PLACE | | | A RAISED SEAL OVER THE SIGNATURE AS THIS IS LEADING TO | | | PLANS AND DOCUMENTS BEING*ORIGINAL*, WHICH THEY ARE | | | NOT. | | | THIS OFFICE HAS CONTACTED THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS AS OF THIS REVIEW AS THIS IS | | | STILL BEING DONE ON SEVERAL PROJECTS BY THE SAME | | | DESIGNER. | | | WE WILL BE AWAITING RULING FROM THE BOARD. *MAY SUBMIT | | | ONLY THE COPIED STATE STAMPED PLANS AS LONG AS THEY | | | CORRELATE WITH THE STATE SITE. | | | | | | | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-28 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-28 |
Time |
12:55 |
Sent To |
I |
|
| Notes |
| 2007-06-28 12:56:46 | PLANS ROUTED BACK TO INCOMING. | | 2007-06-28 12:56:31 | *** UNSAT *** | | | | | | | | | 1) NOTE: PLEASE SEE THE PLANS AS LISTED ON THE STATE | | | WEBSITE DO NOT CONTAIN THE CHANGES AS SUBMITTED AND | | | REVISED. | | | PLEASE KNOW IT APPEARS THE STATE LISTING MAY BE VOID | | | BASED ON THE REVISION SUBMITTED. | | | PLEASE SUBMIT COMPLETE ELECTRICAL DETAILS AS THE SCOPE | | | OF WORK WHICH WAS ON PREVIOUS PLANS IS BEING CHANGED. | | | PLEASE ADJUST CIRCUITING, PANEL SCHEDULE ETC | | | 408.4, 310.16, | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 2) NOTE: PLEASE SUBMIT COMPLETED AND REVISED ENERGY | | | CALCULATIONS BASED ON THE MODIFICATIONS OF THIS UNIT. | | | FBC 13-415.1.AB.1.1, 13-415.1.C ETC | | | 13-103.1.1.1 | | | | | | 3) NOTE: PLEASE SEE THE VALUE FOR THE SCOPE OF WORK IS | | | VERY LOW, PLEASE SEE THE VALUE IS TO INCLUDE ALL LABOR, | | | MATERIALS, EQUIPMENT, DESIGN COST ETC. | | | PLEASE SEE FBC 108.3 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-09-26 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-09-26 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2007-09-26 15:45:56 | PLANS APPROVED ON 9/6/07 AND STAMPED ON THIS DATE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-09-06 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-09-06 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-06-25 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-06-25 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2007-06-25 10:30:56 | ***DENIED*** | | | | | | 1) PLEASE SEE BUILDING REVIEW COMMENTS AND COMPLY. | | | | | | 2) WILL THIS WORK HAVE ANY IMPACT ON EXISTING FIRE | | | PROTECTION SYSTEMS, IE FIRE ALARM ETC? | | | | | | 3) CONSTRUCTION, ALTERATION AND DEMOLITION SHALL COMPLY | | | WITH NFPA 241. PLEASE ADD TO DESIGN DATA. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2007-09-18 14:31:33 | TO "COMM" BD#18--EXPEDITED-- | | 2007-09-17 15:26:31 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-03 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-03 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2007-08-27 08:24:02 | | | | 8/27/07 **SPECIAL MAGISTRATE CASE. EXPEDITE PLAN | | | REVIEW**.RB | | | | | 2007-08-03 15:59:47 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-06-25 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-06-18 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2007-06-29 10:57:27 | TO"COMM" BD#30 | | 2007-06-26 10:56:05 | 6/26/07--PULLED FROM "BOB"--WAITING FOR "COMM" BD | | 2007-06-18 14:39:06 | TO "BOB"#14 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-09-20 |
Time |
17:55 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-09-20 |
Time |
17:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-07-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-07-17 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-07-17 |
Time |
15:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-27 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-27 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-14 |
Time |
18:06 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-14 |
Time |
18:06 |
Sent To |
|
|
| Notes |
| 2007-07-14 18:22:04 | DENIED | | | REFERENCE: FBC-2004 | | | CHAPTER 1 | | | CHAPTER 11 | | | | | | 1.SEE COMMENT #5 FROM THE BUILDING PLAN REVIEW AND | | | COMMENT #1 FROM THE ELECTRICAL PLAN REVIEW.IF THE | | | PLANS ARE TO BE REVIEWED BY ALL REVIEWERS THEN THE | | | FOLLOWING INFORMATION WILL BE REQUIRED TO BE SHOWN ON | | | THE PLANS. | | | | | | FOR THE TOILET ROOMS: | | | __FOR THE W.C'S: | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.19.6 DISPENSERS | | | | | | FOR THE LAVS: | | | A. 11-4.19.2 CLEARANCES | | | B. 11-4.19.3 CLEAR FLOOR SPACE | | | | | | A DRINKING FOUNTAIN IS REQUIRED PER TABLE 403.1. | | | | | | BAR SINK SHALL SHOW COMPLIANCE WITH SECTION 11-4.24 | | | WITH ALL SUBSECTIONS. | | | | | | 2. THE FOLLOWING INFORMATION IS REQUIRED IN ANY CASE | | | FOR PLUMBING PERMIT: | | | | | | AN RPZV BACKFLOW IS REQUIRED PER SECTION 608.13.2. | | | | | | A SITE PLAN SHOWING THE SEWER LATERAL AND THE WATER | | | METER LOCATIONS. BACKFLOW SHALL BE AS CLOSE TO THE | | | METER BUT ON PRIVATE PROPERTY . | | | | | | SHOW THE WATER SERVICE AND THE SEWER LINES AND INDICATE | | | THEIR ROUTING. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|