Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-03 Cont ID  
Sent By shill Date 2007-08-03 Time 15:35 Rev Time 0.00
Received By shill Date 2007-08-03 Time 15:35 Sent To  
Notes
2007-08-03 15:40:13****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 FROM PREVIOUS LIST:
  
 1.)PROVIDE STRUCTURAL DETAILS FOR ALL CONNECTIONS,
 SHED PLAN.
  
 2.)DETAILS PROVIDED ARE INSUFFICIENT TO SHOW HOW THIS
 BUILDING WILL RESIST WIND LOADS FBC1609.FOR INSTANCE,
 NO SILL, TIE BEAM, RIDGE BEAM, ARE SHOWN ON THE SHED
 PLAN.PLANS ARE TO BE SPECIFIC AND DETAILED AND
 INCLUDE ALL INFORMATION REGARDING NUMBER AND TYPE OF
 FASTENERS.
  
 3.)PRODUCT APPROVALS REQUIRED FOR COMPONENTS AND
 CLADDING (ROOF, DOOR, WINDOW).
  
 4.)IMPACT PROTECTION REQUIRED FOR GLAZING,
 FBC1609.1.4.
  
 5.)DECLARE WIND DESIGN CRITERIA, FBC1603.1.4.
  
 6.)PROVIDE A SITE PLAN SHOWING THE DISTANCE FROM THE
 PROPERTY LINE AND ADJACENT BUILDINGS.
  
 7.)PROVIDE FOOTING DETAILS.DETAIL SUBMITTED DOES
 NOT SHOW ALL PERTINENT INFORMATION SUCH AS SIZE OF
 COLUMN, SIZE OF FOOTER.CALCULATIONS MAY BE REQUIRED.
  
  
 8.)PROVIDE A STRUCTURAL DETAIL FOR THE PORCH REPAIR
 AND PORCH EXTENSION.
  
 NEW COMMENT:
  
 9.)PLANS ARE TO BE ARCHITECTURAL QUALITY, TO SCALE.
  
 10.) WAS THIS PORCH PERMITTED PREVIOUSLY?THE STAIR
 RAIL DOES NOT COMPLY WITH FBC R 311.5.6.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-12 Cont ID  
Sent By shill Date 2007-07-12 Time 15:31 Rev Time 0.00
Received By shill Date 2007-07-12 Time 15:31 Sent To  
Notes
2007-07-12 15:38:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)PROVIDE STRUCTURAL DETAILS FOR ALL CONNECTIONS,
 SHED PLAN.
  
 2.)DETAILS PROVIDED ARE INSUFFICIENT TO SHOW HOW THIS
 BUILDING WILL RESIST WIND LOADS FBC1609.FOR INSTANCE,
 NO SILL, TIE BEAM, RIDGE BEAM, ARE SHOWN ON THE SHED
 PLAN.PLANS ARE TO BE SPECIFIC AND DETAILED AND
 INCLUDE ALL INFORMATION REGARDING NUMBER AND TYPE OF
 FASTENERS.
  
 3.)PRODUCT APPROVALS REQUIRED FOR COMPONENTS AND
 CLADDING (ROOF, DOOR, WINDOW).
  
 4.)IMPACT PROTECTION REQUIRED FOR GLAZING,
 FBC1609.1.4.
  
 5.)DECLARE WIND DESIGN CRITERIA, FBC1603.1.4.
  
 6.)PROVIDE A SITE PLAN SHOWING THE DISTANCE FROM THE
 PROPERTY LINE AND ADJACENT BUILDINGS.
  
 7.)PROVIDE CALCULATIONS TO SHOW HOW THE 4" SLAB WITH
 NO FOOTINGS WILL SUPPORT THE WEIGHT OF THIS STRUCTURE
 AND HOW THIS WILL RESIST OVERTURNING, FBC16.
  
 8.)PROVIDE A STRUCTURAL DETAIL FOR THE PORCH REPAIR
 AND PORCH EXTENSION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-30 Cont ID  
Sent By adarroug Date 2007-07-30 Time 15:47 Rev Time 0.00
Received By adarroug Date 2007-07-30 Time 15:47 Sent To Z
Notes
2007-07-30 15:48:01TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-12 Cont ID  
Sent By shill Date 2007-07-12 Time 15:38 Rev Time 0.00
Received By shill Date 2007-06-18 Time 10:53 Sent To  
Notes
2007-06-18 10:53:51TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status F Date 2007-08-01 Cont ID  
Sent By choops Date 2007-08-01 Time 17:21 Rev Time 0.00
Received By choops Date 2007-08-01 Time 17:21 Sent To B
Notes
2007-08-01 17:30:48***FAILED***
  
  
 1)TWO (2) COPIES OF ALL PLANS SHALL BE SUBMITTED.
  
 2)MUST INCLUDE TWO (2) COPIES OF A CURRENT SURVEY
 SHOWING THE SCOPE OF WORK WITH DIMENSIONS AND SETBACK
 DIMENSIONS TO THE PROPERTY LINES, THE EXISTING PORCH
 APPEARS TO BE A DIMENSIONAL NONCONFORMITY (DOES NOT
 MEET CURRENT SETBACK REQUIREMENTS)...A NONCONFORMING
 STRUCTURE MAY ONLY BE IMPROVED OR REPAIRED IF THE
 ALTERATION REDUCES THE IMPACT OF THE NONCONFORMITY UPON
 ADJACENT PROPERTIES(NO EXTENSION OF PORCH TO BE
 PERMITTED).
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By choops Date 2007-06-19 Time 13:05 Rev Time 0.00
Received By choops Date 2007-06-19 Time 13:05 Sent To B
Notes
2007-06-19 13:08:43***FAILED***
  
  
 1)PLEASE PROVIDE 2 COPIES OF A CURRENT SURVEY
 SHOWING THE LOCATION OF PROPOSED PATIO AND SHED WITH
 DIMENSIONS AND SETBACK DIMENSION TO ALL PROPERTY
 LINES.
  
 2)PLEASE INDICATE ON THE SURVEYS THE DISTANCE FROM
 THE PRINCIPAL STRUCTURE TO THE PROPOSED SHED.
  
 3)INDICATE HEIGHT OF PROPOSED SHED FROM GRADE TO THE
 MIDPOINT OF THE ROOF'S SLOPE.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720