| Plan Review Stops For Permit 07060440 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-06-27 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-06-27 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2007-06-27 09:49:16 | NEW ADDRESS ASSIGNED TO THE BILLBOARD LOCATION. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-07 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-12-07 |
Time |
07:37 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-11-14 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-11-14 |
Time |
07:40 |
Sent To |
PC |
|
| Notes |
| 2007-11-14 16:50:57 | BUILDING REVIEW THIRD CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2006 REVISIONS. | | | | | | 1- TIFFIN METAL PRODUCT DRAWING NO 140480S4SE: | | | A) ONLY ONE COPY WAS SUBMITTED. NEED TO PROVIDE TWO | | | COPIES AS REQUIRED BY SEC. 106.1 CITY AMENDMENTS TO FBC | | | 2004. | | | | | | B) ENGINEER CAN'T USE A RUBBER STAMP SIGNATURE. NEED | | | TO PROVIDE ORIGINAL SIGNATURE. IN ADDITION ENGINEER TO | | | REVIEW SEC. 61G15-23.002(2)OF FLORIDA ADMINISTRATIVE | | | CODE AND PROVIDE ALL HIS INFORMATION AS REQUIRED. | | | | | | 2-DRAWINGS AND CALCULATIONS PERFORMED BY EFFECTIVE | | | ENGINEERING SOLUTIONS, LTD: | | | A) DRAWING 1 OF 1 NEEDS TO CLEARLY PROVIDE THE NAME | | | OF THE ENGINEER SIGNING AND SEALING THE DRAWINGAS | | | REQUIRED BY SEC. 61G15-23.002(2) OF FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | B) CALCULATIONS NEED TO PROVIDE THE NAME OF THE | | | ENGINEER ON EACH SHEET AND SIGN AND SEAL EACH SHEET AS | | | REQUIRED BY SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE | | | CODE. | | | | | | C) SHEET 2 OF 28 OF ENGINEER CALCULATIONS NEED TO | | | REVISE THE FLORIDA BUILDING CODE EDITION REFERENCED. | | | CORRECT FLORIDA BUILDING CODE IS 2004, NOT 2003. | | | | | | 3- PROVIDE 2 COPIES OF SURVEYS AND TWO COPIES OF | | | LANDSCAPE PLANS AS REQUIRED BY SEC. 106.1 CITY | | | AMENDMENTS TO FBC 2004. ONLY ONE COPY SUBMITTED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-10-19 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-10-19 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2007-10-19 17:34:50 | BILLBOARD BUILDING REVIEW SECOND CHECKLIST. | | | REVIEW UNDER FBC 2004 WITH 2006 REVISIONS. | | | | | | 1- DRAWINGS PREPARED BY EFFECTIVE ENGINEERING | | | SOLUTIONS, LTD ARE MISSING THE NAME OF THE ENGINEER AS | | | REQUIRED BY FLORIDA ADMINISTRATIVE CODE SEC. | | | 61G15-23.002. | | | | | | 2- BILLBOARD HEIGHT OF 50'-0" SPECIFIED ON THE ENGINEER | | | CALCULATIONS IS INCORRECT. SEEDRAWINGS FOR CORRECT | | | HEIGHT AND REVISE CALCULATIONS AS REQUIRED.SEC. 1609 | | | FBC 2004. | | | | | | 3- SOIL TEST REPORT BY NUTTING ENGINEERS NEEDS TO HAVE | | | THE ENGINEERING FIRM CERTIFICATE OF AUTHORIZATION | | | NUMBER AS REQUIRED BY FLORIDA ADMINISTRATIVE CODE SEC. | | | 61G15-23.002. | | | | | | 4- ALL ENGINEERING DRAWINGS AND CALCULATIONSNEED TO | | | HAVE ORIGINAL SEAL AND SIGNATUREANDENGINEER'S | | | INFORMATION AS REQUIRED BY FLORIDA ADMINISTRATIVE CODE | | | SEC. 61G15-23.002. | | | | | | REVIEW IN PROGRESS. SENT TO ROBERT BROWN FOR | | | ENGINEERING REVIEW. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-08-01 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-08-01 |
Time |
18:34 |
Sent To |
PC |
|
| Notes |
| 2007-08-01 18:53:09 | BUILDING REVIEW CHECKLIST: | | | 1- NEED TO PROVIDE TWOSIGNED AND SEALED SETS OF | | | PLANS. ONLY ONE SUBMITTED. | | | | | | 2-A) NOTES ON RIGH HAND SIDE STATE THAT "THIS DESIGN | | | COMPLIES WITH ASCE 7-01". THERE IS NOT ASCE 7 01. | | | CORRECT ASCE 7 TO BE USED IS ASCE 7-02. | | | REVISE INFORMATION AS REQUIRED. | | | | | | B) IMPORTANCE FACTOR OF I=.77 IS INCORRECT. SEE ASCE | | | 7-02 AND REVISE AS REQUIRED. | | | | | | 3- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | 4- REVISE ALL PLANS AND SURVEY TO INCLUDE REVISED | | | ADDRESS.CORRECT ADDRESS TO BE USED FOR THIS PROJECT | | | IS 2203 MERCER AVE AS REVISED BY OUR ADDRESSING | | | DEPARTMENT. | | | | | | 5- UPDATE OWNER INFORMATION WITH PERMITCLERK. PROVIDE | | | REQUIRED PROOF OF OWNERSHIP. | | | | | | 6- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. 1802.2 | | | FBC 2004 AND NOTES ON ENGINEERED DRAWINGS. | | | | | | 7-A) ENGINEERED DRAWINGS TO PROVIDE COMPLETE ENGINEER | | | INFORMATION AS REQUIRED BY SEC. 61G15-23.002 OF FLORIDA | | | ADMINISTRATIVE CODE. READ THIS SECTION AND PROVIDE ALL | | | REQUIRED INFORMATION TO AVOID FUTURE DENIALS. | | | B) ENGINEERED DRAWINGS TO PROVIDE THE ENGINEERING | | | FIRM CERTIFICATE OF AUTHORIZATION NUMBER AS REQUIRED BY | | | SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE. | | | | | | 8- ENGINEERED DRAWINGS ONLY SHOW THE SIGN FRAMEWORK. | | | DRAWINGS ARE MISSING: | | | A) COMPLETE SPECS INCLUDING ATTACHMENT OF SIGN | | | ITSELF TO SHOW COMPLIANCE WITH WIND LOADS OF ASCE | | | 7-02. | | | | | | | | | B) GUARDRAIL ATTACHMENT TO SHOW COMPLIANCE WITH SEC. | | | 1607.7 FBC 2004. | | | | | | C) PLANS TO SHOW LOCATION OF GUARDRAILS. SEC. | | | 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-11 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-11 |
Time |
14:45 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-20 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-20 |
Time |
12:24 |
Sent To |
AD |
|
| Notes |
| 2007-06-20 12:38:12 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | 1} TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR | | | REVIEW PER 106.1 FBC AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-24 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-24 |
Time |
14:52 |
Sent To |
Z |
|
| Notes |
| 2008-04-24 14:53:07 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
|
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-12-05 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-12-05 |
Time |
13:44 |
Sent To |
Z |
|
| Notes |
| 2007-12-05 13:45:06 | SENT TO PLANNING SHELF. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-10-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-05 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-05 |
Time |
12:26 |
Sent To |
Z |
|
| Notes |
| 2007-10-05 12:27:31 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-22 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-22 |
Time |
15:11 |
Sent To |
AD |
|
| Notes |
| 2007-06-22 15:12:52 | PLANS IN ADRESSING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-20 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
10:35 |
Sent To |
E |
|
| Notes |
| 2007-06-20 10:36:09 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-08-01 |
Time |
19:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-06-15 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2007-06-15 13:43:41 | TO "Z" BOX |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-04-25 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-04-25 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-28 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-28 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2008-04-28 13:33:17 | IRRIGATION PERMIT REQUIRED. SUBMIT A IRRIGATION | | | APPLICATION WITH PLANS, PAY FEES. IRRIGATION PLANS ARE | | | OK AND WILL BE STAMP WHEN PERMIT APPLICATION AND PLANS | | | ARE RESUBMITTED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2008-04-25 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2008-04-24 |
Time |
17:27 |
Sent To |
P |
|
| Notes |
| 2008-04-25 16:15:57 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. | | | | | | IRRIGATION PERMIT REQUIRED PRIOR TO THE INSTALLATION OF | | | IRRIGATION SYSTEM. | | 2008-04-24 17:28:11 | SENT TO LANDSCAPE FOR REVIEW. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-06 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-12-06 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-12-06 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2007-12-06 14:02:09 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-10-11 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
ADAVILA |
Date |
2007-10-11 |
Time |
10:51 |
Sent To |
E |
|
| Notes |
| 2007-10-11 10:51:51 | ***FAILED*** | | | | | | 1.PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2.BILLBOARD STRUCTURE DIMENSIONS ON STRUCTURAL PLANS | | | DO NOT MATCH THE DIMENSIONS ON THE SITE PLAN.THE | | | SUBMITTED SITE PLAN SHOWS THE HEIGHT OF THE SIGN FACE | | | TO BE 13.58 FEET.THE STRUCTURAL PLAN SHOWS THE HEIGHT | | | OF THE SIGN FACE TO BE 14 FEET.ALL PLANS SHALL SHOW | | | SAME CONDITIONS.PLEASE REVISE. | | | | | | 3. SITE PLAN AND LANDSCAPE PLAN HAVE DIFFERENT SETBACK | | | DIMENSIONS.PLEASE REVISE. | | | | | | 4. LANDSCAPE PLANS SHALL BE SIGNED AND SEALED BY A | | | FLORIDA REGISTERED LANDSCAPE ARCHITECT. | | | | | | 5. TREE PLANTING PLANS SHALL COMPLY WITH THE CITY OF | | | WEST PALM BEACH SUSTAINABLE TREE PLANTING PLANS.SEE | | | ATTACHED DIAGRAM FOR REFERENCE. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-06-19 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-06-18 |
Time |
17:34 |
Sent To |
I |
|
| Notes |
| 2007-06-19 17:51:00 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2. ONLY 1 SET OF PLANS WERE SUBMITTED WITH THE PERMIT | | | APPLICATION.NEED TO SUBMIT AN ADDITIONAL COPY/SET (2 | | | SETS TOTAL). | | | | | | 3. BILLBOARD STRUCTURE DIMENSIONS ON STRUCTURAL PLANS | | | DO NOT MATCH THOSE APPROVED IN RESOLUTION NO. 112-07. | | | ALL PLANS SHALL SHOW SAME CONDITIONS. | | | | | | 4. PLEASE CLARIFY AND PROVIDE DETAILS OF THE ?REAR | | | WALKWAY.?ACCORDING TO THE STRUCTURAL PLANS, THE REAR | | | WALKWAY WAS OMITTED FOR CLARITY PURPOSES; HOWEVER REAR | | | WALKWAY SHALL BE SHOWN ON ALL PLANS WITH DIMENSIONS TO | | | ENSURE THAT THE BILLBOARD STRUCTURE COMPLIES WITH ALL | | | SETBACK DIMENSIONS.PLEASE NOTE THAT SETBACK | | | DIMENSIONS ARE MEASURED FROM THE PROPERTY LINE TO THE | | | FURTHEST PROJECTION POINT OF THE BILLBOARD STRUCTURE. | | | REAR WALKWAY MAY NOT ENCROACH FURTHER THAN THE REAR | | | SETBACK (10.93 FEET) AND THE SIDE SETBACK (32.5 FEET) | | | APPROVED IN RESOLUTION NO. 112-07. | | | | | | 5. LANDSCAPE PLAN AND LANDSCAPE AND PLANTING DETAILS | | | WERE NOT PROVIDED WITH THE APPLICATION PACKET. | | | LANDSCAPE PLANS AS APPROVED IN RESOLUTION NO. 112-07 | | | SHALL BE SUBMITTED AS PART OF THIS BUILDING PERMIT. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|