Plan Review Details - Permit 07060440
Plan Review Stops For Permit 07060440
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2007-06-27 Cont ID  
Sent By lursu Date 2007-06-27 Time 09:48 Rev Time 0.00
Received By lursu Date 2007-06-27 Time 09:48 Sent To  
Notes
2007-06-27 09:49:16NEW ADDRESS ASSIGNED TO THE BILLBOARD LOCATION.
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 OFFICE:822-1239
 FAX: 822-1249
 E-MAIL:[email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-12-07 Cont ID  
Sent By jgomez Date 2007-12-07 Time 09:55 Rev Time 0.00
Received By jgomez Date 2007-12-07 Time 07:37 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-11-14 Cont ID  
Sent By jgomez Date 2007-11-14 Time 16:52 Rev Time 0.00
Received By jgomez Date 2007-11-14 Time 07:40 Sent To PC
Notes
2007-11-14 16:50:57BUILDING REVIEW THIRD CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2006 REVISIONS.
  
 1- TIFFIN METAL PRODUCT DRAWING NO 140480S4SE:
 A) ONLY ONE COPY WAS SUBMITTED. NEED TO PROVIDE TWO
 COPIES AS REQUIRED BY SEC. 106.1 CITY AMENDMENTS TO FBC
 2004.
  
 B) ENGINEER CAN'T USE A RUBBER STAMP SIGNATURE. NEED
 TO PROVIDE ORIGINAL SIGNATURE. IN ADDITION ENGINEER TO
 REVIEW SEC. 61G15-23.002(2)OF FLORIDA ADMINISTRATIVE
 CODE AND PROVIDE ALL HIS INFORMATION AS REQUIRED.
  
 2-DRAWINGS AND CALCULATIONS PERFORMED BY EFFECTIVE
 ENGINEERING SOLUTIONS, LTD:
 A) DRAWING 1 OF 1 NEEDS TO CLEARLY PROVIDE THE NAME
 OF THE ENGINEER SIGNING AND SEALING THE DRAWINGAS
 REQUIRED BY SEC. 61G15-23.002(2) OF FLORIDA
 ADMINISTRATIVE CODE.
  
 B) CALCULATIONS NEED TO PROVIDE THE NAME OF THE
 ENGINEER ON EACH SHEET AND SIGN AND SEAL EACH SHEET AS
 REQUIRED BY SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE
 CODE.
  
 C) SHEET 2 OF 28 OF ENGINEER CALCULATIONS NEED TO
 REVISE THE FLORIDA BUILDING CODE EDITION REFERENCED.
 CORRECT FLORIDA BUILDING CODE IS 2004, NOT 2003.
  
 3- PROVIDE 2 COPIES OF SURVEYS AND TWO COPIES OF
 LANDSCAPE PLANS AS REQUIRED BY SEC. 106.1 CITY
 AMENDMENTS TO FBC 2004. ONLY ONE COPY SUBMITTED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-22 Cont ID  
Sent By jgomez Date 2007-10-19 Time 17:32 Rev Time 0.00
Received By jgomez Date 2007-10-19 Time 12:43 Sent To  
Notes
2007-10-19 17:34:50BILLBOARD BUILDING REVIEW SECOND CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2006 REVISIONS.
  
 1- DRAWINGS PREPARED BY EFFECTIVE ENGINEERING
 SOLUTIONS, LTD ARE MISSING THE NAME OF THE ENGINEER AS
 REQUIRED BY FLORIDA ADMINISTRATIVE CODE SEC.
 61G15-23.002.
  
 2- BILLBOARD HEIGHT OF 50'-0" SPECIFIED ON THE ENGINEER
 CALCULATIONS IS INCORRECT. SEEDRAWINGS FOR CORRECT
 HEIGHT AND REVISE CALCULATIONS AS REQUIRED.SEC. 1609
 FBC 2004.
  
 3- SOIL TEST REPORT BY NUTTING ENGINEERS NEEDS TO HAVE
 THE ENGINEERING FIRM CERTIFICATE OF AUTHORIZATION
 NUMBER AS REQUIRED BY FLORIDA ADMINISTRATIVE CODE SEC.
 61G15-23.002.
  
 4- ALL ENGINEERING DRAWINGS AND CALCULATIONSNEED TO
 HAVE ORIGINAL SEAL AND SIGNATUREANDENGINEER'S
 INFORMATION AS REQUIRED BY FLORIDA ADMINISTRATIVE CODE
 SEC. 61G15-23.002.
  
 REVIEW IN PROGRESS. SENT TO ROBERT BROWN FOR
 ENGINEERING REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-08-01 Cont ID  
Sent By jgomez Date 2007-08-01 Time 18:34 Rev Time 0.00
Received By jgomez Date 2007-08-01 Time 18:34 Sent To PC
Notes
2007-08-01 18:53:09BUILDING REVIEW CHECKLIST:
 1- NEED TO PROVIDE TWOSIGNED AND SEALED SETS OF
 PLANS. ONLY ONE SUBMITTED.
  
 2-A) NOTES ON RIGH HAND SIDE STATE THAT "THIS DESIGN
 COMPLIES WITH ASCE 7-01". THERE IS NOT ASCE 7 01.
 CORRECT ASCE 7 TO BE USED IS ASCE 7-02.
 REVISE INFORMATION AS REQUIRED.
  
 B) IMPORTANCE FACTOR OF I=.77 IS INCORRECT. SEE ASCE
 7-02 AND REVISE AS REQUIRED.
  
 3- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 4- REVISE ALL PLANS AND SURVEY TO INCLUDE REVISED
 ADDRESS.CORRECT ADDRESS TO BE USED FOR THIS PROJECT
 IS 2203 MERCER AVE AS REVISED BY OUR ADDRESSING
 DEPARTMENT.
  
 5- UPDATE OWNER INFORMATION WITH PERMITCLERK. PROVIDE
 REQUIRED PROOF OF OWNERSHIP.
  
 6- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. 1802.2
 FBC 2004 AND NOTES ON ENGINEERED DRAWINGS.
  
 7-A) ENGINEERED DRAWINGS TO PROVIDE COMPLETE ENGINEER
 INFORMATION AS REQUIRED BY SEC. 61G15-23.002 OF FLORIDA
 ADMINISTRATIVE CODE. READ THIS SECTION AND PROVIDE ALL
 REQUIRED INFORMATION TO AVOID FUTURE DENIALS.
 B) ENGINEERED DRAWINGS TO PROVIDE THE ENGINEERING
 FIRM CERTIFICATE OF AUTHORIZATION NUMBER AS REQUIRED BY
 SEC. 61G15-23.002 OF FLORIDA ADMINISTRATIVE CODE.
  
 8- ENGINEERED DRAWINGS ONLY SHOW THE SIGN FRAMEWORK.
 DRAWINGS ARE MISSING:
 A) COMPLETE SPECS INCLUDING ATTACHMENT OF SIGN
 ITSELF TO SHOW COMPLIANCE WITH WIND LOADS OF ASCE
 7-02.
  
  
 B) GUARDRAIL ATTACHMENT TO SHOW COMPLIANCE WITH SEC.
 1607.7 FBC 2004.
  
 C) PLANS TO SHOW LOCATION OF GUARDRAILS. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-10-11 Cont ID  
Sent By btrobaug Date 2007-10-11 Time 14:51 Rev Time 0.00
Received By btrobaug Date 2007-10-11 Time 14:45 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-20 Cont ID  
Sent By btrobaug Date 2007-06-20 Time 12:38 Rev Time 0.00
Received By btrobaug Date 2007-06-20 Time 12:24 Sent To AD
Notes
2007-06-20 12:38:12 
  
 DENIED/INCOMPLETE INFORMATION
  
 1} TWO SETS OF ALL DOCUMENTS MUST BE SUBMITTED FOR
 REVIEW PER 106.1 FBC AS AMENDED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-04-24 Cont ID  
Sent By adarroug Date 2008-04-24 Time 14:52 Rev Time 0.00
Received By adarroug Date 2008-04-24 Time 14:52 Sent To Z
Notes
2008-04-24 14:53:07TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status   Date 2007-12-05 Cont ID  
Sent By jgomez Date 2007-12-05 Time 13:45 Rev Time 0.00
Received By jgomez Date 2007-12-05 Time 13:44 Sent To Z
Notes
2007-12-05 13:45:06SENT TO PLANNING SHELF.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-10-05 Cont ID  
Sent By adarroug Date 2007-10-05 Time 12:26 Rev Time 0.00
Received By adarroug Date 2007-10-05 Time 12:26 Sent To Z
Notes
2007-10-05 12:27:31TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-22 Cont ID  
Sent By adarroug Date 2007-06-22 Time 15:11 Rev Time 0.00
Received By adarroug Date 2007-06-22 Time 15:11 Sent To AD
Notes
2007-06-22 15:12:52PLANS IN ADRESSING

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-20 Cont ID  
Sent By adarroug Date 2007-06-20 Time 10:35 Rev Time 0.00
Received By adarroug Date 2007-06-20 Time 10:35 Sent To E
Notes
2007-06-20 10:36:09TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-08-01 Cont ID  
Sent By jgomez Date 2007-08-01 Time 19:03 Rev Time 0.00
Received By jgomez Date 2007-06-15 Time 13:43 Sent To  
Notes
2007-06-15 13:43:41TO "Z" BOX

Review Stop L LANDSCAPING
Rev No 1 Status P Date 2008-04-25 Cont ID  
Sent By rkussner Date 2008-04-25 Time 14:15 Rev Time 0.00
Received By rkussner Date 2008-04-25 Time 14:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2008-04-28 Cont ID  
Sent By jleech Date 2008-04-28 Time 13:28 Rev Time 0.00
Received By jleech Date 2008-04-28 Time 13:09 Sent To  
Notes
2008-04-28 13:33:17IRRIGATION PERMIT REQUIRED. SUBMIT A IRRIGATION
 APPLICATION WITH PLANS, PAY FEES. IRRIGATION PLANS ARE
 OK AND WILL BE STAMP WHEN PERMIT APPLICATION AND PLANS
 ARE RESUBMITTED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 4 Status P Date 2008-04-25 Cont ID  
Sent By adavila Date 2008-04-25 Time 16:15 Rev Time 0.00
Received By adavila Date 2008-04-24 Time 17:27 Sent To P
Notes
2008-04-25 16:15:57PER ERIC SCHNEIDER, PRINCIPAL PLANNER.
  
 IRRIGATION PERMIT REQUIRED PRIOR TO THE INSTALLATION OF
 IRRIGATION SYSTEM.
2008-04-24 17:28:11SENT TO LANDSCAPE FOR REVIEW.

Review Stop Z ZONING
Rev No 3 Status P Date 2007-12-06 Cont ID  
Sent By adavila Date 2007-12-06 Time 14:01 Rev Time 0.00
Received By adavila Date 2007-12-06 Time 10:41 Sent To  
Notes
2007-12-06 14:02:09PER ERIC SCHNEIDER, PRINCIPAL PLANNER.

Review Stop Z ZONING
Rev No 2 Status F Date 2007-10-11 Cont ID  
Sent By eschneid Date 2007-10-11 Time 10:51 Rev Time 0.00
Received By ADAVILA Date 2007-10-11 Time 10:51 Sent To E
Notes
2007-10-11 10:51:51***FAILED***
  
 1.PROVIDE RESPONSE TO COMMENTS IN WRITING.
  
 2.BILLBOARD STRUCTURE DIMENSIONS ON STRUCTURAL PLANS
 DO NOT MATCH THE DIMENSIONS ON THE SITE PLAN.THE
 SUBMITTED SITE PLAN SHOWS THE HEIGHT OF THE SIGN FACE
 TO BE 13.58 FEET.THE STRUCTURAL PLAN SHOWS THE HEIGHT
 OF THE SIGN FACE TO BE 14 FEET.ALL PLANS SHALL SHOW
 SAME CONDITIONS.PLEASE REVISE.
  
 3. SITE PLAN AND LANDSCAPE PLAN HAVE DIFFERENT SETBACK
 DIMENSIONS.PLEASE REVISE.
  
 4. LANDSCAPE PLANS SHALL BE SIGNED AND SEALED BY A
 FLORIDA REGISTERED LANDSCAPE ARCHITECT.
  
 5. TREE PLANTING PLANS SHALL COMPLY WITH THE CITY OF
 WEST PALM BEACH SUSTAINABLE TREE PLANTING PLANS.SEE
 ATTACHED DIAGRAM FOR REFERENCE.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By adavila Date 2007-06-19 Time 17:50 Rev Time 0.00
Received By adavila Date 2007-06-18 Time 17:34 Sent To I
Notes
2007-06-19 17:51:00PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PROVIDE RESPONSE TO COMMENTS IN WRITING.
  
 2. ONLY 1 SET OF PLANS WERE SUBMITTED WITH THE PERMIT
 APPLICATION.NEED TO SUBMIT AN ADDITIONAL COPY/SET (2
 SETS TOTAL).
  
 3. BILLBOARD STRUCTURE DIMENSIONS ON STRUCTURAL PLANS
 DO NOT MATCH THOSE APPROVED IN RESOLUTION NO. 112-07.
 ALL PLANS SHALL SHOW SAME CONDITIONS.
  
 4. PLEASE CLARIFY AND PROVIDE DETAILS OF THE ?REAR
 WALKWAY.?ACCORDING TO THE STRUCTURAL PLANS, THE REAR
 WALKWAY WAS OMITTED FOR CLARITY PURPOSES; HOWEVER REAR
 WALKWAY SHALL BE SHOWN ON ALL PLANS WITH DIMENSIONS TO
 ENSURE THAT THE BILLBOARD STRUCTURE COMPLIES WITH ALL
 SETBACK DIMENSIONS.PLEASE NOTE THAT SETBACK
 DIMENSIONS ARE MEASURED FROM THE PROPERTY LINE TO THE
 FURTHEST PROJECTION POINT OF THE BILLBOARD STRUCTURE.
 REAR WALKWAY MAY NOT ENCROACH FURTHER THAN THE REAR
 SETBACK (10.93 FEET) AND THE SIDE SETBACK (32.5 FEET)
 APPROVED IN RESOLUTION NO. 112-07.
  
 5. LANDSCAPE PLAN AND LANDSCAPE AND PLANTING DETAILS
 WERE NOT PROVIDED WITH THE APPLICATION PACKET.
 LANDSCAPE PLANS AS APPROVED IN RESOLUTION NO. 112-07
 SHALL BE SUBMITTED AS PART OF THIS BUILDING PERMIT.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.