Plan Review Details - Permit 07060305
Plan Review Stops For Permit 07060305
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-04-11 Cont ID  
Sent By shill Date 2008-04-11 Time 13:17 Rev Time 0.00
Received By shill Date 2008-04-11 Time 13:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-10-30 Cont ID  
Sent By shill Date 2007-10-30 Time 10:01 Rev Time 0.00
Received By shill Date 2007-10-30 Time 10:01 Sent To  
Notes
2007-10-30 10:04:48****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2), FBC
 R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE C
 HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.IF YOU ARE USING AN EXEMPTION TO USE
 EXPOSURE B PER FBC EXISTING BUILDING CODE, PLEASE STATE
 EXEMPTION ON THE PLAN.
  
 2.SEE ZONING COMMENTS.ZONING APPROVAL REQUIRED FOR
 PERMIT ISSUANCE.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-12 Cont ID  
Sent By shill Date 2007-07-12 Time 15:01 Rev Time 0.00
Received By shill Date 2007-07-12 Time 15:01 Sent To  
Notes
2007-07-12 15:08:52****CORRECTIONS****
 REVISED 8/26/7
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS FAC61G15-23 (APPLICATION FOR DEP).THESE
 SHEETS MAY BE VOIDED, BUT THE THE PLANS PREPARED BY
 JAMES BUSHOUSE, PE ARE TO INCLUDE ALL INFORMATION TO
 DETERMINE CODE COMPLIANCE.
  
 2.)PROVIDE A SITE PLAN SHOWING WHERE THE DOCK WILL BE
 INSTALLED.
  
 3.)GUARDS ARE REQUIRED EXCEPT AS EXEMPTED, FBC1012.
 PLANS ARE TO INDICATE EXEMPTION IF APPLICABLE.IF
 GUARDS ARE REQUIRED, PROVIDE A DETAIL AND SPECIFY
 DESIGN CRITERIA FBC1012, FBC1607.7.
  
 4.)SHOW THE ACCESSIBLE ROUTE, FBC11-4. 1.2.SHOW
 SLOPE AND WIDTH.SPECIFY THE SPACING BETWEEN THE
 "TROPICAL DECKING" BOARDS.
  
 5.)DECLARE WIND DESIGN CRITERIA, FBC1603.1.4.
  
 NEW COMMENTS 8/28
  
 6.)DECLARE LEVEL OF ALTERATION ON THE PLAN, FBC EB
 CHAPTER 3.
  
 7.)SCOPE OF WORK IS NOT CLEAR.APPLICATION STATES
 "REPLACE EXISTING DOCK", CONTRACTOR STATED ON THE
 TELEPHONE THAT APPROXIMATELY 35% IS BEING REPLACED.
 PLEASE MAKE SCOPE OF WORK, PLANS, AND APPLICATION
 DESCRIPTION CONSISTENT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-10-22 Cont ID  
Sent By adarroug Date 2007-10-22 Time 11:25 Rev Time 0.00
Received By adarroug Date 2007-10-22 Time 11:25 Sent To Z
Notes
2007-10-22 11:25:28TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-12 Cont ID  
Sent By shill Date 2007-07-12 Time 15:09 Rev Time 0.00
Received By shill Date 2007-06-12 Time 09:01 Sent To  
Notes
2007-06-19 14:03:496/19/07--SENT TO "Z"
2007-06-12 09:02:20TO "MISC" BOX#1

Review Stop Z ZONING
Rev No 3 Status P Date 2008-04-11 Cont ID  
Sent By kdfreema Date 2008-04-11 Time 14:43 Rev Time 0.00
Received By kdfreema Date 2008-04-11 Time 14:43 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2007-10-25 Cont ID  
Sent By choops Date 2007-10-25 Time 10:51 Rev Time 0.00
Received By choops Date 2007-10-25 Time 10:51 Sent To B
Notes
2007-10-25 10:52:32***FAILED - RESUB #1***
  
 REPEAT COMMENT:
  
 1)PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A
 CLASS A SPECIAL USE PERMIT SHALL BE SUBMITTED TO AND
 APPROVED BY THE PLANNING AND ZONING DEPARTMENT.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-06-20 Cont ID  
Sent By choops Date 2007-06-20 Time 17:02 Rev Time 0.00
Received By choops Date 2007-06-20 Time 17:02 Sent To B
Notes
2007-06-20 17:03:54***FAILED***
  
  
 1)REQUIRES A CLASS "A" SPECIAL USE PERMIT.FOR
 FURTHER INFORMATION CONTACT THE PLANNING DEPARTMENT @
 561-822-1435
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved