Plan Review Details - Permit 07060304
| Plan Review Stops For Permit 07060304 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-29 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-29 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2007-09-04 09:27:13 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07060304 | | | ADD: 477 S.ROSEMARY AVE. | | | CONT: OCEAN DRIVE BUILDING CORP. | | | TEL: (561)833-3900 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)THE DRAWINGS PROVIDED DO NOT INDICATE CLEARLY THE | | | SCOPE OF WORK.PROVIDE TWO COMPLETE SETS OF DRAWINGS | | | WITH THE EXISTING FLOOR PLAN AND THE PROSOSED FLOOR | | | PLAN.PAGE 1 OF 6 SHOWS TWO SEPERATE UNITS. PROVIDE | | | SIMILAR DRAWINGS SHOWING HOW THE TWO UNITS WILL BECOME | | | ONE. THE PLANS PROVIDED SHOWS ONLY ONE UNIT WITH A | | | CASED OPENING. THE TOTAL FLOOR PLAN SHALL BE SHOWN. | | | FBC. 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL (SEE SECTION | | | 106.3.5) | | | | | | NEW*** | | | | | | 1)A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS | | | A RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | A)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR RECORD KEEPING & | | | FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT IS | | | DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE | | | PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, | | | TABLE 601. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED | | | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. | | | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE | | | BUILDING PERMIT | | | . ------------------------------------- | | | ) NUMBER OF UNITS | | | ) NUMBER OF FLOORS | | | ) NUMBER OF BEDROOMS | | | ) NUMBER OF ROOMS | | | ) NUMBER OF BEDROOMS | | | ) SQ. FT. LIV SPACE/ FL | | | ) SQ. FT. FOOTPRINT | | | | | | B)UNITS 207 AND 209 APPEARS TO BE RESIDENTIAL UNITS. | | | IF THESE UNITA ARE NOW BEING CHANGED AT BUSINESS, THE | | | CHANGE OF OCCUPANCY OR USE BOX SHALL BE CHECKED ON THE | | | APPLICATION. | | | | | | C) PROVIDE A LIFESAFETY PLAN SHOWING THE EGRESS PATH | | | AND TRAVEL DISTANCE. FBC. (BUILDING) 1013. | | | | | | D) 1006.3.1. EXIT SIGNS:EXIT SIGNS SHALL BE MARKED BY | | | AN APPROVED SIGN READILY VISIBLE FROM ANY DIRECTION OF | | | EXIT ACCESS. EVERY EXIT SIGN SHALL BE SUITABLE | | | ILLUMINATED BY A RELIABLE LIGHT SOURCE. EXTERNALLY AND | | | INTERNALLY ILLUMINATED SIGNS SHALL BE VISIBLE IN BOTH | | | THE NORMAL & EMERGENCY LIGHTING. | | | | | | E)FBC. (BUILDING) 11-4.3.4 IF DOORWAYS HAVE TWO | | | INDEPENDENTLY OPERATED DOORLEAVES, THEN ONE | | | LEAF SHALL BE AT LEAST 32 INCHES. THE DOUBLE DOORS | | | LEADING TO THE INTERIOR DESIGNER SPACE SHALL MEET THIS | | | REQUIREMENT. | | | | | | F)SINKS: 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER NO HIGHER | | | THAN 34" ABOVE THE FINISH FLOOR. 11-4.24.3 KNEE | | | CLEARANCE THAT IS AT LEAST 27" HIGH 30" WIDE, AND 19" | | | DEEP SHALL BE PROVIDED UNDERNEATH SINKS. 11-4.24.5 | | | CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES | | | (760 MM BY 1219 MM) COMPLYING WITH SECTION 11-4.2.4 | | | SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN | | | ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 | | | INCHES (485 MM) UNDERNEATH THE SINK. | | | | | | G) INDICATE THE INTERIOR WALL AND CEILING FINISH IN | | | ACCORDANCE WITH FBC.TABLE 803.5. | | | | | | H)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | I)INDICATE CLEARLY THE TYPE OF BUSINESS AND THE USE | | | OF EACH ROOM OR AREA ON THE PLANS. PROVIDE A WALL | | | LEGEND AND SHOW WHERE EACH TYPE OF WALL WILL BE | | | INSTALLED ON THE FLOOR PLANS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-21 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-21 |
Time |
08:54 |
Sent To |
|
|
| Notes |
| 2007-06-21 12:14:02 | BUILDING PLAN REVIEW | | | PERMIT: 07060304 | | | ADD: 477 S.ROSEMARY AVE. | | | CONT: OCEAN DRIVE BUILDING CORP. | | | TEL: (561)833-3900 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST. | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)THE DRAWINGS PROVIDED DO NOT INDICATE CLEARLY THE | | | SCOPE OF WORK.PROVIDE TWO COMPLETE SETS OF DRAWINGS | | | WITH THE EXISTING FLOOR PLAN AND THE PROSOSED FLOOR | | | PLAN.PAGE 1 OF 6 SHOWS TWO SEPERATE UNITS. PROVIDE A | | | SIMILAR DRAWINGS SHOWING HOW THE TWO UNITS WILL BECOME | | | ONE. THE PLANS PROVIDED SHOWS ONLY ONE UNIT WITH A | | | CASED OPENING. THE TOTAL FLOOR PLAN SHALL BE SHOWN. | | | FBC. 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL ( SEE SECTION | | | 106.3.5) | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-22 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-22 |
Time |
17:06 |
Sent To |
|
|
| Notes |
| 2007-08-22 17:32:20 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THERE ARE TWO PLANS SUBMITTED ON TWO DIFFERENT | | | SHEETS, IT IS UNCLEAR WHICH SET IS INTENDED FOR REVIEW. | | | REMOVE THE SET NOT INTENDED FOR REVIEW. SEE COMMENTS | | | FROM PREVIOUS REVIEW. | | | | | | 2} THE APPLICATIION HAS BEEN PARTIALLY "WHITED OUT", | | | FILL OUT A NEW APPLICATION. 106.1.3 FBC. | | | | | | 3} THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL | | | COST OF LABOR AND MATERIAL. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES PER 108.3 FBC AS | | | AMENDED. | | | | | | A PERMIT SHALL NOT BE ISSUED UNTIL FEES AUTHORIZED | | | UNDER SECTION 553.80, FLORIDA STATUTES, HAVE BEEN PAID. | | | 108.1 FBC. | | | | | | ADJUST THE VALUE AT THE PERMIT CLERK?S DESK, AND PAY | | | THE DIFFERENCE IN FEES PRIOR TO RESUBMITTING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-20 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-20 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2007-06-20 10:15:03 | | | | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | 1}INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS FOR | | | DEVICES SO THAT COMPLIANCE WITH CALCULATIONS FOR | | | 220.14(I) MAY BE REVIEWED. | | | | | | 2} PROVIDE AMPERAGE RATINGS FOR EXISTING PANELS. BOTH | | | PANELS ON SHEET 1/6 ARE DESIGNATED "D". REDESIGNATE FOR | | | CIRCUIT CLARITY. | | | | | | 3} SUBMIT A PANEL SCHEDULES PER 408.4 NEC AND | | | 106.3.5.4(8) FBC. | | | | | | 4} PROVIDE A CALCULATION FOR THE TRACK LIGHTING PER | | | 220.43(B). | | | | | | 5} 2} PROVIDE EMERGENCY ILLUMINATION PER | | | NFPA-101 7.8 (2003), AND CIRCUITED PER | | | 700.12 NEC. INDICATE SAME ON PLANS. | | | | | | 6} PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE | | | BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE | | | CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE SEE | | | ARTICLE. | | | | | | 7} INDICATE COMPLIANCE WITH CHAPTER 13 | | | OF THE FLORIDA BLDG CODE. 13.413, | | | 13.414, 13.415. SHOW TIME CLOCK AND | | | OCCUPANCY SENSOR LOCATIONS ON THE PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-27 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-27 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2007-08-27 13:15:16 | *****UNSAT***** | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | | CLEAR, CONCISE, AND CONSISTENT PLANS HAVE BEEN | | | SUBMITTED. | | | | | | | | | 01.NFPA 101, THE LIFE SAFETY CODE, 2003 EDITION SHALL | | | BE REFERENCED. | | | | | | 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS | | | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT | | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 04.THE REMOVAL AND/OR THE STOCKING OF NEW BUILDING | | | MATERIALS & SUPPLIES SHALL NOT INTERFERE OR HINDER WITH | | | EMERGENCY RESPONSE ACCESS TO THE PROPERTY OR VICINITY | | | THEREOF (INCLUDING STREETS, ROADS, FIRE LANES). | | | | | | 05.INDICATE IF THE EXISTING BUILDING OR PORTION | | | THEREOF REPRESENTS A CHANGE OF OCCUPANCY TO A BUSINESS | | | OCCUPANCY.IF SO, THE LIFE SAFETY REQUIREMENTS FOR A | | | NEW BUSINESS OCCUPANCY SHALL APPLY. | | | | | | 06.PLEASE PROVIDE THE OCCUPANT LOAD AS IN THE NUMBER | | | OF PERSONS FOR WHOM MEANS OF EGRESS AND OTHER | | | PROVISIONS ARE REQUIRED. | | | | | | 07.DOORS COMPLYING WITH NFPA 101, 7.2.1 SHALL BE | | | PERMITTED. | | | | | | 08.PLEASE PROVIDE TRAVEL DISTANCE TO EXIT(S). | | | | | | 09.INDICATE THE LOCATION OF EXIT LIGHTS, EMERGENCY | | | LIGHTS, AND FIRE EXTINGUISHER(S). | | | | | | 10.INTERIOR WALL AND CEILING FINISH MATERIAL SHALL BE | | | CLASS A OR CLASS B IN EXITS AND IN EXIT ACCESS | | | CORRIDORS, CLASS A, CLASS B, OR CLASS C IN ALL OTHER | | | AREAS.BE SPECIFIC | | | | | | 11.SEPARATE PLANS AND PERMIT SHALL BE PROVIDED IF THE | | | FIRE SPRINKLER OR FIRE ALARM IS MODIFIED AS A RESULT OF | | | THE SCOPE OF WORK. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE (ON THE PLANS) EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-06-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-23 |
Time |
21:16 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-23 |
Time |
20:26 |
Sent To |
|
|
| Notes |
| 2007-06-23 21:16:16 | *****DENIED***** | | | | | | | | | 01.NFPA 101, THE LIFE SAFETY CODE, 2003 EDITION SHALL | | | BE REFERENCED. | | | | | | 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS | | | SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT | | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 04.THE REMOVAL AND/OR THE STOCKING OF NEW BUILDING | | | MATERIALS & SUPPLIES SHALL NOT INTERFERE OR HINDER WITH | | | EMERGENCY RESPONSE ACCESS TO THE PROPERTY OR VICINITY | | | THEREOF (INCLUDING STREETS, ROADS, FIRE LANES). | | | | | | 05.INDICATE IF THE EXISTING BUILDING OR PORTION | | | THEREOF REPRESENTS A CHANGE OF OCCUPANCY TO A BUSINESS | | | OCCUPANCY.IF SO, THE LIFE SAFETY REQUIREMENTS FOR A | | | NEW BUSINESS OCCUPANCY SHALL APPLY. | | | | | | 06.PLEASE PROVIDE THE OCCUPANT LOAD AS IN THE NUMBER | | | OF PERSONS FOR WHOM MEANS OF EGRESS AND OTHER | | | PROVISIONS ARE REQUIRED. | | | | | | 07.DOORS COMPLYING WITH NFPA 101, 7.2.1 SHALL BE | | | PERMITTED. | | | | | | 08.PLEASE PROVIDE TRAVEL DISTANCE TO EXIT(S). | | | | | | 09.INDICATE THE LOCATION OF EXIT LIGHTS, EMERGENCY | | | LIGHTS, AND FIRE EXTINGUISHER(S). | | | | | | 10.INTERIOR WALL AND CEILING FINISH MATERIAL SHALL BE | | | CLASS A OR CLASS B IN EXITS AND IN EXIT ACCESS | | | CORRIDORS, CLASS A, CLASS B, OR CLASS C IN ALL OTHER | | | AREAS.BE SPECIFIC | | | | | | 11.SEPARATE PLANS AND PERMIT SHALL BE PROVIDED IF THE | | | FIRE SPRINKLER OR FIRE ALARM IS MODIFIED AS A RESULT OF | | | THE SCOPE OF WORK. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE (ON THE PLANS) EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-10 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-10 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2007-08-16 09:47:11 | TO "BOB"#7 | | 2007-08-10 09:52:30 | WAITING FOR BOB BOARD. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-27 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2007-06-12 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2007-06-12 08:25:13 | TO "BOB"#11 | | 2007-06-12 08:17:57 | WAITING FOR"BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-16 |
Time |
10:41 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-08-16 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2007-08-16 10:43:13 | INSTALLING ONE NEW A/C SUPPLY DROP. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-27 |
Time |
09:33 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-06-27 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2007-06-27 09:40:23 | *** DENIED *** | | | 1) PLANS STATE COMBINE TWO EXISTING UNITS. PLANS DO NOT | | | SHOW HOW THE TWO UNITS ARE BEING COMBINED THEY ONLY | | | SHOW HOW ONE UNIT (#207 ? NOT CERTAIN) IS BEING | | | ALTERED. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY. PER 2004 FBC 106.1.1, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-04 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-04 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2007-09-04 09:15:49 | DENIED 2ND TIME | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | ** FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | | MADE ON PREVIOUS REVIEWS. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | | PREVIOUS REVIEW NOTES. | | | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | | | 1. **NO** THIS LOOKS LIKE ONE HALF OF THE 2 UNITS IS | | | TURNING INTO A BUSINESS. THIS WOULD REQUIRE THE | | | BATHROOM OR BATHROOMS TO BE HANDICAP ACCESSIBLE. SEE | | | FBC-2004 EXISTING BUILDING, SECTION 506.1. | | | NOTE: THIS COMMENT WAS NOT ADDRESSED ON THE | | | RESUBMITTAL. IF THERE IS A CHANGE OF OCCUPANCY PLEASE | | | INDICATE THIS ON THE RESUBMITTED PERMIT APPLICATION AS | | | SUCH. PLEASE CLARIFY THIS ON THE RESUBMITTAL. | | | | | | 2. **NO** SHOW ELEVATION DETAIL DRAWINGS WITH ALL THE | | | REQUIRED MEASURMENTS/ INFORMATION TO COMPLY WITH | | | FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILTY CODE SECTIONS | | | 11-4.23.1 THRU 11-4.23.9. | | | NOTE: IF THERE IS A CHANGE OF OCCUPANCY ALL OF THE | | | ABOVE INFORMATION IS REQUIRED. THIS COMMENT WAS NOT | | | ADDRESSED ON THE RESUBMITTAL. | | | | | | 3. **NO** ARE THE LAUNDRY FACILITIES BEING REMOVED? | | | NOTE: IF SHEET 1 OF 6 IS SUPPOSED TO BE A DEMOLITION | | | DRAWING PLEASE INDICATE THE REMOVAL OF THE LAUNDRY | | | FACILITIES ON THE RESUBMITTAL. | | | | | | THE FOLLOWING ARE NEW COMMENTS: | | | | | | 4. IF ONE HALF OF THIS UNIT IS TURNING INTO A BUSINESS | | | A DRINKING FOUNTAIN IS REQUIRED PER FBC-2004, TABLE | | | 403.1, AND SHALL BE ADA ACCESSIBLE PER FBC-2004 CHAPTER | | | 11, SECTION 11-4.15.1 THRU 11-4.15.5 AND SECTION | | | 11-4.1.3(10) INDIVIDUALS WHO HAVE DIFFICULTY BENDING OR | | | STOOPING. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-26 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-26 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2007-06-26 09:20:18 | DENIED; | | | 1. THIS LOOKS LIKE ONE HALF OF THE 2 UNITS IS TURNING | | | INTO A BUSINESS. THIS WOULD REQUIRE THE BATHROOM OR | | | BATHROOMS TO BE HANDICAP ACCESSIBLE. SEE FBC-2004 | | | EXISTING BUILDING SECTION 506.1. | | | 2. SHOW DETAIL DRAWINGS WITH ALL REQUIRED MEASURMENTS | | | TO COMPLY WITH 11-4.23.1 THRU 11-4.23.9. | | | 3. ARE THE LAUNDRY FACILITIES BEING REMOVED? | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-16 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-16 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2007-08-16 16:00:34 | *VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |