Plan Review Details - Permit 07060211
Plan Review Stops For Permit 07060211
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-29 Cont ID  
Sent By mjacobs Date 2007-06-29 Time 16:46 Rev Time 0.00
Received By mjacobs Date 2007-06-29 Time 16:29 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-06-07 Cont ID  
Sent By mjacobs Date 2007-06-07 Time 14:01 Rev Time 0.00
Received By mjacobs Date 2007-06-07 Time 12:43 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-06-21 Cont ID  
Sent By dpalmer Date 2007-06-21 Time 17:57 Rev Time 0.00
Received By dpalmer Date 2007-06-21 Time 17:44 Sent To P
Notes
2007-06-21 17:57:47PLANS ROUTED TO PLUMB AND BLDG AS NEW SHEETS WERE
 SUBMITTED WITH CORRECTIONS AND NEEDS REVIEWERS STAMPS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-07 Cont ID  
Sent By dpalmer Date 2007-06-07 Time 14:25 Rev Time 0.00
Received By dpalmer Date 2007-06-07 Time 14:02 Sent To B
Notes
2007-06-07 14:57:49PLANS ROUTED TO LUIS MARTINEZ
2007-06-07 14:26:52 
 ** UNSAT **
  
 1) NOTE: PLEASE SUBMIT ELECTRICAL WIRING DIAGRAM FOR
 ALL NEW ELECTRICAL PUMP EQUIPMENT, CONDUCTOR SIZES,
 OVER CURRENT PROTECTION, CIRCUIT, PANEL SCHEDULE AND
 LOAD CALCULATIONS.
 310.16,240.4,408.4,220,ETC
 PLEASE SEE 680.50-56
 FBC 106.1.2, 106.3.5
  
 2) NOTE: PLEASE SUBMIT DETAIL FOR UNDER WATER LIGHTING,
 TRANSFORMER, DECK BOX?
 GROUNDING, BONDING ETC AS REQUIRED. 250.50, 680.50-56
 AS NOTED ABOVE IN NOTE #1.
  
 3) NOTE: PLEASE BE SURE THE MOST RECENT ADOPTED CODES
 RELEVANT TO SCOPE OF WORK AND DESIGN IS STATED ON
 PLANS.
 FBC 2004 W/2006 REVISIONS.
 2005 NFPA-70 (NEC).
  
 ** PLANS INDICATE THE 2002 FBC , 2002 NEC AND THE
 *SOUTH FLORIDA BUILDING CODE* WHICH HAS NOT BEEN IN
 EFFECT IN THE STATE OF FLORIDA SINCE THE 2001 FBC WAS
 ADOPTED.
  
 ** REQUIRED WHETHER OR NOT COMMENT IS MADE BY OTHER
 TRADES.
  
 4) NOTE: PLEASE SEE MISSING INFORMATION ON TITLE BLOCKS
 PER FAC 61G15-23.002 AND FS 471.023
 MISSING THE FIRM CERTIFICATE OF AUTHORIZATION NUMBER.
  
 ** REQUIRED WHETHER OR NOT COMMENT IS MADE BY OTHER
 TRADES.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-06-07 Cont ID  
Sent By mperson Date 2007-06-07 Time 10:26 Rev Time 0.00
Received By mperson Date 2007-06-07 Time 10:26 Sent To  
Notes
2007-06-07 10:27:41NOTE: THEFOUNTAIN HAS NO HEATER.
  
 PLANS TO LUIS MARTINEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-20 Cont ID  
Sent By adarroug Date 2007-06-20 Time 11:44 Rev Time 0.00
Received By adarroug Date 2007-06-20 Time 11:44 Sent To Z
Notes
2007-06-20 11:45:00TO "Z" BOX/RESUB--NEW SHEETS ALL TRADES

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-06-29 Cont ID  
Sent By mperson Date 2007-06-29 Time 15:50 Rev Time 0.33
Received By mperson Date 2007-06-29 Time 15:49 Sent To B
Notes
2007-06-29 15:51:37****************PROVISO****************
 IF 1/2" FRESH WATER SUPPLY TO FOUNTAIN #1 IS POTABLE
 WATER IT SHALL BE PROTECTED BY A BACKFLOW PREVENTER PER
 FBC-2004 PLUMBING, SECTION 608.13 AND INSTALLED BY A
 LICENSED PLUMBING CONTRACTOR.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-06-07 Cont ID  
Sent By mperson Date 2007-06-07 Time 10:18 Rev Time 0.33
Received By mperson Date 2007-06-07 Time 10:18 Sent To G
Notes
2007-06-07 10:25:42****************PROVISO****************
 IF 1/2" FRESH WATER SUPPLY TO FOUNTAIN #1 IS POTABLE
 WATER IT SHALL BE PROTECTED BY A BACKFLOW PREVENTER PER
 FBC-2004 PLUMBING, SECTION 608.13 AND INSTALLED BY A
 LICENSED PLUMBING CONTRACTOR.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 2 Status P Date 2007-06-21 Cont ID  
Sent By choops Date 2007-06-21 Time 09:28 Rev Time 0.00
Received By choops Date 2007-06-21 Time 09:28 Sent To E
Notes
2007-06-21 09:28:45RESTAMPED PLANS

Review Stop Z ZONING
Rev No 1 Status P Date 2007-06-06 Cont ID  
Sent By eschneid Date 2007-06-06 Time 17:24 Rev Time 0.00
Received By eschneid Date 2007-06-06 Time 17:24 Sent To I
Notes
***NONE***