Plan Review Details - Permit 07060170
Plan Review Stops For Permit 07060170
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-08-11 Cont ID  
Sent By amorse Date 2007-08-11 Time 16:07 Rev Time 0.00
Received By amorse Date 2007-08-11 Time 16:07 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-24 Cont ID  
Sent By amorse Date 2007-07-24 Time 15:58 Rev Time 0.00
Received By amorse Date 2007-07-24 Time 15:58 Sent To PC
Notes
2007-07-24 16:20:43 
  
 DENIED
  
 1)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME,
 ADDRESS, AND LICENSE NUMBER ON EACH SHEET THAT BEARS
 THEIR SEAL PER 61G15-23.002(2) FAC
  
 2)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*PLEASE NOTE THAT TITLE
 BLOCK INCORRECTLY LISTS 2003 FBC
  
 3)CONSTRUCTION DOCUMENTS SHALL INDICATE THE
 LOCATION/ADDRESS OF THE WORK ALONG WITH A CLEAR
 DEFINITION OF THE PROPOSED WORK. PLEASE NOTE THAT THE
 DRAWING SHALL INDICATE WHICH OF THE MANY SIGN TYPES AND
 SPECIFICATIONS ARE RELEVANT TO THE PERMITTED WORK.
  
 4)CLARIFY THE DISCREPANCY BETWEEN THE SPECIAL PURPOSE
 SURVEY AND THE SPECIFICATIONS/DRAWINGS. DETAIL "A"
 SHOWS SITE POLE OVERALL HEIGHT AT 80'-0" WHICH WOULD
 REQUIRE A 66" X .688" DIAMETER POLE BUT THE SURVEY
 SHOWS A 60" DIAMETER (5'-0") POLE
  
 5)PROVIDE INDEX SHEET WITH THE SPECIFICATIONS THAT
 OUTLINE THE ENGINEERING PAGES THAT APPLY TO THE
 SPECIFIC JOB (IE. COLUMN DESIGN PG. 49, AUGER
 FOUNDATION CALCULATIONS PG. 53 COLUMN #5, ETC.)
  
 6)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006
 AMENDMENTS
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 W/2006 AMENDMENTS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-06-20 Cont ID  
Sent By btrobaug Date 2007-06-20 Time 13:38 Rev Time 0.00
Received By btrobaug Date 2007-06-20 Time 13:25 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-07 Cont ID  
Sent By btrobaug Date 2007-08-07 Time 12:12 Rev Time 0.00
Received By btrobaug Date 2007-08-07 Time 12:12 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-07-24 Time   Rev Time 0.00
Received By adarroug Date 2007-06-20 Time 10:36 Sent To  
Notes
2007-06-20 10:36:49TO "E" BOX

Review Stop Z ZONING
Rev No 3 Status P Date 2007-08-09 Cont ID  
Sent By adavila Date 2007-08-09 Time 08:55 Rev Time 0.00
Received By adavila Date 2007-08-09 Time 08:07 Sent To B
Notes
2007-08-09 08:55:55PER ERIC SCHNEIDER, PRINCIPAL PLANNER
  
 PROVISO FURTHEST PROJECTION POINT OF THE BILLBOARD
 SHALL BE NO LESS THAN 24 FEET FROM THE NORTH PROPERTY
 LINE.THIS SHALL INCLUDE THE CATWALK.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-06-22 Cont ID  
Sent By adavila Date 2007-06-22 Time 15:54 Rev Time 0.00
Received By adavila Date 2007-06-22 Time 14:58 Sent To  
Notes
2007-06-22 15:55:49PER ERIC SCHNEIDER, PRINCIPAL PLANNER
  
 PROVISO FURTHEST PROJECTION POINT OF THE BILLBOARD
 SHALL BE NO LESS THAN 24 FEET FROM THE NORTH PROPERTY
 LINE.THIS SHALL INCLUDE THE CATWALK.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By adavila Date 2007-06-19 Time 17:42 Rev Time 0.00
Received By adavila Date 2007-06-18 Time 17:33 Sent To I
Notes
2007-06-19 17:43:02PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. PROVIDE ALL BILLBOARD STRUCTURE DIMENSIONS IN BOTH
 COPIES OF THE STRUCTURAL DRAWINGS.DIMENSIONS SHOWN IN
 THE STRUCTURAL DRAWINGS SHALL REFLECT DIMENSIONS
 APPROVED IN RESOLUTION NO. 209-07.
 A. PROVIDE OVERALL HEIGHT DIMENSION OF THE PROPOSED
 BILLBOARD STRUCTURE.
 B. PROVIDE WIDTH AND DEPTH DIMENSIONS OF THE FRONT
 CATWALKS.
  
 2. ACCORDING TO THE SIGN CALCULATIONS, THE OVERALL
 HEIGHT OF THE PROPOSED BILLBOARD STRUCTURE WILL BE 120
 FEET.HOWEVER, THE HEIGHT APPROVED IN RESOLUTION NO.
 209-07 IS 65 FEET ABOVE THE CROWN OF INTERSTATE 95,
 WITH AN OVERALL HEIGHT OF 80 FEET.BILLBOARD STRUCTURE
 SIGN CALCULATIONS SHALL REFLECT DIMENSIONS APPROVED IN
 THE RESOLUTION.
  
 3. SURVEY SHALL BE REVISED TO REFLECT SETBACK
 DIMENSIONS APPROVED BY RESOLUTION NO. 209-07.PLEASE
 NOTE THAT SETBACK DIMENSIONS ARE FROM THE PROPERTY LINE
 TO THE FURTHEST PROJECTION POINT OF THE BILLBOARD
 STRUCTURE.PROVIDE SIDE SETBACK DIMENSION FROM THE
 NORTH PROPERTY LINE TO THE FRONT CATWALK.
  
 4. SIGN CALCULATIONS, STRUCTURAL DRAWINGS AND SURVEY
 SHALL REFLECT THE SAME CONDITIONS AS APPROVED IN
 RESOLUTION NO. 209-07.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.