Plan Review Details - Permit 07060170
| Plan Review Stops For Permit 07060170 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-08-11 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-08-11 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-08-11 |
Time |
16:07 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-24 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-07-24 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-07-24 |
Time |
15:58 |
Sent To |
PC |
|
| Notes |
| 2007-07-24 16:20:43 | | | | | | | DENIED | | | | | | 1)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME, | | | ADDRESS, AND LICENSE NUMBER ON EACH SHEET THAT BEARS | | | THEIR SEAL PER 61G15-23.002(2) FAC | | | | | | 2)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL | | | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 | | | AMENDMENTS PER 106.1.1 FBC*PLEASE NOTE THAT TITLE | | | BLOCK INCORRECTLY LISTS 2003 FBC | | | | | | 3)CONSTRUCTION DOCUMENTS SHALL INDICATE THE | | | LOCATION/ADDRESS OF THE WORK ALONG WITH A CLEAR | | | DEFINITION OF THE PROPOSED WORK. PLEASE NOTE THAT THE | | | DRAWING SHALL INDICATE WHICH OF THE MANY SIGN TYPES AND | | | SPECIFICATIONS ARE RELEVANT TO THE PERMITTED WORK. | | | | | | 4)CLARIFY THE DISCREPANCY BETWEEN THE SPECIAL PURPOSE | | | SURVEY AND THE SPECIFICATIONS/DRAWINGS. DETAIL "A" | | | SHOWS SITE POLE OVERALL HEIGHT AT 80'-0" WHICH WOULD | | | REQUIRE A 66" X .688" DIAMETER POLE BUT THE SURVEY | | | SHOWS A 60" DIAMETER (5'-0") POLE | | | | | | 5)PROVIDE INDEX SHEET WITH THE SPECIFICATIONS THAT | | | OUTLINE THE ENGINEERING PAGES THAT APPLY TO THE | | | SPECIFIC JOB (IE. COLUMN DESIGN PG. 49, AUGER | | | FOUNDATION CALCULATIONS PG. 53 COLUMN #5, ETC.) | | | | | | 6)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 | | | AMENDMENTS | | | FBC* = WEST PALM BEACH ADMINISTRATIVE | | | AMENDMENTS TO FBC | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | FS = FLORIDA STATUTES | | | FBC RES. = FLORIDA BUILDING CODE | | | RESIDENTIAL 2004 W/2006 AMENDMENTS | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-20 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-20 |
Time |
13:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-07 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-07 |
Time |
12:12 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-07-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-20 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2007-06-20 10:36:49 | TO "E" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-08-09 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-08-09 |
Time |
08:07 |
Sent To |
B |
|
| Notes |
| 2007-08-09 08:55:55 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER | | | | | | PROVISO FURTHEST PROJECTION POINT OF THE BILLBOARD | | | SHALL BE NO LESS THAN 24 FEET FROM THE NORTH PROPERTY | | | LINE.THIS SHALL INCLUDE THE CATWALK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-06-22 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-06-22 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-06-22 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2007-06-22 15:55:49 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER | | | | | | PROVISO FURTHEST PROJECTION POINT OF THE BILLBOARD | | | SHALL BE NO LESS THAN 24 FEET FROM THE NORTH PROPERTY | | | LINE.THIS SHALL INCLUDE THE CATWALK. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-06-19 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-06-18 |
Time |
17:33 |
Sent To |
I |
|
| Notes |
| 2007-06-19 17:43:02 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. PROVIDE ALL BILLBOARD STRUCTURE DIMENSIONS IN BOTH | | | COPIES OF THE STRUCTURAL DRAWINGS.DIMENSIONS SHOWN IN | | | THE STRUCTURAL DRAWINGS SHALL REFLECT DIMENSIONS | | | APPROVED IN RESOLUTION NO. 209-07. | | | A. PROVIDE OVERALL HEIGHT DIMENSION OF THE PROPOSED | | | BILLBOARD STRUCTURE. | | | B. PROVIDE WIDTH AND DEPTH DIMENSIONS OF THE FRONT | | | CATWALKS. | | | | | | 2. ACCORDING TO THE SIGN CALCULATIONS, THE OVERALL | | | HEIGHT OF THE PROPOSED BILLBOARD STRUCTURE WILL BE 120 | | | FEET.HOWEVER, THE HEIGHT APPROVED IN RESOLUTION NO. | | | 209-07 IS 65 FEET ABOVE THE CROWN OF INTERSTATE 95, | | | WITH AN OVERALL HEIGHT OF 80 FEET.BILLBOARD STRUCTURE | | | SIGN CALCULATIONS SHALL REFLECT DIMENSIONS APPROVED IN | | | THE RESOLUTION. | | | | | | 3. SURVEY SHALL BE REVISED TO REFLECT SETBACK | | | DIMENSIONS APPROVED BY RESOLUTION NO. 209-07.PLEASE | | | NOTE THAT SETBACK DIMENSIONS ARE FROM THE PROPERTY LINE | | | TO THE FURTHEST PROJECTION POINT OF THE BILLBOARD | | | STRUCTURE.PROVIDE SIDE SETBACK DIMENSION FROM THE | | | NORTH PROPERTY LINE TO THE FRONT CATWALK. | | | | | | 4. SIGN CALCULATIONS, STRUCTURAL DRAWINGS AND SURVEY | | | SHALL REFLECT THE SAME CONDITIONS AS APPROVED IN | | | RESOLUTION NO. 209-07. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |