Plan Review Details - Permit 07060160
Plan Review Stops For Permit 07060160
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-07-31 Cont ID  
Sent By shill Date 2007-07-31 Time 18:42 Rev Time 0.00
Received By shill Date 2007-07-31 Time 18:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-07-12 Cont ID  
Sent By shill Date 2007-07-12 Time 14:15 Rev Time 0.00
Received By shill Date 2007-07-12 Time 14:15 Sent To  
Notes
2007-07-12 14:17:47****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)FOUR SETS OF PRODUCT APPROVALS ARE IN THE PACKAGE.
 TWO REQUIRED.PLEASE SUBMIT TWO IDENTICAL COLLATED
 SETS FOR PERMIT ISSUANCE.OLD SHEETS CAN BE MARKED
 "VOID" AND SUBMITTED SEPARATELY.
  
 2.)FOR A DESIGN PRESSURE OF -72, USE THE -73 ROW.
 INCORRECT ROW WAS HIGHLIGHTED ALTHOUGH MOST OF THE
 OPENINGS SPECIFY CORRECT ANCHOR SPACING.
  
 3.0OPENING 7, C4,3" SPACING REQUIRED.IT IS NOT
 CLEAR WHY THE TOP AND BOTTOM HAVE DIFFERENT ANCHOR
 SPACING WITH THE SAME CONNECTION TYPE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By shill Date 2007-06-19 Time 10:02 Rev Time 0.00
Received By shill Date 2007-06-19 Time 10:02 Sent To  
Notes
2007-06-19 10:03:29****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-23 Cont ID  
Sent By adarroug Date 2007-07-23 Time 09:10 Rev Time 0.00
Received By adarroug Date 2007-07-23 Time 09:10 Sent To B
Notes
2007-07-23 09:11:14TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-07-06 Cont ID  
Sent By adarroug Date 2007-07-06 Time 11:03 Rev Time 0.00
Received By adarroug Date 2007-07-06 Time 11:03 Sent To B
Notes
2007-07-06 11:03:58TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-19 Cont ID  
Sent By shill Date 2007-06-19 Time 10:03 Rev Time 0.00
Received By shill Date 2007-06-07 Time 11:28 Sent To  
Notes
2007-06-07 11:28:22TO "MISC" BOX#1