Plan Review Details - Permit 07060056
| Plan Review Stops For Permit 07060056 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-21 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-21 |
Time |
14:01 |
Sent To |
PC |
|
| Notes |
| 2007-09-21 14:06:54 | REVISION: LAYOUT CHANGED & DELIVERY PRESSURE INCREASED | | | TO 2 PSI. | | | | | | ****************PROVISO**************** | | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | | INGS REQUIRED PER SECTION 304.5 OR | | | SECTION 304.6 SHALL BE INSTALLED. | | | MINIMUM 1,100 CUBIC FEET REQUIRED. | | | | | | IF WATER HEATER ROOM IS A CONFINED | | | SPACE, OPENINGS REQUIRED PER SECTION | | | 304.5 OR SECTION 304.6 SHALL BE | | | INSTALLED. | | | MINIMUM 2,500 CUBIC FEET REQUIRED. | | | | | | POOL HEATER WITH POOL PERMT #07041051: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-20 |
Time |
08:03 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-08-20 |
Time |
08:03 |
Sent To |
PC |
|
| Notes |
| 2007-08-20 08:15:02 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | THE GAS REVISION FOR PLAN REVIEW TO MEET CODE | | | COMPLIANCE: | | | | | | 1. THE REVISED GAS ISOMERIC DOES NOT NOT INDICATE ALL | | | THE CORRESPONDING LENGTHS OF THE INDICATED CUT SECTIONS | | | OF PIPE. PLEASE CORRECT AND RESUBMIT. | | | | | | 2. THE REVISED GAS ISOMETRIC DOES NOT INDICATE THE | | | ABOVE GROUND PIPING MATERIAL. PLEASE CORRECT AND | | | RESUBMIT. | | | | | | 3. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | NOTE: IN ORDER TO VERIFY THIS ALL THE CORRESPONDING | | | LENGTHS OF THE CUT SECTIONS OF PIPE MUST BE INDICATED | | | ON THE GAS REVISION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-27 |
Time |
14:13 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-06-27 |
Time |
14:13 |
Sent To |
PC |
|
| Notes |
| 2007-06-27 14:16:03 | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | | INGS REQUIRED PER SECTION 304.5 OR | | | SECTION 304.6 SHALL BE INSTALLED. | | | MINIMUM 1,100 CUBIC FEET REQUIRED. | | | | | | IF WATER HEATER ROOM IS A CONFINED | | | SPACE, OPENINGS REQUIRED PER SECTION | | | 304.5 OR SECTION 304.6 SHALL BE | | | INSTALLED. | | | MINIMUM 2,500 CUBIC FEET REQUIRED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-29 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-29 |
Time |
15:54 |
Sent To |
G |
|
| Notes |
| 2007-08-29 15:55:01 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-15 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-15 |
Time |
10:02 |
Sent To |
G |
|
| Notes |
| 2007-08-15 10:02:43 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-27 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-06-06 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2007-06-06 09:02:21 | TO "G" BOX |
|
|
|