| 2007-08-27 11:55:07 | |
| | |
| 2007-06-22 10:47:03 | |
| | |
| | |
| | |
| | IRON MOUNTAIN- FOUNDATION ONLY |
| | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07051157 |
| | ADD: 3501 ELECTRONIC WAY |
| | CONT: EDWARDS CONSTRUCTION SERVICES |
| | TEL: (352)854-6266 |
| | |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2 ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. |
| | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLY |
| | COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, |
| | SUCH NOTICE IS NULL & VOID. |
| | NOTE: 713.13(6)THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION |
| | SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) PLEASE TAKE NOTE OF SURVEY FROM GT SURVEYING HAS A |
| | RAISED SEAL BUT A PHOTO-COPIED SIGNATURE. SEE FLORIDA |
| | ADMINISTRATIVE CODE 61G17 AND FL S S 472.025 ABOUT |
| | ORIGINAL SIGNATURES. |
| | |
| | 4) PLEASE TAKE NOTE THAT ARCHITECTURAL ALLIANCE, INC. |
| | LOST THEIR CERTIFICATE OF AUTHORIZATION 2-28-2001. SEE |
| | ATTACHMENT FROM THE DPBR WEBSITE. |
| | |
| | 5) CS-1 PLAN REVIEW DATA INDICATES THE PLAN WAS |
| | DESIGNED TO THE 2004 FBC PLEASE SEE PLAN AS SUBMITTED |
| | AFTER DEC.8TH, 2006 ARE TO BE REVIEWED UNDER THE 2006 |
| | FBC. |
| | |
| | 6) CS-1 PLAN REVIEW DATA DECLARES THIS BUILDING AS A |
| | IIB BUILDING UNPROTECTED (1 STORY) FULLY SPRINKLED, |
| | NOTE THE COMMENTFOR UNLIMITED AREA FOR TYPE II |
| | BUILDINGS S OCCUPANCIES FOR FULLY SPRINKLED BUILDINGS |
| | FBC 507.2REQUIRES A 60'-0"CLEARANCE, WHICH THIS |
| | BUILDING DOES NOT HAVE. 507.4 DOES PROVIDE FOR REDUCED |
| | OPEN SPACE REQUIREMENTS BUT THE EXISTING BUILDING IS |
| | 21.29' AWAY FROM THE PROPERTY LINE. PLEASE PROVIDE |
| | INCREASES FOR SPRINKLERS, ONE STORY AND ANY AREA |
| | INCREASES THAT CAN BE TAKEN PROVIDE CALCULATIONS FOR |
| | AREA MODIFICATIONS ON THE PLAN. TOTAL SQ FT UNDER TYPE |
| | II-B UNPROTECTED (S-1) IS 17,500 SQ FT. |
| | |
| | 7)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 8)THE CONTRACTOR HAS ELECTED TO APPLY FOR A |
| | FOUNDATION PERMIT, THE DETAIL SHEET S-3 INDICATES THIS |
| | TO BE A MONOLITHIC SLAB, AS DRAWN THE ELECTRICAL WILL |
| | NEED TO SEE COMPLIANCE WITH THE GROUNDING ELECTRODE |
| | SYSTEM REQUIRING AN ELECTRICAL PERMIT. |
| | |
| | 9) THIS IS A COMPLETELY SEPARATE BUILDING FROM THE |
| | BUILDING IN FRONT, SO THERE WOULD ALSO NEED TO BE A |
| | RISER FOR THE FIRE SPRINKLERS PENETRATING THE |
| | MONOLITHIC SLAB.THE SAME MAY HOLD TRUE FOR PLUMBING |
| | AND MECHANICAL |
| | |
| | 10PROVISO: THE SOILS REPORT ALSO INDICATES AREAS OF |
| | ORGANIC CONTENT. PROVIDE FROM THE SOILS ENGINEERS |
| | REPORTS FOR THE REMOVAL AND COMPACTION OF THE LIFTS TO |
| | THE SOILS ENGINEERS RECOMMENDATIONS. |
| | |
| | 11PROVISO:109.3.10* IMPACT OF CONSTRUCTION. ALL |
| | CONSTRUCTION ACTIVITY REGULATED BY |
| | THIS CODE SHALL BE PREFORMED IN A MANNER SO AS NOT TO |
| | ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY, |
| | UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT SAID |
| | PROPERTY PURSUANT TO A CONSENT BY THE APPLICABLE |
| | PROPERTY OWNER, UNDER TERMS & CONDITIONS AGREEABLE TO |
| | THE |
| | APPLICABLE PROPERTY OWNER. THIS INCLUDES BUT IS NOT |
| | LIMITED TO THE CONTROL OF DUST, NOISE, WATER OR |
| | DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF |
| | CONSTRUCTION MATERIALS. NEWCONSTRUCTION ACTIVITY |
| | SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE WATER |
| | DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY |
| | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH |
| | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS |
| | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, |
| | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL |
| | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, |
| | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| | PROPERTIESRESULTING IN A DECREASE IN EXCESS OF 800SQ |
| | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL |
| | AS A PERMIT CONDITION, PROVIDE A PROFESSIONALLY |
| | PREPARED DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE |
| | WITH THIS PARAGRAPH. UPON COMPLETION OF THE |
| | IMPROVEMENT, A CERTIFICATE FROM A LICENSED ENGINEER |
| | SHALL BE SUBMITTED TO THE INSPECTOR IN ORDER TO RECEIVE |
| | APPROVAL OF THE FINAL INSPECTION. |
| | |
| | 12 PROVISO: 109.3.10.1 HURRICANE PROTECTION. IT SHALL |
| | BE UNLAWFUL FOR ANY PERSON TO ALLOWCONSTRUCTION |
| | RELATED MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE |
| | OR OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 |
| | HRS. AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE |
| | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH |
| | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS SHALL BE |
| | EITHER REMOVED FROM THE CONSTRUCTION SITE OR SECURED IN |
| | SUCH A MANNER AS TO MINIMIZE THE DANGER OF SUCH |
| | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS CAUSING |
| | DAMAGE TO PERSONS OR PROPERTY FROM HIGH WINDS. ANY |
| | PERSONS WHO FAILS TO COMPLY TO REMOVE OR SECURE THE |
| | CONSTRUCTION MATERIALS EQUIPMENT AND DEBRIS WITHIN |
| | 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE |
| | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION |
| | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS |
| | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO |
| | SECTION 113 OF THIS CHAPTER. |
| | |
| | 13 BUILDING PROVISO: 105.13. SPECIAL FOUNDATION PERMIT |
| | WHEN APPLICATION FOR A PERMIT TO ERECT OR ENLARGE A |
| | BUILDING HAS BEEN FILED, & PENDING ISSUANCE OF SUCH |
| | PERMIT, THE BUILDING OFFICIAL MAY, AT HIS/ HER |
| | DISCRETION, ISSUE A SPECIAL PERMIT FOR THE FOUNDATION |
| | ONLY, UPON WRITTEN REQUEST OF THE OWNER AND CONTRACTOR. |
| | THE |
| | HOLDER OF SUCH A SPECIAL PERMIT IS PROCEEDING AT HIS OR |
| | HER OWN RISK AND WITH OUT ASSURANCE THAT A PERMIT FOR |
| | THE REMAINDER OF THE WORK WILL BE GRANTED AND THAT |
| | CORRECTIONS WILL NOT BE REQUIRED IN ORDER TO MEET THE |
| | PROVISIONS OF THE TECHNICAL CODE. |
| | |
| | 14 BUILDING PROVISO: THIS IS AT MINIMUM TYPE II-B |
| | BUILDING WHICH NORMALLY WOULD REQUIRE A RESIDENT |
| | INSPECTOR BY THE CITY?S ADMINISTRATIVE CODE 109.3.7(1), |
| | AT THIS TIME THE |
| | INSPECTION SERVICES MANAGER HAROLD PISKURA HAS DEEM IT |
| | UNNECESSARY. IF PROBLEMS DO OCCUR DURING THE TIME OF |
| | CONSTRUCTION THE CITY MAY ELECT TO HAVE SUCH INSPECTOR |
| | ON SITE. |
| | |
| | BUILDING PLAN REVIEW II |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |