Plan Review Details - Permit 07051134
Plan Review Stops For Permit 07051134
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2008-10-24 Cont ID  
Sent By shill Date 2008-10-24 Time 08:59 Rev Time 0.00
Received By shill Date 2008-10-24 Time 08:59 Sent To  
Notes
2008-10-24 09:00:00REVISION, A/C STANDS AND WALL LOUVERS
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2008-10-24 Cont ID  
Sent By shill Date 2008-10-24 Time 08:50 Rev Time 0.00
Received By shill Date 2008-10-24 Time 08:50 Sent To  
Notes
2008-10-24 08:52:06****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
  
 1. SEE PREVIOUS BUILDING REVIEW. THE REVISION SUBMITTED
 WAS DENIED WITH A REQUEST FOR AN UPDATED VALUE FOR THIS
 JOB. PLEASE PROVIDE. THIS MAY BE DONE OVER THE
 TELEPHONE, AND FEES CAN BE PAID ONLINE.
  
  
 **NOTE - I DID THIS REVIEW PER RR REQUEST**
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2008-10-06 Cont ID  
Sent By mjacobs Date 2008-10-06 Time 11:06 Rev Time 0.00
Received By mjacobs Date 2008-10-06 Time 11:06 Sent To  
Notes
2008-10-06 11:06:12BUILDING PLAN REVIEW
 PERMIT: 07051134
 ADD: 7816 S. OLIVE AVE
 CONT: S. GROUP INC.
 TEL: (561)688-2295
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 1ST
 ACTION: DENIED
  
 1) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE & REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) THERE SEEMS TO BE SIGNIFICANT AMOUNT OF CHANGES TO
 THE PROJECT, PLEASE INDICATE THE ADDITIONAL VALUE FOR
 ALL THE ADDITIONAL WORK INVOLVED AT THE PROJECT.
 106.1.2* ADDITIONAL INFORMATION IS REQUIRED.
  
 3) IF THE MECHANICAL UNITS WILL BE LOCATED ON THE ROOF,
 THEY SHALL BE RAISED A MINIMUM OF 8 INCHES ABOVE THE
 ROOF: AND MEET THE REQUIREMENTS OF FBC 1509.7 AND TABLE
 1509.7. 106.3.3* PRODUCT APPROVALS- 2004 (MECHANICAL
 UNIT STANDS) THOSE PRODUCTS THAT ARE REGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 NOTE: ADDITIONAL SHEETS ARE REQUIRED SHOWING THE
 CHANGES TO THE MECHANICAL AND ELECTRICAL SYSTEMS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2008-09-26 Cont ID  
Sent By mjacobs Date 2008-09-26 Time 10:23 Rev Time 0.00
Received By mjacobs Date 2008-09-26 Time 09:48 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-02-12 Cont ID  
Sent By mjacobs Date 2008-02-12 Time 09:16 Rev Time 0.00
Received By mjacobs Date 2008-02-11 Time 13:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-09-27 Cont ID  
Sent By mjacobs Date 2007-09-27 Time 10:17 Rev Time 0.00
Received By mjacobs Date 2007-09-26 Time 17:38 Sent To  
Notes
2007-09-27 10:17:33 
  
  
  
 BUILDING PLAN REVIEW
 PERMIT: 07051134
 ADD: 7816 S. DIXIE HWY
 CONT: S GROUP INC.
 TEL: (561)688-2295
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) OK
 3) OK
  
 4)SUBMIT A WALL TYPE DETAIL SHEET FOR EACH TYPE OF
 WALL TO BE CONSTRUCTED.
 *****HOWEVER*****
 ON SHEET A-4 THE WALL SCHEDULE NEEDS TO BE MORE
 SPECIFIC. DETAIL B SHOWS A METAL STUD WITH PRESSURE
 TREATED 2X6 BASE PLATES. HOW WILL THE METAL STUD BE
 CONNECTED TO THE 2X6 PLATES?IF THERE ARE THREE
 DIFFERENT SIZE WALLS, EACH ONE SHALL HAVE ITS OWN
 DETAIL.
  
 5)OK
  
 6)ON THE PRODUCT CIRCLE OR HI-LIGHT WHICH ITEM WILL
 BE USED. INDICATE THE SIZE OF EACH WINDOW OPENING TO BE
 USED FROM THE PRODUCT APPROVAL. SUBMIT THE PRODUCT
 APPROVAL FOR THE WINDOW MULLIONS.
 **NO RESPONSE NOT ADDRESSED** THE PRODUCT APPROVAL FOR
 THE DOUBLE METAL DOOR # (1) IS REQUIRED.
 **NEW**
 (A) THE WALL LAYOUT ON SHEET A-4 DOES NOT CORRESPOND
 WITH THE LAYOUT ON M SHEETS. THE LOCATIONS OF THE AHU
 ROOMS ARE IN DIFFERENT LOCATIONS ON DIFFERENT SEE
 SHEETS M1 AND M2. ON SHEET M1 AHU ROOM #1 AND #2 ARE
 SHOWN IN DIFFERENT LOCATIONS ON SHEET AE-8.THE
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED. FBC.106.1.1.
  
 (B)ON SHEET A-3 THE EXISTING FLOOR PLAN INDICATE THAT
 SOME WALLS WILL BE RE-BLOCK, HOWEVER, ON SHEET A-4 THE
 SAME WALLS ARE SHOWN BEING FRAMED WITH METAL STUDS OR
 WOOD. CLARIFY.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected].

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-28 Cont ID  
Sent By mjacobs Date 2007-06-28 Time 11:00 Rev Time 0.00
Received By mjacobs Date 2007-06-27 Time 18:49 Sent To  
Notes
2007-06-27 19:00:12BUILDING PLAN REVIEW
 PERMIT: 07051134
 ADD: 7816 S. DIXIE HWY
 CONT: S GROUP INC.
 TEL: (561)688-2295
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)FBC 11-4.24.THE BREAK ROOM SINK SHALL MEET THE
 REQUIREMENTS OF THIS SECTION. SHOW THE ELEVATION
 DETAILS INDICATING THE HEIGHT/ KNEE CLEARANCE/ DEPTH OF
 THE SINK / THE CLEAR FLOOR SPACE AND FORWARD APPROACH.
  
 3) STATE WHAT WILL BE STORED IN THE STORAGE AREA. WILL
 THERE BE ANY DOOR ON THE STORAGE SECTION?
  
 4)SUBMIT A WALL TYPE DETAIL SHEET FOR EACH TYPE OF
 WALL TO BE CONSTRUCTED.
  
 5)FBC. 1210.2WALL WITHIN 2 FEET OF UNIRALS AND
 WATER CLOSETS SHALL HAVE A SMOOTH, "HARD", NONABSORBENT
 SURFACE, TO HEIGHT OF 4 FEET ABOVE THE FLOOR, SHOW HOW
 THE BATHROOM WALLS WILL MEET THIS REQUIREMENTS.
  
 5)ON THE PRODUCT CIRCLE OR HI-LIGHT WHICH ITEM WILL
 BE USED. INDICATE THE SIZE OF EACH WINDOWOPENING TO
 BE USED FROM THE PRODUCT APPROVAL. SUBMIT THE PRODUCT
 APPROVAL FOR THE WINDOW MULLIONS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 [email protected].

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2008-10-21 Cont ID  
Sent By dpalmer Date 2008-10-21 Time 13:03 Rev Time 0.00
Received By dpalmer Date 2008-10-21 Time 13:03 Sent To  
Notes
2008-10-21 13:03:47 
 ** DENIED REVISION**
  
  
  
  
 1) NOTE: PLEASE SEE ELECTRICAL PLANS AS SUBMITTED DO
 NOT INDICATE ANY REVISIONS IN TITLE BLOCKS. IN FACT THE
 LAST REVISION NOTED IN THE TITLE BLOCKS WAS FROM
 4/25/07.
 PLEASE SEE THE SHEET E-1 AND 3 WHICH DO NOT INDICATE
 ANY REVISIONS.
 SHEET E-2 SHOW DIFFERENT LIGHT FIXTURES HOWEVER NO
 CHANGES OR REVISIONS TO TITLE BLOCKS OR PLANS.
 PLEASE BE SURE ANY LIGHTING PERFORMANCE CALCULATIONS
 ARE ALSO UPDATED BASED ON THE NEW FIXTURES.
 13-415.2,13-415.2.ABC.1.1, .1.2.
 FBC 106.5, 106.1.1, FOR COORDINATION OF RECORD PLANS.
  
 ** PLEASE ONLY SUBMIT SHEETS BEING REVISED. IF NO
 REVISIONS HAVE BEEN MADE, THER IS NO NEED TO SUBMIT NEW
 SHEETS.
  
  
  
  
  
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
  
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2008-10-06 Cont ID  
Sent By dpalmer Date 2008-10-06 Time 16:31 Rev Time 0.00
Received By dpalmer Date 2008-10-06 Time 16:31 Sent To  
Notes
2008-10-06 16:31:30** DENIED REVIEW **
  
 1) NOTE: ARCHITECTURAL REFLECTED CEILING PLANS HAVE
 SUBSTANTIALLY BEEN REVISED TO A NEW DROP CEILING WITH
 RECESSED TYPE FIXTURES INCLUDING CHANGES IN FIXTURES AS
 WELL AS THE NUMBER OF FIXTURES.
 PLEASE SUBMIT COMPLETE REVISED ELECTRICAL PLANS.
  
 **IMPORTANT**
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO
 TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-02-09 Cont ID  
Sent By dpalmer Date 2008-02-09 Time 08:51 Rev Time 0.00
Received By dpalmer Date 2008-02-09 Time 08:51 Sent To  
Notes
2008-02-11 08:52:33**PROVISO **
  
 1) NOTE: PLEASE SUBMIT REVISED FIXTURE LEGEND WHICH
 STATES THE SPECIFIC FIXTURES.
 PLEASE ALSO KNOW AS NO FIXTURE INFORMATION WAS
 SUBMITTED FOR EXTERIOR LIGHTING AND NONE WERE SHOWN ON
 PLANS, ANY INSTALLATION OF EXTERIOR LIGHTING WILL
 REQUIRE BOTH PLANS AND CALCULATIONS TO BE UPDATED.
 AS METHOD *A* WAS SUBMITTED FOR COMPLIANCE, ALL OTHER
 ASPECTS OF BUILDING CONSTRUCTION FOR COMPLIANCE WITH
 METHOD A WILL STILL NEED TO BE REVIEWED BY OTHER
 TRADES.
  
 13-400.3.A, 13-415.1.A, 13-415.2,
 FBC 106.1.2, 106.3.5.1.2
 FAC 61G15-33.004
  
 ** IMPORTANT**
 WHEN CONTACTING THIS OFFICE/REVIEWER, PLEASE LEAVE A
 MESSAGE. IF A MESSAGE WITH CONTACT INFORMATION IS NOT
 LEFT ON VOICEMAIL IT IS NOT POSSIBLE TO RETURN A CALL.
 THIS IS IN RESPONSE TO LETTER SUBMITTED BY MECHANICAL
 DESIGNER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-09-21 Cont ID  
Sent By dpalmer Date 2007-09-21 Time 15:39 Rev Time 0.00
Received By dpalmer Date 2007-09-21 Time 15:39 Sent To  
Notes
2007-09-21 15:39:25 
 ** DENIED 2ND REVIEW **
  
 ** PLEASE SEE SOME NOTE(S) FROM PREVIOUS REVIEW ARE
 STILL IN NEED OF ADDRESSING.
  
 1) NOTE: PLEASE SEE PREVIOUS NOTE #2 WITH RESPECT TO
 THE ENERGY CALCULATIONS AND COORDINATION WITH PLANS.
 PLEASE SEE FIXTURE *A* FOR EXAMPLE WHICH IS SHOWN AS
 128 TOTAL WATTS ON FIXTURE LEGEND ON PLANS, YET IT
 SEEMS THIS SAME FIXTURE IN STORAGE AREA IS PLACED ON
 THE INPUT DATA REPORT AS 100WATTS.
 PLEASE SEE FIXTURE LEGEND FOR TYPE *A*.
 PLEASE ALSO SEE THE ELECTRICAL PLANS INCLUDE AN
 ELECTRICAL WATER HEATER YET THERE IS NONE ENTERED ON
 THE CALCULATIONS.
 **PLEASE SEE THE OWNER AGENT IS STILL NOT SIGNED.
 **PLEASE SEE MECHANICAL REVIEW COMMENTS FOR THE METHOD
 BEING USED. SUBMITTED AS *A* FOR AN EXISTING BUILDING?
  
 ** THE ELECTRICAL PLANS ARE OK.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW.
  
 PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-23 Cont ID  
Sent By dpalmer Date 2007-06-23 Time 20:44 Rev Time 0.00
Received By dpalmer Date 2007-06-23 Time 19:48 Sent To  
Notes
2007-06-23 20:44:42*** UNSAT ***
  
  
 1) NOTE:PLEASE KNOW THAT ANY PERMIT APPLICATIONS
 WHICH ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES
 PROJECTS UNDER THE NEW CODES ADOPTED BY THE STATE.
 PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO
 THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70.
 PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY
 AFFECT DESIGNS FOR ALL TRADES.
 PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS
 REVIEWER AT A MINIMUM.
 2004 FBC W/ 2006 REVISIONS
 2005 NFPA-70
 2002 NFPA-72
 2003 NFPA-101
  
 ** PLEASE KNOW THAT CHANGES FOR NEW CODES IS REQUIRED
 FOR ALL TRADES AND FOR ALL REVIEWS EVEN IF COMMENT IS
 NOT MADE BY OTHER TRADE(S).
  
 2) NOTE: PLEASE SEE THE VERSION OF THE ENERGY
 CALCULATIONS IS NOT CORRECT. PLEASE BE SURE TO SEE THE
 FLA-COM EFFECTIVE DATE DECEMBER 8TH, 2006 WHICH SHOULD
 READ VERSION 3.0.
 PLEASE SEE THERE IS A CONFLICT IN THE CODE AS THE 2004
 FBC W/2006 REVISIONS STATES VERSION 2.5. CONTACT HAS
 BEEN MADE TO THE STATE FOR THIS CONFLICT AND THE STATE
 HAS INFORMED THIS AHJ THE VERSION 3.0 SHOULD BE USED.
 PLEASE SEE THE ENERGY CALCULATIONS DO NOT MATCH WITH
 THE PLANS SUBMITTED.
 PLEASE SEE THE TYPE OF FIXTURES DOES NOT MATCH.
 PLEASE SEE THE NUMBER OF LUMINARIES DOES NOT MATCH.
 PLEASE SEE THE WATTAGE FOR LUMINARIES DOES NOT MATCH.
 PLEASE SEE THE TOTAL DO NO MATCH.
 PLEASE SEE THE FIGURES SHOWN FOR EXTERIOR LIGHTING DO
 NOT MATCH WITH PLANS.
 PLEASE SEE THE METHOD OF CONTROL WHICH IS SHOWN AS
 *MANUAL ON/OFF DOES NOT MATCH.
 PLEASE COORDINATE ALL OF THESE ITEMS WITH ELECTRICAL
 PLANS.
 PLEASE SEE 13-415.1.AB.1.1 ETC.
 PLEASE SEE THE OWNER AGENT IS NOT SIGNED ON SHEETS.
 PLEASE SEE THE COVER SHEET ATTACHED WITH THE COLOR
 PHOTO-COPY OF THE PERSON RESPONSIBLE FOR THE ENERGY
 CALCULATIONS HAS BEEN REMOVED.MUST BE ORIGINAL AND ON
 THE ENERGY CALCULATIONS AS SUBMITTED.
 PLEASE SEE THE SECOND SHEET OF THE ENERGY CALCULATIONS
 SHALL BEAR THE PRINTED NAME, SIGNATURE, AND LICENSE
 INFORMATION IF QUALIFYING UNDER FS 489 AND EXEMPTIONS
 UNDER FS 481.229, 471.003.
 PLEASE SEE INFORMATION FOR THE ELECTRICAL ENGINEER IS
 NOT LISTED.
 13-103.1.1.1
 PLEASE PROVIDE A TYPICAL DETAIL FOR THE OS CONNECTIONS
 INCLUDING DETAIL FOR TIE IN OF EMERGENCY/EXIT LIGHTING
 (700.12F). THIS CAN BE THE SAME DETAIL.
  
 3) NOTE: PLEASE SEE PLANS AS THERE APPEARS TO LIGHTING
 FIXTURES ON PLANS WHICH DO NOT SHOW THE TYPE,
 CIRCUITING, CONTROL ETC.
 PLEASE COMPLETE.
 FBC 106.1.2
 NEC, 240.4,310.16, FBC CHAPTER 13 ETC.
  
 4) NOTE: PLEASE CORRELATE A/C LOADS WITH THE MECHANICAL
 PLANSOR MECHANICAL TO COORDINATE WITH ELECTRICAL.
 PLEASE SEE THE LOADS FOR HEAT DO NOT MATCH AND IF USING
 THE LOADS ON MECHANICAL PLANS THE LOADS ON THE
 ELECTRICAL PLANS WILL SUBSTANTIALLY CHANGE. PLEASE
 REVISE LOAD CALCULATIONS, PLEASE REVISE CONDUCTORS,
 PLEASE REVIEW OVER CURRENT PROTECTION DEVICES ETC.
 PLEASE SEE AHU #1 WHICH SHOWS 5KW ON ONE PHASE AND
 APPEARS TO MISPRINT 500KVA ON THE SECOND PHASE. (PANEL
 SCHEDULE).
 240.4, 310.16, 424.3B, 220.
  
 5) NOTE: PLEASE SEE THAT BASED ON THE FIXTURES SHOWN ON
 PLANS AND FIXTURES IN BATHROOM, THE LIGHTING LEGEND
 ALONG WITH ENERGY CALCULATIONS ETC WILL NEED TO BE
 ADJUSTED AND UPDATED.
 FBC 106.1.2
  
 6) NOTE: PLEASE SEE THERE ARE RECEPTACLES ON PLANS
 WHICH DO NOT SHOW CIRCUITING TO THEM. PLEASE COMPLETE
 ALL CIRCUITING. PLEASE SEE ONE SET HAS SOME OF THESE
 REDLINED AT LOCATIONS.
  
 7) NOTE: PLEASE SEE SPACING FOR THE SHOW WINDOW
 RECEPTACLES. PLEASE SEE 210.62 AS THE LENGTHS OF THE
 WINDOWS EXCEED 12FT WHICH WOULD REQUIRE ONE ADDITIONAL
 RECEPTACLE AT EACH LOCATION.
 PLEASE BE SURE TO ADJUST ANY LOADS AS NEEDED. PLEASE
 SEE LOAD CALCULATIONS AS THE LOAD SHOWN MENTIONS 33 FT
 FOR THE TOTAL, HOWEVER BASED ON THE SCALE, THE LINEAR
 FT DOES NOT CORRELATE.
 PLEASE ADJUST.
  
 8) NOTE: PLEASE STATE THE TYPE OF STORAGE AND ITEMS
 BEING SOLD (IF KNOWN AT THIS TIME). PLEASE SEE NEC 500
 IF NEEDED.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status F Date 2008-10-27 Cont ID  
Sent By mawillia Date 2008-10-27 Time 15:44 Rev Time 0.00
Received By mawillia Date 2008-10-27 Time 15:24 Sent To  
Notes
2008-10-27 15:39:33FIRE STAMP NEEDED
  
 THE APPROPIATE REVISED PLAN SHEET TO BE FIRE-STAMPED
 WHEN THE OTHER REVIEWERS COMMENTS HAVE BEEN ADDRESSED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2008-02-28 Cont ID  
Sent By mawillia Date 2008-02-28 Time 19:00 Rev Time 0.00
Received By mawillia Date 2008-02-28 Time 18:49 Sent To  
Notes
2008-02-28 18:58:43*****RESTAMPED*****
  
 PREVIOUSLY APPROVED ON 10/23/07;PLAN SHEETS A-4,
 A-5, AND AE-8 WERE RE-STAMPED, INITIALED, AND DATED.
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-10-23 Cont ID  
Sent By mawillia Date 2007-10-23 Time 14:22 Rev Time 0.00
Received By mawillia Date 2007-10-23 Time 12:36 Sent To  
Notes
2007-10-23 14:22:39*****APPROVED*****
  
 THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED;PLAN SHEETS A-4, A-5, AND AE-8 WERE
 STAMPED, INITIALED, AND DATED.
  
  
  
  
  
  
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-07-17 Cont ID  
Sent By mawillia Date 2007-07-17 Time 13:32 Rev Time 0.00
Received By mawillia Date 2007-07-17 Time 13:02 Sent To  
Notes
2007-07-17 13:31:19*****DENIED*****
  
  
  
 01.PLEASE INDICATE WHAT THE EXISTING OCCUPANCY IS AND
 WHAT THE NEW OCCUPANCY WILL BE.
  
 02.NFPA 101 - 2003 EDITION SHALL BE REFERENCED.
  
 03.ON THE APPROPIATE EXTERIOR ELEVATION WHICH FRONTS
 SOUTH DIXIE HIGHWAY, POST THE NUMERICAL ADDRESS ON THE
 BUILDING. AS PER WEST PALM BEACH CODE, THESE NUMBERS
 SHALL BE NO LESS THAN 6" IN HEIGHT AND NO LESS THAN 1"
 IN WIDTH.
  
 04.BASED UPON THE COMPASS AND SITE PLAN ON DRAWING
 NUMBER AS-1, THE FRONT ELEVATION WOULD APPEAR TO BE THE
 WEST ELEVATION WHEREAS DRAWING NUMBER A-5 HAS THE FRONT
 ELEVATION AS THE NORTH ELEVATION.PLEASE CORRELATE.
  
 05.ON DRAWING NUMBER AE-8, PLEASE EXPLAIN THE
 COMBINATION EXIT/EMERGENCY LIGHT WHICH LEADS PERSON(S)
 BACK INTO A COMPARTMENTALIZED AREA.
  
 06.ON DRAWING NUMBER AE-9, THE NUMBER OF COMBINATION
 EMERGENCY-EXIT LIGHTS AND EMERGENCY LIGHT LISTED IN THE
 LIGHTING FIXTURE SCHEDULE DO NOT CORRELATE TO THE
 AMOUNT OF DEVICES SHOWN ON DRAWING NUMBER AE-8.
  
 07.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE.
  
  
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-10-16 Cont ID  
Sent By adarroug Date 2008-10-16 Time 09:01 Rev Time 0.00
Received By adarroug Date 2008-10-16 Time 09:01 Sent To  
Notes
2008-10-17 10:21:10TO "COMM" BD#55
2008-10-16 09:01:34WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-10-02 Cont ID  
Sent By adarroug Date 2008-10-02 Time 15:00 Rev Time 0.00
Received By adarroug Date 2008-10-02 Time 14:59 Sent To  
Notes
2008-10-02 15:00:14TO "COMM" BD#32

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-09-25 Cont ID  
Sent By adarroug Date 2008-09-25 Time 11:16 Rev Time 0.00
Received By adarroug Date 2008-09-25 Time 11:16 Sent To B
Notes
2008-09-25 11:16:30TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-09-08 Cont ID  
Sent By adarroug Date 2008-09-08 Time 16:57 Rev Time 0.00
Received By adarroug Date 2008-09-08 Time 16:57 Sent To M
Notes
2008-09-08 16:58:05TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-02-05 Cont ID  
Sent By adarroug Date 2008-02-05 Time 13:27 Rev Time 0.00
Received By adarroug Date 2008-02-05 Time 13:27 Sent To  
Notes
2008-02-05 13:31:18TO "COMM" BD#43

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-28 Cont ID  
Sent By adarroug Date 2007-08-28 Time 16:15 Rev Time 0.00
Received By adarroug Date 2007-08-28 Time 16:15 Sent To  
Notes
2007-09-21 08:14:28TO "COMM" BD#46
2007-08-28 16:16:27WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-17 Cont ID  
Sent By mawillia Date 2007-07-17 Time 13:32 Rev Time 0.00
Received By mawillia Date 2007-06-01 Time 11:21 Sent To  
Notes
2007-06-18 08:43:49TO "COMM" BD#23
2007-06-01 11:22:11WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2008-10-28 Cont ID  
Sent By tgordon Date 2008-10-28 Time 16:41 Rev Time 0.30
Received By tgordon Date 2008-10-28 Time 16:41 Sent To  
Notes
2008-10-28 16:41:47REVISION TO MECH. PLAN M-1.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2008-10-23 Cont ID  
Sent By rregueir Date 2008-10-23 Time 08:53 Rev Time 0.00
Received By rregueir Date 2008-10-23 Time 08:53 Sent To B
Notes
2008-10-23 08:54:52REVISED M-1. MOVES CONDENSERS TO ROOF. PRODUCT APPROVAL
 FOR A/C STAND TO BE REVIEWED BY BUILDING.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2008-09-12 Cont ID  
Sent By rregueir Date 2008-09-12 Time 09:52 Rev Time 0.00
Received By rregueir Date 2008-09-12 Time 09:44 Sent To  
Notes
2008-09-12 09:52:26REVISION TO PAGE M.1 DATED 9/8/08
  
 ************************PROVISO***********************
  
 1. PVC DRAIN LINES SHALL NOT BE USED IN THE RETURN AIR
 PLENUM CLOSETS IN ACCORDANCE WITH FBC,M 602.2.1.
  
 2. PROVIDE THE PRODUCT APPROVAL FOR LOUVERS WITH
 ACCOMPANYING INSTALLATION INSTRUCTIONS ON JOBSITE AT
 TIME OF INSPECTION.
  
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2008-03-04 Cont ID  
Sent By rregueir Date 2008-03-04 Time 15:46 Rev Time 0.00
Received By rregueir Date 2008-03-04 Time 15:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-10-31 Cont ID  
Sent By rregueir Date 2007-10-31 Time 15:47 Rev Time 0.00
Received By rregueir Date 2007-10-31 Time 14:31 Sent To  
Notes
2007-10-31 15:47:05REVIEW #: 2ND. ACTION: PROVISO
  
 FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS FBC
 CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 ************************PROVISO***********************
  
 1. PVC DRAIN LINES SHALL NOT BE USED IN THE RETURN AIR
 PLENUM CLOSETS IN ACCORDANCE WITH FBC,M 602.2.1.
  
 2. PROVIDE THE PRODUCT APPROVAL FOR LOUVERS WITH
 ACCOMPANYING INSTALLATION INSTRUCTIONS ON JOBSITE AT
 TIME OF INSPECTION.
  
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-06-27 Cont ID  
Sent By rregueir Date 2007-06-27 Time 16:54 Rev Time 0.00
Received By rregueir Date 2007-06-27 Time 13:31 Sent To  
Notes
2007-06-27 16:54:04------------------DENIED--------------------
  
 FBC 2004 CODE FAMILYW/2006 REVISIONS
  
 1. ENERGY CALCULATIONS:
 A) THE BUILDING?S OWNER, THE OWNER?S ARCHITECT, OR
 OTHER AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER
 SHALL CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH
 THE CODE, AS PER SECTION 553.907, FLORIDA STATUTES,
 PRIOR TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION. FBC 13-103.1.2
 B) AN ACCURATELY COMPLETED FORM 400A-04R (GENERATED BY
 THE FLA/COM-2004 COMPUTER PROGRAM, VERSION 2.5)
 DEMONSTRATING THAT CODE COMPLIANCE HAS BEEN ACHIEVED
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FOR METHOD
 A COMPLIANCE. CALCULATIONS SHALL BE PERFORMED FOR THE
 CLIMATE ZONE IN WHICH THE BUILDING WILL BE LOCATED AND
 ACCORDING TO THE PROCEDURES SPECIFIED FOR METHOD A IN
 THIS SUBCHAPTER. 13-400.3.A METHOD A FORMS.
 C) CALCULATIONS CLAIM 2500 S.F. OF UNCONDITIONED SPACE
 BUT PLANS DO NOT SHOW ANY SEMIEXTERIOR BUILDING
 ENVELOPE THAT SEPARATES THE CONDITIONED FROM THE
 UNCONDITIONED SPACE. SEE FBC 13-2 DEFINITIONS: BUILDING
 ENVELOPE (B). PROVIDE SEPARATION BETWEEN SPACES OR
 REVISE ENERGY CALCULATIONS AND COOLING LOAD
 CALCULATIONS TO INCLUDE ALL INTERIOR SPACES.
 D) IF ALL SPACES ARE TO BE CONSIDERED CONDITIONED,
 PLEASE SEE FBC 13-403.1 DOOR TYPES REGARDING BACK DOOR
 AND GARAGE TYPE DOOR.
  
 2. PLAN NIDICATES FIRE DAMPERS TO BE LOCATED IN THE
 RATED CEILING. IF DUCT IS TO BE ABOVE A RATED CEILING,
 WHERE DO THE DUCTS FROM THE A/C CLOSETS PENETRATE THE
 RATED CEILING? ARE FIRE DAMPERS ALSO NEEDED IN THESE
 LOCATIONS? THE SPECIFIC LOCATION AND INSTALLATION
 DETAILS OF EACH FIRE DOOR, FIRE DAMPER, CEILING DAMPER
 AND SMOKE DAMPER SHALL BE SHOWN AND PROPERLY IDENTIFIED
 ON THE BUILDING PLANS BY THE DESIGNER. FBC,M 607.8
  
 3. BOTH AHUS ARE MARKED ON PLANS AS AHU #2. BOTH
 CONDENSERS ARE MARKED AS CU #1. PLEASE IDENTIFY
 EQUIPMENT ON PLANS CORRECTLY AND COORDINATE WITH
 ELECTRICAL PLANS. FBC 106.1.1
  
 4. SOUTH DUCT SYSTEM, PLEASE PROVIDE SIZES FOR ALL 9
 FLEX DUCTS.
  
 5. NORTH DUCT SYSTEM, PLAN STATES "8 24X24 LAY-IN..."
 BUT PLAN ONLY SHOWS 7 GRILLS, FLEX RUN-OUTS. WHICH IS
 CORRECT?
  
 6. NORTH SIDE AND SOUTH SIDE EXHAUST GRILLS AND OUTSIDE
 AIR LOUVERS ARE SHOWN OUTSIDE THE BUILDING IN MID-AIR.
 PLEASE CLARIFY. ALSO, THERE IS AN EXHAUST GRILL ON THE
 SOUTH SIDE OF THE BUILDING WHERE THERE IS NO EXHAUST
 FAN. PLEASE CLARIFY.
  
 7. EXTERIOR LOUVERS ARE SUBJECT TO THE FLORIDA PRODUCT
 APPROVAL SYSTEM PER FAC 9B-72. PLEASE PROVIDE PRODUCT
 APPROVAL SPECIFIC TO THE LOUVERS TO BE USED.
  
 8. ARE LOUVERS TO BE DUCTED TO UNITS OR OPEN TO THE
 CLOSET PLENUM? VENTILATION SYSTEMS SHALL BE DESIGNED TO
 BE CAPABLE OF REDUCING THE SUPPLY OF OUTDOOR AIR TO THE
 MINIMUM VENTILATION RATES REQUIRED BY SECTION 6.1.3 OF
 ASHRAE 62. SYSTEMS MAY BE DESIGNED TO SUPPLY OUTSIDE
 AIR QUANTITIES EXCEEDING MINIMUM LEVELS, BUT THEY SHALL
 BE CAPABLE OF OPERATING AT NO MORE THAN MINIMUM LEVELS
 THROUGH THE USE OF RETURN DUCTS, MANUALLY OR
 AUTOMATICALLY OPERATED CONTROL DAMPERS, FAN VOLUME
 CONTROLS, OR OTHER DEVICES. FBC 13-409.1.ABC.1.1
  
 9. A/C CLOSETS SHOW BLOCK WALL EXPOSED IN PLENUM AREAS.
 CAVITIES DESIGNED FOR AIR TRANSPORT SUCH AS MECHANICAL
 CLOSETS, CHASES, AIR SHAFTS, ETC. SHALL BE LINED WITH
 AN AIR BARRIER AND SEALED IN ACCORDANCE WITH SECTION
 410.1.ABC.3.7 AND SHALL BE INSULATED IN ACCORDANCE WITH
 SECTION 410.1.ABC.2 (MINIMUM R-8 FOR EXTERIOR WALLS).
 BUILDING CAVITIES WHICH WILL BE USED AS RETURN AIR
 PLENUMS SHALL BE LINED WITH A CONTINUOUS AIR BARRIER
 MADE OF DURABLE NONPOROUS MATERIALS. ALL PENETRATIONS
 TO THE AIR BARRIER SHALL BE SEALED WITH A SUITABLE
 LONG-LIFE MASTIC MATERIAL. FBC 13-410.1.ABC.3.6
  
 10. PLEASE SHOW MEANS AND LOCATION OF CONDENSATE
 DISPOSAL. PLANS INDICATE DISPOSAL IN PARKING LOT AREA.
 CONDENSATE FROM ALL COOLING COILS AND EVAPORATORS SHALL
 BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN APPROVED
 PLACE OF DISPOSAL. CONDENSATE SHALL NOT DISCHARGE INTO
 A STREET, ALLEY OR OTHER AREAS SO AS TO CAUSE A
 NUISANCE. FBC,M 307.2.1
  
 11. PLEASE SHOW MEANS OF SECONDARY OR AUXILIARY DRAIN
 PROTECTION IN ACCORDANCE WITH FBC,M 307.2.3.
  
 12. PLAN SHOWS CONDENSATE DRAIN LINE TO BE PVC.
 MATERIALS EXPOSED WITHIN PLENUMS SHALL BE
 NONCOMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX OF
 NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT
 MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84.
 FBC,M 606.2.2.1
  
 13. BALANCED RETURN IS REQUIRED FROM BREAK ROOM AREAS
 PER FBC,M 601.4.
  
 14. PLEASE PROVIDE OUTDOOR AIR CALCULATIONS SHOWING
 OCCUPANCY CLASSIFICATION, OCCUPANT LOADS AND REQUIRED
 CFM IN ACCORDANCE WITH FBC,M TABLE 403.3. FBC 106.1.2
  
 15. PLEASE PROVIDE ENGINEERED SYSTEM WITH DETAIL
 DRAWING SHOWING DESIGN WIND LOADS AND REQUIRED
 ATTACHMENTS PER FBC,M 301.13, FBC SEC 1609 AND FBC
 106.1.2.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-10-23 Cont ID  
Sent By lwagner Date 2008-10-23 Time 09:10 Rev Time 0.00
Received By lwagner Date 2008-10-23 Time 09:09 Sent To B
Notes
2008-10-23 09:10:51REVISED A-4. REMOVED SINK FROM BREAK ROOM.

Review Stop P PLUMBING
Rev No 3 Status P Date 2008-03-04 Cont ID  
Sent By kstevens Date 2008-03-04 Time 17:23 Rev Time 0.00
Received By kstevens Date 2008-03-04 Time 17:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-11-01 Cont ID  
Sent By kstevens Date 2007-11-01 Time 17:48 Rev Time 0.00
Received By kstevens Date 2007-11-01 Time 17:48 Sent To  
Notes
2007-11-01 17:54:39DENIED
 REFERENCE: FBC-2004 W/2006 AMENDMENTS
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
  
 ****FROM PREVIOUS REVIEW:
  
 1. OK
 2. OK
  
 3. SHT A-4 BREAK ROOM SINK SHALL BE ACCESSIBLE. PLEASE
 SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.24
 & ALL SUBSECTIONS. SHOW AN ELEVATION FOR SINK. SECTION
 106.1.2.
 ****RESPONSE NOTED, BUT SHOW COMPLIANCE FOR THE
 FOLLOWING:
 A. 11-4.24.4 SINK DEPTH
 B. 11-4.24.5 CLEAR FLOOR SPACE - FORWARD APPROACH
 REQUIRED. NO CABINET DOORS ALLOWED
 C. 11-4.24.6 EXPOSED PIPES & SURFACES
 D. 11-4.24.7 FAUCETS
  
 4. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING
 FOUNTAIN. SHOW COMPLIANCE WITH SECTION 11-4.15 WITH ALL
 SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A)
 PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR
 STOOPING.
 ****RESPONSE NOTED, NOT ADDRESSED
  
 5. OK
 6. OK
  
 7. SHT AM-7 SANITARY PLUMBING RISER & TYPICAL RISER DO
 NOT REFLECT THE FLOOR PLAN, NOR DO THEY MEET CODE
 REQUIREMENTS. NO BREAK ROOM SINK IS SHOWN ON RISERS,
 WATER CLOSETS AND LAVS ARE BACK TO BACK, DRINKING
 FOUNTAINS ARE NOT VENTED. (SEE RED LINE EXAMPLE IF
 PIPING IS GOING OUT THE SIDE OF THE BUILDING).
 ****RESPONSE NOTED, BUT THE DRINKING FOUNTAINS ARE NOT
 VENTED AS SHOWN. (SEE RED LINE CORRECTIONS).
  
 8. OK
  
 9. SUBMIT A WATER RISER DIAGRAM THAT REFLECTS THE FLOOR
 PLAN. SECTION 106.3.5.1.3(3)(8)(10)(13).
 ****RESPONSE NOTED, BUT THE DRINKING FOUNTAINS ARE NOT
 INDICATED ON THE RISER DIAGRAM.
  
 10. OK
 11. OK
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-07-13 Cont ID  
Sent By kstevens Date 2007-07-13 Time 18:54 Rev Time 0.00
Received By kstevens Date 2007-07-13 Time 18:48 Sent To  
Notes
2007-07-13 18:58:56DENIED
 REFERENCE: FBC-2004 W/2006 AMENDMENTS
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
  
 1. INDICATE CODES THAT THE PLANS WERE DESIGNED FROM.
 MINIMUM FBC-2004 W2006 AMENDMENTS (BLDG, MECH, PLMG
 ETC.).
  
 2. INDICATE OCCUPANCY TYPE ON PLANS. (BUSINESS,
 MERCANTILE ETC). SECTION 106.3.5.1.1(2)
  
 3. SHT A-4 BREAK ROOM SINK SHALL BE ACCESSIBLE. PLEASE
 SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.24
 & ALL SUBSECTIONS. SHOW AN ELEVATION FOR SINK. SECTION
 106.1.2.
  
 4. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING
 FOUNTAIN. SHOW COMPLIANCE WITH SECTION 11-4.15 WITH ALL
 SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A)
 PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR
 STOOPING.
  
 5. SHT A6 CLEAR FLOOR SPACE DETAILS. THE W/C SHALL BE
 18" OFF THE WALL TO THE CENTERLINE OF THE FIXTURE.
 DELETE "MIN." FROM THE DETAILS. SEE FIG 28.
  
 6. SHT A6 1ST COMMENT UNDER "NOTE". LAV CABINETS AND
 PARALLEL APPROACH ARE NOT APPROVED. DELETE REFERENCE
 FROM NOTES. SECTION 11-4.19.3.
  
 7. SHT AM-7 SANITARY PLUMBING RISER & TYPICAL RISER DO
 NOT REFLECT THE FLOOR PLAN, NOR DO THEY MEET CODE
 REQUIREMENTS. NO BREAK ROOM SINK IS SHOWN ON RISERS,
 WATER CLOSETS AND LAVS ARE BACK TO BACK, DRINKING
 FOUNTAINS ARE NOT VENTED. (SEE RED LINE EXAMPLE IF
 PIPING IS GOING OUT THE SIDE OF THE BUILDING).
  
 8. SHT AM-7 INDICATE ON THE FLOOR PLAN WHERE THE
 BUILDING DRAIN EXITS THE BUILDING AND HOW IT WILL BE
 PIPED FROM THERE. THE RISER DIAGRAM SHALL REFLECT THE
 PIPING SHOWN ON THE PLAN VIEW. SECTION 106.1.1.
  
 7. SUBMIT A WATER RISER DIAGRAM THAT REFLECTS THE FLOOR
 PLAN. SECTION 106.3.5.1.3(3)(8)(10)(13).
  
 8. A RPZV BACKFLOW IS REQUIRE ON THE WATER SERVICE.
 PLEASE INDICATE ON THE PLANS IF EXISTING. IF NOT SHOW
 ON THE WATER RISER DIAGRAM. SECTION 608.13.2
  
 9. WHEN THE OCCUPANCY OF THE BUILDING IS ESTABLISHED,
 MORE COMMENTS MAY BE FORTHCOMING AS MORE INFORMATION
 MAY BE REQUIRED. SECTION 106.1.2..
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 4 Status F Date 2008-10-07 Cont ID  
Sent By lfranco Date 2008-10-07 Time 16:15 Rev Time 0.00
Received By lfranco Date 2008-10-07 Time 16:15 Sent To  
Notes
2008-10-07 16:39:46PLANNING AND ZONING: **** FAILED - 2ND PROVISO NOT
 ADDRESSED***
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. THE PLANS WERE APPROVED WITH TWO (2) PROVISOS DATED
 2/20/08 BY CHRIS HOOPS. THE FIRST ONE REMAINS IN EFFECT
 (SHOWN HERE AS "A").
  
 A. THE PROPOSED ENLARGED COLUMNS AT FRONT OF BUILDING
 SHALL ONLY BE ENLARGED INWARD AND SHALL NOT BE
 PERMITTED TO ENCROACH ANY FURTHER TOWARDS THE PROPERTY
 LINES.
  
 THE SECOND PROVISO (SHOWN HERE AS "B"), HAS NOT BEEN
 ADDRESSED:
  
 B. THE PARKING LOT AT REAR SHALL BE STRIPED IN
 ACCORDANCE WITH THE CITY'S TYPICAL DETAIL (SEE
 ATTACHED). ADDITIONALLLY, THE REAR PARKING LOT MUST
 MAINTAIN A MINIMUM DRIVE AISLE OF 24 FEET BEHIND THE
 PARKING STALLS. THE DETAILS WERE PROVIDED AND ATTACHED
 TO THE 2/20/08 SET OF PLANS. PROVIDE THE SAME PARKING
 STALL DETAIL, INCLUDING BUT NOT LIMITED TO THE TWO (2)
 FOOT DIMENSION BETWEEN THE BACK OF WHEEL STOP AND
 CURBING OR LANDSCAPING.
  
 3. PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR): AS THE VALUE OF
 THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 THE FOLLOWING COMMENT WAS MADE ON THE 9/27/07
 SUBMITTAL, THE PERMIT DOES NOT SHOW LANDSCAPING, PLEASE
 CLARIFY:
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2008-02-20 Cont ID  
Sent By choops Date 2008-02-20 Time 09:47 Rev Time 0.00
Received By choops Date 2008-02-20 Time 09:47 Sent To  
Notes
2008-02-20 09:50:05***APPROVED - RESUB #2***
  
 PROVISOS:
  
 1)THE PROPOSED ENLARGED COLUMNS AT FRONT OF BUILDING
 SHALL ONLY BE ENLARGED INWARD AND SHALL NOT BE
 PERMITTED TO ENCROACH ANY FURTHER TOWARDS THE PROPERTY
 LINES.
  
 2)THE PARKING LOT AT REAR SHALL BE STRIPED IN
 ACCORDANCE WITH THE CITY'S TYPICAL DETAIL (SEE
 ATTACHED).ADDITIONALLY, THE REAR PARKING LOT MUST
 MAINTAIN A MINIMUM DRIVE AISLE OF 24 FEET BEHIND THE
 PARKING STALLS.
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2007-09-27 Cont ID  
Sent By choops Date 2007-09-27 Time 16:48 Rev Time 0.00
Received By choops Date 2007-09-27 Time 16:48 Sent To  
Notes
2007-09-27 16:50:41***FAILED***
  
  
 1)PLEASE PROVIDE TWO (2) COPIES OF A CURRENT SURVEY
 SHOWING THE SCOPE OF WORK WITH SETBACK DIMENSIONS TO
 ALL PROPERTY LINES.
  
 2)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C
 EQUIPMENT TO THE PROPERTY LINES.
  
 3)AS THE VALUE OF THE PROPOSED WORK EXCEEDS 50% OF
 THE VALUE OF THE STRUCTURE, A LANDSCAPE PLAN SHALL BE
 SUBMITTED SHOWING COMPLIANCE WITH ARTICLE XIV OF THE
 CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720