Plan Review Details - Permit 07051081
Plan Review Stops For Permit 07051081
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-07-01 Cont ID  
Sent By amorse Date 2007-07-01 Time 16:23 Rev Time 0.00
Received By amorse Date 2007-07-01 Time 16:23 Sent To PC
Notes
2007-07-01 16:41:48 
  
 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE,
 AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
 IMPACT FEES MAY NOT BE REQUIRED AND PLANS WILL BE
 STAMPED WITH $0 FEES
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*FEES IN THE AMOUNT OF 248.16 ARE DUE
 FOR INCREASED VALUE AND ARE PAYABLE PRIOR TO FURTHER
 REVIEW
  
 3)SUBMIT 2 COPIES OF SURVEY THAT SHOW ALL FRONT, SIDE
 AND REAR SETBACKS FROM RENOVATED WORK
  
 4)PROVIDE THE DESIGN PARAMETERS 2004 FBC W/ 2006
 AMENDMENTS AND A DESIGN PROFESSIONAL OR AN OWNER MUST
 ELECT ONE OR A COMBINATION OF LEVELS OF ALTERATION
 PURSUANT TO SECTIONS 303 , 304 AND 305 OF THE FBC
 EXISTING.
  
 5)PROVIDE WIND DESIGN DATA ON DRAWINGS PER 1603.1.4
 FBC AND THE DESIGN PRESSURES FOR THE NEW WINDOW AND
 DOOR
  
 6)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES,
 AND THE PRODUCT NOA THAT LISTS THE SYSTEM COMPONENTS/
 FASTENER LIST PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE GENERAL LIMITATIONS
 PAGE. ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 7)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 8)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE.
 THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG.
 WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE
 DENIED
  
 9)WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS PER
 313.1.1 FBC RES.
  
 10)PROVIDE IMPACT PROTECTION FOR OPENINGS PER 507.3
 FBC EXISTING
  
 11)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 12)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO A PERMIT BEING
 ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-13 Cont ID  
Sent By btrobaug Date 2007-06-13 Time 07:53 Rev Time 0.33
Received By btrobaug Date 2007-06-13 Time 07:44 Sent To M
Notes
2007-06-13 07:53:30 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW
  
 THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL
 COST OF LABOR AND MATERIAL. VALUATION REFERENCES MAY
 INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES PER 108.3 FBC AS
 AMENDED.ADJUST THE VALUE AT THE PERMIT CLERK?S DESK,
 AND PAY THE DIFFERENCE IN FEES PRIOR TO RESUBMITTING.
  
 A PERMIT SHALL NOT BE ISSUED UNTIL FEES AUTHORIZED
 UNDER SECTION 553.80, FLORIDA STATUTES, HAVE BEEN PAID.
 108.1 FBC.
  
 RECEPTACLE SPACING MUST COMPLY WITH 210.52(A) (1) AND
 210.52 (A) (2). 2005 NEC. SEE REVIEWED PLAN FOR
 APPROXIMATE LOCATIONS REQUIRED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-07 Cont ID  
Sent By adarroug Date 2007-06-07 Time 09:32 Rev Time 0.00
Received By adarroug Date 2007-06-07 Time 09:32 Sent To E
Notes
2007-06-07 09:32:54TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-07-01 Time   Rev Time 0.00
Received By adarroug Date 2007-05-31 Time 16:19 Sent To  
Notes
2007-05-31 16:19:32TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-06-14 Cont ID  
Sent By tgordon Date 2007-06-14 Time 09:50 Rev Time 0.20
Received By tgordon Date 2007-06-14 Time 09:50 Sent To B
Notes
2007-06-14 09:50:52NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-06-01 Cont ID  
Sent By choops Date 2007-06-01 Time 13:18 Rev Time 0.00
Received By choops Date 2007-06-01 Time 13:18 Sent To I
Notes
2007-06-01 13:20:11***FAILED***
  
  
 1)PLEASE PROVIDE 2 COPIES OF A CURRENT SURVEY
 SHOWING THE SCOPE OF WORK: WITH DIMENSIONS AND SETBACK
 DIMENSIONS TO THE PROPERTY LINES.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720