Plan Review Details - Permit 07050992
| Plan Review Stops For Permit 07050992 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-16 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-16 |
Time |
22:33 |
Sent To |
|
|
| Notes |
| 2007-07-16 16:43:17 | 3301 ELECTRONIC WAY | | | BUILDING PLAN REVIEW | | | PERMIT: 07050992 | | | ADD: 3301 ELECTRONIC WAY | | | CONT: SHAFFER ELECTRICAL | | | TEL: (954)868-9411 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)) GENERATOR SLAB & ANCHOR REQUIREMENTPLEASE | | | PROVIDE SIZE OF GENERATOR(WXL),PLUS PROVIDE PLANS | | | WITH THE INFORMATION DEPICTING HOLD DOWN BRACKETS, TYPE | | | OF FASTENER, AND THE MINIMUM EDGE DISTANCE THE DEVICE | | | REQUIRES WITHOUT LOADREDUCTION.SECOND, PROVIDE | | | INFORMATION ON THE SLAB, THICKNESS, WIDTH AND LENGTH, | | | IF WIREMESH, FIBER MESH OR IF STEEL REBAR WILL BEUSED. | | | THE NEW SLAB AND HOLD DOWN DETAILS: 104.2.1* ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | | | | 4) 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING INFORMATION | | | RELATED TO WIND SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 5) PROVIDE FLOOD ZONE ELEVATION CERTIFICATE FOR NEW | | | CONSTRUTION WITH BASE FLOOD ELEVATION, CITY CODE | | | REQUIRES AN ADDITIONAL 6". | | | | | | | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-23 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-23 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2007-06-23 16:29:29 | *** UNSAT *** | | | | | | | | | 1) NOTE: PLEASE SUBMIT PLANS WITH A COMPLETE LAYOUT OF | | | ALL EXISTING ELECTRICAL SERVICE EQUIPMENT AT THIS | | | BUILDING. PLEASE INDICATE ALL MAINS, DISCONNECTS ETC. | | | AT THIS TIME AS THE LOCATION OF THESE ITEMS ARE NOT | | | CLEAR, NO REVIEW OF LOCATIONS CAN BE DONE. | | | FBC 106.1.2, 106.3.5.1.2 | | | NEC 230.70,230.71,230.72, 225.31-225.39, 702.11 PLEASE | | | SEE MISSING DISCONNECTING MEANS AS REQUIRED. THIS IS | | | BASED ON NO INFORMATION PROVIDED. | | | | | | 2) NOTE: PLEASE SUBMIT A COMPLETE SURVEY WITH ALL | | | SETBACKS ON PLANS FOR EQUIPMENT ETC. | | | PLEASE SEE POSSIBLE COMMENTS FROM OTHER TRADES FOR | | | THIS. | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE KNOW IF THIS IS INDEED IN A FLOOD ZONE, | | | THE ELEVATION OF UNIT WILL NEED TO BE ON PLANS. PLEASE | | | KNOW THAT AN ELEVATION CERTIFICATE WILL BE REQUIRED | | | BEFORE FINAL. | | | | | | 4) NOTE: PLEASE SEE LOAD CALCULATIONS MENTIONS 2-WORK | | | STATIONS AND CONTRACT MENTIONS THREE. THE LOAD ON THE | | | GENERATOR IS NOT OF A CONCERN HOWEVER PLEASE CORRELATE | | | FOR RECORD SETS OF PLANS. | | | FBC 106.1.2 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-16 |
Time |
23:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-16 |
Time |
22:35 |
Sent To |
|
|
| Notes |
| 2007-08-16 22:41:24 | *****DENIED***** | | | | | | | | | 1.STATIONARY GENERATORS FOR EMERGENCY USE OR STANDBY | | | POWER SHALL BE INSTALLED WITH COMPLIANCE WITH NFPA | | | 110. | | | | | | 2.EQUIPMENT USING GAS AND RELATED GAS PIPING SHALL BE | | | IN ACCORDANCE WITH NFPA 54. | | | | | | 3.SPECIFY WHAT EQUIPMENT WILL BE POWERED BY THE | | | GENERATOR. | | | | | | 4.PROVIDE PROPER SETBACKS TO PROPERTY LINES AND AT | | | LEAST 10' DISTANCE TO BUILDING OPENINGS. | | | | | | 5.PROVIDE MANUFACTURE SPEC SHEETS FOR THE EQUIPMENT. | | | | | | 6.DETAIL HOW THE EQUIPMENT WILL BE PROTECTED FROM | | | VEHICULAR AND / OR MECHANICAL DAMAGE. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-09 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-07 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2007-07-09 10:24:56 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | | | | 1. WHEN SUBMITTING THE UP TO DATE SITE PLAN, INDICATE | | | THE DISTANCE OFF THE STRUCTURE TO THE GENERATOR. | | | | | | 2. SUBMIT MANUF. INSTALLATION INSTRUCTIONS WITH THE | | | APPLICATION SHOWING THE MINIMUM REQUIRED CLEARANCES | | | REQUIRED FOR MAINTENANCE AND SERVICE OF THE GENERATOR. | | | SECTION 106.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-17 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-29 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2007-06-14 14:01:34 | TO "COMM" BD#21 | | 2007-05-29 10:20:01 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-06-28 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-06-28 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2007-06-28 11:01:18 | ------------------DENIED--------------------- | | | | | | FBC 2004 CODE FAMILY W/2006 REVISIONS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH NFPA | | | 110-02 | | | | | | 1. PLEASE INDICATE IN SITE PLAN THE LOCATION OF NEAREST | | | OPENINGS IN THE BUILDING, AND THE DISTANCE TO THE | | | GENERATOR, INCLUDING: DOORS, WINDOWS, SIFFIT VENTS, AIR | | | INTAKES. | | | | | | 2. PLEASE PROVIDE ACTUA ELEVATIONS SHOWING THE | | | ELEVATION OF THE GENERATOR TO BE ABOVE THE BASE FLOOD | | | ELEVATION. ALSO, SLAB SHALL RAISE THE GENERATOR MINIMUM | | | 6" ABOVE GRADE LEVEL PER NFPA 110-7.4.1.1. | | | | | | 3. PLEASE INDICATE ON PLAN THE DISTANCE OF THE | | | GENERATOR FROM THE BUILDING AND PROVIDE WALL | | | CONSTRUCTION TYPE TO VERIFY PROPER CLEARANCE FROM | | | COMBUSTIBLES. ALSO, PLEASE PROVIDE MINIMUM REQUIRED | | | CLEARANCE FOR SERVICE, MAINTENANCE AND INSPECTION PER | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS, WHICH WERE | | | NOT INCLUDED WITH THIS APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
jbabcock |
Date |
2007-06-26 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
jbabcock |
Date |
2007-06-28 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2007-06-26 08:21:46 | PLANNING AND ZONING ***FAILED*** | | | | | | 1. PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | | | | 2. PROVIDE A SIGNED AND SEALED SURVEY THAT WAS CREATED | | | WITHIN A YEAR. | | | | | | 3. PROVIDE SETBACKS FROM THE GENERATOR TO THE NORTH AND | | | WEST PROPERTY LINES.PURSUANT TO SECTION 94-305(4) | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | | FEET INTO A SETBACK. WINDOW AIR-CONDITIONING UNITS MAY | | | NOT PROJECT MORE THAN 18 INCHES INTO A REQUIRED SIDE | | | SETBACK. | | | | | | 4. PURSUANT TO SECTION 94-444 (B) ALL GENERATORS AND | | | TANKS SHALL BE SCREENED. SCREENING SHALL BE CONSTRUCTED | | | OF BRICK, DECORATIVE CONCRETE, OTHER DECORATIVE | | | MASONRY, OR COMPARABLY DURABLE WOOD AND STEEL. WALLS | | | SHALL BE LANDSCAPED WITH SHRUBS AND HEDGES PLANTED AT | | | TWO-FOOT INTERVALS. PROVIDE DETAILS/CROSS SECTIONS | | | ACCORDINGLY ON PLANS. | | | | | | FOR ANY ADDITIONAL INFORMATION OR QUESTIONS YOU MAY | | | CONTACT: | | | | | | JULIA BABCOCK | | | PLANNER | | | (561) 822-1442 | | | [email protected] |
|
|
|