Plan Review Details - Permit 07050970
Plan Review Stops For Permit 07050970
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-07-30 Cont ID  
Sent By shill Date 2007-07-30 Time 17:33 Rev Time 0.00
Received By shill Date 2007-07-30 Time 17:33 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-27 Cont ID  
Sent By shill Date 2007-06-27 Time 08:04 Rev Time 0.00
Received By shill Date 2007-06-27 Time 08:04 Sent To  
Notes
2007-06-27 08:11:55****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 FROM PREVIOUS LIST:
  
 _XX_2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 2ND REVIEW - ORIGINALS REQUIRED.ONE WAS A PHOTOCOPY.
  
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 2ND REVIEW - A SIMILAR FORM WAS SUBMITTED BUT DOES NOT
 INLUDE SHUTTER MOUNTING TYPE.CODE COMPLIANCE CANNOT
 BE DETERMINED.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.THE FL
 STATE PRODUCT APPROVAL IS EXPIRED, 2001 CODE RATHER
 THAN 2004.PLEASE PRINT A CURRENT APPROVAL.IF ONE IS
 NOT AVAILABLE, PLEASE ADVISE.
  
 2ND REVIEW - NOT ADDRESSED.IN ORDER FOR A LOCAL
 PRODUCT APPROVAL TO BE ISSUED, PLEASE SUBMIT THE LETTER
 FROM THE ENGINEER WHICH WAS PROVIDED TO MIAMIDADE
 STATING THAT THE CALCULATIONS ARE IN ACCORDANCE WITH
 FBC2004.NO 33% INCREASE FOR STEEL ALLOWED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-18 Cont ID  
Sent By shill Date 2007-06-18 Time 15:09 Rev Time 0.00
Received By shill Date 2007-06-18 Time 15:09 Sent To  
Notes
2007-06-18 15:16:12****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 _XX_2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 _XX_3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.THE FL
 STATE PRODUCT APPROVAL IS EXPIRED, 2001 CODE RATHER
 THAN 2004.PLEASE PRINT A CURRENT APPROVAL.IF ONE IS
 NOT AVAILABLE, PLEASE ADVISE.
  
 _XX_6.THE APPLICATION REFERS TO TWO DIFFERENT
 LICENSE NUMBERS.REVISE TO INCLUDE ONLY ONE.PROVIDE
 A COPY OF THE COUNTY SPECIALTY LICENSE AS THE COUNTY
 WEBSITE IS NOT WORKING AND I CANNOT CONFIRM LICENSE
 TYPE.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 _XX_8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 _XX_9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-17 Cont ID  
Sent By adarroug Date 2007-07-17 Time 13:51 Rev Time 0.00
Received By adarroug Date 2007-07-17 Time 13:51 Sent To B
Notes
2007-07-17 13:51:48TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-24 Cont ID  
Sent By adarroug Date 2007-06-24 Time 17:04 Rev Time 0.00
Received By adarroug Date 2007-06-24 Time 17:04 Sent To B
Notes
2007-06-24 17:04:51TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-18 Cont ID  
Sent By shill Date 2007-06-18 Time 15:16 Rev Time 0.00
Received By shill Date 2007-05-25 Time 14:56 Sent To  
Notes
2007-05-25 14:57:00TO "MISC" BOX#1