| Plan Review Stops For Permit 07050937 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2009-02-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2009-02-06 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2009-02-06 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2009-02-06 10:41:56 | PERNIT #07050937 SUBMITTAL OF STATE OF FLORIDA DEPT OF | | | HEALTH APPROVAL INSPECTION FOR POOL. SENT TO JERALD | | | INBOX. 2/6/09 MJ. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-05-02 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-05-02 |
Time |
17:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-10-11 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-10-11 |
Time |
11:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-25 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-25 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2007-06-25 14:30:35 | BUILDING PLAN REVIEW | | | PERMIT: 07050937 | | | ADD: 2485 METROCENTRE BLVD. | | | CONT: MPC POOLS INC. | | | TEL: (561)784-5334 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PROJECT WAS DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | | | | 3)THE FENCE REQUIRES A SEPERATE PERMIT WITH MORE | | | DETAIL ABOUT THE TYPE OF FENCE TO BE INSTALLED. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-28 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-28 |
Time |
08:23 |
Sent To |
P |
|
| Notes |
| 2008-04-28 08:23:45 | REVISION FOR DELETING SPA. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-12-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-20 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-19 |
Time |
17:01 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-11 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-11 |
Time |
12:52 |
Sent To |
|
|
| Notes |
| 2007-10-11 14:00:20 | ** DENIED 2ND REVIEW** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW STILL | | | NEED TO BE ADDRESSED ALONG WITH NEW NOTE DUE TO | | | ADDITIONAL INFORMATION ONLY NOW SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE PANEL SCHEDULE PROVIDED FRO THE | | | VAK-PAK PANEL IS MISSING THE CIRCUITS FOR THE TWO SETS | | | OF GFI RECEPTACLES WHICH FEED CHEMICAL FEEDERS ETC. | | | 408.4, 220, 310.16 ETC | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 2) NOTE: PLEASE SEE PREVIOUS COMMENT REQUESTED FOR | | | INFORMATION ON HOW NEW PANEL WAS GOING TO BE FED FOR | | | FEEDERS, OVER CURRENT PROTECTION ETC. THE RESPONSE | | | LETTER MENTIONS TO SEE BASE BUILDING E-13 SHEETS. | | | THE E-13 SHEETS WERE SUBMITTED HOWEVER THIS SHEET | | | INDICATES A DIFFERENT PANEL FOR POOL EQUIPMENT (2EQ) | | | AND CLEARLY SHOWS BRANCH CIRCUITS FOR POOL EQUIPMENT | | | AND NOT A SUB-FEED FOR A VAK-PAK PANEL. | | | PLEASE CORRELATE ALL PLANS, EQUIPMENT, FEEDERS, BRANCH | | | CIRCUITS, OVER CURRENT PROTECTION ETC. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-20 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-20 |
Time |
18:11 |
Sent To |
|
|
| Notes |
| 2007-06-20 18:47:49 | ** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE PLANS SHALL HAVE CODES STATED WHICH | | | ARE RELEVANT TO PROJECT AND DESIGN. THE FOLLOWING CODES | | | ARE TO BE STATED ON BOTH ELECTRICAL AND ARCHITECTURAL | | | SHEETS AS ADOPTED BY THE STATE OF FLORIDA AS OF | | | DECEMBER 8TH, 2006. | | | 2004 FBC W/2006 REVISIONS. | | | 2005 NFPA-70 | | | ** OTHER CODES MAY BE REQUESTED FROM OTHER TRADES. | | | | | | 2) NOTE: PLEASE SEE PLANS SUBMITTED DO NOT SHOW THE | | | REQUIRED *EQUAL-POTENTIAL PLANE* FOR GROUND AS REQUIRED | | | PER 680-26 UNDER THE 2005 NEC. | | | | | | 3) NOTE: PLEASE PROVIDE ELECTRICAL WIRING DETAIL FOR | | | NEW EQUIPMENT. PLEASE INDICATE HOW NEW VAK-PAK IS BEING | | | FED. PANEL, CONDUCTORS, CONDUITS, LOADS ON EXISTING IF | | | FED FROM OTHER EQUIPMENT ETC. | | | AS NOT INFORMATION WAS SUBMITTED NOT REVIEW FOR CODE | | | COMPLIANCE CAN BE DONE AT THIS TIME. | | | NEC 220, 215.3, 230.42, 240.4, 310.16, 408.4 ETC | | | FBC106.1.2, 106.3.5.1.2 | | | | | | 4) NOTE: PLEASE PROVIDE INFORMATION FOR EMERGENCY | | | SHUT-OFF 680.41 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-10 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-10 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-02-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-05 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-05 |
Time |
09:15 |
Sent To |
B |
|
| Notes |
| 2009-02-05 09:16:08 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-21 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-21 |
Time |
16:25 |
Sent To |
Z |
|
| Notes |
| 2008-04-21 16:25:19 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-14 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-14 |
Time |
16:50 |
Sent To |
E |
|
| Notes |
| 2007-12-14 16:50:58 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2007-10-09 15:28:56 | TO "COMM" BD#63 | | 2007-09-17 10:12:47 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-10 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-25 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2007-06-14 13:37:05 | TO "COMM" BD#18 | | 2007-05-25 08:28:04 | WAITING FOR "COMM' BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-06-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-06-21 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-06-21 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-05-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-02 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-02 |
Time |
14:03 |
Sent To |
B |
|
| Notes |
| 2008-05-02 14:05:39 | REVISION SHEETS 1THRU 4:"OK" DELETE SPA AND SPA | | | EQUIPMENT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-11-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-13 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-11-13 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2007-11-13 12:33:16 | PROVISO - OVER SHALL BE DISCHARGED TO STORM |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-06 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-06 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2007-07-06 12:48:28 | DENIED | | | REFERENCE: FBC-2004 CHAPTER 424 | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | CITY WPB MUNICIPAL CODE | | | | | | 1. INDICATE ON THE PLANS THE CODES RELEVENT TO THIS | | | PROJECT. FBC-2004 PLUMBING, FBC-2004 BUILDING ETC. | | | SECTION 106.1.1. | | | | | | 2. SHT 5 OF 5 PLEASE INDICATE THAT ALL WASTE SHALL | | | DRAIN INTO THE SANITARY SYSTEM, AND ALL OVERFLOW SHALL | | | DRAIN INTO THE STORM SYSTEM. MUNICIPAL CODE SECTIONS | | | 90-125(5) AND 90-203(A). | | | | | | 3. SUBMIT THE MANUF SPECIFICATIONS FOR THE POOL | | | HEATERS. SECTION 303.4. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-04-24 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2008-04-24 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2008-04-24 |
Time |
16:11 |
Sent To |
E |
|
| Notes |
| 2008-04-24 17:06:32 | REVISION - REMOVING SPA EQUIPMENT AND SPA |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-10-11 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-10-11 |
Time |
18:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2007-07-03 |
Time |
19:03 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2007-07-02 |
Time |
18:18 |
Sent To |
I |
|
| Notes |
| 2007-07-03 19:03:42 | PLANNING AND ZONING:**** FAILED **** | | | | | | | | | 1.PROVIDE RESPONSES TO COMMENTS IN WRITING. | | | | | | 2.THE HOLIDAY INN EXPRESS @ METROCENTRE PROJECT IS | | | PART OF THE METROCENTRE CORPORATE PARK COMMERCIAL | | | PLANNED DEVELOPMENT (METROCENTRE CORPORATE PARK CPD) | | | PD878, THEREFORE, PROVIDE A COPY OF THE STAMPED | | | APPROVED SITE PLAN BY PLANNING AND ZONING WITH THE | | | RE-SUBMITTAL PACKET. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME BELOW. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] |
|
|