Plan Review Details - Permit 07050833
Plan Review Stops For Permit 07050833
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-13 Cont ID  
Sent By shill Date 2007-08-13 Time 17:34 Rev Time 0.00
Received By shill Date 2007-08-13 Time 17:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-07-24 Cont ID  
Sent By shill Date 2007-07-24 Time 15:38 Rev Time 0.00
Received By shill Date 2007-07-24 Time 15:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-06-26 Cont ID  
Sent By shill Date 2007-06-26 Time 10:21 Rev Time 0.00
Received By shill Date 2007-06-26 Time 10:21 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-08-07 Cont ID  
Sent By btrobaug Date 2007-08-07 Time 14:11 Rev Time 0.00
Received By btrobaug Date 2007-08-07 Time 13:52 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-07-19 Cont ID  
Sent By btrobaug Date 2007-07-19 Time 09:41 Rev Time 0.00
Received By btrobaug Date 2007-07-19 Time 09:35 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-05-30 Cont ID  
Sent By btrobaug Date 2007-05-30 Time 10:38 Rev Time 0.33
Received By btrobaug Date 2007-05-30 Time 10:38 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-06-11 Cont ID  
Sent By mperson Date 2007-06-11 Time 16:33 Rev Time 0.00
Received By mperson Date 2007-06-11 Time 16:33 Sent To B
Notes
2007-06-11 16:34:13NOTE: NO POOL HEATER.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-30 Cont ID  
Sent By adarroug Date 2007-07-30 Time 16:00 Rev Time 0.00
Received By adarroug Date 2007-07-30 Time 16:00 Sent To E
Notes
2007-07-30 16:02:52TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-09 Cont ID  
Sent By adarroug Date 2007-07-09 Time 08:32 Rev Time 0.00
Received By adarroug Date 2007-07-09 Time 08:32 Sent To Z
Notes
2007-07-09 08:32:35TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-29 Cont ID  
Sent By adarroug Date 2007-05-29 Time 09:10 Rev Time 0.00
Received By adarroug Date 2007-05-29 Time 09:10 Sent To E
Notes
2007-05-29 09:10:30TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2007-05-22 Time 14:47 Sent To  
Notes
2007-05-22 14:48:01TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-08-10 Cont ID  
Sent By mperson Date 2007-08-10 Time 15:17 Rev Time 0.33
Received By mperson Date 2007-08-10 Time 15:17 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-07-23 Cont ID  
Sent By mperson Date 2007-07-23 Time 09:44 Rev Time 0.33
Received By mperson Date 2007-07-23 Time 09:44 Sent To B
Notes
2007-07-23 10:12:17DENIED 2ND TIME
 REFERENCE:
 ** FBC-2004 SECTION 424.2 OR R4101 SWIMMING POOLS
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 COMMENTS WERE NOT ADDRESSED FROM 1ST PLUMBING PLAN
 REVIEW:
  
 1. NOTE: PLEASE CORRELATE THE EQUIPMENT LAYOUT WITH
 THE LEGEND. PLEASE REFERENCE THE RED LINE CORRECTIONS
 TO THE EQUIPMENT LAYOUT THAT ARE CORRELATED WITH THE
 LEGEND. PER FBC-2004 CHAPTER 1 SECTION 106.1.1
 INFORMATION ON CONSTRUCTION DOCUMENTS. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELAVENT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 2. SEE ATTACHED NOTICE FS 553.80(2)(B) REGARDING FOUR
 (4) TIMES THE FEE.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-06-11 Cont ID  
Sent By mperson Date 2007-06-11 Time 16:22 Rev Time 0.33
Received By mperson Date 2007-06-11 Time 16:22 Sent To G
Notes
2007-06-11 16:33:14DENIED
 REFERENCE:
 ** FBC-2004 SECTIONS424.2 OR R4101 SWIMMING POOLS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION IS REQUIRED FOR
 GAS/PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PER FBC-2004 CHAPTER 1, SECTION 106.1.1
 INFORMATION ON CONSTRUCTION
 DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL
 BE OF SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE
 AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS,
 AS DETERMINED BY THE
 BUILDING OFFICIAL.
 NOTE: PLEASE CORRELATE THE EQUIPMENT LAYOUT WITH THE
 LEGEND. THE EQUIPMENT IDENTIFIED WITH THE LETTERS ON
 THE EQUIPMENT LAYOUT DOES NOTMATCH THE EQUIPMENT
 IDENTIFIED BY LETTERS IN THE LEGEND. PLEASE CORRECT ON
 THE RESUBMITTAL.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 3 Status P Date 2007-08-10 Cont ID  
Sent By choops Date 2007-08-10 Time 16:33 Rev Time 0.00
Received By choops Date 2007-08-10 Time 16:33 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-07-10 Cont ID  
Sent By choops Date 2007-07-10 Time 09:13 Rev Time 0.00
Received By choops Date 2007-07-10 Time 09:13 Sent To E
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-05-24 Cont ID  
Sent By choops Date 2007-05-24 Time 10:12 Rev Time 0.00
Received By choops Date 2007-05-24 Time 10:12 Sent To I
Notes
2007-05-24 10:16:37***FAILED***
  
  
 1)PLEASE INDICATE POOL EQUIPMENT DIMENSION, AND
 SETBACK DIMENSION TO PROPERTY LINES ON SURVEYS. (MAY
 NOT ENCROACH MORE THAN 4 FT. INTO A REQUIRED SETBACK)
  
 2)AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE
 SURROUNDING THE POOL, A FENCE PERMIT SHALL BE SUBMITTED
 CONCURRENTLY AND SHALL CONFORM TO THE MINIMUM STANDARDS
 PROVIDED BELOW.
  
 AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION 94-304(D)(2)(B)+(C):
  
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720