Plan Review Details - Permit 07050808
Plan Review Stops For Permit 07050808
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2007-08-27 Cont ID  
Sent By jwitmer Date 2007-08-27 Time 08:41 Rev Time 1.55
Received By jwitmer Date 2007-06-19 Time 16:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2007-12-06 Cont ID  
Sent By jwitmer Date 2007-12-06 Time 08:52 Rev Time 0.77
Received By jwitmer Date 2007-12-06 Time 08:51 Sent To  
Notes
2007-12-06 08:52:41REVISION# 5 STRUCTURAL REVISIONS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-10-05 Cont ID  
Sent By jjohnsto Date 2007-10-05 Time 14:23 Rev Time 2.00
Received By jjohnsto Date 2007-10-05 Time 14:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-09-20 Cont ID  
Sent By jwitmer Date 2007-09-20 Time 08:15 Rev Time 1.55
Received By jwitmer Date 2007-09-20 Time 07:24 Sent To  
Notes
2007-09-20 08:16:22CITYPLACE STAR BUCKS
 650 S ROSEMARY AVE
 SEPT 20,2007
  
 BUILDING PLAN REVIEW
  
 PERMIT: 07050808
 ADD: 650 S ROSEMARY AVE
 CONT: PEMBERTON BUILDING
 TEL: (561)744-3399
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 3RDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) COMPLIED..
  
 3) NOTE:FL S S 713.13NOTICE OF COMMENCEMENT, TO BE
 FILED WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF
 THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE
 RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6) THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 4) THIRD REQUEST, THE PRODUCT APPROVALS SUBMITTED
 REQUIRE FLORIDA COVERSHEETS. PRODUCT APPROVALS
 SUBMITTED WITH PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA PRODUCT
 APPROVAL SYSTEM. FOR INFORMATION PLEASE SEE THE STATE
 WEBSITE AT WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A
 COVER SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM
 THE STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE
 APPROVAL, SUBMIT AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE 9B-72. REPORTS
 MISSING THE FLORIDA APPROVAL COVERSHEETS ARE:
 4A) PGT SERIES **PW-701** IS A NON-IMPACT WINDOW,
 PROVIDE DOCUMENTATION THAT THE EXISTING SHUTTERS ARE
 RATED FOR THE 140 MPH WIND ZONE & LARGE MISSILE
 TESTED.
 4B) PGT SERIES HR-810 IS A HORIZONTAL ROLLER NOT USED
 SEE SHEET G2.0
 4C) FIXED WINDOW- SHEET G2.0 INDICATES NEW LARGE
 MISSILE RATED NO REPORTS SUBMITTED.
 4D) FIREDOOR SERIES 4080 SINGLE
 4E FIREDOOR SERIES S-6070
  
 5) COMPLIED.
  
 6-8) COMPLIED.
  
 9A)TRANSFORMER MOUNT THERE IS A DISCREPANCY BETWEEN
 THE STRUCTURAL SHEET S2 AND THE ELECTRICAL SHEET E2.
 THE UPDATED S2 DOES NOW SHOW STEEL TUBING TO HANDLE THE
 LOADS OF THE BRAKET CARRYING THE TRANSFORMERS WEIGHT
 BUT THE E2 SHEET NEEDS TO CORRELATE THE THE SAME TYPE
 OF STRUCTURAL SUPPORT FORTHIS UNIT. DISCREPANCY BETWEEN
 PLANS, 106.1.2*
  
 9B) THE SECOND ISSUE IS THE DRYWALL RUNS BEHIND
 BRACKET, THERE WOULD APPEAR TO BE CRUSHING CONCERNS
 THIS PORTION OF WALL WILL QUICKLY BE CRUSHED AND THE
 BRACKET BECOMING LOOSE! 106.1.2*?
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC
 REQUIREMENT SHALL BE APPLICABLE.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
  
  
  
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-27 Cont ID  
Sent By jwitmer Date 2007-08-27 Time 08:42 Rev Time 1.55
Received By jwitmer Date 2007-08-27 Time 07:24 Sent To  
Notes
2007-08-27 08:44:33BUILDING PLAN REVIEW
  
 PERMIT: 07050808
 ADD: 650 S ROSEMARY AVE
 CONT: PEMBERTON BUILDING
 TEL: (561)744-3399
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) COMPLIED..
  
 3) NOTE:FL S S 713.13NOTICE OF COMMENCEMENT, TO BE
 FILED WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF
 THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE
 RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6) THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 4) 2ND REQUEST, THE PRODUCT APPROVALS SUBMITTED REQUIRE
 FLORIDA COVERSHEETS. PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED
 TO COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE
 APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL,
 SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR
 SITE SPECIFIC FORM PER RULE 9B-72. REPORTS MISSING THE
 FLORIDA APPROVAL COVERSHEETS ARE:
 4A) PGT SERIES **PW-701**
 4B) PGT SERIES HR-810
 4C) FIREDOOR SERIES 4080 SINGLE
 4D) FIREDOOR SERIES S-6070
  
 5) COMPLIED.
  
 6) SHEET G1.0 SITE INFO:
 6A) 2ND REQUEST, PLEASE SEE THAT PLANS SUBMITTED AFTER
 DEC. 8/ 2006 WILL BE REVIEWED TO THE 2006 FBC, AND THE
 2006 FBC EXISTING BUILDING CODE. PLEASE INDICATE TO
 WHAT LEVEL YOU WILL BE DOING ALTERATIONS UNDER THE
 SCOPE OF THIS PERMIT?
  
 6B) ENERGY CODE WILL BE REVIEWED UNDER THE 2006 FBC,
 CHAPTER 13- 400 COMMERCIAL
  
 6C) COMPLIED.
  
 6D)SHEET G1.0 2ND REQUEST, TYPE OF OCCUPANCY SEE: 302.1
 GENERAL.STRUCTURES OR PORTIONS OF STRUCTURES SHALL BE
 CLASSIFIED WITH RESPECT TO OCCUPANCY IN ONE OR MORE OF
 THE GROUPS LISTED BELOW.
  
 6E) TYPE OF CONSTRUCTION: 503.1 GENERAL.THE HEIGHT
 AND AREA FOR BUILDINGS OF DIFFERENT CONSTRUCTION TYPES
 SHALL BE GOVERNED BY THE INTENDED USE OF THE BUILDING
 AND SHALL NOT EXCEED THE LIMITS IN TABLE 503 EXCEPT AS
 MODIFIED HEREAFTER PROVIDE THE MINIMUM BUILDING TYPE
 FOR THIS STRUCTURE.
  
 7) COMPLIED.
  
 8) COMPLIED.
  
 9) NEW COMMENT: SHEETE.2 TRANSFORMER MOUNT DETAIL
 INDICATES THAT TRANSFORMER BRACKET IS TO USE (2) ??
 WITH 6? EMBEDMENT INTO FILLED WALL CELLS (CMU). SHEET
 A2.0 INDICATES THIS WALL TO BE A TYPE# 23 5/8? 20G
 METAL STUD WITH5/8? GREEN BOARD . PLEASE CORRECT
 DETAIL.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
  
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-15 Cont ID  
Sent By jwitmer Date 2007-06-15 Time 07:00 Rev Time 1.33
Received By jwitmer Date 2007-06-15 Time 07:00 Sent To  
Notes
2007-06-15 07:37:46BUILDING PLAN REVIEW
 PERMIT: 07050808
 ADD: 650 S ROSEMARY AVE
 CONT: PEMBERTON BUILDING
 TEL: (561)744-3399
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) THE WRONG PROPERTY CONTROL NUMBER WAS USED ON THIS
 PERMIT APPLICATION, THIS MAY AFFECT THE ADDRESS. PLEASE
 CORRECT THE PROPERTY CONTROL NUMBER.
  
 3)FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 4)THE PRODUCT APPROVALS SUBMITTED REQUIRE FLORIDA
 COVERSHEETS. PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO
 COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE SEE THE
 STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A
 COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF THE
 PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN
 APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC
 FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5) PRODUCT APPROVAL FIREDOOR DIVISION OF ARK II
 MANUFACTURING IS MISSING THE TECHNICAL SHEETS 1-4.
 PLEASE PROVIDE.
  
 6) SHEET G1.0 SITE INFO:
 6A) PLEASE SEE THAT PLANS SUBMITTED AFTER DEC. 8/ 2006
 WILL BE REVIEWED TO THE 2006 FBC, AND THE 2006 FBC
 EXISTING BUILDING CODE.
 PLEASE INDICATE TO WHAT LEVEL YOU WILL BE DOING
 ALTERATIONS UNDER THE SCOPE OFTHIS PERMIT?
  
 6B) ENERGY CODE WILL BE REVIEWED UNDER THE 2006 FBC,
 CHAPTER 13- 400 COMMERCIAL
  
 6C) ACCESSIBILITY WILL BE REVIEWED UNDER THE 2006 FBC,
 BUILDING CHAPTER 11
  
 6D) TYPE OF OCCUPANCY SEE:302.1 GENERAL.STRUCTURES
 OR PORTIONS OF STRUCTURES SHALL BE CLASSIFIED WITH
 RESPECT TO OCCUPANCY IN ONE OR MORE OF THE GROUPS
 LISTED BELOW. STRUCTURES WITH MULTIPLE USES SHALL BE
 CLASSIFIED ACCORDING TO SECTION 302.3
  
 6E) TYPE OF CONSTRUCTION: 503.1 GENERAL.THE HEIGHT
 AND AREA FOR BUILDINGS OF DIFFERENT CONSTRUCTION TYPES
 SHALL BE GOVERNED BY THE INTENDED USE OF THE BUILDING
 AND SHALL NOT EXCEED THE LIMITS IN TABLE 503 EXCEPT AS
 MODIFIED HEREAFTER PROVIDE THE MINIMUM BUILDING TYPE
 FOR THIS STRUCTURE.
  
 7) SHEET S1 DOESN'T INDICATE TO WHAT WIND DESIGN THE
 EXTERIOR COMPONENTS WERE DESINDE TOO? 2004 FL. BLD
 CODE 1603.1.4 THE
 FOLLOWING INFORMATION RELATED TO WIND
 SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 8) A1.0 THE EXTERIOR OF THE BUILDING INDICATES THATNO
 WORK IS TO BE COMPLETED ON THE EXISTING WINDOWS
 ALTHOUGH THERE ARE PRODUCT APPROVAL FOR FIXED AND
 HORIZONTAL SLIDERS?
 PLEASE CORRECT THIS SHEET , SHEET A2.0 INDICATES
 WINDOWS TO BE REPLACED.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-09-15 Cont ID  
Sent By dpalmer Date 2007-09-15 Time 12:55 Rev Time 0.00
Received By dpalmer Date 2007-09-15 Time 12:39 Sent To  
Notes
2007-09-15 12:59:132007-09-15 12:59:13
  
 *** PLANS REDLINED ***
  
 THE E-SHEETS STILL INDICATE A CONCRETE WALL FOR SUPPORT
 AND STRUCTURAL MOUNTING FOR THE TRANSFORMER. THIS WAS
 SPECIFICALLY NOTED ON PREVIOUS REVIEW TO CORRELATE WITH
 THE ARCHITECTURAL AND STRUCTURAL SHEETS. THIS WAS NOT
 DONE.
 AS THE STRUCTURAL ENGINEER HAS PROVIDED A DETAIL WHICH
 IS DESIGNED FOR THE SUPPORT, THE E-SHEET (2) WAS
 REDLINED TO SEE THE DETAIL ON S-2.
 ** ANY CHANGES ARE TO BE REVISED AND SUBMITTED.
 ** ANY REVISIONS ARE TO BE DONE BEFORE ROUGH ELECTRICAL
 INSPECTION.
 ** AT NO TIME MAY A CEILING BE INSTALLED BELOW THE
 TRANSFORMER ENCLOSING THIS ABOVE.THIS IS NOTED ON
 PLANS FOR NO CEILING.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2007-08-26 Cont ID  
Sent By dpalmer Date 2007-08-26 Time 18:12 Rev Time 0.00
Received By dpalmer Date 2007-08-26 Time 17:28 Sent To  
Notes
2007-08-26 18:13:032007-08-26 18:13:03
  
 ** DENIED 2ND REVIEW **
  
 ** PLEASE SEE SOME COMMENTS FROM THE PREVIOUS REVIEW
 ARE IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS
 BASED ON THE PLANS AND DOCUMENTS SUBMITTED AND
 REVISIONS MADE TO PLANS WHICH WERE NOT ON PREVIOUS
 SUBMITTED PLANS.
  
 ** PLEASE BE SURE ALL NEW REVISED SHEETS CONTAINS THE
 REQUIRED CITY PLACE REVIEW STAMP.OLD/VOIDED SHEETS
 WIHT THE STAMP WILL NOT BE ACCEPTED IN LIEU OF THE
 REVISED SHEETS CONTAINING NEW STAMPS.
  
  
 1) NOTE:PLEASE SEE AS REQUESTED ON THE PREVIOUS
 REVIEW:
 PLEASE SUBMIT TWO COMPLETE SETS WITH ALL SHEETS IN
 ORDER AS STATED ON COVER SHEET.
 PLEASE SEE THE END OF THE PREVIOUS REVIEW AND NOTE #1
 FROM PREVIOUS REQUESTED ALL OLD/VOIDED SHEETS TO BE
 REMOVED FROM SETS AND ONLY INCLUDE NEW REVISED SHEETS
 IN SETS.
 THE REVIEW ALSO REQUESTED NOT TO ATTACH PRODUCT
 APPROVALS/ ENERGY CALCULATIONS AND SUPPORTING DOCUMENTS
 DOWN THE LEFT SIDE OF PLANS. THESE SHOULD BE ATTACHED
 INTO TWO SETS BOUND TOGETHER IN SOME FASHION.THESE
 MAY BE PLACED IN SPIRAL BOOK OR OTHER FOLDER OF SOME
 TYPE LABELED/TABBED FOR EASE OF REVIEW IN EXPEDITING
 THE PLAN REVIEW PROCESS.
 ** PLEASE SEE NOTE BELOW LABELED AS IMPORTANT.
  
 ** THE DOCUMENTS WHICH WERE ATTACHED DOWN THE LEFT SIDE
 OF PLANS WERE REMOVED.
  
 2) NOTE: PLEASE SUBMIT ENERGY CALCULATIONS WHICH ARE
 SIGNED DATED AND SEALED AS REQUIRED PER FAC
 61G15-23.002, FS 471.025 AND FBC 13-103.1.1.1. PLEASE
 CLARIFY HOW THE TOTAL LPD ON THE CALCULATIONS IS
 DIFFERENT THAN THAT STATED ON THE PLANS.
 13-415.2, 13-415.1.C
  
 3) NOTE: PLEASE SEE THE RISER HAS BEEN REVISED FOR THE
 TRANSFORMER HOWEVER NO GROUNDING ELECTRODE SYSTEM IS
 SHOWN?
 PLEASE SEE 250.50, 250.20, 250.30, 250.66 ETC.
  
 4) NOTE: PLEASE SEE THE STRUCTURAL DETAIL SUBMITTED IS
 OK, HOWEVER SHOULD BE REVIEWED BY THE
 ARCHITECT/STRUCTURAL ENGINEER AND SIGNED AS REVIEWED
 FOR ADEQUATE SUPPORT.
 THE REVISIONS TO THE ARCHITECTURAL PLANS SHOULD INCLUDE
 ANY REVISIONS FOR FILLED CELLS AS STATED ON DETAIL.
 PLEASE SEE THE ARCHITECTURAL SHEETS INDICATE THIS WALL
 AS METAL STUDS, NO POUR CONCRETE AS STATED ON
 E-SHEETS.
 PLEASE PROVIDE A STRUCTURAL SUPPORTING DETAIL FOR THE
 75KVA WALL MOUNTED TRANSFORMER.
 PLEASE PROVIDE ELEVATION DETAIL TO MEET 110.26A3 PLEASE
 ALSO SEE 450.13 AND PROVIDE A NOTE THAT EQUIPMENT MAY
 NOT BE INSTALLED ABOVE CEILING LINE. FBC 106.1.2.
  
 5) NOTE: PLEASE SEE 210.8B2 FOR REQUIRED GFI PROTECTION
 FOR 15/20A 120V CIRCUITS IN KITCHEN AREA(S).
 THIS NOTE REMAINS AS THE PLANS ARE SIMPLY ONLY STATING
 THE CODE IN LIEU OF SHOWING AND INDICATING THE ACTUAL
 PROTECTION EITHER BY WAY AT THE DEVICE LOCATION OR
 BREAKERS IN PANELS.
 PLEASE SEE FBC 106.1.1, 106.1.2, 106.3.5.1.2 WHICH
 REQUIRES DETAIL(S) TO BE SHOWN.
 PLEASE ADJUST.
  
 6) NOTE: AS REQUESTED ON PREVIOUS REVIEW:
 PLEASE SEE THE APPLIED ADDRESS DOES NOT MATCH WITH
 PLANS.
 PLEASE SEE ANY COMMENTS FROM OTHER TRADES. PLANS WILL
 BE FORWARDED TO THE ADDRESSING REVIEW FOR COMMENTS.
 PLEASE BE SURE ALL TITLE BLOCKS CONTAIN THE CORRECTED
 ADDRESS ALONG WITH PERMIT APPLICATION.
 FAC 61G1-16.004
 ** THIS IS THE SAME COMMENT AS THE APPLIED ADDRESS AND
 LOCATION IS 650 S ROSEMARY WHEREAS THE PLANS STATE 600
 S ROSEMARY.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS.
  
 AS STATED IN THE PREVIOUS REVIEWS:
 PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By dpalmer Date 2007-06-19 Time 12:43 Rev Time 0.00
Received By dpalmer Date 2007-06-19 Time 11:44 Sent To  
Notes
2007-06-19 12:44:01*** UNSAT ***
  
 1) NOTE: PLEASE SUBMIT TWO COMPLETE SETS WITH ALL
 SHEETS IN ORDER AS STATED ON COVER SHEET. PLEASE SEE
 ELECTRICAL AND PLUMBING PLANS ARE MIXED.
 PLEASE ALSO DO NOT ATTACH PRODUCT APPROVALS/ ENERGY
 CALCULATIONS AND SUPPORTING DOCUMENTS DOWN THE LEFT
 SIDE OF PLANS. THESE SHOULD BE ATTACHED INTO TWO SETS
 BOUND TOGETHER IN SOME FASHION.THESE MAY BE PLACED IN
 SPIRAL BOOK OR OTHER FOLDER OF SOME TYPE LABELED/TABBED
 FOR EASE OF REVIEW IN EXPEDITING THE PLAN REVIEW
 PROCESS.
 ** PLEASE SEE NOTE BELOW LABELED AS IMPORTANT.
  
 2) NOTE: PLEASE BE SURE PLANS THE CURRENT CODES AS
 FOLLOWS.
 2004 FBC W/2006 REVISIONS.
 2005 NFPA-70
 2003 NFPA-101
 ** PLEASE SEE POSSIBLE COMMENTS FROM OTHER TRADES WHICH
 MAY REQUIRE OTHER CODES.
 THESE SECTIONS SHOULD ALSO BE STATED ON ELECTRICAL
 PLANS AS WELL AS PROJECT COVER SHEET.
  
 3) NOTE: PLEASE SUBMIT ENERGY CALCULATIONS AS ADOPTED
 BY FBC 2004 W/2006 REVISIONS.13-415.1.C, 13-415.2
 PLEASE SEE THE SHEET ATTACHED DOES NOT SHOWIF THIS IS
 THE LATEST ADOPTED VERSION NOR DOES IT CONTAIN THE
 INPUT DATA REPORT IN ORDER TO REVIEW FOR COORDINATION
 WITH PLANS AND LIGHTING FIXTURE SCHEDULE. PLEASE SEE
 THE USE AS STATED.
 ** AS THIS WAS NOT SUBMITTED FOR REVIEW PLEASE BE SURE
 THE FIXTURES, TYPE OF FIXTURES AND WATTAGE ON FIXTURES
 ETC CORRELATE WITH PLANS AND FIXTURE SCHEDULE.
  
 4) NOTE: PLEASE KNOW LOW VOLTAGE SCOPE OF WORK SHOWN
 FOR ANY PHONE OR CATV WILL BE REQUIRED UNDER A SEPARATE
 PERMIT. THESE PLANS MAY BE REFERENCED FOR PERMIT;
 HOWEVER FEES AND PERMIT APPLICATION WILL BE REQUIRED.
 PLEASE KNOW ANY LOW VOLTAGE SECURITY WORK WILL ALSO BE
 UNDER A SEPARATE PERMIT.
  
 5) NOTE: PLEASE SEE THE FEEDERS BEING SHOWN TO THE
 TRANSFORMER INDICATE A NEUTRAL CONDUCTOR? PLEASE
 CLARIFY HOW THIS IS POSSIBLE WHEN THIS IS A SEPARATELY
 DERIVED SYSTEM.
 250.6,250.24,250.20,250.30 ETC.
  
 6) NOTE: PLEASE PROVIDE A STRUCTURAL SUPPORTING DETAIL
 FOR THE 75KVA WALL MOUNTED TRANSFORMER.
 PLEASE ALSO SEE 450.13 AND PROVIDE A NOTE THAT
 EQUIPMENT MAY NOT BE INSTALLED ABOVE CEILING LINE. FBC
 106.1.2.
  
 7) NOTE: PLEASE SEE 210.8B2 FOR REQUIRED GFI PROTECTION
 FOR 15/20A 120V CIRCUITS IN KITCHEN AREA(S).
  
 8) NOTE: PLEASE SEE THE APPLIED ADDRESS DOES NOT MATCH
 WITH PLANS. PLEASE SEE ANY COMMENTS FROM OTHER TRADES.
 PLANS WILL BE FORWARDED TO THE ADDRESSING REVIEW FOR
 COMMENTS.
 PLEASE BE SURE ALL TITLE BLOCKS CONTAIN THE CORRECTED
 ADDRESS ALONG WITH PERMIT APPLICATION.
 FAC 61G1-16.004
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES
 WHICH MAY AFFECT ELECTRICAL PLANS.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2007-10-01 Cont ID  
Sent By mawillia Date 2007-10-01 Time 12:37 Rev Time 0.00
Received By mawillia Date 2007-10-01 Time 12:35 Sent To  
Notes
2007-10-01 12:36:25*****APPROVED*****
  
 PLAN SHEET A1.0 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2007-09-25 Cont ID  
Sent By mawillia Date 2007-09-25 Time 13:40 Rev Time 0.00
Received By mawillia Date 2007-09-25 Time 13:03 Sent To  
Notes
2007-09-25 13:11:09*****PROVISO*****
  
 PLAN SHEETS G2.0 AND E3.0 WERE STAMPED, INITIALED, AND
 DATED;PLAN SHEET A1.0 TO BE FIRE-STAMPED WHEN THE
 FOLLOWING COMMENT TAKEN FROM THE PREVIOUS FIRE PLAN
 REVIEW HAS BEEN ADDRESSED:
 5.ON THE APPROPIATE EXTERIOR ELEVATION, POST THE
 NUMERICAL ADDRESS VISIBLE FROM SOUTH ROSEMARY AVENUE.
 AS PER WEST PALM BEACH CODE, THOSE NUMBERS SHALL BE NO
 LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN WIDTH.
 SHOW/DISPLAY ACTUAL ADDRESS NUMBER AND LOCATION
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805/6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2007-08-29 Cont ID  
Sent By mawillia Date 2007-08-29 Time 13:25 Rev Time 0.00
Received By mawillia Date 2007-08-29 Time 13:06 Sent To  
Notes
2007-08-29 13:25:33*****DENIED*****
  
 THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE
 PLAN REVIEW STILL NEED TO BE ADDRESSED:
  
  
 2.PLEASE EXPLAIN THE NUMERICAL ADDRESS DIFFERENCE.
 THE PERMIT APPLICATION HAS 650 SOUTH ROSEMARY WHEREAS
 THE SUBMITTED PLANS HAVE 600 SOUTH ROSEMARY AVENUE.
 PLEASE BE ADVISED THAT THE CORRECT ADDRESS FOR THIS
 PROJECT SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED
 PLAN SHEET.
  
 3.ON SHEET G2.0, SITE LOCATION MAP, REFERENCE IS MADE
 TO ROSEMARY PLAZA.WHAT/WHERE IS ROSEMARY PLAZA?
  
 4.DEMOLITION OR CONSTRUCTION OPERATIONS SHALL NOT
 INTERFERE OR HINDER EMERGENCY ACCESS RESPONSE TO THE
 PROPERTY OR VICINITY THEREOF (INCLUDING STREETS, FIRE
 LANES).
  
 5.ON THE APPROPIATE EXTERIOR ELEVATION, POST THE
 NUMERICAL ADDRESS VISIBLE FROM SOUTH ROSEMARY AVENUE.
 AS PER WEST PALM BEACH CODE, THOSE NUMBERS SHALL BE NO
 LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN WIDTH.
  
 6.SPECIFY THE INTERIOR WALL AND CEILING FINISH
 MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C.
  
 7.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805/6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-07-10 Cont ID  
Sent By mawillia Date 2007-07-10 Time 12:18 Rev Time 0.00
Received By mawillia Date 2007-07-10 Time 11:04 Sent To  
Notes
2007-07-10 12:15:52*****DENIED*****
  
  
 1.THE APPLICABLE CODES SHALL BE REFERENCED:FIRE
 CODE - FLORIDA FIRE PREVENTION CODE (2004 EDITION);
 LIFE SAFETY - NFPA 101 (2003 EDITION).
  
 2.PLEASE EXPLAIN THE NUMERICAL ADDRESS DIFFERENCE.
 THE PERMIT APPLICATION HAS 650 SOUTH ROSEMARY WHEREAS
 THE SUBMITTED PLANS HAVE 600 SOUTH ROSEMARY AVENUE.
 PLEASE BE ADVISED THAT THE CORRECT ADDRESS FOR THIS
 PROJECT SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED
 PLAN SHEET.
  
 3.ON SHEET G2.0, SITE LOCATION MAP, REFERENCE IS MADE
 TO ROSEMARY PLAZA.WHAT/WHERE IS ROSEMARY PLAZA?
  
 4.DEMOLITION OR CONSTRUTION OPERATIONS SHALL NOT
 INTERFERE OR HINDER EMERGENCY ACCESS RESPONSE TO THE
 PROPERTY OR VICINITY THEREOF (INCLUDING STREETS, FIRE
 LANES).
  
 5.ON THE APPROPIATE EXTERIOR ELEVATION, POST THE
 NUMERICAL ADDRESS VISIBLE FROM SOUTH ROSEMARY AVENUE.
 AS PER WEST PALM BEACH CODE, THOSE NUMBERS SHALL BE NO
 LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN WIDTH.
  
 6.SPECIFY THE INTERIOR WALL AND CEILING FINISH
 MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C.
  
 7.SHOW THE LOCATION OF THE 2A:10BC RATED FIRE
 EXTINGUISHER(S) WHICH SATISFY THE 75' TRAVEL DISTANCE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS
 ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805/6722

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-11-15 Cont ID  
Sent By adarroug Date 2007-11-15 Time 11:19 Rev Time 0.00
Received By adarroug Date 2007-11-15 Time 11:19 Sent To  
Notes
2007-12-05 11:24:0512/5/07FIRE REVIEW NOT REQUIRED.SENT TO JIM
 WITMER'S DESK FOR BUILDING REVIEW. LM
2007-11-28 11:41:31TO "COMM" BD#17
2007-11-15 11:19:30WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-10-01 Cont ID  
Sent By adarroug Date 2007-10-01 Time 12:38 Rev Time 0.00
Received By adarroug Date 2007-10-01 Time 12:38 Sent To B
Notes
2007-10-01 12:39:05TO "JWITMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-09-14 Cont ID  
Sent By adarroug Date 2007-09-14 Time 11:12 Rev Time 0.00
Received By adarroug Date 2007-09-14 Time 11:12 Sent To  
Notes
2007-09-14 11:36:00TO "COMM" BD#57--EXPEDITED PERMIT--

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-07 Cont ID  
Sent By dpalmer Date 2007-08-07 Time 20:55 Rev Time 0.00
Received By dpalmer Date 2007-08-07 Time 20:55 Sent To  
Notes
2007-08-26 17:29:14TO COMM BOARD SPACE #35
2007-08-07 20:55:36WAITING FOR COMM BOARD.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-07-10 Cont ID  
Sent By mawillia Date 2007-07-10 Time 12:16 Rev Time 0.00
Received By mawillia Date 2007-05-22 Time 11:29 Sent To  
Notes
2007-06-12 12:18:30TO "COMM" BD#9
2007-05-22 11:29:41WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-09-17 Cont ID  
Sent By rregueir Date 2007-09-17 Time 19:57 Rev Time 0.00
Received By rregueir Date 2007-09-17 Time 19:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-09-07 Cont ID  
Sent By rregueir Date 2007-09-07 Time 17:23 Rev Time 0.00
Received By rregueir Date 2007-09-07 Time 17:22 Sent To  
Notes
2007-09-07 17:23:43THE CONDITIONS OF THE PROVISO HAVE BEEN SATISFIED. PLAN
 NOTES CALL FOR INTERNAL FLOAT SWITCH ON PRIMARY DRAIN
 PAN.
  
 RONALD J REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-06-21 Cont ID  
Sent By rregueir Date 2007-06-21 Time 10:11 Rev Time 0.00
Received By rregueir Date 2007-06-20 Time 16:21 Sent To  
Notes
2007-06-21 10:11:06***************PROVISO****************
 PLEASE PROVIDE A SOCONDARY OR AUXILIARY DRAIN
 PROTECTION SYSTEM PER FBC,M 307.2.3:
  
 A SECONDARY DRAIN OR AUXILIARY DRAIN PAN SHALL BE
 REQUIRED FOR EACH COOLING OR EVAPORATOR COIL WHERE
 DAMAGE TO ANY BUILDING COMPONENTS WILL OCCUR AS A
 RESULT OF OVERFLOW FROM THE EQUIPMENT DRAIN PAN OR
 STOPPAGE IN THE CONDENSATE DRAIN PIPING.
  
 RONALD J REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-09-20 Cont ID  
Sent By kstevens Date 2007-09-20 Time 09:58 Rev Time 0.00
Received By kstevens Date 2007-09-20 Time 09:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2007-08-28 Cont ID  
Sent By kstevens Date 2007-08-28 Time 07:10 Rev Time 0.00
Received By kstevens Date 2007-08-28 Time 07:10 Sent To  
Notes
2007-08-28 07:17:01DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 ****FROM PREVIOUS REVIEW. COMMENT NUMBERS TO REMAIN THE
 SAME:
  
 1. OK
  
 2. SHT P2.0INDICATES REVERSE OSMOSIS FILTER. FILTER
 SHALL MEET THE REQUIREMENTS OF NSF-58. PLEASE SUBMIT
 MANUF. SPECIFICATIONS SHOWING COMPLIANCE. SECTION
 611.2.
 ****RESPONSE FROM ENGINEER, "TO BE ADDRESSED BY
 ARCHITECT". NO COMMENT RESPONSE FROM ARCHITECT, COMMENT
 NOT ADDRESSED.
  
 3. OK
 4. OK
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-06-20 Cont ID  
Sent By kstevens Date 2007-06-20 Time 15:51 Rev Time 0.00
Received By kstevens Date 2007-06-20 Time 15:51 Sent To  
Notes
2007-06-20 16:06:50DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. SHT A0.0 NOTES #8 IN THE REMOVAL OF ANY PART OF A
 DRAINAGE SYSTEM, DEAD ENDS ARE PROHIBITED. SECTION
 704.5. ALL DEMO'D/CAPPED PIPES SHALL BE LEFT UNCOVERED
 UNITL INSPECTED AND APPROVED BY FIELD INSPECTOR.
  
 2. SHT P2.0INDICATES REVERSE OSMOSIS FILTER. FILTER
 SHALL MEET THE REQUIREMENTS OF NSF-58. PLEASE SUBMIT
 MANUF. SPECIFICATIONS SHOWING COMPLIANCE. SECTION
 611.2.
  
 3. SHT P3.0 NOTES #'S 1 & 2 INDICATE INDIRECT WASTE TO
 A FLOOR DRAIN. FLOOR DRAINS ARE NOT APPROVED INDIRECT
 WASTE RECEPTORS. INDIRECT WASTE SHALL DRAIN TO A FLOOR
 SINK OR A HUB DRAIN PER SECTIONS 802.3 & 802.3.2.
 PLEASE CHANGE REFERENCES.
  
 4. SHT P3.0 NOTE # 24 INDICATES AN AAV. THESE ARE NOT
 SHOWN ON THE RISER DIAGRAM OR FLOOR PLAN, AND ARE NOT
 NEEDED IN A COMBINATION WASTE & VENT SYSTEM PER SECTION
 912.2.2.PLEASE DELETE REFERENCE FROM FLOOR PLAN &
 NOTES.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2007-09-20 Cont ID  
Sent By eschneid Date 2007-09-20 Time 18:04 Rev Time 0.00
Received By eschneid Date 2007-09-20 Time 18:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-08-28 Cont ID  
Sent By eschneid Date 2007-08-28 Time 17:13 Rev Time 0.00
Received By eschneid Date 2007-08-28 Time 17:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By eschneid Date 2007-06-19 Time 10:56 Rev Time 0.00
Received By eschneid Date 2007-06-19 Time 10:56 Sent To  
Notes
2007-06-19 11:08:51FAILED
  
 1) PLEASE RESPOND TO ALL COMMENTS IN WRITING.
  
 2) THE PARCEL CONTROL NUMBER FOR THE JOB SITE IS
 INCORRECT.
  
 3) IF THE KIOSK IS ACTUALLY ON PCN 74434321130160020,
 THEN THE PARCEL HAS BEEN ILLEGALLY SUBDIVIDED.
  
 4) THE SIGNAGE SHALL BE UNDER A SEPARATE PERMIT.
  
 5) ARE THE TABLES TO BE PERMANENTLY AFFIXED TO THE
 GROUND?IF SO, THEY WILL REQUIRE A SEPARATE PERMIT AND
 IT SHALL BE NOTED AS SUCH ON THIS PERMIT.THE
 INSTALLATION OF PERMANENT TABLES REQUIRES THE APPROVAL
 OF A MINOR PLANNED DEVELOPMENT AMENDMENT BY THE
 PLANNING AND ZONING DEPARTMENT.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1435.