| Plan Review Stops For Permit 07050744 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-25 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-24 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-27 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-27 |
Time |
12:34 |
Sent To |
PC |
|
| Notes |
| 2007-06-27 16:30:44 | BUILDING PLAN REVIEW | | | PERMIT: 07050744 | | | ADD: 529 S.FLAGLER DR #2308 | | | CONT: A.D. SABA ENTERPRISE INC. | | | TEL: (561)969-2920 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)AS STATED IN THE PREVIOUS REVIEW BUILDING PLANS | | | SHALL BE DRAWIN TO A MINIMUM 1/8 INCH SCALE. PER | | | SEC.106.1.3*THE PLANS SHALL ALSO BE OF DRAFTSMAN | | | QUALITY TO INDICATE THE NATURE AND EXTENT OF THE WORK | | | PROPOSED. THE BUILDING OFFICIAL MAY SET STANDARDS | | | THROUGH DEPARTMENTAL POLICY STANDARDS FOR PLANS AND | | | SPECIFICATIONS. "NO WHITE OUT" "NO HAND WRITING" ON THE | | | DRAWINGS. | | | | | | 3)AN EXISTING FLOOR AND ELEVATION PLAN OF THE AREA | | | SHALL BE SUBMITTED ALONG WITH THE PROPOSED FLOOR PLAN | | | SHOW ALL CHANGES WITH THE ACCURATE DIMENTIONS. THE | | | DRAWING SUBMITTED NEEDS MORE AND SPECIFIC INFORMATION | | | AND DETAILS. AS NOTED IN THE FIRST REVIEW, CONSTRUCTION | | | DOCUMENTS SHALL BE DIMENSIONED AND DRAWN UPON SUITABLE | | | MATERIAL, CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED. | | | | | | 4)THE PLANS SUBMITTED ARE NOT DRAWN TO SCALE. THE | | | DETAIL SUBMITTED IS NOT DRAWN TO SCALE AND IS NOT | | | COMPLETE. THE BUILDING OFFICIAL MAY REQUIRE DETAILS AND | | | OTHER DATA NECESSARY TO DESCRIBE THE CONSTRUCTION | | | PROJECT. WPB AMENDMENTS 106.1.2* | | | | | | NOTE: THE RESPONSE TO THE REVIEWERS SHALL NOT BE PLACE | | | ON THE DRAWINGS, SO PLEASE REMOVE THEM FROM THE | | | SUBMITTED PLANS. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-09 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-09 |
Time |
13:17 |
Sent To |
PC |
|
| Notes |
| 2007-06-09 14:09:31 | BUILDING PLAN REVIEW | | | PERMIT:07050744 | | | ADD: 529S. FLAGLER DR/ | | | CONT: A.D. SABA ENTERPRISE INC. | | | TEL: (561)969-2920 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST. | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2)106.1.3* BUILDING PLANS SHALL BE DRAWN TO A MINIMUM | | | 1/8 INCH SCALE. | | | 106.1 THE DRAWINGS SHALL BE SINGED AND DATED BY THE | | | RESPONSIBLE PERSON. IF PREPARED BY A DESIGN | | | PROFESSINOAL REGISTERED UNDER THE LAWS OF THIS STATE, | | | THE DRAWINGS SHALL BE SEAL /SIGN AND DATED ACCORDING TO | | | CH.481 AND 471 OF THE FLORIDA STATUTES. | | | | | | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* | | | | | | 4)106.1.1CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED. INDICATE THE HEIGHT OF THE NEW COUNTER TOP | | | AND THE TOTAL SQUARE SQUARE FOOTAGE OF THE NEW COUNTER | | | AND BACKSPLASH. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-18 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-18 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-21 |
Time |
07:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-21 |
Time |
07:14 |
Sent To |
|
|
| Notes |
| 2007-06-21 07:42:20 | *** UNSAT2ND REVIEW *** | | | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW NEED | | | TO BE ADDRESSED ALONG WITH NEW COMMENTS BASED ON | | | INFORMATION AND/OR CHANGES NOW ON PLANS. | | | | | | 1) NOTE:PLEASE SEE NOT ALL CODES AS LISTED ARE SHOWN | | | ON PLANS. PLEASE SEE THE YEAR OF THE CODE DOES NEED TO | | | BE STATED. ONLY THE FBC WAS ADDED WITH THE CORRECT YEAR | | | AND AMENDMENTS. | | | ** PREVIOUS NOTE** | | | PLEASE SEE THE SUBMITTED DOCUMENTS REQUIRE THE CODES TO | | | BE STATED ON PLANS. | | | PLEASE SEE THE FOLLOWING ARE REQUIRED FOR ELECTRICAL | | | AND OTHERS WILL BE REQUIRED FOR OTHER TRADES. PLEASE | | | KNOW AS OF DECEMBER 8TH, 2006 THE STATE ADOPTED THE | | | 2006 REVISIONS TO THE 2004 FBC AND THE 2005 NFPA-70. | | | PLEASE LIST THE FOLLOWING | | | 2004 FBC W/ 2006 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | | | | 2) NOTE:PLEASE DO NOT REFERENCE LICENSURE UNDER FS | | | 481.229 AS THIS SECTION OF THE FS IS FOR ARCHITECTS AND | | | EXEMPTIONS. THE STATUTE IN WHICH THE CONTRACTOR MAY | | | SIGN FOR THIS SCOPE OF WORK DOES NOT NEED TO BE ON | | | PLANS. | | | | | | 3) NOTE: PLEASE SEE THE PREVIOUS NOTE MENTIONED THAT | | | EITHER SMOKE ALARMS OR SMOKE DETECTORS WOULD NEED TO BE | | | BROUGHT UP TO CODE AND WOULD NEED TO BE SHOWN DEPENDING | | | ON THE SYSTEM BEING INSTALLED. PLEASE SEE THE PLANS AND | | | NOTES INDICATE THESE AS SD FOR SMOKE DETECTORS, YET THE | | | NOTES MENTIONS THESE AS 120V WITH BATTERY BACK UP? | | | PLEASE KNOW SMOKE ALARMS ARE DEVICE WHICH NOT ONLY | | | DETECT BUT ALSO SOUND AN ALARM. IF INSTALLING SMOKE | | | ALARMS AS SHOWN, THESE DEVICES ONLY DETECT AND SIGNAL | | | FOR ALARM. NO SOUNDING, HORN DEVICES WERE LOCATED ON | | | PLANS. PLEASE BE SURE THE SYSTEM IN WHICH IS BEING | | | PROPOSED IS COMPLETE. IF THESE ARE 120V W/ BATTERY BACK | | | UP WHICH DETECT AND SOUND, PLEASE CHANGE TO SA AND | | | SMOKE ALARM DESIGNATION? PLEASE ALSO SEE 210.12 FOR | | | REQUIRED ARC FAULT AS CIRCUITING AS NEEDED IS NOT ON | | | PLANS OR THE BRIEF PANEL SCHEDULE SUBMITTED. NFPA-72 | | | 11.5.1.1, 11.8.3. | | | | | | 4) NOTE: PLEASE SEE THE PANEL SCHEDULE AS SUBMITTED IS | | | ONLY INDICATING NEW CIRCUITS HOWEVER THESE IS MISSING | | | CONDUCTOR SIZE FOR OVEN AND NO BREAKER SIZE OR WIRE | | | SIZE IS BEING SHOWN FOR THE NEW COOK-TOP? | | | PLEASE SUBMIT THE COMPLETED PANEL SCHEDULE FOR NEW AND | | | EXISTING CIRCUITS IN THESE AREAS BEING RENOVATED. | | | 408.4, 240.4, 310.16 | | | | | | 5) NOTE:PLEASE SEE THAT NO HAND WRITTEN ITEMS ARE | | | PERMITTED ON PLANS IN PEN OR PENCIL. PLEASE SEE LIGHTS | | | OVER KITCHEN COUNTER WHICH WERE ADDED IN PEN. | | | FBC ADMIN SECT 106.1, 106.3.5.1.2 | | | | | | 6) NOTE: PLEASE SEE 210.70A1AS THE SWITCHES FOR BATH | | | ROOM LIGHTING SHOULD BE IN THE BATHROOM. | | | (1) HABITABLE ROOMS AT LEAST ONE WALL SWITCH-CONTROLLED | | | LIGHTING OUTLET SHALL BE INSTALLED IN EVERY HABITABLE | | | ROOM AND BATHROOM. | | | | | | ** PLEASE KNOW THE RESPONSES TO COMMENTS NEED NOT BE ON | | | PLANS ONLY THE NEEDED DETAIL FOR CONSTRUCTION OR CODE | | | COMPLIANCE. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-03 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-03 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2007-06-03 15:23:40 | ** UNSAT** | | | | | | 1) NOTE: PLEASE SEE THE SUBMITTED DOCUMENTS REQUIRE THE | | | CODES TO BE STATED ON PLANS. | | | PLEASE SEE THE FOLLOWING ARE REQUIRED FOR ELECTRICAL | | | AND OTHERS WILL BE REQUIRED FOR OTHER TRADES. PLEASE | | | KNOW AS OF DECEMBER 8TH, 2006 THE STATE ADOPTED THE | | | 2006 REVISIONS TO THE 2004 FBC AND THE 2005 NFPA-70. | | | PLEASE LIST THE FOLLOWING | | | 2004 FBC W/ 2006 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE THE MISSING PRINTED NAME AND | | | SIGNATURE OF THE DESIGNER OF RECORD IF MEETING THE | | | EXCEPTIONS UNDER FS 481.229, AND 471.003 | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 3) NOTE: PLEASE SEE FBC 2004 W/ 2006 REVISIONS R313 | | | WHICH REQUIRES ALL SMOKE ALARMS OR DETECTORS TO BE | | | BROUGHT UP TO CODE IF THE EXISTING DOES NOT MEET CODE. | | | PLEASE INDICATE WHICH TYPE OF DEVICES ARE TO BE | | | INSTALLED, EXISTINGAND LOCATIONS PER NFPA-72 | | | 11.5.1.1, 11.8.3. | | | | | | 4) NOTE: PLEASE INDICATE THE MINIMUM CIRCUITS IN | | | KITCHEN IF NEW OR EXISTING. SMALL APPLIANCE(S), 20AMP | | | #12 PER 210.52B1, 210.11C1, 220.53. | | | | | | 5) NOTE: PLEASE INDICATE THE MINIMUM REQUIRED BATH | | | DEDICATED CIRCUITS PER 210.52D, 210.11C3. | | | MUST BE 20AMP AND #12. | | | | | | 6) NOTE: PLEASE SHOW LOCATION OF THE EXISTING PANEL. | | | 110.26, 408.7, 240.24. | | | FBC 106.1.2. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-07-30 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-07-30 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2007-07-30 10:35:12 | PLANS APPROVED PREVIOUSLY, AND STAMPED AT THIS TIME. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-07-03 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-07-03 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2007-07-03 15:28:12 | ***PROVISO*** | | | | | | 1) PLEASE SEE THAT PLANS WERE APPROVED AT TIME OF FIRST | | | FIRE REVIEW. PLEASE SEE BUILDING REVIEW COMMENTS. PLANS | | | WILL BE STAMPED WHEN CORRECTIONS ARE MADE. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION 9%61) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-12 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-12 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2007-06-12 11:11:03 | *****PROVISO***** | | | | | | | | | | | | THE REMOVAL, REPLACEMENT, AND/OR STOCKING OF NEW | | | BUILDING MATERIALS & SUPPLIES SHALL IN NO WAY BLOCK, | | | INTERFERE, OR HINDER ACCESS TO OR EGRESS FROM THE SAID | | | BUILDING FLOOR OR OTHER FLOORS IN THE BUILDING | | | (INCLUDING EXITS, EXIT AISLE CORRIDORS). |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-16 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-16 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2007-07-18 10:57:48 | TO "BOB"#5 | | 2007-07-16 09:23:26 | WAITING FOR "BOB" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-19 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-19 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2007-06-20 13:37:56 | TO "BOB"#7 | | 2007-06-19 11:49:02 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-12 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-18 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2007-06-01 08:44:25 | TO "BOB"#3 | | 2007-05-18 16:19:48 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-11 |
Time |
07:59 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-06-11 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2007-06-11 08:00:02 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-01 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-01 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-01 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-27 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-27 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-09 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-09 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2007-06-09 08:47:26 | PLUMBING PLAN REVIEW OK WILL STAMP WHEN ELECTRICAL PLAN | | | REVIEW COMMENTS 1 AND 2 ARE CORRECTED. | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-23 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-23 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2007-07-23 17:32:47 | *VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|