Plan Review Details - Permit 07050659
Plan Review Stops For Permit 07050659
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-04 Cont ID  
Sent By jgomez Date 2007-05-31 Time 14:21 Rev Time 0.00
Received By jgomez Date 2007-05-31 Time 14:21 Sent To PC
Notes
2007-05-31 14:22:48WAITING FOR REVISED CONTRACTOR'S LETTER REGARADING NAIL
 ENHANCING AT PERIMETER AND CORNER AREAS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-05-17 Cont ID  
Sent By jgomez Date 2007-05-17 Time 16:28 Rev Time 0.00
Received By jgomez Date 2007-05-17 Time 16:28 Sent To PC
Notes
2007-05-17 16:39:00BUILDING REVIEW CHECKLIST:
 1- CLEARLY IDENTIFY SPECIFIC BASE SHEET FASTENING
 OPTION ON PAGE 28 OF 32 OF NOA03-0501.02 AS REQUIRED
 BY CITY POLICY FOR ROOFING PERMITS. SEE ATTACHED COPY.
  
 2- PROVIDERAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 THE PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL
 LIMITATION #7 ON PAGE 32 OF NOA SUBMITTED.
 SPECIFICATIONS WRITTEN IN THE PERMIT APPLICATION DON'T
 WORK FOR DESIGN PRESSURES AT CORNERS AND PERIMETER
 ZONES. SEE TABLE 1609.6.2.1(2)OF FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-05-30 Cont ID  
Sent By adarroug Date 2007-05-30 Time 09:17 Rev Time 0.00
Received By adarroug Date 2007-05-30 Time 09:17 Sent To B
Notes
2007-05-30 09:18:15TO "JGOMEZ" DESK/RESUB


Account Summary | Usage Policy | Privacy Policy