| Plan Review Stops For Permit 07050657 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-06-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-06-18 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-06-18 |
Time |
10:58 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-19 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-03-19 |
Time |
07:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2008-03-18 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2008-03-18 |
Time |
07:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-11-21 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-11-19 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2007-11-20 11:48:26 | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 07050657 | | | ADD: 1700 45TH STREET #1738 | | | CONT: RENOUVELLE INC | | | TEL: (561)841-0502 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 2ND | | | ACTION: DENIED | | | | | | NOTE:DUE TO THE FACT THAT TWO NEW SETS OF PLANS ARE | | | SUBMITTED, AND ONE SET OF THE OLD SET WAS NOT | | | RE-SUBMITTED, NEW COMMENTS MAY BE INCLUDED WITH THIS | | | REVIEW. | | | | | | 1A)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1B) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 1C) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC | | | BUILDING WITH THE 2007 REVISIONS. | | | | | | | | | 2)2004 FBC EXISTING | | | 301.5 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | | | | 3)THE CODE REFERENCE TO ?SAFEGUARDS DURING | | | CONSTRUCTION? IS INCORRECT. CHAPTER 13 IN THE 2004 FBC | | | IS THE ENERGY EFFICIENCY CHAPTER. SEE FBC CHAPTER 33 | | | FOR INFORMATION REGARDING ?SAFEGUARD DURING | | | CONSTRUCTION?. | | | | | | 4)INDICATE ON THE FLOOR PLAN HOW THE CASH REGISTER | | | WILL MEET THE REQUIREMENTS OF SECTION 11-7. SHOW THE | | | ELEVATION DETAIL OF THE FRONT COUNTER WHERE THE | | | CUSTOMERS WILL INTERACT WITH THE CASHIER. | | | | | | 5)SUBMIT AN EXISTING AND A PROPOSED FLOOR PLAN | | | SHOWING ALL DEMOED SYSTEMS AND ALL NEW SYSTEMS | | | INCLUDING PLUMBING, ELECTRIC, MECHANICAL AND WALLS. | | | THESE DRAWINGS WILL CLARIFY THE AREAS WHERE THE | | | PROPOSED WORK WILL TAKE PLACE. THE BUILDING OFFICIAL | | | MAY REQUIRE DETAILS AND OTHER NECESSARY DATA TO | | | DESCRIBE THE PROJECT. WILL THE NEW 6? WALL ATTACHED TO | | | THE DECK ABOVE OR THE CEILING GRID?WHEN THE WALL IS | | | CONSTRUCTED THE SPRINKLER SYSTEM WILL HAVE NO EFFECT ON | | | THE CORRIDOR CREATED. SHOW ON THE DRAWINGS HOW THIS | | | PROBLEM WILL BE RECTIFIED. | | | | | | 6)THE FLAME SPREAD AND SMOKE-DEVELOPED INDEX IN | | | ACCORDANCE WITH FBC803 AND TABLE 803.5 | | | | | | 7)THE OCCUPANT LOAD OF THE AREA SHALL BE SHOWN ON THE | | | DRAWINGS. SEE TABLE 1004.1.2 WHEN DESIGNING THE | | | OCCUPANT LOAD. | | | | | | 8)TWO COMPLETE SETS OF CONSTRUCTION DOCUMENTS SHALL | | | BE PREPARED BY THE DESIGN PROFESSIONAL FOR REVIEW. ONE | | | SET OF THE DRAWINGS IS A PHOTO-COPY SET. THE RAISED | | | SEAL OF THE ENGINEER IS MISSING FROM THE DRAWINGS. | | | SUBMIT TWO SETS OF DRAWINGS WITH THE ORIGINAL SEAL, | | | SIGNATURE AND DATE OF THE ENGINEER OF RECORD. FBC | | | 106.1. | | | | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-06 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-06 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2007-06-06 16:20:42 | BUILDING PLAN REVIEW | | | PERMIT: 07050657 | | | ADD: 1700 45TH STREET. #1738 | | | CONT: RENOUVELLE, INC. | | | TEL: (561)201-6706 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3)FBC 11-7.2(1) IN DEPARTMENT STORES AND | | | MISCELLANEOUS RETAIL STORES WHERE COUNTERS HAVE CASH | | | REGISTERS AND PROVIDED FOR SALES OR DISRTIBUTION OF | | | GOODS OR SERVICES TO THE PUBLIC, AT LEAST ONE OF EACH | | | TYPE SHALL HAVE A PORTION OF THE COUNTER WHICH IS AT | | | LEAST 36 INCHES ABOVE THE FINISH FLOOR. PROVIDE AN | | | ELEVATION DETAIL MEETING THE REQUIREMENTS OF SECTION | | | 11-7. | | | | | | 4)SHOW A WALL DETAIL OF THE NEW WALL TO BE | | | CONSTRUCTED. THE WALL TYPES INDICATE A 1HR FIRE RATING, | | | PROVIDE A UL DESIGN FOR THE 1HR WALL TYPE. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE NATURE AND CLARITY OF THE WORK. | | | 106.1.1. | | | | | | 5) ADDITIONAL INFORMATION WILL BE REQUIRED FOR THE | | | HOOD. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2008-03-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2008-03-17 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2008-03-17 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-13 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-13 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2007-11-13 08:28:16 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | ALL COMMENTS RELATE TO SHEETS E-1 AND E-2, UNLESS | | | OTHERWISE NOTED. ALL CODE ARTICLES REFERENCED ARE 2005 | | | NEC UNLESS OTHERWISE NOTED. | | | THESE ARE NEW COMMENTS THIS REVIEW BROUGHT FROM THE | | | PANEL SCHEDULE SUBMITTED. | | | | | | 1} CIRCUIT #11 IS MARKED AS APPLIANCE ON THE SCHEDULE, | | | BUT SHOWN ON E-1 AS OUTLET FOR HOOD. CORRELLATE SAME. | | | | | | 2} AIR HANDLER CIRCUIT 2,4 ON THE SCHEDULE, NOT LOCATED | | | ON SHEET E-1. | | | | | | 3} THE DOUGH MIXER CIRCUIT 8,10 ON THE SCHEDULE, NOT | | | LOCATED ON E-1. | | | | | | 4} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471 | | | FS, RESPECTIVELY. | | | | | | PLEASE REMOVE OLD SHEETS, INSERT NEW ONES, SUBMIT OLD | | | SHEETS TO EXPEDITE REVIEW AND SUBMIT WRITTEN RESPONSE | | | TO THE COMMENTS MADE IN THIS REVIEW. | | | | | | FOR RECORD RETENTION PER 106.5 FBC, AND CLARITY IN THE | | | FIELD WHEN WORKING FROM THIS DOCUMENT, PLEASE INDICATE | | | THE CODE CYCLES UNDER WHICH THIS PLAN WAS DESIGNED. | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-01 |
Time |
13:49 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-06-01 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2007-06-01 13:49:40 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} STANDARD 120 AMP OUTLETS ARE INDICATED ON A 30 AMP | | | BREAKER, CIRCUIT #11. ALSO THE 14 AMP HOOD IS SHOWN ON | | | THAT CIRCUIT. 210.23(B). | | | | | | 2} PLEASE INDICATE THE CIRCUIT NUMBERS AT THE DEVICES. | | | 106.3.5.1 FBC AS AMENDED. | | | | | | 3} INDICATE THE CIRCUIT NUMBERS FOR THE LIGHTS SO THAT | | | COMPLIANCE WITH 700.12(F)(4) FOR THE EMERGENCY | | | FIXTURES, CAN BE REVIEWED. | | | | | | AN ELECTRICAL PERMIT IS REQUIRED PER 105.1 FBC AS | | | AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-03-18 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-03-18 |
Time |
15:56 |
Sent To |
B1 |
|
| Notes |
| 2008-03-18 16:01:46 | *****APPROVED***** | | | | | | PLAN SHEETS A-2 AND E-1 WERE STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-11-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-20 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-20 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2007-11-20 14:54:18 | ******UNSAT***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLEASE BE ADVISED HOWEVER, THAT SHEETS | | | (A-1, A-2, PLBG-1, E-1, E-2) OF ONE SET OF PLANS ARE | | | COPIES OF THE SIGN AND SEAL WHICH IS NOT ACCEPTABLE. | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | | THIS ISSUE AS WELL AS THE OTHER REVIEWERS HAVE BEEN | | | SATISFIED. | | | | | | | | | | | | | | | | | | | | | CAPT. MICHEAL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-12 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-12 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2007-06-12 10:41:09 | ******DENIED***** | | | | | | | | | 1.THE SUBMITTED PLANS DO NOT INDICATE WHAT THE | | | MODIFICATIONS TO THE EXISTING STRUCTURE ARE TO BE | | | CONDUCTED.IS THIS A CHANGE OF OCCUPANCY?DOES THE | | | OCCUPANCY HAVE FIRE SPRINKLER AND/OR FIRE ALARM | | | DEVICES? | | | | | | 2.THE 2003 EDITION OF NFPA 101 AND THE 2004 EDITION | | | OF THE FLORIDA FIRE PREVENTION CODE SHALL BE | | | REFERENCED. | | | | | | 3.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 4.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE THE SITE AT THE END OF EACH SHIFT | | | OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 5.THE REMOVAL AND/OR REPLACEMENT OF BUILDING | | | MATERIALS & SUPPLIES SHALL NOT INTERFERE OR HINDER | | | EMERGENCY RESPONSE ACCESS TO THE PROPERTY OR VICINITY | | | THEREOF (INCLUDING FIRE LANES). | | | | | | 6.IF THE BUILDING OR PORTION OF THE BUILDING IS TO BE | | | OCCUPIED DURING THE SCOPE OF WORK, REQUIRED MEANS OF | | | EGRESS AND REQUIRED FIRE PROTECTION FEATURES SHALL BE | | | OPERATIONAL AND MAINTAINED. | | | | | | 7.BASED UPON THE OCCUPANCY TYPE, INDICATE THE | | | INTERIOR WALL AND CEILING MATERIALS IN EXITS, EXIT | | | ACCESS CORRIDORS, AND IN ALL OTHER AREAS.BE SPECIFIC | | | AS TO CLASS A, CLASS B, OR CLASS C. | | | | | | 8.PROVIDE LOCATION OF THE 2A:10BC RATED FIRE | | | EXTINGUISHER(S) SATISFYING THE 75' TRAVEL DISTANCE. | | | | | | 9.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE | | | HOOD'S SUPPRESSION SYSTEM | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHEAL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-14 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-14 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-27 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-27 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2007-11-27 10:06:26 | DENIED; | | | 1. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. | | | 2. TYPE OF GAS, (LP OR NATURAL) | | | 3. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | 4. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-16 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-16 |
Time |
13:54 |
Sent To |
M |
|
| Notes |
| 2008-06-16 13:55:05 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-16 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-16 |
Time |
13:51 |
Sent To |
B |
|
| Notes |
| 2008-06-16 13:52:09 | TO "MJACOBS" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-12 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-12 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2008-03-12 16:20:29 | TO "BOB"#4 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-07 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-07 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2007-11-07 12:47:02 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-12 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-17 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2007-05-29 14:12:54 | TO "BOB"#10 | | 2007-05-17 16:49:23 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-16 |
Time |
16:01 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-06-16 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2008-06-16 16:01:54 | REVISION TO KITCHEN HOOD PLAN. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-13 |
Time |
09:49 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-03-13 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2008-03-13 09:51:44 | ADDITIONAL MECHANICAL PERMITS REQUIRED FOR | | | (A) KITCHEN HOOD (PLANS W/MASTER) | | | (B) FIRE SUPPRESSION | | | ** SUBMIT PLANSFOR FIRE SUPPRESSION WITH PERMIT | | | APPLICATION. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-09 |
Time |
13:52 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2007-11-09 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2007-11-09 14:35:14 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) BE ADVISED MOST SHEETS IN ONE SET OF PLANS HAVE NOT | | | BEEN SIGNED AND SEALED BUT ARE COPIES THESE ARE NOT | | | ACCEPTABLE, SEE FAC 61G15-23.002. PLEASE CORRECT. | | | | | | 2) PLANS PAGE A-1 SHOWS THE HOOD EXHAUST DUCT AS | | | 24"X24" IF THE EXHAUST FAN IS 3000 CFM'S THAT WOULD PUT | | | THE AIR VELOCITY AT 750 FPM. PER 2004 FBC/M 506.3.4 AIR | | | VELOCITY. | | | GREASE DUCT SYSTEMS SERVING A TYPE I HOOD SHALL BE | | | DESIGNED AND INSTALLED SO AS TO PROVIDE AN AIR VELOCITY | | | WITHIN THE DUCT SYSTEM OF NOT LESS THAN 1,500 FEET PER | | | MINUTE AND NOT GREATER THAN 2,500 FEET PER MINUTE. | | | PLEASE CORRECT. | | | | | | 3) IF THE HOOD IS U.L. APPROVED THEN PUT THE U.L. | | | APPROVAL NUMBER ON THE PLAN. IF NOT SHOW COMPLIANCE | | | WITH 2004 FBC/M 507. | | | | | | 4) SHOW SUPPLY AND EXHAUST DUCTS WITH DUCT SIZES AND | | | TYPE OF MATERIALS, FROM THE HOOD TO THE FANS ON THE | | | ROOF, SEE FBC/M 506.3.4. | | | | | | 5) SHOW ON PLAN DISTANCE FROM ROOF TO EXHAUST FAN | | | OUTLET, SEE 506.3.12.1. | | | | | | 6) SHOW ON PLAN DISTANCE BETWEEN EXHAUST FAN OUTLET TO | | | SUPPLY FAN INLET, SEE NFPA 96(7.8.2). | | | | | | 7) PLEASE ADD A DETAIL TO THE PLAN SHOWING HOW THE | | | SUPPLY AND EXHAUST FANS ARE TO BE SECURED TO THE ROOF | | | TO WITHSTAND 140 MPH WINDS IN COMPLIANCE WITH 2004 FBC | | | 1609. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-11 |
Time |
08:18 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-06-11 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2007-06-11 08:44:48 | *** DENIED *** | | | 1) PLEASE SUBMIT ENGINEERING FOR KITCHEN EXHAUST HOOD | | | WITH ALL PERTINENT INFORMATION SPECIFIC TO THIS JOB, | | | SPECIFICATION SHEETS ARE TO GENERIC. | | | | | | 2) SHOW ANCHORING DETAIL FOR FANS AND HANGING DETAIL | | | FOR HOOD. | | | | | | 3) SHOW LOCATION OF EXHAUST FAN AND SUPPLY FAN. | | | | | | 4) BE ADVISED ADDITIONAL PERMITS WILL BE REQUIRED FOR | | | KITCHEN HOOD AND FIRE SUPPRESSION. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-03-14 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-03-14 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-11-27 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-11-27 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2007-11-27 09:47:42 | DENIED; | | | COMMENTS FROM LAST REVIEW 1 THRU 8 OK MEANS COMMENT WAS | | | ADDRESSED NO MEANS NOT ADDRESSED. | | | 1. OK | | | 2. NO; GREASE TRAP WILL BE SIZED BY THE CITY OF WPB | | | UTILITYDEPARTMENT BEFORE PLANS ARE APPROVED BY THE | | | PLAN REVIEW ( PLUMBING). | | | 3. NO; 3 COMPARTMENT SINK ISSHOWN ON SANITARY RISER | | | DIAGRAM DIRECTLY TIDE INTO THE SANITARY SYSTEM. | | | 4. OK | | | 5. NO; CAN WASH WASTE IS SHOWN GOING TO SANITARY (GOOD) | | | BUT AS DRAWN DRAN DOES NOT GO THRU GREASE TRAP AS | | | REQUIRED. | | | 6. YES, NO; NOTE ADDED BUT MOP SINK NOT VENTED AS | | | DRAWN. | | | 7. YES, NO; THE BACKFLOW PERVENTOR FOR THE SHOPPING | | | CENTER IS FOR THE CITY'S PROTECTION. A RPZ IS REQUIRED | | | FOR THE RESTAURANT FOR ADDITIONAL PROTECTION. | | | 8. NO; PIPE SIZING IS NOT COMPLETE ON RISER DIAGRAM. | | | NEW COMMENTS | | | 9. BATHROOM LAVATORY NOT SHOWN ON RISER DIAGRAM. | | | 10. WATER RISER DIAGRAM; GAVANIZED PIPE IS NOT A COMMON | | | USED WATER PIPING MATERIAL. COPPER OR CPVC ARE USED IN | | | THIS AREA. | | | 11. GAS RISER ADDED TO PLANS SEE COMMENTS UNDER THE GAS | | | STOP. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-09 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-09 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2007-06-09 08:22:55 | DENIED; | | | 1.PLANS ARE REQUIRED TO BE APPROVED BY THE DEPARTMENT | | | OF BUSINESS AND PROFESSIONAL REGULATION DIVISION OF | | | HOTEL AND RESTAURANTS. INFORMATION REQUIRED CAN BE | | | FOUND AT | | | TTP://WWW.MYFLORIDA.COM/DBPR/HR/FORMS/INDEX.SHTML. | | | PLANS MUST BE STAMP AND REPORT ATTACHED TO PLANS FROM | | | DPR BEFORE RESUB TO BUILDING DEPARTMENT. | | | 2. ALL GREASE TRAP INSTALLATIONS MUST BE APPROVED BY | | | WPB UTILITIES DEPARTMENT. PLEASE CONTACT RODNEY COMPO | | | 822-2272 OR CALVN WILLIAMS 822-2284. | | | 3. THE 2 COMPARTMENT SINK SHOULD BE A 3 COMPARTMENT, | | | HEALTH DEPARTMENT REQUIREMENT. THE SINK SHALL BEAN | | | INDURECT WASTE SEE FBC-2004 PLUMBING SECTION 802.1. | | | 4. 20% OF COST OF JOB SHALL BE USED TO MAKE THE SHOP | | | ACCESSIBLE. PLEASE SHOW WHAT WORK WILL BE DONE AND | | | ESTIMATEDCOST ON PLANS. | | | 5. CAN WASH SHALL DRAIN TO GREASE WASTE. DRAIN FIELD | | | NOT PERMITED. SECTION 701.2. | | | 6. PLUMBING NOTES #6 CHANGE THE SECTION, (NO MORE THAN | | | 15' FROM VENTEDSEWER) TO "SHALL COMPLY WITH FBC-2004 | | | PLUMBING TABLE 906.1. | | | 7. A REDUCED PRESSURE BACKFLOW PREVENTER IS REQUIRED ON | | | WATER SERVICE. IF ONE EXISTS STATE ON PLANS IF NOT SHOW | | | ON WATER RISER. | | | 8. SIZE ALL DRAINAGE PIPE ON RISER DIAGRAM. | | | PLUMBING PLAN REV BY; | | | JOHN LEECH | | | 805-6695 |
|
|