Plan Review Details - Permit 07050635
Plan Review Stops For Permit 07050635
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-07-18 Cont ID  
Sent By mjacobs Date 2007-07-18 Time 10:35 Rev Time 0.00
Received By mjacobs Date 2007-07-18 Time 07:43 Sent To PC
Notes
2007-07-18 10:52:16BUILDING PROVISO:
 TO BE IN PLACE AT C.O.
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-18 Cont ID  
Sent By mjacobs Date 2007-06-18 Time 14:48 Rev Time 0.00
Received By mjacobs Date 2007-06-15 Time 18:35 Sent To PC
Notes
2007-06-15 18:52:24BUILDING PLAN REVIEW
 PERMIT: 07050635
 ADD:7130 WINDING BAY LN
 CONT: AAA CUSTOM POOLS INC.
 TEL: (561)493-8841
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 2)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME,
 ADDRESS, AND LICENCE NUMBER ON EACH SHEET THAT BEARS
 THEIR SEAL PER 61G15-23.002(2) SEE SHEET 1A.
  
 3)THE VANISHING EDGE DETAIL NEEDS MORE DETAILS
 SHOWING A DISTANCE NO LESS THAN 48 INCHES FROM THE
 POOL'S EDGE TO THE LOWER SECTION OF THE WALL. SEE THE
 MARKE PLAN SET.
  
 4)WHAT IS THE DEPTH OF THE AUX. POOL/SPA. INDICATE
 THE TYPE OF POOL ENCLOSURE / BARRIER TO MEET THE
 REQUIREMENTS OF SEC.4101.17
  
 5)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL COST EXCLUDING LAND
 VALUE. OUR VALUATION REFERENCE IS ICC (BVD)
 MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-07-09 Cont ID  
Sent By btrobaug Date 2007-07-09 Time 06:59 Rev Time 0.00
Received By btrobaug Date 2007-07-09 Time 06:29 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-05-29 Cont ID  
Sent By btrobaug Date 2007-05-29 Time 10:32 Rev Time 0.25
Received By btrobaug Date 2007-05-29 Time 10:05 Sent To P
Notes
2007-05-29 10:32:00 
  
 DENIED/INCOMPLETE INFORMATION
  
 THERE IS AN ELECTRICAL "PANEL" SHOWN ON THE ELECTRICAL
 SCHEMATIC. THIS WOULD APPEAR TO BE A "POOL PANEL". IF
 IT IS EXISTING PLEASE INDICATE ON THE PLAN. IF IT IS
 BEING INSTALLED AS PART OF THIS PERMIT, SUBMIT THE
 FOLLOWING DETAILS ON THE PLAN: FEEDER SIZE AND OCP,
 GROUND PER 250.122 OR 250.66 IF ON A SEPARATE
 STRUCTURE.
  
 INDICATE COMPLIANCE WITH ARTICLE 680.26 FOR
 EQUIPOTENTIAL BONDING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2007-07-16 Cont ID  
Sent By mperson Date 2007-07-16 Time 08:40 Rev Time 0.00
Received By mperson Date 2007-07-16 Time 08:40 Sent To B
Notes
2007-07-16 08:42:42CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
  
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-06-06 Cont ID  
Sent By mperson Date 2007-06-06 Time 11:29 Rev Time 0.00
Received By mperson Date 2007-06-06 Time 11:29 Sent To B
Notes
2007-06-06 11:31:45CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-02 Cont ID  
Sent By adarroug Date 2007-08-02 Time 15:58 Rev Time 0.00
Received By adarroug Date 2007-08-02 Time 15:58 Sent To Z
Notes
2007-08-02 15:59:07TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-06 Cont ID  
Sent By adarroug Date 2007-07-06 Time 11:07 Rev Time 0.00
Received By adarroug Date 2007-07-06 Time 11:07 Sent To Z
Notes
2007-07-06 11:08:04TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-23 Cont ID  
Sent By adarroug Date 2007-05-23 Time 13:44 Rev Time 0.00
Received By adarroug Date 2007-05-23 Time 13:44 Sent To E
Notes
2007-05-23 13:44:55TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-06-18 Time   Rev Time 0.00
Received By adarroug Date 2007-05-17 Time 14:49 Sent To  
Notes
2007-05-17 14:50:06TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-07-16 Cont ID  
Sent By mperson Date 2007-07-16 Time 08:18 Rev Time 0.33
Received By mperson Date 2007-07-16 Time 08:18 Sent To G
Notes
2007-07-16 08:38:08****************PROVISO****************
 A) FBC-2004 SEC. 424.2.12.1, OR
 FBCR-2004 SEC. R4101.12.1 PRESSURE
 TESTS. PER MANUFACTURE RECOMMENDATIONS,
 NO AIR TEST SHALL BE APPROVED FOR PVC
 PIPE AND FITTINGS. (ADD TO NOTES)
 B) FBC-2004 SEC. 424.2.13.2, OR
 FBCR-2004 SEC.R4101.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING.(ADD TO
 NOTES)
 C) NOTE: AUTO WATER FILL, TEST REQUIRED PER FBC-2004
 PLUMBING, SECTION 312.5. HOOK-UP BY LICENSED PLUMBING
 CONTRACTOR, PERMIT REQUIRED.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS REVIEWER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-06-06 Cont ID  
Sent By mperson Date 2007-06-06 Time 11:11 Rev Time 0.45
Received By mperson Date 2007-06-06 Time 11:11 Sent To G
Notes
2007-06-06 11:29:24DENIED
 REFERENCE:
 ** FBC-2004 SECTIONS 424.2 AND R4101 SWIMMING POOLS.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET 1A OF 3 IS MISSING THE FOLLOWING REQUIRED BY
 THE ENGINEER:
 106.1 SUBMITTAL DOCUMENTS. IF THE DESIGN PROFESSIONAL
 IS AN ENGINEER
 LEGALLY REGISTERED UNDER THE LAWS OF
 THIS STATE REGULATING THE PRACTICE OF
 ENGINEERING AS PROVIDED FOR IN CHAPTER
 471, FLORIDA STATUTES, THEN HE OR SHE
 SHALL AFFIX HIS OR HER SEAL, SIGNATURE
 AND DATE TO SAID DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA, AS
 REQUIRED BY FLORIDA STATUTES.
 PLEASE CORRECT THIS SHEET ON THE RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 3 Status P Date 2007-08-03 Cont ID  
Sent By choops Date 2007-08-03 Time 13:51 Rev Time 0.00
Received By choops Date 2007-08-03 Time 13:51 Sent To PC
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2007-07-06 Cont ID  
Sent By choops Date 2007-07-06 Time 14:28 Rev Time 0.00
Received By choops Date 2007-07-06 Time 14:28 Sent To E
Notes
2007-07-06 14:32:33***FAILED***
  
  
 1)AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE
 SURROUNDING THE POOL, A FENCE PERMIT SHALL BE SUBMITTED
 CONCURRENTLY AND SHALL CONFORM TO THE MINIMUM STANDARDS
 PROVIDED BELOW.
  
 AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS, SECTION 94-304(D)(2)(B)+(C):
  
 B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE
 OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT
 ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF
 THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
 C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE
 THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND
 SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR
 WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF
 GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL
 SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH
 WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT
 SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-05-23 Cont ID  
Sent By choops Date 2007-05-23 Time 09:02 Rev Time 0.00
Received By choops Date 2007-05-23 Time 09:02 Sent To I
Notes
2007-05-23 09:04:22***FAILED***
  
  
 1)***DRIVEWAY NOT UNDER THIS PERMIT***
  
 2)PLEASE SHOW POOL EQUIPMENT ON BOTH THE SURVEYS AND
 SITE PLANS, WITH DIMENSIONS AND SETBACK DIMENSIONS TO
 PROPERTY LINES.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720