| Plan Review Stops For Permit 07050635 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-18 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-18 |
Time |
07:43 |
Sent To |
PC |
|
| Notes |
| 2007-07-18 10:52:16 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O. | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-18 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-15 |
Time |
18:35 |
Sent To |
PC |
|
| Notes |
| 2007-06-15 18:52:24 | BUILDING PLAN REVIEW | | | PERMIT: 07050635 | | | ADD:7130 WINDING BAY LN | | | CONT: AAA CUSTOM POOLS INC. | | | TEL: (561)493-8841 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME, | | | ADDRESS, AND LICENCE NUMBER ON EACH SHEET THAT BEARS | | | THEIR SEAL PER 61G15-23.002(2) SEE SHEET 1A. | | | | | | 3)THE VANISHING EDGE DETAIL NEEDS MORE DETAILS | | | SHOWING A DISTANCE NO LESS THAN 48 INCHES FROM THE | | | POOL'S EDGE TO THE LOWER SECTION OF THE WALL. SEE THE | | | MARKE PLAN SET. | | | | | | 4)WHAT IS THE DEPTH OF THE AUX. POOL/SPA. INDICATE | | | THE TYPE OF POOL ENCLOSURE / BARRIER TO MEET THE | | | REQUIREMENTS OF SEC.4101.17 | | | | | | 5)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL COST EXCLUDING LAND | | | VALUE. OUR VALUATION REFERENCE IS ICC (BVD) | | | MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER | | | 108.3 FBC* | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-09 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-09 |
Time |
06:29 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-05-29 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-29 |
Time |
10:32 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2007-05-29 |
Time |
10:05 |
Sent To |
P |
|
| Notes |
| 2007-05-29 10:32:00 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | THERE IS AN ELECTRICAL "PANEL" SHOWN ON THE ELECTRICAL | | | SCHEMATIC. THIS WOULD APPEAR TO BE A "POOL PANEL". IF | | | IT IS EXISTING PLEASE INDICATE ON THE PLAN. IF IT IS | | | BEING INSTALLED AS PART OF THIS PERMIT, SUBMIT THE | | | FOLLOWING DETAILS ON THE PLAN: FEEDER SIZE AND OCP, | | | GROUND PER 250.122 OR 250.66 IF ON A SEPARATE | | | STRUCTURE. | | | | | | INDICATE COMPLIANCE WITH ARTICLE 680.26 FOR | | | EQUIPOTENTIAL BONDING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-16 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-07-16 |
Time |
08:40 |
Sent To |
B |
|
| Notes |
| 2007-07-16 08:42:42 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-06 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-06-06 |
Time |
11:29 |
Sent To |
B |
|
| Notes |
| 2007-06-06 11:31:45 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-02 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-02 |
Time |
15:58 |
Sent To |
Z |
|
| Notes |
| 2007-08-02 15:59:07 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-06 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-06 |
Time |
11:07 |
Sent To |
Z |
|
| Notes |
| 2007-07-06 11:08:04 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-23 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-23 |
Time |
13:44 |
Sent To |
E |
|
| Notes |
| 2007-05-23 13:44:55 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-06-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-17 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2007-05-17 14:50:06 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-16 |
Time |
08:18 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-07-16 |
Time |
08:18 |
Sent To |
G |
|
| Notes |
| 2007-07-16 08:38:08 | ****************PROVISO**************** | | | A) FBC-2004 SEC. 424.2.12.1, OR | | | FBCR-2004 SEC. R4101.12.1 PRESSURE | | | TESTS. PER MANUFACTURE RECOMMENDATIONS, | | | NO AIR TEST SHALL BE APPROVED FOR PVC | | | PIPE AND FITTINGS. (ADD TO NOTES) | | | B) FBC-2004 SEC. 424.2.13.2, OR | | | FBCR-2004 SEC.R4101.13.2 JOINTS AND | | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | | PRIMER REQUIRED ON PVC PIPING.(ADD TO | | | NOTES) | | | C) NOTE: AUTO WATER FILL, TEST REQUIRED PER FBC-2004 | | | PLUMBING, SECTION 312.5. HOOK-UP BY LICENSED PLUMBING | | | CONTRACTOR, PERMIT REQUIRED. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS REVIEWER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-06 |
Time |
11:11 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-06-06 |
Time |
11:11 |
Sent To |
G |
|
| Notes |
| 2007-06-06 11:29:24 | DENIED | | | REFERENCE: | | | ** FBC-2004 SECTIONS 424.2 AND R4101 SWIMMING POOLS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SHEET 1A OF 3 IS MISSING THE FOLLOWING REQUIRED BY | | | THE ENGINEER: | | | 106.1 SUBMITTAL DOCUMENTS. IF THE DESIGN PROFESSIONAL | | | IS AN ENGINEER | | | LEGALLY REGISTERED UNDER THE LAWS OF | | | THIS STATE REGULATING THE PRACTICE OF | | | ENGINEERING AS PROVIDED FOR IN CHAPTER | | | 471, FLORIDA STATUTES, THEN HE OR SHE | | | SHALL AFFIX HIS OR HER SEAL, SIGNATURE | | | AND DATE TO SAID DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA, AS | | | REQUIRED BY FLORIDA STATUTES. | | | PLEASE CORRECT THIS SHEET ON THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-03 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-03 |
Time |
13:51 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-06 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-06 |
Time |
14:28 |
Sent To |
E |
|
| Notes |
| 2007-07-06 14:32:33 | ***FAILED*** | | | | | | | | | 1)AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE | | | SURROUNDING THE POOL, A FENCE PERMIT SHALL BE SUBMITTED | | | CONCURRENTLY AND SHALL CONFORM TO THE MINIMUM STANDARDS | | | PROVIDED BELOW. | | | | | | AS PER THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION 94-304(D)(2)(B)+(C): | | | | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-23 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-23 |
Time |
09:02 |
Sent To |
I |
|
| Notes |
| 2007-05-23 09:04:22 | ***FAILED*** | | | | | | | | | 1)***DRIVEWAY NOT UNDER THIS PERMIT*** | | | | | | 2)PLEASE SHOW POOL EQUIPMENT ON BOTH THE SURVEYS AND | | | SITE PLANS, WITH DIMENSIONS AND SETBACK DIMENSIONS TO | | | PROPERTY LINES. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|