Plan Review Details - Permit 07050618
Plan Review Stops For Permit 07050618
Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2008-10-01 Cont ID  
Sent By jgomez Date 2008-10-01 Time 10:55 Rev Time 0.00
Received By jgomez Date 2008-10-01 Time 10:55 Sent To E
Notes
2008-10-01 10:57:12BUILDING REVISION: POOL DECK ADDED TO PERMIT VALUATION.
 PLANS SENT TO ELECTRICAL FOR DECK BONDING REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2008-08-01 Cont ID  
Sent By jgomez Date 2008-08-01 Time 14:43 Rev Time 0.00
Received By jgomez Date 2008-08-01 Time 14:42 Sent To PC
Notes
2008-08-01 14:43:33INSULATION REVISION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2008-07-25 Cont ID  
Sent By jgomez Date 2008-07-25 Time 09:43 Rev Time 0.00
Received By jgomez Date 2008-07-25 Time 09:39 Sent To PC
Notes
2008-07-25 09:49:09RESIDENTIAL (R3) ADDITION, BUILDING REVISION
 CHECKLIST.
 REVIEW UNDER FBC 2004.
  
 1- ARCHITECT NEEDS TO REVISE PLANS TO REFLECT THE
 CHANGE OF INSULATION SINCE PROPOSED INSULATION ALTERS
 THE BUILDING VENTILATION REQUIREMENTS OF SEC. R806 OF
 2004 FLORIDA RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-11-05 Cont ID  
Sent By jgomez Date 2007-11-05 Time 10:55 Rev Time 0.00
Received By jgomez Date 2007-11-05 Time 07:34 Sent To PC
Notes
2007-11-05 10:58:57RESIDENTIAL ADDITION BUILDING REVIEW PROVISO.
 1- ARCHITECT TO REVISE THE LETTER LISTING THE APPROVED
 PRODUCT APPROVALS. REVIEW PRODUCT APPROVAL PACKAGE AND
 CORRECTLY LIST SPECIFIC NOA OR FLORIDA PRODUCT APPROVAL
 NUMBER.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-10-18 Cont ID  
Sent By jgomez Date 2007-10-18 Time 10:36 Rev Time 0.00
Received By jgomez Date 2007-10-18 Time 07:42 Sent To PC
Notes
2007-10-18 10:49:08RESIDENTIAL ADDITION BUILDING REVIEW THIRD CHECKLIST.
 REVIEW UNDER EXISTING BUILDING 2004, FLORIDA
 RESIDENTIAL BUILDING CODE 2004 AND FBC 2004.
  
 1- PLANS WERE REVISED. REVISE THE ENERGY CALCULATIONS
 AS REQUIRED TO MATCH NEW PROPOSED PLANS.SEC. 13-600
 FBC 2004.
  
 2- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) SINGLE HUNG WINDOWS. FLORIDAPRODUCT APPROVAL
 FL239 AND NOA 02-0719.05 DON'T CORRESPOND TO EACH
 OTHER.GO TO WWW.FLORIDABUILDING.ORG AND DOWNLOAD
 CORRESPONDING NOA THAT WAS SUBMITTED FOR APPROVAL.
  
 B) WOOD CONNECTORS NOA 02-0919.05 IS EXPIRED.
  
 C) ALL SIMPSON PRODUCT APPROVALS SPECIFIED ON ANCHOR
 SCHEDULE AND DETAILS.
  
 D) ENTRY DOOR WITH SIDELITE ASSEMBLY AS SHOWN ON
 PLANS.
  
 E) METAL ROOFING.TABLE A ON PAGE 3 OF 5 OF NOA
 05-0331.01 SUBMITTEDINDICATES MAXIMUM DESIGN
 PRESSURES OF -55PSF IN ROOF FIELD AREA.THIS DOESN'T
 MEET THE DESIGN PRESSURES SHOWN ON TABLE R301.2(2) OF
 2004 FLORIDA RESIDENTIAL CODE.DESIGNER MAY ELECT TO
 USE THE METAL ROOF FASTENER SPACING USED FOR PERIMETER
 AND CORNER AREAS OR PROVIDE CALCULATIONS SHOWINGNAIL
 FASTENER SPACING TO ENHANCE THE DESIGN PRESSURES IN
 FIELD AREA. PROVIDE RESPONSE IN WRITING IN THE
 CONSTRUCTION DRAWINGS. SEC. 106.1.2 CITY AMENDMENTS TO
 FBC 2004.
  
 F) ROOF TILE ADHESIVE. SEE TILE PRODUCT APPROVAL FOR
 LISTED ADHESIVES. (REPEAT COMMENT).
  
 3- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING. ARCHITECT CAN'T SIGN AND SEAL
 THE WORK OF ANOTHER PROFESSIONAL)ALL PRODUCT
 APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS
 TO FBC 2004.DESIGNER MAY USETHE STANDARD SHOP
 DRAWINGS REVIEW STAMP.OR PROVIDE DESIGNER INFORMATION
 IN WRITING ALONG WITH THE REVIEW AND APPROVED LANGUAGE.
 (REPEAT COMMENT)
 ***NOTE: MAKE SURE ALL PRODUCT APPROVALS ARE APPROVED.
  
 4- PROVIDE COMPLETE SPECS FOR BBQ GRILL TO BE INSTALLED
 IN THE PORCH AREA.SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004. ARCHITECT'S RESPONSE LETTER STATED THAT THE GRILL
 WAS OMITTED, BUT DRAWINGS STILL SHOW THE GRILL. REVISE
 DRAWINGS AS REQUIRED OR PROVIDE COMPLETE GRILL'S
 INFORMATION.
  
 5- CLEARLY SPECIFY ALL DEAD AND LIVE LOADS. INFORMATION
 ON SHEET S.1 AND S.3 DOESN'T MATCH.PROVIDE
 CALCULATIONS SHOWING HOW OBTAINING THE TC DEAD LOAD OF
 07PSF?. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
 DESIGNER OF RECORD TO REVIEW SEC. R301.1,R301.4,
 R301.5,R301.6 AND R301.7 OF 2004 FLORIDA RESIDENTIAL
 CODE AND PROVIDE REQUIRED DESIGN INFORMATION AS
 REQUIRED.
 ALSO, CLARIFY INFORMATION GIVEN FOR ADDITIONAL LOADS ON
 SHEET S.3. WHERE ARE THE REFERENCE TABLES TAKEN FROM?.
 WHY ARE THERE NON-CONCURRENT BC LLOF 10PSF AND
 CONCURRENT BC STORAGE LL OF 20PSF.WHAT'S THE
 NON-CONCURRENT BC MOVING LL?.PROVIDE COMPLETE
 ENGINEERING ANALYSISAND DEMONSTRATE WHYAND WHEN
 THE LOADS ARE CONCURRENT OR NON CONCURRENT.SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
 PLEASE RETURN REVIEWED SET AFTER CORRECTIONS ARE DONE
 TO EXPEDITE THE REVIEW PROCESS.
  
 6- SOIL TEST REPORT SUBMITTED REQUIRES THE FOLLOWING:
 ENGINEERING FIRM CERTIFICATE THE AUTHORIZATION NUMBER
 IN ALL SHEETS AS REQUIRED BY SEC. 61G15-23.002 OF
 FLORIDA ADMINISTRATIVE CODE. (REPEAT COMMENT).
  
 7- REVIEW AND REVISECOMPLETE LINTEL SCHEDULE.SOME
 SIZES OF LINTELSSPECIFIEDIS THE SAME SIZE AS THE
 OPENING. THIS IS NO GOOD BECAUSE LINTEL NEED TO HAVE
 4"MIN. BEARING AT BOTH ENDS AS REQUIRED BYACI 530ASCE
 5/TMS 402.SEC. R606.1 2004 FLORIDA RESIDENTIAL CODE.
  
 8- PROVIDE SPECIFICATIONS FOR GARAGE DOORS LEADING TO
 THE EXERCISE AREA ND INTERIOR OF HOUSE AS REQUIRED BY
 SEC. R309.1 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 9- REVISE SIZE OF HOLES SPECIFIED FOR ALL CUSTOM MADE
 STEEL CONNECTORS FOR WOOD COLUMNS. THE HOLE SIZE CAN'T
 BE THE SAME SIZE DIAMETER AS THE SPECIFIED BOLT.SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-15 Cont ID  
Sent By jgomez Date 2007-08-15 Time 11:20 Rev Time 0.00
Received By jgomez Date 2007-08-15 Time 10:50 Sent To Z
Notes
2007-08-15 12:08:01RESIDENTIAL ADDITION BUILDING REVIEW SECOND CHECKLIST:
 REVIEW DONE UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC
 2004 WITH 2006 REVISIONS.
  
 1- NEED TO ADDRESS ZONING COMMENTS REGARDING SETBACKS.
 PLANS REVISIONS MAY BE REQUIRED. SEE ZONINGCOMMENTS.
  
 2- PER SEC. 713.13 FLORIDA STATUTE NOTICE OF
 COMMENCEMENT EXPIRES AFTER 90 DAYS OF RECORDING IF WORK
 IS NOT STARTED. NOC EXPIRES ON 8-15-07. WILL NEED TO
 PROVIDE RE- RECORDED NOTICE OF COMMENCEMENT.
  
 3- PROVIDE COPY OF IMPACT FEES PAID RECEIPT AS
 REQUESTED ON PREVIOUS CHECKLIST.
  
 4- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) GARAGE DOORS THAT MATCH DOORS SHOWN ON
 ARCHITECTURAL ELEVATIONS AS REQUESTED ON PREVIOUS
 CHECKLIST.
 IN ADDITION BASE ON INFORMATION SUBMITTED THE FOLLOWING
 ITEMS NEED TO BE ADDRESSED:
 (1)FLORIDA PRODUCT APPROVAL FL 4307AND NOA
 03-0213.15 SUBMITTED DON'T CORRESPOND TO EACH OTHER.
 THESE ARE TWO DIFFERENT PRODUCT APPROVALS. PROVIDE
 COMPLETE INFORMATIONEITHERFOR THE FLORIDA PRODUCT
 APPROVAL OR THE DADE COUNTY PRODUCT APPROVAL. ARCHITECT
 APPROVED THE FLORIDA PRODUCT APPROVAL COVER PAGE , BUT
 THERE ARE NOT DRAWINGS SHOWING WHICH MODEL HE APPROVED.
 HOW HE KNOWS THE PRODUCT APPROVAL IS GOOD FOR THE
 CALCULATED DESIGN PRESSURES?
  
 (2) NEED THE NAME OF PERSON APPROVING THE PRODUCT
 APPROVAL.WRITING"APPROVED"ON THE PRODUCT
 APPROVAL IS NOT ENOUGH INFORMATIONBECAUSE IT DOESN'T
 IDENTIFYTHE PERSON OR COMPANY APPROVING THE PRODUCT
 APPROVAL. TYPICALLY THE STANDARD SHOP DRAWINGS REVIEW
 STAMP WITH THE LOGO OR NAME OF THE COMPANY IS USED AND
 IS ACCEPTABLE TO COMPLY WITH THIS SECTION.
  
 B) METAL ROOF AT NEW CUPOLA REQUESTED ON PREVIOUS
 CHECKLIST.
 NOTE: MAKE SURE PRODUCT APPROVAL MEETS THE DESIGN
 PRESSURES OF TABLE 1609.6.2.1(2) FBC 2004 FOR ZONES 2
 AND 3.
  
 C) WINDOW MULLIONS REQUESTED ON PREVIOUS CHECKLIST.
  
 D) SINGLE HUNG WINDOWS.
 BASED ON INFORMATION SUBMITTED THE FOLLOWING IS
 REQUIRED:
 (1) FLORIDA PRODUCT APPROVAL FL7938 AND NOA
 02-0719.05 DON'T CORRESPOND TO EACH OTHER.PROVIDE
 PRODUCT APPROVAL FOR EITHER ONE, BUT DON'T MISMATCH ONE
 WITH THE OTHER.
  
 (2) ARCHITECT'S PLANS CALL FOR WINDOWS WITH
 HURRICANE MISSILE IMPACT GLAZING. FLORIDA PRODUCT
 APPROVAL FL7938 IS NOT FOR IMPACT GLAZING AND THIS IS
 THE ONE THAT ARCHITECT APPROVED. WHY?
  
 E) EXTERIOR SWINGING DOORS:INFORMATION SUBMITTED
 REQUIRES THE FOLLOWING:
 (1) FLORIDA PRODUCT APPROVAL FL253 AND NOA
 05-0103.03 DON'T CORRESPOND TO EACH OTHER. THESE ARE
 TWO DIFFERENT PRODUCT APPROVALS. NEED TO SUBMIT
 COMPLETE INFORMATION FOR EITHER ONE.
  
 (2) FL253-R0DOESN'T HAVE ANY DRAWINGS AND IS FOR
 CODE VERSION 2001.NEED TO PROVIDE 2004 CODE VERSION.
 ARCHITECT TO MAKE SURE CORRECT CODE EDITION IS USED
 PRIOR TO APPROVAL.
  
 5- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY
 AMENDMENTS TO FBC 2004. MAKE SURE NAME OR ARCHITECT OR
 COMPANY NAME IS INCLUDEDTO VERIFYTHAT DESIGNER OF
 RECORD IS THE ONE APPROVING THE PRODUCT APPROVALS.
  
 6- PROVIDE COMPLETE SPECS FOR BBQ GRILL AS REQUESTED ON
 PREVIOUS CHECKLIST.
 NOTE:MAKE SURE BBQ GRILL IS DESIGNED FOR INSTALLATION
 IN PORCH AS SPECIFIED ON PLANS. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 7- ARCHITECT TO SPECIFY ROOF TILE FASTENING AS REQUIRED
 BY BY SEC. 106.1.1.2CITY AMENDMENTS TO FBC 2004. NEW
 DETAIL SUBMITTED ONLY IDENTIFIES RIDGE INSTALLATION,
 WHICH IS REQUIRED BY RAS 118.IT DOESN'T SPECIFY HOW
 ARE THE RESTOF TILES INSTALLED. IT'S GOING TO BE
 POLYPRO ADHESIVE OR NAILS OR SCREWS. IF USING NAILS OR
 SCREWS, THEN SPECIFY SIZE AND NUMBER. IF USING POLYPRO,
 THEN PROVIDE PRODUCT APPROVAL.
  
 8- SPECIFY ATTIC VENTILATION AT NEW CUPOLA AS REQUIRED
 BY SEC. R806 OF 2004 FLORIDA RESIDENTIAL CODE .EVEN
 THOUGH THE CUPOLA IS DECORATIVE, STILL VENTILATION IS
 REQUIRED. THERE ARE NOT EXCEPTIONS IN THE CODE.
  
 9- SPECIFY ALL LIVE AND DEAD LOADS, INCLUDING ATTIC
 LIVE LOADS AS REQUIRED BY TABLE R301.5 OF 2004 FLORIDA
 RESIDENTIAL CODE. ARCHITECT'S RESPONSE LETTER SAID "SEE
 REVISIONS TO SHEET S.3". THERE ARE NOT REVISIONS
 SHOWING THE LOADS ON SHEET S.3.
 IN ADDITION REVISE NOTE D4 ON SHEET S.1 TO INCLUDE ALL
 LOADS INCLUDING THE ATTIC LIVE LOAD.
  
 10- SOIL TEST REPORT PROVIDED REQUIRES THE FOLLOWING:
 A) ENGINEER'S ORIGINAL SIGNATURE AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTE AND SEC. 61G15-23.002 OF
 FLORIDA ADMINISTRATIVE CODE. REPORT SUBMITTED HAVE COPY
 OF THE SIGNATURE.
  
 B) REPORT NEEDS TO HAVE THE FIRM'S CERTIFICATE OF
 AUTHORIZATION NUMBER AS REQUIRED BY SEC. 61G15-23.002
 OF FLORIDA ADMINISTRATIVE CODE.
  
 11- COORDINATE FOOTING SIZE SHOWN ON DETAIL1/S.2 WITH
 FOOTING SCHEDULE TO MATCH.SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 12- COORDINATE LINTEL SCHEDULE WITH OPENING SIZE SHOWN
 ON PLANS. EG:CHECK LINTEL L3 IN DINING ROOM AREA.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 13- PROVIDE COMPLETE DETAIL/SPECS FOR SOFFIT
 CONSTRUCTION. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
 DETAIL4/S.3 DOESN'T IDENTIFY SOFFIT CONTRUCTION.IF
 USING STUCCO SEE ASTM C926 AND ASTM C1063 TO GET PROPER
 INFORMATION.
 ALSO, THERE ARE NOT SPECS FOR CEILING INSTALLATION AT
 MASTER BEDROOM AND ENTRY PORCH. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 14- SHEET A.1:
 A) KEY LEGEND AND FIRE RATING AND LIFE SAFETY NOTES
 DON'T MATCH. REVISE AS REQUIRED.
  
 B) EGRESS NOTE #2 CALLS FOR OPENING "MIN 22" WIDE OR
 24" HIGH" IS INCORRECT.IT CAN'T BE ONE OR THE OTHER.
 IT MUST MEET BOTH MINIMUM DIMENSIONS. SEE SEC. R310 OF
 2004 FLORIDA RESIDENTIAL CODE AND REVISE NOTE AS
 REQUIRED.
  
 C) CLARIFY NOTE #3. WHERE IS THIS INFORMATION TAKEN
 FROM?SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 15- ALL EXTERIOR ELEVATIONS,SECTION4/A.6, SECTIONS
 ON SHEET A.7AND A.8,AND SEC. 2 /S.3 CALL FOR 5/8"
 ROOF SHEATHING. SPECIFICATION PS-1 ON SHEET S.1
 CALLS FOR 3/4"ROOF SHEATHING. REVISE AS REQUIRED TO
 MATCH. SEC. 106.1.2CITY AMENDMENTS TO FBC 2004.
  
 16- SHEET S.2:
 A) NEW TYP. COLUMN CONNECTOR DETAIL: SIZE OF WEDGE
 ANCHOR SPECIFIED ON SECTION DOESN'T MATCH SIZE
 SPECIFIED ON STEEL PLATE PLAN. REVISE AS REQUIRED TO
 MATCH.
  
 B) SPECIFY COLUMNS AT ENTRY PORCH. THEY ARE SHOWN
 BIGGER THAN THE 8"COLUMN SPECIFIED FOR BREEZEWAY.
  
 17-SHEET S.3:
 A) SPECIFY CONNECTORS AT TOP OF WOOD COLUMNS AT
 CORNER AREAS SHOWING HOW ARE WOOD BEAMS COMING FROM 2
 DIFFERENT DIRECTIONSARE CONNECTED.SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 B) SPECIFY END CONNECTORSFOR WOOD BEAMS AT MASTER
 BEDROOM AND ENTRY PORCH SHOWING HOW ARE BEAMS SUPPORTED
 ON MASONRY WALL. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004
  
 C) CONNECTION SCHEDULE:
 (1) SIMPSON STRAP LTS18 IS NOT DESIGNED TO PROVIDE
 LATERAL SUPPORT. WHERE IS THE 200# TAKEN FROM? AND WHAT
 LATERAL LOAD (PERPENDICULAR OR PARALLEL) IS THIS NUMBER
 FOR?SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 (2) SPECIFY BOTH LATERAL LOADS FOR WHICHSIMPSON
 HETA20 IS DESIGNED FOR. SEE SIMPSON CATALOG.
  
 (3) WHERE IS UPLIFT LOAD FOR SIMPSON HETA20 TAKEN
 FROM?. IT DOESN'T MATCH UPLIFT LOAD TESTED AND
 PUBLISHED BY THE MANUFACTURER. SEE CURRENT CATALOG AND
 REVISE AS REQUIRED.
  
 (4) CONNECTOR SPECIFIED ON SECTION 2 DOESN'T MATCH
 CONNECTION SCHEDULE. REVISE AS REQUIRED.
  
 (5) SECTION 2 DOESN'T MATCH SECTION 4/A.7.THERE
 ARE TWO ADDITIONALTOP PLATES SPECIFIED ON DETAIL
 4/A.7. REVISE AS REQUIRED TO MATCH.
  
 (6) SIZE OF POST SPECIFIED ON DETAIL 2/S.3 DOESN'T
 MATCH SIZE SPECIFIED ON FOUNDATION PLAN. REVISE AS
 REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-26 Cont ID  
Sent By jgomez Date 2007-06-26 Time 15:07 Rev Time 0.00
Received By jgomez Date 2007-06-26 Time 12:20 Sent To PC
Notes
2007-06-26 15:23:18BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- PROVIDE COPY OF IMPACT FEES PAID RECEIPT.
  
 3- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) GARAGE DOORS THAT MATCH THOSESHOWN ON
 ARCHITECTURAL EXTERIOR ELEVATIONS.
  
 B) METAL ROOF AT NEW CUPOLA.
  
 C) CUPOLA LOUVERED SCREEN.
  
 D) WINDOW MULLIONS.
  
 E) SINGLE HUNG WINDOWS. NOA #02-0123.04 SUBMITTED IS
 FOR SMALL MISSILE IMPACT RESISTANT WINDOWS. NEED
 PRODUCT APPROVAL FORLARGE MISSILE IMPACT WINDOWS AT
 OPENINGS BELOW 30'-0".
  
 F) ALLSIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS.
  
 4- ARCHITECT NEEDS TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 5- PROVIDE COMPLETE SPECS FOR BBQ GRILLTO BE
 INSTALLED IN THE PORCH.SEC. 106.1.2 CITY AMENDMENTS
 TO FBC 2004.
  
 6- ARCHITECT TO SPECIFY ROOF TILE FASTENING AS REQUIRED
 BY SEC. 106.1.1.2 CITY AMENDMENTS TO FBC 2004. ***NOTE:
 DON'T SPECIFY PER PRODUCT APPROVAL.PRODUCT APPROVAL
 IS ONLY TO VERIFY COMPLIANCE WITH ARCHITECT'S DESIGN
 CRITERIA.
  
 7- CLARIFYIF LOUVERS AT NEW CUPOLA ARE DECORATIVE OR
 FUNCTIONAL. CUPOLA DETAIL SHOWS OPERABLE LOUVERS. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 8- SPECIFY ATTIC VENTILATION AT MAIN ROOF AND CUPOLA.
 SEC. R806 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 9- PROVIDE DRAINAGE PLAN. SEC. R401.3 OF 2004 FLORIDA
 RESIDENTIAL CODE.AND, SHOW HOW WATER WILL BE DIVERTED
 AWAY FROM NEIGHBOR'S PROPERTY.
  
 10- SPECIFY ALL LIVE AND DEAD LOADS, INCLUDING ATTIC
 LIVE LOADS AS REQUIRED BY TABLE R301.5 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 11- PROVIDE SOIL TEST REPORT.
  
 12- COORDINATE FOOTINGS ON FOUNDATION PLAN WITH FOOTING
 SCHEDULE. SIZES DON'T MATCH.
  
 13- COORDINATE LINTEL SCHEDULE WITH OPENING SIZES SHOWN
 ON PLANS.
  
 14- PROVIDE COLUMN SCHEDULE TO VERIFY TYPE OF COLUMNS.
 STRUCTURAL PLANS DON'T IDENTIFY THEM. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 15- PROVIDE COMPLETE DETAILS/SPECS/ CONNECTORS AT TOP
 AND BOTTOM OF WOOD COLUMNS. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 16- PROVIDE COMPLETE BEAM. SEC. 106.1.2 CITY AMENDMENTS
 TO FBC 2004.
  
 17- PROVIDE TRUSS ANCHOR SCHEDULE.
 ***NOTE: MAKE SURE PROPER CONNECTORS ARE SPECIFIED. EG:
 WOOD TO WOOD CONNECTORS, WOOD TO MASONRY CONENCTORS OR
 WOOD TO EXISITNG MASONRY WALL CONNECTORS.
 AND, SEE CURRENT CATALOG FOR PROPER FASTENER SIZE AND
 NUMBER.
  
 18- SPECIFY ATTICACCESS SIZE AND LOCATION AT NEW
 FAMILY ROOM, GARAGE AND MASTER BEDROOM. SEC. R807 OF
 2004 FLORIDA RESIDENTIAL CODE.
  
 19- SPECIFY FIREBLOCKING TYPE AND SIZE IN WALL SECTIONS
 AS REQUIRED BY SEC. R602.1.2 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 20- PROVIDE COMPLETE DETAIL/ SPECS FORSOFFIT
 CONSTRUCTION. SEC. 106.1.2 CITY AMENDMENT TO FBC 2004.
  
 21- SPECIFY ROOF PITCH TO VERIFY COMPLIANCE WITH SEC.
 R905 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 22- ROOF FRAMING PLAN DOESN'T SHOW LOCATION OF CUPOLA.
 PROVIDE COMPLETE INFORMATION. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 23- OWES $22.52 FOR RADON FEES.
  
 24- SHEET A.0:
 * THIS IS LEVEL OF ALTERATION 3, NOT 2. REVISE.
 ** THIS IS RESIDENTIAL R3, NOT R. REVISE.
 *** THIS IS FLOOD ZONE C, NOT '*'. REVISE
  
 25- SHEET S.1:
 * REVISE NOTE M-4. SEE SEC. R606.4 OF 2004 FLORIDA
 RESIDENTIAL CODE.
 ** COORDINATE NOTE PS-1 WITH ARCHITECTURAL DRAWINGS.
  
 NOTE:
 PLEASE RETURN REVIEWED SET AFTER CORRECTIONS ARE DONE
 TO EXPEDITE THE REVIEW PROCESS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 6 Status N Date 2008-10-02 Cont ID  
Sent By btrobaug Date 2008-10-02 Time 12:26 Rev Time 0.00
Received By btrobaug Date 2008-10-02 Time 12:20 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2008-06-23 Cont ID  
Sent By btrobaug Date 2008-06-23 Time 09:53 Rev Time 0.00
Received By btrobaug Date 2008-06-23 Time 09:17 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2008-06-12 Cont ID  
Sent By btrobaug Date 2008-06-12 Time 12:37 Rev Time 0.00
Received By btrobaug Date 2008-06-12 Time 11:43 Sent To M
Notes
2008-06-12 12:03:15 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE
 CYCLES:
  
 THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004
 RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC CHAPTER 1
 AS AMENDED AND FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE RISER INDICATES A METER/MAIN, THE FLOOR PLAN
 SHOWS A METER ONLY. CORRELATE TO SHOW ACTUAL
 INSTALLATION.106.1.1 FBC AS AMENDED.
  
 2} GEC FROM PANEL "H" MUST NOT BE INSTALLED AS IT
 PARALLELS THE EQUIPMENT GROUND IN VIOLATION OF 250.6.
  
 3} THERE HAVE BEEN NO ELECTRICALREVISIONS SINCE THE
 PERMIT SET WAS REVIEWED. THE ENTIRE HOUSE APPEARS TO
 HAVE BEEN REWIRED.. NO CLOUDS ARE ON THE PLAN
 INDICATING REVISIONS 2,3 AND 4, THEREFORE WHAT IS PART
 OF THIS PERMIT CANNOT BE KNOWN OR REVIEWED. CLOUD THE
 REVISIONS OR INDICATE THE CHANGES THAT APPLY TO THIS
 PERMIT.
  
 4} ADJUST THE VALUE TO REFLECT THE ADDED LABOR AND
 MATERIAL AT THE PERMIT CLERK?S DESK, AND PAY THE
 DIFFERENCE IN FEES PRIOR TO RESUBMITTING.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-10-11 Cont ID  
Sent By btrobaug Date 2007-10-11 Time 12:35 Rev Time 0.00
Received By btrobaug Date 2007-10-11 Time 12:32 Sent To B
Notes
2007-10-11 12:34:03 
  
 RESUBMITTED REVIEWD SET FROM 8/9/07 REVIEW, STAMPED
 M.E.P'S SENT TO JULIO./WRT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-08-09 Cont ID  
Sent By btrobaug Date 2007-08-09 Time 16:57 Rev Time 0.00
Received By btrobaug Date 2007-08-09 Time 16:22 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-05-25 Cont ID  
Sent By btrobaug Date 2007-05-25 Time 15:31 Rev Time 0.75
Received By btrobaug Date 2007-05-25 Time 09:16 Sent To M
Notes
2007-05-25 15:30:55 
  
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW
  
 1} THE RISER ONLY INDICATES ONE 200 AMP PANEL WITH 42
 CIRCUITS, THE SCHEDULE LISTS 49 CIRCUITS.
  
 2} 408.4 CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION
 EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY
 IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE
 SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE
 DISTINGUISHED FROM ALL OTHERS.
  
 3}R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED
 IN NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT. PLEASE
 LOCATE ON THE PLAN.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2008-09-23 Cont ID  
Sent By adarroug Date 2008-09-23 Time 10:57 Rev Time 0.00
Received By adarroug Date 2008-09-23 Time 10:57 Sent To Z
Notes
2008-09-23 10:58:03TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2008-07-31 Cont ID  
Sent By adarroug Date 2008-07-31 Time 10:46 Rev Time 0.00
Received By adarroug Date 2008-07-31 Time 10:46 Sent To B
Notes
2008-07-31 10:47:20TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2008-07-24 Cont ID  
Sent By adarroug Date 2008-07-24 Time 11:08 Rev Time 0.00
Received By adarroug Date 2008-07-24 Time 11:08 Sent To P
Notes
2008-07-24 11:08:24TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2008-07-23 Cont ID  
Sent By adarroug Date 2008-07-23 Time 11:50 Rev Time 0.00
Received By adarroug Date 2008-07-23 Time 11:50 Sent To B
Notes
2008-07-23 11:51:08TO "JGOMEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2008-07-21 Cont ID  
Sent By adarroug Date 2008-07-21 Time 11:48 Rev Time 0.00
Received By adarroug Date 2008-07-21 Time 11:48 Sent To P
Notes
2008-07-21 11:50:33TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-06-26 Cont ID  
Sent By shill Date 2008-06-26 Time 15:32 Rev Time 0.00
Received By shill Date 2008-06-26 Time 15:32 Sent To M
Notes
2008-06-26 15:33:15TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-06-19 Cont ID  
Sent By adarroug Date 2008-06-19 Time 11:21 Rev Time 0.00
Received By adarroug Date 2008-06-19 Time 11:21 Sent To E
Notes
2008-06-19 11:22:12TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-06-06 Cont ID  
Sent By adarroug Date 2008-06-06 Time 15:32 Rev Time 0.00
Received By adarroug Date 2008-06-06 Time 15:32 Sent To  
Notes
2008-06-06 15:33:04TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-10-31 Cont ID  
Sent By adarroug Date 2007-10-31 Time 16:13 Rev Time 0.00
Received By adarroug Date 2007-10-31 Time 16:13 Sent To B
Notes
2007-10-31 16:13:31TO "JGOMEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-10-05 Cont ID  
Sent By adarroug Date 2007-10-05 Time 09:59 Rev Time 0.00
Received By adarroug Date 2007-10-05 Time 09:59 Sent To Z
Notes
2007-10-05 10:00:24TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-08-03 Cont ID  
Sent By adarroug Date 2007-08-03 Time 09:03 Rev Time 0.00
Received By adarroug Date 2007-08-03 Time 09:03 Sent To Z
Notes
2007-08-03 09:03:40TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-26 Cont ID  
Sent By jgomez Date 2007-06-26 Time 15:23 Rev Time 0.00
Received By jgomez Date 2007-05-17 Time 10:51 Sent To  
Notes
2007-05-17 10:51:57TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2008-06-27 Cont ID  
Sent By tgordon Date 2008-06-27 Time 09:00 Rev Time 1.00
Received By tgordon Date 2008-06-27 Time 09:00 Sent To  
Notes
2008-06-27 09:01:59REVISION TO MECH. PLAN M.1, AND COOLING LOAD CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2008-06-23 Cont ID  
Sent By tgordon Date 2008-06-23 Time 12:02 Rev Time 1.00
Received By tgordon Date 2008-06-23 Time 12:02 Sent To  
Notes
2008-06-23 12:08:35PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 REVISION TO MECHANICAL PLAN M.1.
 *** DENIED ***
  
 1) NOTED IN LAST REVIEW 6-13-08 NOTE #1. ENERGY
 CALCULATION ON FILE ARE CALLING FOR 14 SEER (MIS-TYPED
 13 SEER IN LAST REVIEW) A/C SYSTEMS, A/C SYSTEM #3 ON
 REVISED MECHANICAL PLAN IS A 13 SEER. PLEASE CORRECT
 (MAY NEED TO REVISE ENERGY CALCULATIONS) PER 2004 FBC
 13-103.3.
  
 2) NOTED IN LAST REVIEW 6-13-08 NOTE #2. A/C SYSTEMS 1
 AND 2 MODEL NUMBERS ARE NOT CORRECT (SEE ATTACHED ARI
 CERTIFICATES). PLEASE SUBMIT ARI CERTIFICATES FOR A/C
 SYSTEMS ANDCORRECT EQUIPMENT SCHEDULE, PER 2004 FBC
 106.3.5.
  
 2A) IF THE ATTACHED ARI CERTIFICATE FOR SYSTEM 2 IS THE
 SYSTEM BEING INSTALLED PLEASE CORRECT THE SEER AND
 TOTAL COOLING BTU'S IN THE EQUIPMENT SCHEDULE ON
 MECHANICAL PLAN.
  
 3) NOTED IN LAST REVIEW 6-13-08 NOTE #3. THE COOLING
 LOAD CALCULATIONS ON FILE (SEE ATTACHED COPY) ARE
 CALLING FOR 66,423 TOTAL COOLING BTU'S, THE REVISED
 MECHANICAL PLAN EQUIPMENT SCHEDULE TOTALS 89,800 TOTAL
 COOLING BTU'S, THE PLANS CAN ONLY CALL FOR 15% MORE
 TOTAL COOLING BTU'S THAN THE COOLING LOAD CALCULATIONS
 PER 2004 FBC 13-607.1.ABC.1.1. PLEASE CORRECT PLANS OR
 REVISE COOLING LOAD CALCULATIONS WITH ZONES FOR EACH
 SYSTEM.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2008-06-13 Cont ID  
Sent By tgordon Date 2008-06-13 Time 08:08 Rev Time 0.45
Received By tgordon Date 2008-06-13 Time 08:08 Sent To  
Notes
2008-06-13 08:28:07PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 REVISION TO MECHANICAL PLAN M.1.
 *** DENIED ***
  
 1) ENERGY CALCULATION ON FILE ARE CALLING FOR 14 SEER
 A/C SYSTEMS, A/C SYSTEM #3 ON REVISED MECHANICAL PLAN
 IS A 13 SEER (SEE ATTACHED ARI CERTIFICATE). PLEASE
 CORRECT PER 2004 FBC 13-103.3.
  
 2) AIR HANDLERS #1 AND #2 MODEL NUMBERS ARE NOT
 COMPLETE (SEE RED LINE ON PLAN) THEY MUST INCLUDE THE
 COIL AS MULTIPLE COILS MAY BE INSTALLED IN THE AIR
 HANDLER. PLEASE CORRECT PER 2004 FBC 106.3.5.
  
 3) THE COOLING LOAD CALCULATIONS ON FILE ARE CALLING
 FOR 66,423 TOTAL COOLING BTU'S, THE REVISED MECHANICAL
 PLAN EQUIPMENT SCHEDULE TOTALS 89,600 TOTAL COOLING
 BTU'S, THE PLANS CAN ONLY CALL FOR 15% MORE TOTAL
 COOLING BTU'S THAN THE COOLING LOAD CALCULATIONS PER
 2004 FBC 13-607.1.ABC.1.1. PLEASE CORRECT PLANS OR
 REVISE COOLING LOAD CALCULATIONS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-08-14 Cont ID  
Sent By tgordon Date 2007-08-14 Time 08:29 Rev Time 0.25
Received By tgordon Date 2007-08-14 Time 08:29 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-05-24 Cont ID  
Sent By tgordon Date 2007-05-24 Time 09:25 Rev Time 0.30
Received By tgordon Date 2007-05-24 Time 09:25 Sent To E
Notes
2007-05-24 09:36:04*** DENIED ***
 1) ARCHITECTURE FIRM MESAARCHITECT BUSINESS LICENSE
 EXPIRED 2-28-07, PLEASE CORRECT.
  
 2) SHOW ON MECHANICAL PLANS THE CLOTHES DRYER VENT AND
 WERE IT IS TERMINATING AT. BE ADVISED THE CLOTHES DRYER
 VENT TERMINATION MAY NOT BE NEAR THE A/C CONDENSER
 UNITS, SEE 2004 FBC/M 501.2 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-07-28 Cont ID  
Sent By mperson Date 2008-07-28 Time 15:48 Rev Time 0.00
Received By mperson Date 2008-07-28 Time 15:48 Sent To PC
Notes
2008-07-28 15:53:14REVISION #7 SHEET P.1: "OK" INDICATE VENT THRU SIDE
 WALL ON FIRST FLOOR PLUMBING PLAN AND SANITARY RISER
 DIAGRAM ALSO INDICATED WASHING MACHINE CLEANOUT AS
 BEING 3 INCH ON FIRST FLOOR PLUMBING PLAN.

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-07-21 Cont ID  
Sent By mperson Date 2008-07-21 Time 14:40 Rev Time 0.00
Received By mperson Date 2008-07-21 Time 14:40 Sent To PC
Notes
2008-07-21 15:22:03PLUMBING PLAN REVIEW:
 REVISION DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE.
  
 1. SHEET P.1 IS INDICATING THE WRONG REVISION NUMBER
 3. THAT REVISION NUMBER IS DATED 10/30/07 WHICH IS
 BEFORE PLANS WERE PERMITTED. I THINK THE CORRECT
 REVISION NUMBER SHOULD BE 7. PLEASE CLARIFY, CORRECT,
 AND CORRELATE THIS REVISION. PER THE FOLLOWING "ALL
 CHANGES TO THE PLAN ARE TO BE CLOUDED WITH REVISION
 NUMBERS/DATES PER FBC-2004 CHAPTER 1, SECTION 106.1.3
 THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM.
 NOTE: A TRANSMITTAL LETTER IS HELPFUL."
  
 2. SHEET P.1 PLUMBING FLOOR PLAN HAS THE INCORRECT
 SIZE OF THE CLEANOUT FOR THE WASHING MACHINE INDICATED
 AS BEING 2 INCH. THE CORRECT SIZE OF THIS CLEANOUT IS 3
 INCH. PER FBC- PLUMBING SECTION 708.7 MINIMUM SIZE.
  
 3. SHEET P.1 SANITARY RISER DIAGRAM: THE TWO
 LAVATORIES ARE NOT BEING IDENTIFIED IN MASTER BATH #113
 ON THE RISER DIAGRAM. PER FBC- PLUMBING SECTION 401.1
 AND 701.1 SCOPE.
  
 4. SHEET P.1 SANITARY RISER DIAGRAM: THE REVISION WITH
 THE VENT THRU WALL INSTEAD OF THRU THE ROOF NEEDS
 CLARIFICATION. A PLUMBING INSPECTION DATED 6/25/08
 INDICATED REVISION REQUIRED, THAT AN AIR ADMITTANCE
 VALVE WAS INSTALLED ON THE OUTSIDE BLOCK WALL INSTEAD
 OF A VENT THRU ROOF. THE SUBMITTED PLUMBING REVISION
 DOES NOT INDICATE AN AIR ADMITTANCE VALVE. THE REVISION
 INDICATES A VENT THRU WALL WHICH NEEDS TO HAVE THE
 FOLLOWING INDICATED ON THE PLANS BEFORE IT IS
 COMPLIANT. PER FBC- PLUMBING SECTION 904.6 EXTENSION
 THROUGH THE WALL. VENT TERMINALS EXTENDING THROUGH THE
 WALL SHALL TERMINATE A MINIMUM OF 10 FEET (3048 MM)
 FROM THE LOT LINE AND 10 FEET (3048 MM) ABOVE AVERAGE
 GROUND LEVEL. VENT TERMINALS SHALL NOT TERMINATE UNDER
 THE OVERHANG OF A STRUCTURE WITH SOFFIT VENTS. SIDE
 WALL VENT TERMINALS SHALL BE PROTECTED TO PREVENT BIRDS
 OR RODENTS FROM ENTERING OR BLOCKING THE VENT OPENING.
 NOTE: IF AN AIR ADMITTANCE VALVE IS BEING INSTALLED
 PLEASE INDICATE THAT THIS VALVE WILL BE PROTECTED FROM
 HARMFULL ULTRA-VIOLET (UV) SUN RAYS PER MANUFACTURER'S
 RECOMMENDATIONS.
 ALSO THE VENT CAN NOT BE INSTALLED WITHOUT A VERICAL
 RISE ABOVE THE FLOOD LEVEL RIM OF THE LAVATORY PER FBC-
 PLUMBING SECTION 905.4 VERTICAL RISE OF VENT. EVERY DRY
 VENT SHALL RISE VERTICALLY TO A MINIMUM OF 6 INCHES
 (152 MM) ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST TRAP
 OR TRAPPED FIXTURE BEING VENTED. THE SUBMITTED REVISION
 ON THE PLANS DO NOT INDICATE THIS REQUIREMENT. THE
 SUBMITTED REVISION INDICATES A HORIZONTAL DRY VENT WITH
 NO VERTICAL RISE AS REQUIRED.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-08-13 Cont ID  
Sent By mperson Date 2007-08-13 Time 16:46 Rev Time 0.33
Received By mperson Date 2007-08-13 Time 16:46 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-06-08 Cont ID  
Sent By mperson Date 2007-06-08 Time 14:27 Rev Time 0.45
Received By mperson Date 2007-06-08 Time 14:27 Sent To B
Notes
2007-06-08 15:24:54DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET P.1 SANITARY ISOMETRIC RISER DIAGRAM: THE
 FOLLOWING IS REQUIRED AND NEEDS TO BE INDICATED ON THE
 DRAWINGS FOR THE WASHING MACHINE PER FBC-2004
 PLUMBING.
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 NOTE: THE WASHING MACHINE BRANCH AND STACK DRAIN ARE
 SIZED WRONG ON THE ISOMETRIC. PLEASE CORRECT ON THE
 RESUBMITTAL.
  
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY
 TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING. PLEASE INDICATE THE STANDPIPE ON THE
 RESUBMITTAL.
  
 (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM).
 NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE THREE
 INCH (3"). PLEASE INDICATE THIS ON THE RESUBMITTAL.
  
 (D) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS.
 NOTE: CLEANOUT FOR THE WASHING MACHINE TO BE LOCATED AT
 FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.). PLEASE
 INDICATE THIS ON THE RESUBMITTAL.
  
 2. SHEET P.1 SANITARY ISOMETRIC RISER DIAGRAM: THE LAV
 IN ROOM 114 IS DRAWN WRONG AND DOES NOT REFLECT THE
 PLUMBING FLOOR PLAN. PLEASE CORRECT ON THE
 RESUBMITTAL.
  
 3. SHEET P.1 SANITARY ISOMETRIC RISER DIAGRAM: THE
 ISOMETRIC DOES NOT REFLECT THE PLUMBING FLOOR PLAN FROM
 THE BUILDING SEWER TO THE MASTER BATH AND ALSO TO THE
 LAVS IN MASTER BATH ROOM #113. PLEASE CORRECT ON THE
 RESUBMITTAL.
  
 4. SHEET P.1 SANITARY ISOMETRIC RISER DIAGRAM AND
 PLUMBING FLOOR PLAN: MASTER BATH ROOM #113 A VENT IS
 REQUIRED FOR THE SHOWER PER TABLE 906.1 A 2" TRAP CAN
 ONLY BE 6' FROM VENT. PLEASE CORRECT ON THE
 RESUBMITTAL.
  
 5. SHEET P.1 SANITARY ISOMETRIC RISER DIAGRAM AND
 PLUMBING FLOOR PLAN: PLEASE SEE RED LINE CORRECTIONS TO
 THE TWO-WAY CLEANOUTS IN THREE PLACES.
  
 6. SHEET P.1 PLUMBING NOTE NUMBER SEVEN (7): PLEASE
 DELETE THE FOLLOWING "FURNISH AND INSTALL APPROVED
 SHOCK ABSORBERS AT EACH PLUMBING FIXTURE GROUP" AND
 PLEASE ADD THE FOLLOWING "PER FBC-2004 PLUMBING,
 SECTION 604.9 A WATER-HAMMER ARRESTOR SHALL BE
 INSTALLED WHERE QUICK-CLOSING VALVES ARE UTILZED AND
 SHALL BE INSTALLED IN ACORDANCE WITH THE MANUFACTURER'S
 SPECIFICATIONS."
  
 7. SHEET P.1 PLUMBING FLOOR PLAN IS INDICATING A GAS
 WATER HEATER AND A GAS STUB W/ SHUTOFF IN THE PROPOSED
 COVERED PATIO AREA. A SEPERATE GAS PERMIT IS REQUIRED
 FOR THIS WORK. PLEASE PROVIDE THE FOLLOWING INFORMATION
 FOR THE GAS PERMIT.
  
 A} SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
  
 B} SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
  
 C} TYPE OF GAS, (LP OR NATURAL).
  
 D} BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU
 402.4(33).
  
 E} SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2004 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES A.3.1(4).
  
 F} INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
  
 G} SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2004 FUEL GAS CODE SEC 402.2.
  
 H} CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
  
 I} CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND APPURTENANCES
 PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 4 Status P Date 2008-09-30 Cont ID  
Sent By mcruz Date 2008-09-30 Time 11:43 Rev Time 0.00
Received By mcruz Date 2008-09-30 Time 11:40 Sent To B
Notes
2008-09-30 11:43:27PURSUANT TO THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR),
 SECTION 94-304(D)(2)(D): IF A PATIO
 OR PAVED AREA IS PROVIDED ADJACENT
 TO OR SURROUNDING A POOL, IT SHALL BE
 DESIGNED TO DRAIN AWAY FROM THE
 POOL, BUT NOT ONTO ADJACENT PROPERTIES.

Review Stop Z ZONING
Rev No 3 Status P Date 2007-10-10 Cont ID  
Sent By choops Date 2007-10-10 Time 13:36 Rev Time 0.00
Received By choops Date 2007-10-10 Time 13:33 Sent To E
Notes
2007-10-10 13:36:40***APPROVED - RESUB #2***
  
 PROVISO:AS THE VALUE OF THE PROPOSED WORK EXCEEDS 50%
 OF THE VALUE OF THE EXISTING STRUCTURE, PURSUANT TO
 SECTION 94-441(C)(2) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDRS), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH SECTION 94-442 OF THE ZLDRS.
  
 FOR SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHADE,
 FLOWERING OR FRUIT TREE SHALL BE PLANTED FOR EACH 1,200
 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. FOR
 SINGLE-FAMILY DWELLING UNITS, AT LEAST ONE SHRUB SHALL
 BE PLANTED FOR EACH 500 SQUARE FEET OF OPEN SPACE OR
 PORTION THEREOF.
  
  
  
 SENT TO "E" - BT

Review Stop Z ZONING
Rev No 2 Status F Date 2007-08-03 Cont ID  
Sent By choops Date 2007-08-03 Time 18:14 Rev Time 0.00
Received By choops Date 2007-08-03 Time 18:14 Sent To E
Notes
2007-08-03 18:15:14***FAILED***
  
  
 1)ORIGINAL PLAT REQUIRES A RESIDENTIAL BUILDING LINE
 OF 60' FROM THE CENTERLINE OF THE ROAD (SEE ATTACHED
 PLAT MAP).BUILDING MUST BE SETBACK 60' FROM
 CENTERLINE OF ROAD.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-05-17 Cont ID  
Sent By choops Date 2007-05-17 Time 16:27 Rev Time 0.00
Received By choops Date 2007-05-17 Time 16:27 Sent To E
Notes
2007-05-17 16:33:39***FAILED***
  
  
 1)MUST OBTAIN A SEPERATE DRIVEWAY PERMIT.
  
 2)PLEASE PROVIDE ELEVATIONS FROM GRADE TO MIDPOINT
 OF ROOF'S PITCH.ALSO PROVIDE ELEVATION FROM GRADE TO
 COPULA ROOF'S MIDPOINT.
  
 3)PROVIDE ROOF OVERHANG DIMENSIONS (MAY ENCROACH
 INTO A REQUIRED SETBACK A MAXIMUM OF 3')
  
 4)INDICATE ON BOTH SURVEYS THE SCOPE OF WORK,
 DIMENSIONS OF WORK, AND SETBACK DIMENSIONS FORM
 PROPERTY LINES TO PROPOSED WORK.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720