| Plan Review Stops For Permit 07050608 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-08-04 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-08-04 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-08-04 |
Time |
11:06 |
Sent To |
PC |
|
| Notes |
| 2007-08-04 11:12:59 | | | | | | | PASSED | | | | | | NOTE: | | | | | | REQUIRES MECHANICAL REVIEW COMMENTS TO BE ADDRESSED | | | BEFORE FINAL PLAN STAMPING. PLEASE NOTE THAT THEIR ARE | | | FEES DUE OF $ 6.50 FOR THE STATE RADON FEE ALSO PER | | | 713.13(2) F.S. IF THE IMPROVEMENT DESCRIBED IN THE NOC | | | HAS NOT COMMENCED WITHIN 90 DAYS OF RECORDING, THE | | | NOTICE IS VOID THEREFORE THE NOC WILL NEED TO BE | | | RERECORDED. | | | | | | OLD DRAWINGS AND EXTRA PRODUCT APPROVALS CAN BE REMOVED | | | FROM SUBMITTAL BUT PLEASE DO NOT REMOVE PAGE WITH | | | IMPACT FEE STAMP AS IT IS REQUIRED TO BE PART OF THE | | | FILE SET. | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-30 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-06-30 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-06-30 |
Time |
10:30 |
Sent To |
PC |
|
| Notes |
| 2007-06-30 11:15:52 | | | | | | | DENIED | | | | | | 1)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH | | | COUNTY. THE ACTUAL PERMIT | | | SETS OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. THE STAMP IS | | | REQUIRED ALTHOUGH FEES MAY NOT BE | | | PLEASE CALL (561) 233-5025 FOR MORE | | | INFORMATION. | | | | | | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON | | | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER | | | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE | | | ADDED TO THE PERMIT APPLICATION FEES. TOTAL AMOUNT DUE | | | $ 6.50 | | | | | | 3)PLANS AND SPECIFICATIONS SHALL COMPLY WITH THE 2004 | | | FL BLDG CODE WITH 2006 AMENDMENTS | | | | | | 4)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE | | | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS | | | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN | | | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 | | | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C | | | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND | | | PRESSURES ACCORDINGLY | | | | | | 5)PROVIDE EXISTING AND NEW AREA SQUARE FOOTAGE ON THE | | | DRAWINGS | | | | | | 6)PROVIDE EXISTING FLOOR PLAN WITH DETAILS ON ANY | | | DEMOLITION OR REWORKING OF LAYOUT | | | | | | 7)PROVIDE SITE PLAN 2 COPIES OF A RECENT SURVEY | | | SHOWING THE PROPOSED BUILDING/ADDITION WITH ALL SIDE | | | AND REAR SETBACKS | | | | | | 8)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS | | | REQUIRED PER R807.1 FBC RES. | | | | | | 9)SUBMIT ENGINEERED TRUSS DRAWINGS FOR THE FLOOR AND | | | ROOF TRUSSES THAT | | | COMPLY WITH R802.10.1 FBC WITH PERMIT | | | APPLICATION OR BEFORE INSTALLATION THAT | | | HAVE BEEN REVIEWED AND APPROVED BY THE | | | DESIGNER OF RECORD | | | | | | 10)SUBMIT ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND | | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | | TO SUBMITTAL | | | | | | 11)PROVIDE ATTACHMENT METHOD FOR FLOOR TRUSSES TO NEW | | | GIRDER TRUSS | | | | | | 12)CLARIFY ATTACHMENT OF NEW FRAMED WALLS TO EXISTING | | | TIE BEAM IS THE SIMPSON HTT22 ON EVERY STUD OR JUST THE | | | CORNERS, IF THE LATTER WHAT CONNECTORS ARE TYING THE | | | WALLS TO TIE BEAM | | | | | | 13)DRAWING STATES THEIR ARE 2 CASEMENT WINDOWS 36 X | | | 72 BUT PRODUCT APPROVAL DOES NOT ALLOW FOR THAT SIZE. | | | MAX HEIGHT FOR 36" WIDTH IS 63" ALSO NOTE THE GLASS | | | TYPE AS THE "A" TYPE WILL NOT MEET THE DESIGN PRESSURES | | | REQUIRED. IF 2 SEPARATE WINDOWS ARE USED A PRODUCT | | | APPROVAL FOR MULLIONS IS REQUIRED BUT CASEMENT PRODUCT | | | APPROVAL HAS A "XX" CONFIGURATION WITH BUILT IN MEETING | | | RAIL | | | | | | 14)THE PRODUCT APPROVAL FOR ROOF TILES DOES NOT HAVE | | | STATE APPROVAL THE STATUS IS (APPLIED FOR) AND THE | | | COMPLIANCE REPORT WILL BE THE MIAMI-DADE NOA NOT THE | | | COMPLETE INSTALLATION GUIDE THAT WAS SUBMITTED. PLEASE | | | REMOVE THIS FROM PACKAGE AND SUBMIT THE MIAMI-DADE NOA | | | FOR THE TYPE OF ROOF TILE THAT WILL BE USED AND A LOCAL | | | PRODUCT APPROVAL WILL BE GRANTED BASED ON THAT NOA. | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-14 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-14 |
Time |
06:33 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-25 |
Time |
08:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-25 |
Time |
06:53 |
Sent To |
M |
|
| Notes |
| 2007-07-25 07:43:22 | | | | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} PROVIDE LOAD CALCULATIONS PER ARTICLE 220 PART III, | | | STANDARD OR PART IV OPTIONAL, INDICATE METHOD USED. | | | THIS COMMENT WAS INTENDED TO GET A LOAD CALCULATION FOR | | | THE ENTIRE SERVICE, NOT FOR INDIVIDUAL PANELS, WHICH | | | MAY OR MAY NOT BE ABLE TO BE LOADED TO THEIR MAXIMUM | | | OCP, DEPENDING ON HOW THE LOAD IS BALANCED. | | | | | | 2} THE EXISTING ELECTRICAL PANEL NOTES ON SHEET E-1, | | | INCORRECTLY INDICATE THE ELECTRICAL PLAN AND LEGEND ON | | | SHEET A-3. | | | | | | 3} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), INCLUDE IN THE SCHEDULE THIS WAS NOT | | | ON THE SCHEDULE IN THE RESUBMITTAL.. | | | | | | 4} THE DESIGNER WILL VERIFY THAT THE AIR CONDITIONING | | | LOAD WILL OR WILL NOT INCREASE AS THERE IS A MECHANICAL | | | PERMIT APPLICATION FOR THIS PROJECT. ADD THE | | | APPROPRIATE LOADS TO THE SERVICE CALCULATIONS AND | | | LOCATE THE UNITS ON THE PLAN.SEE M1305.1.3.1 RES FBC, | | | 210.63, 210.70 NEC. | | | | | | 5} THE STACK WASHER AND DRYER SHOWN IN THE ADDITION, | | | ARE NOT ON THE PANEL SCHEDULE. THERE IS NO WASHER AND | | | DRYER ON THE PANEL SCHEDULE. | | | | | | 6} CIRCUIT #18, PANEL A, 30 AMP OCP,#12 WIRE,IS A | | | VIOLATION OF 310.16. | | | | | | 7} THE A/C LOAD IS UNCLEAR, CLARIFY "AC#1 & #2 COMP", | | | CIRCUITS 9,11,13,15. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-05-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-31 |
Time |
12:32 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-05-31 |
Time |
12:01 |
Sent To |
P |
|
| Notes |
| 2007-05-31 12:32:29 | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} PROVIDE A LOAD CALCULATION PER 220.31, INCLUDE ADDED | | | LOADS. REQUIRED BY 215.5NEC | | | | | | 2} PROVIDE A PANEL SCHEDULE PER 408.4. PLEASE SEE NEW | | | VERBAGE FOR 2005 NEC: "THE IDENTIFICATION SHALL INCLUDE | | | SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE | | | DISTINGUISHED FROM ALL OTHERS." | | | | | | 3} BATH CIRCUIT REQUIRED TO HAVE A 20 AMP RECEPTACLE | | | PER 210.11(C) (3), INCLUDE IN THE SCHEDULE. | | | | | | 4} R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED | | | IN NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT. NOTE # 14 | | | INDICATES "BEDROOM ADDITIONS", WHICH IS CORRECT. BUT | | | NOTE FOR FUTURE PROJECTS THE TEXT IN THE RESIDENTIAL | | | CODE INDICATES ANYTIME A PERMIT IS PULLED FOR ANY | | | INTERIOR WORK, THE EXISTING BEDROOMS MUST COMPLY. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-08 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-08 |
Time |
18:08 |
Sent To |
E |
|
| Notes |
| 2007-08-08 18:08:51 | TO BT'S DESK/INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-18 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-18 |
Time |
14:41 |
Sent To |
Z |
|
| Notes |
| 2007-07-18 14:41:24 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-23 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-23 |
Time |
13:27 |
Sent To |
E |
|
| Notes |
| 2007-05-23 13:28:16 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-17 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2007-05-17 14:48:50 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-14 |
Time |
11:06 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-08-14 |
Time |
11:06 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-25 |
Time |
09:12 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-07-25 |
Time |
09:12 |
Sent To |
P |
|
| Notes |
| 2007-07-25 09:27:01 | *** DENIED *** | | | 1) BUILDING PLANS PAGE A-1 SHOWS THE NEW ADDITION IS | | | 638 FEET UNDER AIR, THEREFOR THE ENERGY CALCULATIONS | | | CAN NOT BE DONE ON FORM 600C-04R, SEE 2004 FBC | | | 13-600.3.C PLEASE CORRECT. | | | | | | 2) BUILDING PLANS PAGES A-1 AND D-1 ARE SHOWING THE | | | WRONG R VALUE FOR THE ATTIC AND WALL INSULATION, SEE | | | ENERGY CALCULATIONS PLEASE CORRECT. | | | | | | 3) PLEASE SHOW THE BATHROOM EXHAUST FANS AND THE | | | CLOTHES DRYER VENT ON THE MECHANICAL PLANS ALSO. | | | | | | 4) PLEASE SHOW THE CORRECT JOB ADDRESS ON THE | | | MECHANICAL PLANS, SEE 2004 FBC CITY WPB AMEND. | | | 106.1.3. | | | | | | 5) ALL INFORMATION, DRAWINGS, (MECHANICAL PLANS) | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | PRINTED NAME AND SIGNATURE OF THE PERSON RESPONSIBLE | | | FOR THE DESIGN. PER FBC 104.2.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-24 |
Time |
08:40 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-05-24 |
Time |
08:40 |
Sent To |
E |
|
| Notes |
| 2007-05-24 08:44:17 | *** DENIED *** | | | 1) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC | | | 13-101.2.2. | | | | | | 2) THE JOB ADDRESS NEEDS TO BE ON EACH PAGE ON THE | | | PLANS, SEE 2004 FBC, CITY WPB AMEND. 106.1.3 AND FAC | | | 61G1-16.004(3). | | | | | | 3) MECHANICAL PERMIT #07050612HAS BEEN APPLIED FOR | | | BUT NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. | | | PLEASE SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC | | | CITY OF WPB AMEND. 106.3.5.4 (10). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-15 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-15 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-15 |
Time |
10:46 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-08-02 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-08-02 |
Time |
13:54 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-09 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-09 |
Time |
11:09 |
Sent To |
B |
|
| Notes |
| 2007-06-09 11:32:13 | DENIED; | | | 1. CLEAN OUT FOR AUTOMATIC CLOTHES WASHER TO BE | | | INSTALLED AT 48" ABOVE FINISHED FLOOR. | | | 2. SANITARY RISER DIAGRAM; | | | A) SHOW ON PLANS HOW AND WHERE SECOND FLOOR | | | RISER CONNECTS TO EXISTING BUILDING DRAIN. | | | B) SHOWER DRAIN IS NOT VENTED. | | | C) AUTOMATIC CLOTHES WASHER MUST DISCHARGE DOWN | | | STREAM OF THE BATHROOM GROUP | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-20 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-20 |
Time |
17:18 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-22 |
Time |
17:17 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-22 |
Time |
17:17 |
Sent To |
I |
|
| Notes |
| 2007-05-22 17:20:06 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE 2 COPIES OF AN UPDATED SURVEY | | | SHOWING SCOPE OF WORK WITH DIMENSIONS AND DIMENSIONS TO | | | PROPERTY LINES. | | | | | | 2)PLEASE SHOW ELEVATION FROM GRADE TO THE MIDPOINT | | | OF THE ROOF'S PITCH (OF THE ADDITION). | | | | | | 3)PLEASE PROVIDE FLOOR PLANS FOR BOTH THE 1ST AND | | | 2ND FLOORS. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|